Search

Find a vulnerability

Search criteria

    6 vulnerabilities found for airstation_whr-g54s_firmware by buffalo

    FKIE_CVE-2020-5606

    Vulnerability from fkie_nvd - Published: 2020-09-18 06:15 - Updated: 2026-06-17 03:21
    Summary
    Cross-site scripting vulnerability in WHR-G54S firmware 1.43 and earlier allows remote attackers to inject arbitrary script via a specially crafted page.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "WHR-G54S",
              "vendor": "BUFFALO INC.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware 1.43 and earlier"
                }
              ]
            }
          ],
          "source": "vultures@jpcert.or.jp"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:buffalo:airstation_whr-g54s_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "19069258-DC9D-4F29-BE18-F10E299E2706",
                  "versionEndIncluding": "1.43",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:buffalo:airstation_whr-g54s:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D5758901-4AA6-4F8A-ADA0-D642F1511220",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Cross-site scripting vulnerability in WHR-G54S firmware 1.43 and earlier allows remote attackers to inject arbitrary script via a specially crafted page."
        },
        {
          "lang": "es",
          "value": "Una vulnerabilidad de tipo Cross-site scripting en WHR-G54S versi\u00f3n de firmware 1.43 y anteriores, permite a atacantes remotos inyectar script arbitrario por medio de una p\u00e1gina especialmente dise\u00f1ada"
        }
      ],
      "id": "CVE-2020-5606",
      "lastModified": "2026-06-17T03:21:41.040",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.1,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 2.7,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-09-18T06:15:13.417",
      "references": [
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/en/jp/JVN09166495/index.html"
        },
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.buffalo.jp/news/detail/20200911-01.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/en/jp/JVN09166495/index.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.buffalo.jp/news/detail/20200911-01.html"
        }
      ],
      "sourceIdentifier": "vultures@jpcert.or.jp",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-79"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-5605

    Vulnerability from fkie_nvd - Published: 2020-09-18 06:15 - Updated: 2026-06-17 03:21
    Summary
    Directory traversal vulnerability in WHR-G54S firmware 1.43 and earlier allows an attacker to access sensitive information such as setting values via unspecified vectors.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "WHR-G54S",
              "vendor": "BUFFALO INC.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware 1.43 and earlier"
                }
              ]
            }
          ],
          "source": "vultures@jpcert.or.jp"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:buffalo:airstation_whr-g54s_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "19069258-DC9D-4F29-BE18-F10E299E2706",
                  "versionEndIncluding": "1.43",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:buffalo:airstation_whr-g54s:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D5758901-4AA6-4F8A-ADA0-D642F1511220",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Directory traversal vulnerability in WHR-G54S firmware 1.43 and earlier allows an attacker to access sensitive information such as setting values via unspecified vectors."
        },
        {
          "lang": "es",
          "value": "Una vulnerabilidad de Salto de Directorio en WHR-G54S versi\u00f3n de firmware 1.43 y anteriores, permite a un atacante acceder a informaci\u00f3n confidencial, tal y como valores de configuraci\u00f3n por medio de vectores no especificados"
        }
      ],
      "id": "CVE-2020-5605",
      "lastModified": "2026-06-17T03:21:40.937",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 4.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-09-18T06:15:13.357",
      "references": [
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/en/jp/JVN09166495/index.html"
        },
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.buffalo.jp/news/detail/20200911-01.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/en/jp/JVN09166495/index.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.buffalo.jp/news/detail/20200911-01.html"
        }
      ],
      "sourceIdentifier": "vultures@jpcert.or.jp",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-22"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2020-5606 (GCVE-0-2020-5606)

    Vulnerability from nvd – Published: 2020-09-18 05:05 – Updated: 2024-08-04 08:30
    VLAI
    Summary
    Cross-site scripting vulnerability in WHR-G54S firmware 1.43 and earlier allows remote attackers to inject arbitrary script via a specially crafted page.
    Severity
    No CVSS data available.
    CWE
    • Cross-site scripting
    Assigner
    jpcert CNA under the jpcert root
    CNA scorecard C 64/100 over 195 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    BUFFALO INC. WHR-G54S Affected: firmware 1.43 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:30:24.615Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.buffalo.jp/news/detail/20200911-01.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN09166495/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "WHR-G54S",
              "vendor": "BUFFALO INC.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware 1.43 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site scripting vulnerability in WHR-G54S firmware 1.43 and earlier allows remote attackers to inject arbitrary script via a specially crafted page."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Cross-site scripting",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-09-18T05:05:24.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.buffalo.jp/news/detail/20200911-01.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/en/jp/JVN09166495/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2020-5606",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "WHR-G54S",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "firmware 1.43 and earlier"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "BUFFALO INC."
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site scripting vulnerability in WHR-G54S firmware 1.43 and earlier allows remote attackers to inject arbitrary script via a specially crafted page."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Cross-site scripting"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.buffalo.jp/news/detail/20200911-01.html",
                  "refsource": "MISC",
                  "url": "https://www.buffalo.jp/news/detail/20200911-01.html"
                },
                {
                  "name": "https://jvn.jp/en/jp/JVN09166495/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/en/jp/JVN09166495/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2020-5606",
        "datePublished": "2020-09-18T05:05:24.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:30:24.615Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5605 (GCVE-0-2020-5605)

