Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for ark library by Bandisoft International Inc.

    CVE-2021-26635 (GCVE-0-2021-26635)

    Vulnerability from nvd – Published: 2022-06-01 15:04 – Updated: 2024-08-03 20:26
    VLAI
    Title
    Bandisoft ARK Library buffer overflow vulnerability
    Summary
    In the code that verifies the file size in the ark library, it is possible to manipulate the offset read from the target file due to the wrong use of the data type. An attacker could use this vulnerability to cause a stack buffer overflow and as a result, perform an attack such as remote code execution.
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    References
    Impacted products
    Vendor Product Version
    Bandisoft International Inc. ark library Affected: unspecified , ≤ 7.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:26:25.566Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.krcert.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=66747"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "platforms": [
                "Windows, Mac OS, Linux and etc."
              ],
              "product": "ark library",
              "vendor": "Bandisoft International Inc.",
              "versions": [
                {
                  "lessThanOrEqual": "7.17",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In the code that verifies the file size in the ark library, it is possible to manipulate the offset read from the target file due to the wrong use of the data type. An attacker could use this vulnerability to cause a stack buffer overflow and as a result, perform an attack such as remote code execution."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-01T15:04:52.000Z",
            "orgId": "cdd7a122-0fae-4202-8d86-14efbacc2863",
            "shortName": "krcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.krcert.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=66747"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Bandisoft ARK Library buffer overflow vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vuln@krcert.or.kr",
              "ID": "CVE-2021-26635",
              "STATE": "PUBLIC",
              "TITLE": "Bandisoft ARK Library buffer overflow vulnerability"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ark library",
                          "version": {
                            "version_data": [
                              {
                                "platform": "Windows, Mac OS, Linux and etc.",
                                "version_affected": "\u003c=",
                                "version_value": "7.17"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Bandisoft International Inc."
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In the code that verifies the file size in the ark library, it is possible to manipulate the offset read from the target file due to the wrong use of the data type. An attacker could use this vulnerability to cause a stack buffer overflow and as a result, perform an attack such as remote code execution."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-121 Stack-based Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.krcert.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=66747",
                  "refsource": "MISC",
                  "url": "https://www.krcert.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=66747"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cdd7a122-0fae-4202-8d86-14efbacc2863",
        "assignerShortName": "krcert",
        "cveId": "CVE-2021-26635",
        "datePublished": "2022-06-01T15:04:52.000Z",
        "dateReserved": "2021-02-03T00:00:00.000Z",
        "dateUpdated": "2024-08-03T20:26:25.566Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-26635 (GCVE-0-2021-26635)

    Vulnerability from cvelistv5 – Published: 2022-06-01 15:04 – Updated: 2024-08-03 20:26
    VLAI
    Title
    Bandisoft ARK Library buffer overflow vulnerability
    Summary
    In the code that verifies the file size in the ark library, it is possible to manipulate the offset read from the target file due to the wrong use of the data type. An attacker could use this vulnerability to cause a stack buffer overflow and as a result, perform an attack such as remote code execution.
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    References
    Impacted products
    Vendor Product Version
    Bandisoft International Inc. ark library Affected: unspecified , ≤ 7.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:26:25.566Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.krcert.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=66747"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "platforms": [
                "Windows, Mac OS, Linux and etc."
              ],
              "product": "ark library",
              "vendor": "Bandisoft International Inc.",
              "versions": [
                {
                  "lessThanOrEqual": "7.17",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In the code that verifies the file size in the ark library, it is possible to manipulate the offset read from the target file due to the wrong use of the data type. An attacker could use this vulnerability to cause a stack buffer overflow and as a result, perform an attack such as remote code execution."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-01T15:04:52.000Z",
            "orgId": "cdd7a122-0fae-4202-8d86-14efbacc2863",
            "shortName": "krcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.krcert.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=66747"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Bandisoft ARK Library buffer overflow vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vuln@krcert.or.kr",
              "ID": "CVE-2021-26635",
              "STATE": "PUBLIC",
              "TITLE": "Bandisoft ARK Library buffer overflow vulnerability"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ark library",
                          "version": {
                            "version_data": [
                              {
                                "platform": "Windows, Mac OS, Linux and etc.",
                                "version_affected": "\u003c=",
                                "version_value": "7.17"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Bandisoft International Inc."
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In the code that verifies the file size in the ark library, it is possible to manipulate the offset read from the target file due to the wrong use of the data type. An attacker could use this vulnerability to cause a stack buffer overflow and as a result, perform an attack such as remote code execution."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-121 Stack-based Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.krcert.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=66747",
                  "refsource": "MISC",
                  "url": "https://www.krcert.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=66747"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cdd7a122-0fae-4202-8d86-14efbacc2863",
        "assignerShortName": "krcert",
        "cveId": "CVE-2021-26635",
        "datePublished": "2022-06-01T15:04:52.000Z",
        "dateReserved": "2021-02-03T00:00:00.000Z",
        "dateUpdated": "2024-08-03T20:26:25.566Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }