Search criteria

4 vulnerabilities found for alienware_m15_a6_firmware by dell

CVE-2022-34399 (GCVE-0-2022-34399)

Vulnerability from nvd – Published: 2023-01-18 11:20 – Updated: 2025-04-03 18:06
VLAI?
Summary
Dell Alienware m17 R5 BIOS version prior to 1.2.2 contain a buffer access vulnerability. A malicious user with admin privileges could potentially exploit this vulnerability by sending input larger than expected in order to leak certain sections of SMRAM.
CWE
  • CWE-805 - Buffer Access with Incorrect Length Value
Assigner
References
Impacted products
Vendor Product Version
Dell CPG BIOS Affected: 0 , < 1.2.2 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:07:16.347Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000205329/dsa-2022-317-dell-client-security-update-for-dell-client-bios"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-34399",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-02T16:13:06.740646Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-03T18:06:10.706Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CPG BIOS",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-11-15T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eDell Alienware m17 R5 BIOS version prior to 1.2.2 contain a buffer access vulnerability. A malicious user with admin privileges could potentially exploit this vulnerability by sending input larger than expected in order to leak certain sections of SMRAM.\u003c/div\u003e\u003c/div\u003e\n\n"
            }
          ],
          "value": "\nDell Alienware m17 R5 BIOS version prior to 1.2.2 contain a buffer access vulnerability. A malicious user with admin privileges could potentially exploit this vulnerability by sending input larger than expected in order to leak certain sections of SMRAM.\n\n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-805",
              "description": "CWE-805: Buffer Access with Incorrect Length Value",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-18T11:20:21.705Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000205329/dsa-2022-317-dell-client-security-update-for-dell-client-bios"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2022-34399",
    "datePublished": "2023-01-18T11:20:21.705Z",
    "dateReserved": "2022-06-23T18:55:17.098Z",
    "dateUpdated": "2025-04-03T18:06:10.706Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-34401 (GCVE-0-2022-34401)

Vulnerability from nvd – Published: 2023-01-18 05:51 – Updated: 2025-04-03 19:42
VLAI?
Summary
Dell BIOS contains a stack based buffer overflow vulnerability. A local authenticated malicious user may potentially exploit this vulnerability by using an SMI to send larger than expected input to a parameter in order to gain arbitrary code execution in SMRAM.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Dell CPG BIOS Affected: 1.4.3
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:07:16.153Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000204679"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-34401",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-02T16:22:25.615657Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-03T19:42:05.249Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CPG BIOS",
          "vendor": "Dell",
          "versions": [
            {
              "status": "affected",
              "version": "1.4.3"
            }
          ]
        }
      ],
      "datePublic": "2022-10-27T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eDell BIOS contains a stack based buffer overflow vulnerability. A local authenticated malicious user may potentially exploit this vulnerability by using an SMI to send larger than expected input to a parameter in order to gain arbitrary code execution in SMRAM.\u003c/div\u003e\u003c/div\u003e\n\n"
            }
          ],
          "value": "\nDell BIOS contains a stack based buffer overflow vulnerability. A local authenticated malicious user may potentially exploit this vulnerability by using an SMI to send larger than expected input to a parameter in order to gain arbitrary code execution in SMRAM.\n\n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-18T05:51:09.851Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/000204679"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2022-34401",
    "datePublished": "2023-01-18T05:51:09.851Z",
    "dateReserved": "2022-06-23T18:55:17.099Z",
    "dateUpdated": "2025-04-03T19:42:05.249Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-34399 (GCVE-0-2022-34399)

Vulnerability from cvelistv5 – Published: 2023-01-18 11:20 – Updated: 2025-04-03 18:06
VLAI?
Summary
Dell Alienware m17 R5 BIOS version prior to 1.2.2 contain a buffer access vulnerability. A malicious user with admin privileges could potentially exploit this vulnerability by sending input larger than expected in order to leak certain sections of SMRAM.
CWE
  • CWE-805 - Buffer Access with Incorrect Length Value
Assigner
References
Impacted products
Vendor Product Version
Dell CPG BIOS Affected: 0 , < 1.2.2 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:07:16.347Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000205329/dsa-2022-317-dell-client-security-update-for-dell-client-bios"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-34399",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-02T16:13:06.740646Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-03T18:06:10.706Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CPG BIOS",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-11-15T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eDell Alienware m17 R5 BIOS version prior to 1.2.2 contain a buffer access vulnerability. A malicious user with admin privileges could potentially exploit this vulnerability by sending input larger than expected in order to leak certain sections of SMRAM.\u003c/div\u003e\u003c/div\u003e\n\n"
            }
          ],
          "value": "\nDell Alienware m17 R5 BIOS version prior to 1.2.2 contain a buffer access vulnerability. A malicious user with admin privileges could potentially exploit this vulnerability by sending input larger than expected in order to leak certain sections of SMRAM.\n\n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-805",
              "description": "CWE-805: Buffer Access with Incorrect Length Value",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-18T11:20:21.705Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000205329/dsa-2022-317-dell-client-security-update-for-dell-client-bios"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2022-34399",
    "datePublished": "2023-01-18T11:20:21.705Z",
    "dateReserved": "2022-06-23T18:55:17.098Z",
    "dateUpdated": "2025-04-03T18:06:10.706Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-34401 (GCVE-0-2022-34401)

Vulnerability from cvelistv5 – Published: 2023-01-18 05:51 – Updated: 2025-04-03 19:42
VLAI?
Summary
Dell BIOS contains a stack based buffer overflow vulnerability. A local authenticated malicious user may potentially exploit this vulnerability by using an SMI to send larger than expected input to a parameter in order to gain arbitrary code execution in SMRAM.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Dell CPG BIOS Affected: 1.4.3
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:07:16.153Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000204679"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-34401",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-02T16:22:25.615657Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-03T19:42:05.249Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CPG BIOS",
          "vendor": "Dell",
          "versions": [
            {
              "status": "affected",
              "version": "1.4.3"
            }
          ]
        }
      ],
      "datePublic": "2022-10-27T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eDell BIOS contains a stack based buffer overflow vulnerability. A local authenticated malicious user may potentially exploit this vulnerability by using an SMI to send larger than expected input to a parameter in order to gain arbitrary code execution in SMRAM.\u003c/div\u003e\u003c/div\u003e\n\n"
            }
          ],
          "value": "\nDell BIOS contains a stack based buffer overflow vulnerability. A local authenticated malicious user may potentially exploit this vulnerability by using an SMI to send larger than expected input to a parameter in order to gain arbitrary code execution in SMRAM.\n\n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-18T05:51:09.851Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/000204679"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2022-34401",
    "datePublished": "2023-01-18T05:51:09.851Z",
    "dateReserved": "2022-06-23T18:55:17.099Z",
    "dateUpdated": "2025-04-03T19:42:05.249Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}