    Vulnerability from nvd – Published: 2020-09-18 05:05 – Updated: 2024-08-04 08:30
    VLAI
    Summary
    Directory traversal vulnerability in WHR-G54S firmware 1.43 and earlier allows an attacker to access sensitive information such as setting values via unspecified vectors.
    Severity
    No CVSS data available.
    CWE
    • Directory traversal
    Assigner
    jpcert CNA under the jpcert root
    CNA scorecard C 64/100 over 195 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    BUFFALO INC. WHR-G54S Affected: firmware 1.43 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:30:24.565Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.buffalo.jp/news/detail/20200911-01.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN09166495/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "WHR-G54S",
              "vendor": "BUFFALO INC.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware 1.43 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Directory traversal vulnerability in WHR-G54S firmware 1.43 and earlier allows an attacker to access sensitive information such as setting values via unspecified vectors."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Directory traversal",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-09-18T05:05:24.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.buffalo.jp/news/detail/20200911-01.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/en/jp/JVN09166495/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2020-5605",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "WHR-G54S",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "firmware 1.43 and earlier"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "BUFFALO INC."
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Directory traversal vulnerability in WHR-G54S firmware 1.43 and earlier allows an attacker to access sensitive information such as setting values via unspecified vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Directory traversal"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.buffalo.jp/news/detail/20200911-01.html",
                  "refsource": "MISC",
                  "url": "https://www.buffalo.jp/news/detail/20200911-01.html"
                },
                {
                  "name": "https://jvn.jp/en/jp/JVN09166495/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/en/jp/JVN09166495/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2020-5605",
        "datePublished": "2020-09-18T05:05:24.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:30:24.565Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5605 (GCVE-0-2020-5605)

    Vulnerability from cvelistv5 – Published: 2020-09-18 05:05 – Updated: 2024-08-04 08:30
    VLAI
    Summary
    Directory traversal vulnerability in WHR-G54S firmware 1.43 and earlier allows an attacker to access sensitive information such as setting values via unspecified vectors.
    Severity
    No CVSS data available.
    CWE
    • Directory traversal
    Assigner
    jpcert CNA under the jpcert root
    CNA scorecard C 64/100 over 195 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    BUFFALO INC. WHR-G54S Affected: firmware 1.43 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:30:24.565Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.buffalo.jp/news/detail/20200911-01.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN09166495/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "WHR-G54S",
              "vendor": "BUFFALO INC.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware 1.43 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Directory traversal vulnerability in WHR-G54S firmware 1.43 and earlier allows an attacker to access sensitive information such as setting values via unspecified vectors."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Directory traversal",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-09-18T05:05:24.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.buffalo.jp/news/detail/20200911-01.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/en/jp/JVN09166495/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2020-5605",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "WHR-G54S",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "firmware 1.43 and earlier"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "BUFFALO INC."
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Directory traversal vulnerability in WHR-G54S firmware 1.43 and earlier allows an attacker to access sensitive information such as setting values via unspecified vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Directory traversal"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.buffalo.jp/news/detail/20200911-01.html",
                  "refsource": "MISC",
                  "url": "https://www.buffalo.jp/news/detail/20200911-01.html"
                },
                {
                  "name": "https://jvn.jp/en/jp/JVN09166495/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/en/jp/JVN09166495/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2020-5605",
        "datePublished": "2020-09-18T05:05:24.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:30:24.565Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5606 (GCVE-0-2020-5606)

    Vulnerability from cvelistv5 – Published: 2020-09-18 05:05 – Updated: 2024-08-04 08:30
    VLAI
    Summary
    Cross-site scripting vulnerability in WHR-G54S firmware 1.43 and earlier allows remote attackers to inject arbitrary script via a specially crafted page.
    Severity
    No CVSS data available.
    CWE
    • Cross-site scripting
    Assigner
    jpcert CNA under the jpcert root
    CNA scorecard C 64/100 over 195 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    BUFFALO INC. WHR-G54S Affected: firmware 1.43 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:30:24.615Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.buffalo.jp/news/detail/20200911-01.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN09166495/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "WHR-G54S",
              "vendor": "BUFFALO INC.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware 1.43 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site scripting vulnerability in WHR-G54S firmware 1.43 and earlier allows remote attackers to inject arbitrary script via a specially crafted page."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Cross-site scripting",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-09-18T05:05:24.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.buffalo.jp/news/detail/20200911-01.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/en/jp/JVN09166495/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2020-5606",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "WHR-G54S",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "firmware 1.43 and earlier"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "BUFFALO INC."
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site scripting vulnerability in WHR-G54S firmware 1.43 and earlier allows remote attackers to inject arbitrary script via a specially crafted page."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Cross-site scripting"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.buffalo.jp/news/detail/20200911-01.html",
                  "refsource": "MISC",
                  "url": "https://www.buffalo.jp/news/detail/20200911-01.html"
                },
                {
                  "name": "https://jvn.jp/en/jp/JVN09166495/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/en/jp/JVN09166495/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2020-5606",
        "datePublished": "2020-09-18T05:05:24.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:30:24.615Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }