    CVE-2011-2779 (GCVE-0-2011-2779)

    Vulnerability from nvd – Published: 2011-07-19 21:00 – Updated: 2024-08-06 23:15
    VLAI
    Summary
    Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 uses world-writable permissions for exported report files, which allows local users to change or delete log data by modifying a file, a different vulnerability than CVE-2011-0770.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    URL Tags
    https://exchange.xforce.ibmcloud.com/vulnerabilit… vdb-entryx_refsource_XF
    http://www.kb.cert.org/vuls/id/122054 third-party-advisoryx_refsource_CERT-VN
    Date Public
    2011-07-15 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T23:15:30.796Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "arcsight-windows-event-priv-escalation(68855)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68855"
              },
              {
                "name": "VU#122054",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/122054"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-07-15T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 uses world-writable permissions for exported report files, which allows local users to change or delete log data by modifying a file, a different vulnerability than CVE-2011-0770."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "arcsight-windows-event-priv-escalation(68855)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68855"
            },
            {
              "name": "VU#122054",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/122054"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2011-2779",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 uses world-writable permissions for exported report files, which allows local users to change or delete log data by modifying a file, a different vulnerability than CVE-2011-0770."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "arcsight-windows-event-priv-escalation(68855)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68855"
                },
                {
                  "name": "VU#122054",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/122054"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2011-2779",
        "datePublished": "2011-07-19T21:00:00.000Z",
        "dateReserved": "2011-07-19T00:00:00.000Z",
        "dateUpdated": "2024-08-06T23:15:30.796Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-0770 (GCVE-0-2011-0770)

    Vulnerability from nvd – Published: 2011-07-19 20:00 – Updated: 2024-08-06 22:05
    VLAI
    Summary
    Cross-site scripting (XSS) vulnerability in Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 allows remote attackers to inject arbitrary web script or HTML via the Windows XP variable in a file.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    URL Tags
    https://exchange.xforce.ibmcloud.com/vulnerabilit… vdb-entryx_refsource_XF
    http://www.securityfocus.com/bid/48694 vdb-entryx_refsource_BID
    http://www.kb.cert.org/vuls/id/122054 third-party-advisoryx_refsource_CERT-VN
    http://securitytracker.com/id?1025791 vdb-entryx_refsource_SECTRACK
    Date Public
    2011-07-15 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T22:05:53.744Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "arcsight-connector-xss(68569)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68569"
              },
              {
                "name": "48694",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/48694"
              },
              {
                "name": "VU#122054",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/122054"
              },
              {
                "name": "1025791",
                "tags": [
                  "vdb-entry",
                  "x_refsource_SECTRACK",
                  "x_transferred"
                ],
                "url": "http://securitytracker.com/id?1025791"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-07-15T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site scripting (XSS) vulnerability in Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 allows remote attackers to inject arbitrary web script or HTML via the Windows XP variable in a file."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-16T14:57:01.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "name": "arcsight-connector-xss(68569)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68569"
            },
            {
              "name": "48694",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/48694"
            },
            {
              "name": "VU#122054",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/122054"
            },
            {
              "name": "1025791",
              "tags": [
                "vdb-entry",
                "x_refsource_SECTRACK"
              ],
              "url": "http://securitytracker.com/id?1025791"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-0770",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site scripting (XSS) vulnerability in Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 allows remote attackers to inject arbitrary web script or HTML via the Windows XP variable in a file."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "arcsight-connector-xss(68569)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68569"
                },
                {
                  "name": "48694",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/48694"
                },
                {
                  "name": "VU#122054",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/122054"
                },
                {
                  "name": "1025791",
                  "refsource": "SECTRACK",
                  "url": "http://securitytracker.com/id?1025791"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-0770",
        "datePublished": "2011-07-19T20:00:00.000Z",
        "dateReserved": "2011-02-03T00:00:00.000Z",
        "dateUpdated": "2024-08-06T22:05:53.744Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-2779 (GCVE-0-2011-2779)

    Vulnerability from cvelistv5 – Published: 2011-07-19 21:00 – Updated: 2024-08-06 23:15
    VLAI
    Summary
    Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 uses world-writable permissions for exported report files, which allows local users to change or delete log data by modifying a file, a different vulnerability than CVE-2011-0770.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    URL Tags
    https://exchange.xforce.ibmcloud.com/vulnerabilit… vdb-entryx_refsource_XF
    http://www.kb.cert.org/vuls/id/122054 third-party-advisoryx_refsource_CERT-VN
    Date Public
    2011-07-15 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T23:15:30.796Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "arcsight-windows-event-priv-escalation(68855)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68855"
              },
              {
                "name": "VU#122054",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/122054"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-07-15T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 uses world-writable permissions for exported report files, which allows local users to change or delete log data by modifying a file, a different vulnerability than CVE-2011-0770."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "arcsight-windows-event-priv-escalation(68855)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68855"
            },
            {
              "name": "VU#122054",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/122054"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2011-2779",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 uses world-writable permissions for exported report files, which allows local users to change or delete log data by modifying a file, a different vulnerability than CVE-2011-0770."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "arcsight-windows-event-priv-escalation(68855)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68855"
                },
                {
                  "name": "VU#122054",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/122054"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2011-2779",
        "datePublished": "2011-07-19T21:00:00.000Z",
        "dateReserved": "2011-07-19T00:00:00.000Z",
        "dateUpdated": "2024-08-06T23:15:30.796Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-0770 (GCVE-0-2011-0770)

    Vulnerability from cvelistv5 – Published: 2011-07-19 20:00 – Updated: 2024-08-06 22:05
    VLAI
    Summary
    Cross-site scripting (XSS) vulnerability in Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 allows remote attackers to inject arbitrary web script or HTML via the Windows XP variable in a file.
    Severity
    No CVSS data available.
    CWE
    • n/a
    References
    URL Tags
    https://exchange.xforce.ibmcloud.com/vulnerabilit… vdb-entryx_refsource_XF
    http://www.securityfocus.com/bid/48694 vdb-entryx_refsource_BID
    http://www.kb.cert.org/vuls/id/122054 third-party-advisoryx_refsource_CERT-VN
    http://securitytracker.com/id?1025791 vdb-entryx_refsource_SECTRACK
    Date Public
    2011-07-15 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T22:05:53.744Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "arcsight-connector-xss(68569)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68569"
              },
              {
                "name": "48694",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/48694"
              },
              {
                "name": "VU#122054",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/122054"
              },
              {
                "name": "1025791",
                "tags": [
                  "vdb-entry",
                  "x_refsource_SECTRACK",
                  "x_transferred"
                ],
                "url": "http://securitytracker.com/id?1025791"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-07-15T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site scripting (XSS) vulnerability in Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 allows remote attackers to inject arbitrary web script or HTML via the Windows XP variable in a file."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-16T14:57:01.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "name": "arcsight-connector-xss(68569)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68569"
            },
            {
              "name": "48694",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/48694"
            },
            {
              "name": "VU#122054",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/122054"
            },
            {
              "name": "1025791",
              "tags": [
                "vdb-entry",
                "x_refsource_SECTRACK"
              ],
              "url": "http://securitytracker.com/id?1025791"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-0770",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site scripting (XSS) vulnerability in Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 allows remote attackers to inject arbitrary web script or HTML via the Windows XP variable in a file."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "arcsight-connector-xss(68569)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68569"
                },
                {
                  "name": "48694",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/48694"
                },
                {
                  "name": "VU#122054",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/122054"
                },
                {
                  "name": "1025791",
                  "refsource": "SECTRACK",
                  "url": "http://securitytracker.com/id?1025791"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-0770",
        "datePublished": "2011-07-19T20:00:00.000Z",
        "dateReserved": "2011-02-03T00:00:00.000Z",
        "dateUpdated": "2024-08-06T22:05:53.744Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }