Search criteria
6 vulnerabilities found for access_easy_controller_firmware by bosch
CVE-2021-23859 (GCVE-0-2021-23859)
Vulnerability from nvd – Published: 2021-12-08 21:17 – Updated: 2024-09-16 19:45
VLAI?
Title
Denial of Service and Authentication Bypass Vulnerability in multiple Bosch products
Summary
An unauthenticated attacker is able to send a special HTTP request, that causes a service to crash. In case of a standalone VRM or BVMS with VRM installation this crash also opens the possibility to send further unauthenticated commands to the service. On some products the interface is only local accessible lowering the CVSS base score. For a list of modified CVSS scores, please see the official Bosch Advisory Appendix chapter Modified CVSS Scores for CVE-2021-23859
Severity ?
9.1 (Critical)
CWE
- CWE-703 - Improper Check or Handling of Exceptional Conditions
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bosch | BVMS |
Affected:
unspecified , ≤ 9.0.0
(custom)
Affected: 11.0 , < 11.0.0 (custom) Affected: 10.0 , < 10.0.2 (custom) Affected: 10.1 , < 10.1.1 (custom) |
||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T19:14:09.402Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "BVMS",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "9.0.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThan": "11.0.0",
"status": "affected",
"version": "11.0",
"versionType": "custom"
},
{
"lessThan": "10.0.2",
"status": "affected",
"version": "10.0",
"versionType": "custom"
},
{
"lessThan": "10.1.1",
"status": "affected",
"version": "10.1",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP 7000 R2",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "DIVAR IP all-in-one 5000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "DIVAR IP all-in-one 7000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "VRM",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "3.81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.00.0070",
"status": "affected",
"version": "4.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "3.83.0021",
"status": "affected",
"version": "3.83",
"versionType": "custom"
},
{
"lessThanOrEqual": "3.82.0057",
"status": "affected",
"version": "3.82",
"versionType": "custom"
}
]
},
{
"product": "VRM Exporter",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "2.10.0008",
"status": "affected",
"version": "2.1",
"versionType": "custom"
}
]
},
{
"product": "APE",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "3.8.x.x",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "AEC",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "2.9.1.x",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "BIS",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "4.9",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.8",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-12-08T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "An unauthenticated attacker is able to send a special HTTP request, that causes a service to crash. In case of a standalone VRM or BVMS with VRM installation this crash also opens the possibility to send further unauthenticated commands to the service. On some products the interface is only local accessible lowering the CVSS base score. For a list of modified CVSS scores, please see the official Bosch Advisory Appendix chapter Modified CVSS Scores for CVE-2021-23859"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-703",
"description": "CWE-703 Improper Check or Handling of Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-08T21:17:23",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html"
}
],
"source": {
"advisory": "BOSCH-SA-043434-BT",
"discovery": "EXTERNAL"
},
"title": "Denial of Service and Authentication Bypass Vulnerability in multiple Bosch products",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2021-12-08",
"ID": "CVE-2021-23859",
"STATE": "PUBLIC",
"TITLE": "Denial of Service and Authentication Bypass Vulnerability in multiple Bosch products"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "BVMS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "11.0",
"version_value": "11.0.0"
},
{
"version_affected": "\u003c",
"version_name": "10.0",
"version_value": "10.0.2"
},
{
"version_affected": "\u003c",
"version_name": "10.1",
"version_value": "10.1.1"
},
{
"version_affected": "\u003c=",
"version_value": "9.0.0"
}
]
}
},
{
"product_name": "DIVAR IP 7000 R2",
"version": {
"version_data": [
{
"configuration": "using vulnerable BVMS version",
"version_affected": "=",
"version_value": "all"
}
]
}
},
{
"product_name": "DIVAR IP all-in-one 5000",
"version": {
"version_data": [
{
"configuration": "using vulnerable BVMS or VRM version",
"version_affected": "=",
"version_value": "all"
}
]
}
},
{
"product_name": "DIVAR IP all-in-one 7000",
"version": {
"version_data": [
{
"configuration": "using vulnerable BVMS or VRM version",
"version_affected": "=",
"version_value": "all"
}
]
}
},
{
"product_name": "VRM",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "4.0",
"version_value": "4.00.0070"
},
{
"version_affected": "\u003c=",
"version_name": "3.83",
"version_value": "3.83.0021"
},
{
"version_affected": "\u003c=",
"version_name": "3.82",
"version_value": "3.82.0057"
},
{
"version_affected": "\u003c=",
"version_value": "3.81"
}
]
}
},
{
"product_name": "VRM Exporter",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "2.1",
"version_value": "2.10.0008"
}
]
}
},
{
"product_name": "APE",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "3.8.x.x"
}
]
}
},
{
"product_name": "AEC",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "2.9.1.x"
}
]
}
},
{
"product_name": "BIS",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "4.9"
},
{
"version_affected": "\u003c=",
"version_value": "4.8"
},
{
"version_affected": "\u003c=",
"version_value": "4.7"
}
]
}
}
]
},
"vendor_name": "Bosch"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An unauthenticated attacker is able to send a special HTTP request, that causes a service to crash. In case of a standalone VRM or BVMS with VRM installation this crash also opens the possibility to send further unauthenticated commands to the service. On some products the interface is only local accessible lowering the CVSS base score. For a list of modified CVSS scores, please see the official Bosch Advisory Appendix chapter Modified CVSS Scores for CVE-2021-23859"
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-703 Improper Check or Handling of Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-043434-BT",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2021-23859",
"datePublished": "2021-12-08T21:17:23.528438Z",
"dateReserved": "2021-01-12T00:00:00",
"dateUpdated": "2024-09-16T19:45:43.543Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6958 (GCVE-0-2019-6958)
Vulnerability from nvd – Published: 2019-05-29 18:47 – Updated: 2024-09-17 00:46
VLAI?
Title
Improper Access Control for Bosch Video Systems, PSIM and Access Control Systems
Summary
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as "CWE-284: Improper Access Control." This vulnerability, for example, allows a potential attacker to delete video or read video data.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.392Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2019-03-04T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as \"CWE-284: Improper Access Control.\" This vulnerability, for example, allows a potential attacker to delete video or read video data."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-29T18:47:37",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf"
}
],
"solutions": [
{
"lang": "en",
"value": "The recommended approach is to update the software to a fixed version as soon as possible. Until a fixed software version is installed, the mitigation approaches firewalling, and IP filtering can be utilized. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Improper Access Control for Bosch Video Systems, PSIM and Access Control Systems",
"x_generator": {
"engine": "Vulnogram 0.0.6"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"DATE_PUBLIC": "2019-03-04T23:00:00.000Z",
"ID": "CVE-2019-6958",
"STATE": "PUBLIC",
"TITLE": "Improper Access Control for Bosch Video Systems, PSIM and Access Control Systems"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as \"CWE-284: Improper Access Control.\" This vulnerability, for example, allows a potential attacker to delete video or read video data."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.6"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf",
"refsource": "CONFIRM",
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf"
}
]
},
"solution": [
{
"lang": "en",
"value": "The recommended approach is to update the software to a fixed version as soon as possible. Until a fixed software version is installed, the mitigation approaches firewalling, and IP filtering can be utilized. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-6958",
"datePublished": "2019-05-29T18:47:37.354175Z",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-09-17T00:46:00.474Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6957 (GCVE-0-2019-6957)
Vulnerability from nvd – Published: 2019-05-29 18:55 – Updated: 2024-09-16 16:38
VLAI?
Title
Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems
Summary
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.396Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2019-04-04T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-29T18:55:20",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
}
],
"solutions": [
{
"lang": "en",
"value": "In cases where a software update is not possible, a reduction in the system\u2019s network exposure is advised. Internet-accessible installations should be firewalled, whilst additional steps like network isolation by VLAN, IP filtering features of the devices and other technologies should be used to decrease the exposure of vulnerable systems. In addition the firewall on the hosts shall be activated and set according to BVMS and BIS configuration manual. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems",
"x_generator": {
"engine": "Vulnogram 0.0.6"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"DATE_PUBLIC": "2019-04-04T22:00:00.000Z",
"ID": "CVE-2019-6957",
"STATE": "PUBLIC",
"TITLE": "Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.6"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf",
"refsource": "CONFIRM",
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
}
]
},
"solution": [
{
"lang": "en",
"value": "In cases where a software update is not possible, a reduction in the system\u2019s network exposure is advised. Internet-accessible installations should be firewalled, whilst additional steps like network isolation by VLAN, IP filtering features of the devices and other technologies should be used to decrease the exposure of vulnerable systems. In addition the firewall on the hosts shall be activated and set according to BVMS and BIS configuration manual. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-6957",
"datePublished": "2019-05-29T18:55:20.387906Z",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-09-16T16:38:39.411Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-23859 (GCVE-0-2021-23859)
Vulnerability from cvelistv5 – Published: 2021-12-08 21:17 – Updated: 2024-09-16 19:45
VLAI?
Title
Denial of Service and Authentication Bypass Vulnerability in multiple Bosch products
Summary
An unauthenticated attacker is able to send a special HTTP request, that causes a service to crash. In case of a standalone VRM or BVMS with VRM installation this crash also opens the possibility to send further unauthenticated commands to the service. On some products the interface is only local accessible lowering the CVSS base score. For a list of modified CVSS scores, please see the official Bosch Advisory Appendix chapter Modified CVSS Scores for CVE-2021-23859
Severity ?
9.1 (Critical)
CWE
- CWE-703 - Improper Check or Handling of Exceptional Conditions
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bosch | BVMS |
Affected:
unspecified , ≤ 9.0.0
(custom)
Affected: 11.0 , < 11.0.0 (custom) Affected: 10.0 , < 10.0.2 (custom) Affected: 10.1 , < 10.1.1 (custom) |
||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T19:14:09.402Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "BVMS",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "9.0.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThan": "11.0.0",
"status": "affected",
"version": "11.0",
"versionType": "custom"
},
{
"lessThan": "10.0.2",
"status": "affected",
"version": "10.0",
"versionType": "custom"
},
{
"lessThan": "10.1.1",
"status": "affected",
"version": "10.1",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP 7000 R2",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "DIVAR IP all-in-one 5000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "DIVAR IP all-in-one 7000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "VRM",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "3.81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.00.0070",
"status": "affected",
"version": "4.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "3.83.0021",
"status": "affected",
"version": "3.83",
"versionType": "custom"
},
{
"lessThanOrEqual": "3.82.0057",
"status": "affected",
"version": "3.82",
"versionType": "custom"
}
]
},
{
"product": "VRM Exporter",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "2.10.0008",
"status": "affected",
"version": "2.1",
"versionType": "custom"
}
]
},
{
"product": "APE",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "3.8.x.x",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "AEC",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "2.9.1.x",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "BIS",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "4.9",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.8",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-12-08T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "An unauthenticated attacker is able to send a special HTTP request, that causes a service to crash. In case of a standalone VRM or BVMS with VRM installation this crash also opens the possibility to send further unauthenticated commands to the service. On some products the interface is only local accessible lowering the CVSS base score. For a list of modified CVSS scores, please see the official Bosch Advisory Appendix chapter Modified CVSS Scores for CVE-2021-23859"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-703",
"description": "CWE-703 Improper Check or Handling of Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-08T21:17:23",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html"
}
],
"source": {
"advisory": "BOSCH-SA-043434-BT",
"discovery": "EXTERNAL"
},
"title": "Denial of Service and Authentication Bypass Vulnerability in multiple Bosch products",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2021-12-08",
"ID": "CVE-2021-23859",
"STATE": "PUBLIC",
"TITLE": "Denial of Service and Authentication Bypass Vulnerability in multiple Bosch products"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "BVMS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "11.0",
"version_value": "11.0.0"
},
{
"version_affected": "\u003c",
"version_name": "10.0",
"version_value": "10.0.2"
},
{
"version_affected": "\u003c",
"version_name": "10.1",
"version_value": "10.1.1"
},
{
"version_affected": "\u003c=",
"version_value": "9.0.0"
}
]
}
},
{
"product_name": "DIVAR IP 7000 R2",
"version": {
"version_data": [
{
"configuration": "using vulnerable BVMS version",
"version_affected": "=",
"version_value": "all"
}
]
}
},
{
"product_name": "DIVAR IP all-in-one 5000",
"version": {
"version_data": [
{
"configuration": "using vulnerable BVMS or VRM version",
"version_affected": "=",
"version_value": "all"
}
]
}
},
{
"product_name": "DIVAR IP all-in-one 7000",
"version": {
"version_data": [
{
"configuration": "using vulnerable BVMS or VRM version",
"version_affected": "=",
"version_value": "all"
}
]
}
},
{
"product_name": "VRM",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "4.0",
"version_value": "4.00.0070"
},
{
"version_affected": "\u003c=",
"version_name": "3.83",
"version_value": "3.83.0021"
},
{
"version_affected": "\u003c=",
"version_name": "3.82",
"version_value": "3.82.0057"
},
{
"version_affected": "\u003c=",
"version_value": "3.81"
}
]
}
},
{
"product_name": "VRM Exporter",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "2.1",
"version_value": "2.10.0008"
}
]
}
},
{
"product_name": "APE",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "3.8.x.x"
}
]
}
},
{
"product_name": "AEC",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "2.9.1.x"
}
]
}
},
{
"product_name": "BIS",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "4.9"
},
{
"version_affected": "\u003c=",
