    VAR-202512-0198

    Vulnerability from variot - Updated: 2025-12-19 22:48

    A vulnerability was determined in Tenda AC9 15.03.05.14_multi. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/DownloadCfg.jpg of the component Configuration File Handler. This manipulation causes information disclosure. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202512-0198",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.05.14_multi"
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-14286"
          }
        ]
      },
      "cve": "CVE-2025-14286",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2025-14286",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-14286",
                "impactScore": 1.4,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-14286",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-14286",
                "trust": 1.0,
                "value": "Medium"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-14286",
                "trust": 1.0,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-14286"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-14286"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was determined in Tenda AC9 15.03.05.14_multi. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/DownloadCfg.jpg of the component Configuration File Handler. This manipulation causes information disclosure. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-14286"
          }
        ],
        "trust": 1.0
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "VULDB",
            "id": "334874",
            "trust": 1.0
          },
          {
            "db": "NVD",
            "id": "CVE-2025-14286",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-14286"
          }
        ]
      },
      "id": "VAR-202512-0198",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.43844455
      },
      "last_update_date": "2025-12-19T22:48:28.850000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-200",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-284",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-14286"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?id.334874"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.334874"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?submit.702723"
          },
          {
            "trust": 1.0,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.0,
            "url": "https://github.com/madgeaaaaa/my_vuln_2/blob/main/tenda/vuln11.md"
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-14286"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-14286"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-12-09T16:17:38.197000",
            "db": "NVD",
            "id": "CVE-2025-14286"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-12-11T17:15:12.343000",
            "db": "NVD",
            "id": "CVE-2025-14286"
          }
        ]
      }
    }

    VAR-201810-0977

    Vulnerability from variot - Updated: 2025-11-18 15:28

    An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input. Tenda AC7 , AC9 ,and AC10 The firmware contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Tenda AC7, AC9 and AC10 are all wireless router products from China Tenda.

    Tenda AC7, AC9 and AC10 have command injection vulnerabilities. The following products and versions are affected: Tenda AC7 (using firmware 15.03.06.44_CN and earlier); AC9 (using firmware 15.03.05.19(6318)_CN and earlier); AC10 (using firmware 15.03.06.23_CN and earlier)

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0977",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac10",
            "scope": "lte",
            "trust": 1.8,
            "vendor": "tenda",
            "version": "15.03.06.23_cn"
          },
          {
            "model": "ac7",
            "scope": "lte",
            "trust": 1.8,
            "vendor": "tenda",
            "version": "15.03.06.44_cn"
          },
          {
            "model": "ac9",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.05.19\\(6318\\)_cn"
          },
          {
            "model": "ac9",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "15.03.05.19(6318)_cn"
          },
          {
            "model": "ac7 \u003c=15.03.06.44 cn",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac10 \u003c=15.03.06.23 cn",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9 \u003c=15.03.05.19 cn",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14558"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          }
        ]
      },
      "cve": "CVE-2018-14558",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2018-14558",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.9,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2020-35174",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "VHN-124729",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2018-14558",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2018-14558",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2018-14558",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2018-14558",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2018-14558",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2020-35174",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201810-1439",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-124729",
                "trust": 0.1,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2018-14558",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124729"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14558"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201810-1439"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14558"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14558"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the \"formsetUsbUnload\" function executes a dosystemCmd function with untrusted input. Tenda AC7 , AC9 ,and AC10 The firmware contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Tenda AC7, AC9 and AC10 are all wireless router products from China Tenda. \n\r\n\r\nTenda AC7, AC9 and AC10 have command injection vulnerabilities. The following products and versions are affected: Tenda AC7 (using firmware 15.03.06.44_CN and earlier); AC9 (using firmware 15.03.05.19(6318)_CN and earlier); AC10 (using firmware 15.03.06.23_CN and earlier)",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-14558"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124729"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14558"
          }
        ],
        "trust": 2.34
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-14558",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201810-1439",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-35174",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-124729",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14558",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124729"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14558"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201810-1439"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14558"
          }
        ]
      },
      "id": "VAR-201810-0977",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124729"
          }
        ],
        "trust": 1.440988034
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          }
        ]
      },
      "last_update_date": "2025-11-18T15:28:39.538000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://www.tenda.com.cn/"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.1
          },
          {
            "problemtype": "CWE-77",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-124729"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14558"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.6,
            "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/tenda.md"
          },
          {
            "trust": 1.0,
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=cve-2018-14558"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14558"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14558"
          },
          {
            "trust": 0.6,
            "url": "http://www.cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14558"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/78.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124729"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14558"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201810-1439"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14558"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124729"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14558"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201810-1439"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14558"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-06-30T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          },
          {
            "date": "2018-10-30T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124729"
          },
          {
            "date": "2018-10-30T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-14558"
          },
          {
            "date": "2018-10-31T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201810-1439"
          },
          {
            "date": "2019-03-07T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          },
          {
            "date": "2018-10-30T18:29:00.580000",
            "db": "NVD",
            "id": "CVE-2018-14558"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-06-30T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          },
          {
            "date": "2019-10-03T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124729"
          },
          {
            "date": "2019-10-03T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-14558"
          },
          {
            "date": "2019-10-23T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201810-1439"
          },
          {
            "date": "2019-03-07T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          },
          {
            "date": "2025-11-07T19:14:06.623000",
            "db": "NVD",
            "id": "CVE-2018-14558"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201810-1439"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  Tenda Command injection vulnerability in product firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "operating system commend injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201810-1439"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202509-3634

    Vulnerability from variot - Updated: 2025-10-03 19:36

    OS Command injection vulnerability in Tenda AC9 1.0 was discovered to contain a command injection vulnerability via the usb.samba.guest.user parameter in the formSetSambaConf function of the httpd file. Shenzhen Tenda Technology Co.,Ltd

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202509-3634",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0"
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  1.0"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014847"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57639"
          }
        ]
      },
      "cve": "CVE-2025-57639",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-57639",
                "impactScore": 2.5,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "None",
                "baseScore": 6.5,
                "baseSeverity": "Medium",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-014847",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-57639",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-014847",
                "trust": 0.8,
                "value": "Medium"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014847"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57639"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "OS Command injection vulnerability in Tenda AC9 1.0 was discovered to contain a command injection vulnerability via the usb.samba.guest.user parameter in the formSetSambaConf function of the httpd file. Shenzhen Tenda Technology Co.,Ltd",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-57639"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014847"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-57639",
            "trust": 2.6
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014847",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014847"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57639"
          }
        ]
      },
      "id": "VAR-202509-3634",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.43844455
      },
      "last_update_date": "2025-10-03T19:36:42.951000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.0
          },
          {
            "problemtype": "OS Command injection (CWE-78) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014847"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57639"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/glkfc/iot-vulnerability/blob/main/tenda/tenda2.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-57639"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014847"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57639"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014847"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57639"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-01T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014847"
          },
          {
            "date": "2025-09-23T18:15:35.593000",
            "db": "NVD",
            "id": "CVE-2025-57639"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-01T08:11:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014847"
          },
          {
            "date": "2025-09-25T16:09:17.580000",
            "db": "NVD",
            "id": "CVE-2025-57639"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 in the firmware \u00a0OS\u00a0 Command injection vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014847"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202509-1490

    Vulnerability from variot - Updated: 2025-09-26 23:41

    A vulnerability was determined in Tenda AC9 and AC15 15.03.05.14. This affects the function formexeCommand of the file /goform/exeCommand. This manipulation of the argument cmdinput causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware and AC15 The firmware contains a command injection vulnerability. OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202509-1490",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.05.14"
          },
          {
            "model": "ac15",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.05.14"
          },
          {
            "model": "ac15",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014433"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-10442"
          }
        ]
      },
      "cve": "CVE-2025-10442",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-10442",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Partial",
                "baseScore": 6.5,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-014433",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "LOW",
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-10442",
                "impactScore": 3.4,
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-10442",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-014433",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-10442",
                "trust": 1.0,
                "value": "Low"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-10442",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-014433",
                "trust": 0.8,
                "value": "High"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014433"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-10442"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-10442"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was determined in Tenda AC9 and AC15 15.03.05.14. This affects the function formexeCommand of the file /goform/exeCommand. This manipulation of the argument cmdinput causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware and AC15 The firmware contains a command injection vulnerability. OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-10442"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014433"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-10442",
            "trust": 2.6
          },
          {
            "db": "VULDB",
            "id": "323876",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014433",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014433"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-10442"
          }
        ]
      },
      "id": "VAR-202509-1490",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.422403305
      },
      "last_update_date": "2025-09-26T23:41:52.051000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": "OS Command injection (CWE-78) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014433"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-10442"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/2664521593/mycve/blob/main/tenda/tenda_ac9_cj.md"
          },
          {
            "trust": 1.8,
            "url": "https://github.com/2664521593/mycve/blob/main/tenda/tenda_ac9_cj.md#poc"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.323876"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.647838"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.647839"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.323876"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-10442"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014433"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-10442"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014433"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-10442"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-25T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014433"
          },
          {
            "date": "2025-09-15T11:15:33.970000",
            "db": "NVD",
            "id": "CVE-2025-10442"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-25T01:26:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014433"
          },
          {
            "date": "2025-09-19T20:39:12.093000",
            "db": "NVD",
            "id": "CVE-2025-10442"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 firmware and \u00a0AC15\u00a0 Command injection vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014433"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202509-1917

    Vulnerability from variot - Updated: 2025-09-25 23:17

    Buffer overflow vulnerability in Tenda AC9 1.0 via the user supplied sys.vendor configuration value.

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202509-1917",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-57638"
          }
        ]
      },
      "cve": "CVE-2025-57638",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-57638",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-57638",
                "trust": 1.0,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-57638"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Buffer overflow vulnerability in Tenda AC9 1.0 via the user supplied sys.vendor configuration value.",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-57638"
          }
        ],
        "trust": 1.0
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-57638",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-57638"
          }
        ]
      },
      "id": "VAR-202509-1917",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.43844455
      },
      "last_update_date": "2025-09-25T23:17:20.111000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-122",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-57638"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://github.com/glkfc/iot-vulnerability/blob/main/tenda/tenda1.md"
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-57638"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-57638"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-23T19:15:41.437000",
            "db": "NVD",
            "id": "CVE-2025-57638"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-25T16:09:10.880000",
            "db": "NVD",
            "id": "CVE-2025-57638"
          }
        ]
      }
    }

    VAR-202509-1516

    Vulnerability from variot - Updated: 2025-09-20 23:23

    A vulnerability was identified in Tenda AC9 and AC15 15.03.05.14/15.03.05.18. This vulnerability affects the function formexeCommand of the file /goform/exeCommand. Such manipulation of the argument cmdinput leads to buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used.

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202509-1516",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac15",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.05.18"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.05.14"
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-10443"
          }
        ]
      },
      "cve": "CVE-2025-10443",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-10443",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-10443",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-10443",
                "trust": 1.0,
                "value": "High"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-10443"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was identified in Tenda AC9 and AC15 15.03.05.14/15.03.05.18. This vulnerability affects the function formexeCommand of the file /goform/exeCommand. Such manipulation of the argument cmdinput leads to buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used.",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-10443"
          }
        ],
        "trust": 1.0
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "VULDB",
            "id": "323877",
            "trust": 1.0
          },
          {
            "db": "NVD",
            "id": "CVE-2025-10443",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-10443"
          }
        ]
      },
      "id": "VAR-202509-1516",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.422403305
      },
      "last_update_date": "2025-09-20T23:23:28.217000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-10443"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://github.com/2664521593/mycve/blob/main/tenda/tenda_ac15_ac9_bof.md"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?submit.647840"
          },
          {
            "trust": 1.0,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.0,
            "url": "https://github.com/2664521593/mycve/blob/main/tenda/tenda_ac15_ac9_bof.md#poc"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?id.323877"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.323877"
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-10443"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-10443"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-15T12:15:32.690000",
            "db": "NVD",
            "id": "CVE-2025-10443"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-19T19:22:53.663000",
            "db": "NVD",
            "id": "CVE-2025-10443"
          }
        ]
      }
    }

    VAR-202508-2475

    Vulnerability from variot - Updated: 2025-09-10 23:43

    A vulnerability was determined in Tenda AC9 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/shadow of the component Administrative Interface. This manipulation causes hard-coded credentials. It is possible to launch the attack on the local host. The attack's complexity is rated as high. The exploitability is regarded as difficult. The exploit has been publicly disclosed and may be utilized. Shenzhen Tenda Technology Co.,Ltd. of AC9 The firmware contains vulnerabilities related to the use of hard-coded passwords and vulnerabilities related to the use of hard-coded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. An attacker could exploit this vulnerability to compromise confidentiality

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202508-2475",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.05.19"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  15.03.05.19"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20273"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-013093"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-9731"
          }
        ]
      },
      "cve": "CVE-2025-9731",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "HIGH",
                "accessVector": "LOCAL",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "NONE",
                "baseScore": 1.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 1.5,
                "id": "CVE-2025-9731",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "LOW",
                "trust": 1.0,
                "vectorString": "AV:L/AC:H/Au:S/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "High",
                "accessVector": "Local",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "None",
                "baseScore": 1.0,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-013093",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Low",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:L/AC:H/Au:S/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "HIGH",
                "accessVector": "LOCAL",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 1.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 1.5,
                "id": "CNVD-2025-20273",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "LOW",
                "trust": 0.6,
                "vectorString": "AV:L/AC:H/Au:S/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "author": "cna@vuldb.com",
                "availabilityImpact": "NONE",
                "baseScore": 2.5,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 1.0,
                "id": "CVE-2025-9731",
                "impactScore": 1.4,
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.0,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.0,
                "id": "CVE-2025-9731",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "High",
                "attackVector": "Local",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.0,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-013093",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-9731",
                "trust": 1.0,
                "value": "Low"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-9731",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-013093",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-20273",
                "trust": 0.6,
                "value": "LOW"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20273"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-013093"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-9731"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-9731"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was determined in Tenda AC9 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/shadow of the component Administrative Interface. This manipulation causes hard-coded credentials. It is possible to launch the attack on the local host. The attack\u0027s complexity is rated as high. The exploitability is regarded as difficult. The exploit has been publicly disclosed and may be utilized. Shenzhen Tenda Technology Co.,Ltd. of AC9 The firmware contains vulnerabilities related to the use of hard-coded passwords and vulnerabilities related to the use of hard-coded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. An attacker could exploit this vulnerability to compromise confidentiality",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-9731"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-013093"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20273"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-9731",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "322022",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-013093",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20273",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20273"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-013093"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-9731"
          }
        ]
      },
      "id": "VAR-202508-2475",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20273"
          }
        ],
        "trust": 1.03844455
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20273"
          }
        ]
      },
      "last_update_date": "2025-09-10T23:43:17.308000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-259",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-798",
            "trust": 1.0
          },
          {
            "problemtype": "Using hardcoded passwords (CWE-259) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Use hard-coded credentials (CWE-798) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-013093"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-9731"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/august829/yu/blob/main/58ead8e7e08bfb0e4.md"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.322022"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.639748"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-9731"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.322022"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20273"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-013093"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-9731"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20273"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-013093"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-9731"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-04T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20273"
          },
          {
            "date": "2025-09-05T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-013093"
          },
          {
            "date": "2025-08-31T14:15:31.413000",
            "db": "NVD",
            "id": "CVE-2025-9731"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-04T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20273"
          },
          {
            "date": "2025-09-05T07:36:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-013093"
          },
          {
            "date": "2025-09-04T16:49:00.897000",
            "db": "NVD",
            "id": "CVE-2025-9731"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Hardcoded password usage vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-013093"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202402-2722

