CVE-2021-20709 (GCVE-0-2021-20709)

Vulnerability from nvd – Published: 2021-04-26 00:20 – Updated: 2024-08-03 17:53
VLAI?
Summary
Improper validation of integrity check value vulnerability in NEC Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier allows an attacker with an administrative privilege to execute arbitrary OS commands by sending a specially crafted request to a specific URL.
Severity ?
No CVSS data available.
CWE
  • Improper Validation of Integrity Check Value
Assigner
Impacted products
Vendor Product Version
NEC Corporation NEC Aterm devices Affected: Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:53:21.222Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jpn.nec.com/security-info/secinfo/nv21-010.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/jp/JVN29739718/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "NEC Aterm devices",
          "vendor": "NEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper validation of integrity check value vulnerability in NEC Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier allows an attacker with an administrative privilege to execute arbitrary OS commands by sending a specially crafted request to a specific URL."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Improper Validation of Integrity Check Value",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-26T00:20:44",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jpn.nec.com/security-info/secinfo/nv21-010.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/en/jp/JVN29739718/index.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2021-20709",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "NEC Aterm devices",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NEC Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper validation of integrity check value vulnerability in NEC Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier allows an attacker with an administrative privilege to execute arbitrary OS commands by sending a specially crafted request to a specific URL."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Improper Validation of Integrity Check Value"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://jpn.nec.com/security-info/secinfo/nv21-010.html",
              "refsource": "MISC",
              "url": "https://jpn.nec.com/security-info/secinfo/nv21-010.html"
            },
            {
              "name": "https://jvn.jp/en/jp/JVN29739718/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/en/jp/JVN29739718/index.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2021-20709",
    "datePublished": "2021-04-26T00:20:44",
    "dateReserved": "2020-12-17T00:00:00",
    "dateUpdated": "2024-08-03T17:53:21.222Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-20708 (GCVE-0-2021-20708)

Vulnerability from nvd – Published: 2021-04-26 00:20 – Updated: 2024-08-03 17:53
VLAI?
Summary
NEC Aterm devices (Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier) allow authenticated attackers to execute arbitrary OS commands by sending a specially crafted request to a specific URL.
Severity ?
No CVSS data available.
CWE
  • OS Command Injection
Assigner
Impacted products
Vendor Product Version
NEC Corporation NEC Aterm devices Affected: Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:53:21.266Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jpn.nec.com/security-info/secinfo/nv21-010.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/jp/JVN29739718/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "NEC Aterm devices",
          "vendor": "NEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "NEC Aterm devices (Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier) allow authenticated attackers to execute arbitrary OS commands by sending a specially crafted request to a specific URL."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "OS Command Injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-26T00:20:43",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jpn.nec.com/security-info/secinfo/nv21-010.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/en/jp/JVN29739718/index.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2021-20708",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "NEC Aterm devices",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NEC Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "NEC Aterm devices (Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier) allow authenticated attackers to execute arbitrary OS commands by sending a specially crafted request to a specific URL."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OS Command Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://jpn.nec.com/security-info/secinfo/nv21-010.html",
              "refsource": "MISC",
              "url": "https://jpn.nec.com/security-info/secinfo/nv21-010.html"
            },
            {
              "name": "https://jvn.jp/en/jp/JVN29739718/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/en/jp/JVN29739718/index.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2021-20708",
    "datePublished": "2021-04-26T00:20:44",
    "dateReserved": "2020-12-17T00:00:00",
    "dateUpdated": "2024-08-03T17:53:21.266Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-16195 (GCVE-0-2018-16195)

Vulnerability from nvd – Published: 2019-01-09 22:00 – Updated: 2024-08-05 10:17
VLAI?
Summary
Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows an attacker on the same network segment to execute arbitrary OS commands via SOAP interface of UPnP.
Severity ?
No CVSS data available.
CWE
  • OS Command Injection
Assigner
References
Impacted products
Vendor Product Version
NEC Corporation Aterm WF1200CR and Aterm WG1200CR Affected: (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T10:17:38.325Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "JVN#87535892",
            "tags": [
              "third-party-advisory",
              "x_refsource_JVN",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Aterm WF1200CR and Aterm WG1200CR",
          "vendor": "NEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
            }
          ]
        }
      ],
      "datePublic": "2019-01-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows an attacker on the same network segment to execute arbitrary OS commands via SOAP interface of UPnP."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "OS Command Injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-01-09T21:57:01",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "name": "JVN#87535892",
          "tags": [
            "third-party-advisory",
            "x_refsource_JVN"
          ],
          "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2018-16195",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Aterm WF1200CR and Aterm WG1200CR",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NEC Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows an attacker on the same network segment to execute arbitrary OS commands via SOAP interface of UPnP."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OS Command Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "JVN#87535892",
              "refsource": "JVN",
              "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
            },
            {
              "name": "https://jpn.nec.com/security-info/secinfo/nv18-021.html",
              "refsource": "MISC",
              "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2018-16195",
    "datePublished": "2019-01-09T22:00:00",
    "dateReserved": "2018-08-30T00:00:00",
    "dateUpdated": "2024-08-05T10:17:38.325Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-16194 (GCVE-0-2018-16194)

Vulnerability from nvd – Published: 2019-01-09 22:00 – Updated: 2024-08-05 10:17
VLAI?
Summary
Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to execute arbitrary OS commands via unspecified vectors.
Severity ?
No CVSS data available.
CWE
  • OS Command Injection
Assigner
References
Impacted products
Vendor Product Version
NEC Corporation Aterm WF1200CR and Aterm WG1200CR Affected: (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T10:17:38.393Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "JVN#87535892",
            "tags": [
              "third-party-advisory",
              "x_refsource_JVN",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Aterm WF1200CR and Aterm WG1200CR",
          "vendor": "NEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
            }
          ]
        }
      ],
      "datePublic": "2019-01-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to execute arbitrary OS commands via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "OS Command Injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-01-09T21:57:01",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "name": "JVN#87535892",
          "tags": [
            "third-party-advisory",
            "x_refsource_JVN"
          ],
          "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2018-16194",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Aterm WF1200CR and Aterm WG1200CR",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NEC Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to execute arbitrary OS commands via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OS Command Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "JVN#87535892",
              "refsource": "JVN",
              "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
            },
            {
              "name": "https://jpn.nec.com/security-info/secinfo/nv18-021.html",
              "refsource": "MISC",
              "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2018-16194",
    "datePublished": "2019-01-09T22:00:00",
    "dateReserved": "2018-08-30T00:00:00",
    "dateUpdated": "2024-08-05T10:17:38.393Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-16193 (GCVE-0-2018-16193)

Vulnerability from nvd – Published: 2019-01-09 22:00 – Updated: 2024-08-05 10:17
VLAI?
Summary
Cross-site scripting vulnerability in Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to inject arbitrary web script or HTML via unspecified vectors.
Severity ?
No CVSS data available.
CWE
  • Cross-site scripting
Assigner
References
Impacted products
Vendor Product Version
NEC Corporation Aterm WF1200CR and Aterm WG1200CR Affected: (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T10:17:38.355Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "JVN#87535892",
            "tags": [
              "third-party-advisory",
              "x_refsource_JVN",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Aterm WF1200CR and Aterm WG1200CR",
          "vendor": "NEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
            }
          ]
        }
      ],
      "datePublic": "2019-01-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Cross-site scripting vulnerability in Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to inject arbitrary web script or HTML via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Cross-site scripting",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-01-09T21:57:01",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "name": "JVN#87535892",
          "tags": [
            "third-party-advisory",
            "x_refsource_JVN"
          ],
          "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2018-16193",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Aterm WF1200CR and Aterm WG1200CR",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NEC Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cross-site scripting vulnerability in Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to inject arbitrary web script or HTML via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Cross-site scripting"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "JVN#87535892",
              "refsource": "JVN",
              "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
            },
            {
              "name": "https://jpn.nec.com/security-info/secinfo/nv18-021.html",
              "refsource": "MISC",
              "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2018-16193",
    "datePublished": "2019-01-09T22:00:00",
    "dateReserved": "2018-08-30T00:00:00",
    "dateUpdated": "2024-08-05T10:17:38.355Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-16192 (GCVE-0-2018-16192)

Vulnerability from nvd – Published: 2019-01-09 22:00 – Updated: 2024-08-05 10:17
VLAI?
Summary
Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allow an attacker on the same network segment to obtain information registered on the device via unspecified vectors.
Severity ?
No CVSS data available.
CWE
  • Information Disclosure
Assigner
References
Impacted products
Vendor Product Version
NEC Corporation Aterm WF1200CR and Aterm WG1200CR Affected: (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T10:17:38.386Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "JVN#87535892",
            "tags": [
              "third-party-advisory",
              "x_refsource_JVN",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Aterm WF1200CR and Aterm WG1200CR",
          "vendor": "NEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
            }
          ]
        }
      ],
      "datePublic": "2019-01-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allow an attacker on the same network segment to obtain information registered on the device via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Information Disclosure",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-01-09T21:57:01",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "name": "JVN#87535892",
          "tags": [
            "third-party-advisory",
            "x_refsource_JVN"
          ],
          "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2018-16192",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Aterm WF1200CR and Aterm WG1200CR",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NEC Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allow an attacker on the same network segment to obtain information registered on the device via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Information Disclosure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "JVN#87535892",
              "refsource": "JVN",
              "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
            },
            {
              "name": "https://jpn.nec.com/security-info/secinfo/nv18-021.html",
              "refsource": "MISC",
              "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2018-16192",
    "datePublished": "2019-01-09T22:00:00",
    "dateReserved": "2018-08-30T00:00:00",
    "dateUpdated": "2024-08-05T10:17:38.386Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-20709 (GCVE-0-2021-20709)

Vulnerability from cvelistv5 – Published: 2021-04-26 00:20 – Updated: 2024-08-03 17:53
VLAI?
Summary
Improper validation of integrity check value vulnerability in NEC Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier allows an attacker with an administrative privilege to execute arbitrary OS commands by sending a specially crafted request to a specific URL.
Severity ?
No CVSS data available.
CWE
  • Improper Validation of Integrity Check Value
Assigner
Impacted products
Vendor Product Version
NEC Corporation NEC Aterm devices Affected: Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:53:21.222Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jpn.nec.com/security-info/secinfo/nv21-010.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/jp/JVN29739718/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "NEC Aterm devices",
          "vendor": "NEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper validation of integrity check value vulnerability in NEC Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier allows an attacker with an administrative privilege to execute arbitrary OS commands by sending a specially crafted request to a specific URL."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Improper Validation of Integrity Check Value",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-26T00:20:44",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jpn.nec.com/security-info/secinfo/nv21-010.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/en/jp/JVN29739718/index.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2021-20709",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "NEC Aterm devices",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NEC Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper validation of integrity check value vulnerability in NEC Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier allows an attacker with an administrative privilege to execute arbitrary OS commands by sending a specially crafted request to a specific URL."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Improper Validation of Integrity Check Value"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://jpn.nec.com/security-info/secinfo/nv21-010.html",
              "refsource": "MISC",
              "url": "https://jpn.nec.com/security-info/secinfo/nv21-010.html"
            },
            {
              "name": "https://jvn.jp/en/jp/JVN29739718/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/en/jp/JVN29739718/index.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2021-20709",
    "datePublished": "2021-04-26T00:20:44",
    "dateReserved": "2020-12-17T00:00:00",
    "dateUpdated": "2024-08-03T17:53:21.222Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-20708 (GCVE-0-2021-20708)

Vulnerability from cvelistv5 – Published: 2021-04-26 00:20 – Updated: 2024-08-03 17:53
VLAI?
Summary
NEC Aterm devices (Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier) allow authenticated attackers to execute arbitrary OS commands by sending a specially crafted request to a specific URL.
Severity ?
No CVSS data available.
CWE
  • OS Command Injection
Assigner
Impacted products
Vendor Product Version
NEC Corporation NEC Aterm devices Affected: Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:53:21.266Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jpn.nec.com/security-info/secinfo/nv21-010.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/jp/JVN29739718/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "NEC Aterm devices",
          "vendor": "NEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "NEC Aterm devices (Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier) allow authenticated attackers to execute arbitrary OS commands by sending a specially crafted request to a specific URL."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "OS Command Injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-26T00:20:43",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jpn.nec.com/security-info/secinfo/nv21-010.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/en/jp/JVN29739718/index.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2021-20708",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "NEC Aterm devices",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NEC Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "NEC Aterm devices (Aterm WF1200CR firmware Ver1.3.2 and earlier, Aterm WG1200CR firmware Ver1.3.3 and earlier, and Aterm WG2600HS firmware Ver1.5.1 and earlier) allow authenticated attackers to execute arbitrary OS commands by sending a specially crafted request to a specific URL."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OS Command Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://jpn.nec.com/security-info/secinfo/nv21-010.html",
              "refsource": "MISC",
              "url": "https://jpn.nec.com/security-info/secinfo/nv21-010.html"
            },
            {
              "name": "https://jvn.jp/en/jp/JVN29739718/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/en/jp/JVN29739718/index.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2021-20708",
    "datePublished": "2021-04-26T00:20:44",
    "dateReserved": "2020-12-17T00:00:00",
    "dateUpdated": "2024-08-03T17:53:21.266Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-16193 (GCVE-0-2018-16193)

Vulnerability from cvelistv5 – Published: 2019-01-09 22:00 – Updated: 2024-08-05 10:17
VLAI?
Summary
Cross-site scripting vulnerability in Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to inject arbitrary web script or HTML via unspecified vectors.
Severity ?
No CVSS data available.
CWE
  • Cross-site scripting
Assigner
References
Impacted products
Vendor Product Version
NEC Corporation Aterm WF1200CR and Aterm WG1200CR Affected: (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T10:17:38.355Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "JVN#87535892",
            "tags": [
              "third-party-advisory",
              "x_refsource_JVN",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Aterm WF1200CR and Aterm WG1200CR",
          "vendor": "NEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
            }
          ]
        }
      ],
      "datePublic": "2019-01-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Cross-site scripting vulnerability in Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to inject arbitrary web script or HTML via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Cross-site scripting",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-01-09T21:57:01",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "name": "JVN#87535892",
          "tags": [
            "third-party-advisory",
            "x_refsource_JVN"
          ],
          "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2018-16193",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Aterm WF1200CR and Aterm WG1200CR",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NEC Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cross-site scripting vulnerability in Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to inject arbitrary web script or HTML via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Cross-site scripting"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "JVN#87535892",
              "refsource": "JVN",
              "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
            },
            {
              "name": "https://jpn.nec.com/security-info/secinfo/nv18-021.html",
              "refsource": "MISC",
              "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2018-16193",
    "datePublished": "2019-01-09T22:00:00",
    "dateReserved": "2018-08-30T00:00:00",
    "dateUpdated": "2024-08-05T10:17:38.355Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-16192 (GCVE-0-2018-16192)

Vulnerability from cvelistv5 – Published: 2019-01-09 22:00 – Updated: 2024-08-05 10:17
VLAI?
Summary
Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allow an attacker on the same network segment to obtain information registered on the device via unspecified vectors.
Severity ?
No CVSS data available.
CWE
  • Information Disclosure
Assigner
References
Impacted products
Vendor Product Version
NEC Corporation Aterm WF1200CR and Aterm WG1200CR Affected: (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T10:17:38.386Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "JVN#87535892",
            "tags": [
              "third-party-advisory",
              "x_refsource_JVN",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Aterm WF1200CR and Aterm WG1200CR",
          "vendor": "NEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
            }
          ]
        }
      ],
      "datePublic": "2019-01-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allow an attacker on the same network segment to obtain information registered on the device via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Information Disclosure",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-01-09T21:57:01",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "name": "JVN#87535892",
          "tags": [
            "third-party-advisory",
            "x_refsource_JVN"
          ],
          "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2018-16192",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Aterm WF1200CR and Aterm WG1200CR",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NEC Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allow an attacker on the same network segment to obtain information registered on the device via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Information Disclosure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "JVN#87535892",
              "refsource": "JVN",
              "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
            },
            {
              "name": "https://jpn.nec.com/security-info/secinfo/nv18-021.html",
              "refsource": "MISC",
              "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2018-16192",
    "datePublished": "2019-01-09T22:00:00",
    "dateReserved": "2018-08-30T00:00:00",
    "dateUpdated": "2024-08-05T10:17:38.386Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-16195 (GCVE-0-2018-16195)

Vulnerability from cvelistv5 – Published: 2019-01-09 22:00 – Updated: 2024-08-05 10:17
VLAI?
Summary
Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows an attacker on the same network segment to execute arbitrary OS commands via SOAP interface of UPnP.
Severity ?
No CVSS data available.
CWE
  • OS Command Injection
Assigner
References
Impacted products
Vendor Product Version
NEC Corporation Aterm WF1200CR and Aterm WG1200CR Affected: (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T10:17:38.325Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "JVN#87535892",
            "tags": [
              "third-party-advisory",
              "x_refsource_JVN",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Aterm WF1200CR and Aterm WG1200CR",
          "vendor": "NEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
            }
          ]
        }
      ],
      "datePublic": "2019-01-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows an attacker on the same network segment to execute arbitrary OS commands via SOAP interface of UPnP."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "OS Command Injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-01-09T21:57:01",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "name": "JVN#87535892",
          "tags": [
            "third-party-advisory",
            "x_refsource_JVN"
          ],
          "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2018-16195",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Aterm WF1200CR and Aterm WG1200CR",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NEC Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows an attacker on the same network segment to execute arbitrary OS commands via SOAP interface of UPnP."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OS Command Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "JVN#87535892",
              "refsource": "JVN",
              "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
            },
            {
              "name": "https://jpn.nec.com/security-info/secinfo/nv18-021.html",
              "refsource": "MISC",
              "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2018-16195",
    "datePublished": "2019-01-09T22:00:00",
    "dateReserved": "2018-08-30T00:00:00",
    "dateUpdated": "2024-08-05T10:17:38.325Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-16194 (GCVE-0-2018-16194)

Vulnerability from cvelistv5 – Published: 2019-01-09 22:00 – Updated: 2024-08-05 10:17
VLAI?
Summary
Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to execute arbitrary OS commands via unspecified vectors.
Severity ?
No CVSS data available.
CWE
  • OS Command Injection
Assigner
References
Impacted products
Vendor Product Version
NEC Corporation Aterm WF1200CR and Aterm WG1200CR Affected: (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T10:17:38.393Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "JVN#87535892",
            "tags": [
              "third-party-advisory",
              "x_refsource_JVN",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Aterm WF1200CR and Aterm WG1200CR",
          "vendor": "NEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
            }
          ]
        }
      ],
      "datePublic": "2019-01-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to execute arbitrary OS commands via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "OS Command Injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-01-09T21:57:01",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "name": "JVN#87535892",
          "tags": [
            "third-party-advisory",
            "x_refsource_JVN"
          ],
          "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2018-16194",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Aterm WF1200CR and Aterm WG1200CR",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NEC Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to execute arbitrary OS commands via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OS Command Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "JVN#87535892",
              "refsource": "JVN",
              "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
            },
            {
              "name": "https://jpn.nec.com/security-info/secinfo/nv18-021.html",
              "refsource": "MISC",
              "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2018-16194",
    "datePublished": "2019-01-09T22:00:00",
    "dateReserved": "2018-08-30T00:00:00",
    "dateUpdated": "2024-08-05T10:17:38.393Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}