"version_value": "4.8"
},
{
"version_affected": "\u003c=",
"version_value": "4.7"
}
]
}
}
]
},
"vendor_name": "Bosch"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An unauthenticated attacker is able to send a special HTTP request, that causes a service to crash. In case of a standalone VRM or BVMS with VRM installation this crash also opens the possibility to send further unauthenticated commands to the service. On some products the interface is only local accessible lowering the CVSS base score. For a list of modified CVSS scores, please see the official Bosch Advisory Appendix chapter Modified CVSS Scores for CVE-2021-23859"
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-703 Improper Check or Handling of Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-043434-BT",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2021-23859",
"datePublished": "2021-12-08T21:17:23.528438Z",
"dateReserved": "2021-01-12T00:00:00",
"dateUpdated": "2024-09-16T19:45:43.543Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6957 (GCVE-0-2019-6957)
Vulnerability from cvelistv5 – Published: 2019-05-29 18:55 – Updated: 2024-09-16 16:38
VLAI?
Title
Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems
Summary
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.396Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2019-04-04T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-29T18:55:20",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
}
],
"solutions": [
{
"lang": "en",
"value": "In cases where a software update is not possible, a reduction in the system\u2019s network exposure is advised. Internet-accessible installations should be firewalled, whilst additional steps like network isolation by VLAN, IP filtering features of the devices and other technologies should be used to decrease the exposure of vulnerable systems. In addition the firewall on the hosts shall be activated and set according to BVMS and BIS configuration manual. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems",
"x_generator": {
"engine": "Vulnogram 0.0.6"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"DATE_PUBLIC": "2019-04-04T22:00:00.000Z",
"ID": "CVE-2019-6957",
"STATE": "PUBLIC",
"TITLE": "Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.6"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf",
"refsource": "CONFIRM",
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
}
]
},
"solution": [
{
"lang": "en",
"value": "In cases where a software update is not possible, a reduction in the system\u2019s network exposure is advised. Internet-accessible installations should be firewalled, whilst additional steps like network isolation by VLAN, IP filtering features of the devices and other technologies should be used to decrease the exposure of vulnerable systems. In addition the firewall on the hosts shall be activated and set according to BVMS and BIS configuration manual. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-6957",
"datePublished": "2019-05-29T18:55:20.387906Z",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-09-16T16:38:39.411Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6958 (GCVE-0-2019-6958)
Vulnerability from cvelistv5 – Published: 2019-05-29 18:47 – Updated: 2024-09-17 00:46
VLAI?
Title
Improper Access Control for Bosch Video Systems, PSIM and Access Control Systems
Summary
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as "CWE-284: Improper Access Control." This vulnerability, for example, allows a potential attacker to delete video or read video data.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.392Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2019-03-04T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as \"CWE-284: Improper Access Control.\" This vulnerability, for example, allows a potential attacker to delete video or read video data."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-29T18:47:37",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf"
}
],
"solutions": [
{
"lang": "en",
"value": "The recommended approach is to update the software to a fixed version as soon as possible. Until a fixed software version is installed, the mitigation approaches firewalling, and IP filtering can be utilized. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Improper Access Control for Bosch Video Systems, PSIM and Access Control Systems",
"x_generator": {
"engine": "Vulnogram 0.0.6"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"DATE_PUBLIC": "2019-03-04T23:00:00.000Z",
"ID": "CVE-2019-6958",
"STATE": "PUBLIC",
"TITLE": "Improper Access Control for Bosch Video Systems, PSIM and Access Control Systems"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as \"CWE-284: Improper Access Control.\" This vulnerability, for example, allows a potential attacker to delete video or read video data."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.6"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf",
"refsource": "CONFIRM",
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf"
}
]
},
"solution": [
{
"lang": "en",
"value": "The recommended approach is to update the software to a fixed version as soon as possible. Until a fixed software version is installed, the mitigation approaches firewalling, and IP filtering can be utilized. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-6958",
"datePublished": "2019-05-29T18:47:37.354175Z",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-09-17T00:46:00.474Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}