Search criteria

4 vulnerabilities found for b2338-168_firmware by huawei

CVE-2017-8156 (GCVE-0-2017-8156)

Vulnerability from nvd – Published: 2017-11-22 19:00 – Updated: 2024-09-16 17:17
VLAI?
Summary
The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on the serial port. An attacker can access the serial port on the circuit board of the outdoor unit and log in to the CPE without authentication. Successful exploit could allow the attacker to take control over the outdoor unit.
Severity ?
No CVSS data available.
CWE
  • no authentication
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:27:22.840Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.huawei.com/en/psirt/security-advisories/2017/huawei-sa-20170920-01-cpe-en"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "B2338-168",
          "vendor": "Huawei Technologies Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "V100R001C00"
            }
          ]
        }
      ],
      "datePublic": "2017-11-15T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on the serial port. An attacker can access the serial port on the circuit board of the outdoor unit and log in to the CPE without authentication. Successful exploit could allow the attacker to take control over the outdoor unit."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "no authentication",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-11-22T18:57:01",
        "orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
        "shortName": "huawei"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.huawei.com/en/psirt/security-advisories/2017/huawei-sa-20170920-01-cpe-en"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@huawei.com",
          "DATE_PUBLIC": "2017-11-15T00:00:00",
          "ID": "CVE-2017-8156",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "B2338-168",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V100R001C00"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Huawei Technologies Co., Ltd."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on the serial port. An attacker can access the serial port on the circuit board of the outdoor unit and log in to the CPE without authentication. Successful exploit could allow the attacker to take control over the outdoor unit."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "no authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.huawei.com/en/psirt/security-advisories/2017/huawei-sa-20170920-01-cpe-en",
              "refsource": "CONFIRM",
              "url": "http://www.huawei.com/en/psirt/security-advisories/2017/huawei-sa-20170920-01-cpe-en"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
    "assignerShortName": "huawei",
    "cveId": "CVE-2017-8156",
    "datePublished": "2017-11-22T19:00:00Z",
    "dateReserved": "2017-04-25T00:00:00",
    "dateUpdated": "2024-09-16T17:17:41.313Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-8155 (GCVE-0-2017-8155)

Vulnerability from nvd – Published: 2017-11-22 19:00 – Updated: 2024-09-17 03:02
VLAI?
Summary
The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on a certain port. After accessing the network between the indoor and outdoor units of the CPE, an attacker can deliver commands to the specific port of the outdoor unit and execute them without authentication. Successful exploit could allow the attacker to take control over the outdoor unit.
Severity ?
No CVSS data available.
CWE
  • no authentication
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:27:22.571Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.huawei.com/en/psirt/security-advisories/2017/huawei-sa-20170920-01-cpe-en"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "B2338-168",
          "vendor": "Huawei Technologies Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "V100R001C00"
            }
          ]
        }
      ],
      "datePublic": "2017-11-15T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on a certain port. After accessing the network between the indoor and outdoor units of the CPE, an attacker can deliver commands to the specific port of the outdoor unit and execute them without authentication. Successful exploit could allow the attacker to take control over the outdoor unit."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "no authentication",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-11-22T18:57:01",
        "orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
        "shortName": "huawei"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.huawei.com/en/psirt/security-advisories/2017/huawei-sa-20170920-01-cpe-en"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@huawei.com",
          "DATE_PUBLIC": "2017-11-15T00:00:00",
          "ID": "CVE-2017-8155",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "B2338-168",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V100R001C00"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Huawei Technologies Co., Ltd."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on a certain port. After accessing the network between the indoor and outdoor units of the CPE, an attacker can deliver commands to the specific port of the outdoor unit and execute them without authentication. Successful exploit could allow the attacker to take control over the outdoor unit."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "no authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.huawei.com/en/psirt/security-advisories/2017/huawei-sa-20170920-01-cpe-en",
              "refsource": "CONFIRM",
              "url": "http://www.huawei.com/en/psirt/security-advisories/2017/huawei-sa-20170920-01-cpe-en"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
    "assignerShortName": "huawei",
    "cveId": "CVE-2017-8155",
    "datePublished": "2017-11-22T19:00:00Z",
    "dateReserved": "2017-04-25T00:00:00",
    "dateUpdated": "2024-09-17T03:02:09.605Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-8156 (GCVE-0-2017-8156)

Vulnerability from cvelistv5 – Published: 2017-11-22 19:00 – Updated: 2024-09-16 17:17
VLAI?
Summary
The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on the serial port. An attacker can access the serial port on the circuit board of the outdoor unit and log in to the CPE without authentication. Successful exploit could allow the attacker to take control over the outdoor unit.
Severity ?
No CVSS data available.
CWE
  • no authentication
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:27:22.840Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.huawei.com/en/psirt/security-advisories/2017/huawei-sa-20170920-01-cpe-en"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "B2338-168",
          "vendor": "Huawei Technologies Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "V100R001C00"
            }
          ]
        }
      ],
      "datePublic": "2017-11-15T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on the serial port. An attacker can access the serial port on the circuit board of the outdoor unit and log in to the CPE without authentication. Successful exploit could allow the attacker to take control over the outdoor unit."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "no authentication",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-11-22T18:57:01",
        "orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
        "shortName": "huawei"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.huawei.com/en/psirt/security-advisories/2017/huawei-sa-20170920-01-cpe-en"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@huawei.com",
          "DATE_PUBLIC": "2017-11-15T00:00:00",
          "ID": "CVE-2017-8156",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "B2338-168",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V100R001C00"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Huawei Technologies Co., Ltd."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on the serial port. An attacker can access the serial port on the circuit board of the outdoor unit and log in to the CPE without authentication. Successful exploit could allow the attacker to take control over the outdoor unit."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "no authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.huawei.com/en/psirt/security-advisories/2017/huawei-sa-20170920-01-cpe-en",
              "refsource": "CONFIRM",
              "url": "http://www.huawei.com/en/psirt/security-advisories/2017/huawei-sa-20170920-01-cpe-en"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
    "assignerShortName": "huawei",
    "cveId": "CVE-2017-8156",
    "datePublished": "2017-11-22T19:00:00Z",
    "dateReserved": "2017-04-25T00:00:00",
    "dateUpdated": "2024-09-16T17:17:41.313Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-8155 (GCVE-0-2017-8155)

Vulnerability from cvelistv5 – Published: 2017-11-22 19:00 – Updated: 2024-09-17 03:02
VLAI?
Summary
The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on a certain port. After accessing the network between the indoor and outdoor units of the CPE, an attacker can deliver commands to the specific port of the outdoor unit and execute them without authentication. Successful exploit could allow the attacker to take control over the outdoor unit.
Severity ?
No CVSS data available.
CWE
  • no authentication
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:27:22.571Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.huawei.com/en/psirt/security-advisories/2017/huawei-sa-20170920-01-cpe-en"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "B2338-168",
          "vendor": "Huawei Technologies Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "V100R001C00"
            }
          ]
        }
      ],
      "datePublic": "2017-11-15T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on a certain port. After accessing the network between the indoor and outdoor units of the CPE, an attacker can deliver commands to the specific port of the outdoor unit and execute them without authentication. Successful exploit could allow the attacker to take control over the outdoor unit."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "no authentication",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-11-22T18:57:01",
        "orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
        "shortName": "huawei"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.huawei.com/en/psirt/security-advisories/2017/huawei-sa-20170920-01-cpe-en"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@huawei.com",
          "DATE_PUBLIC": "2017-11-15T00:00:00",
          "ID": "CVE-2017-8155",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "B2338-168",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V100R001C00"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Huawei Technologies Co., Ltd."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on a certain port. After accessing the network between the indoor and outdoor units of the CPE, an attacker can deliver commands to the specific port of the outdoor unit and execute them without authentication. Successful exploit could allow the attacker to take control over the outdoor unit."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "no authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.huawei.com/en/psirt/security-advisories/2017/huawei-sa-20170920-01-cpe-en",
              "refsource": "CONFIRM",
              "url": "http://www.huawei.com/en/psirt/security-advisories/2017/huawei-sa-20170920-01-cpe-en"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
    "assignerShortName": "huawei",
    "cveId": "CVE-2017-8155",
    "datePublished": "2017-11-22T19:00:00Z",
    "dateReserved": "2017-04-25T00:00:00",
    "dateUpdated": "2024-09-17T03:02:09.605Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}