    Vulnerability from variot - Updated: 2025-09-07 23:18

    A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the fromSetSysTime function. Shenzhen Tenda Technology Co.,Ltd. of AC9 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

    The Tenda AC9 suffers from a buffer overflow vulnerability caused by a failure to check the input buffer size

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202402-2722",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "5.03.06.42_multi"
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  5.03.06.42 multi"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9 v15.03.06.42 multi",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "v3.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20281"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020474"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-25751"
          }
        ]
      },
      "cve": "CVE-2024-25751",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-20281",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2024-25751",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-020474",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-25751",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-020474",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-20281",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20281"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020474"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-25751"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the fromSetSysTime function. Shenzhen Tenda Technology Co.,Ltd. of AC9 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nThe Tenda AC9 suffers from a buffer overflow vulnerability caused by a failure to check the input buffer size",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-25751"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020474"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20281"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-25751",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020474",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20281",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20281"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020474"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-25751"
          }
        ]
      },
      "id": "VAR-202402-2722",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20281"
          }
        ],
        "trust": 1.319222275
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20281"
          }
        ]
      },
      "last_update_date": "2025-09-07T23:18:44.517000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020474"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-25751"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/timeseg/iot_cve/blob/main/tenda/ac9v3/0218/fromsetsystime.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-25751"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20281"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020474"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-25751"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20281"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020474"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-25751"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-04T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20281"
          },
          {
            "date": "2025-03-14T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020474"
          },
          {
            "date": "2024-02-26T22:15:07.053000",
            "db": "NVD",
            "id": "CVE-2024-25751"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-04T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20281"
          },
          {
            "date": "2025-03-14T05:50:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020474"
          },
          {
            "date": "2025-03-13T19:34:02.767000",
            "db": "NVD",
            "id": "CVE-2024-25751"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020474"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202402-3399

    Vulnerability from variot - Updated: 2025-09-07 23:03

    Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the add_white_node function. Shenzhen Tenda Technology Co.,Ltd. of AC9 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202402-3399",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "5.03.06.42_multi"
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  5.03.06.42 multi"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9 v15.03.06.42 multi",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "v3.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20282"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020475"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-25746"
          }
        ]
      },
      "cve": "CVE-2024-25746",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 8.3,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 6.5,
                "id": "CNVD-2025-20282",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-25746",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-020475",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-25746",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-020475",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-20282",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20282"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020475"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-25746"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the add_white_node function. Shenzhen Tenda Technology Co.,Ltd. of AC9 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-25746"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020475"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20282"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-25746",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020475",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20282",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20282"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020475"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-25746"
          }
        ]
      },
      "id": "VAR-202402-3399",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20282"
          }
        ],
        "trust": 1.319222275
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20282"
          }
        ]
      },
      "last_update_date": "2025-09-07T23:03:22.884000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020475"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-25746"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/timeseg/iot_cve/blob/main/tenda/ac9v3/0218/add_white_node.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-25746"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20282"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020475"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-25746"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20282"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020475"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-25746"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-04T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20282"
          },
          {
            "date": "2025-03-14T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020475"
          },
          {
            "date": "2024-02-22T22:15:47.253000",
            "db": "NVD",
            "id": "CVE-2024-25746"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-04T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20282"
          },
          {
            "date": "2025-03-14T05:50:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020475"
          },
          {
            "date": "2025-03-13T19:34:56.347000",
            "db": "NVD",
            "id": "CVE-2024-25746"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020475"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202506-0379

    Vulnerability from variot - Updated: 2025-07-17 23:49

    A vulnerability was found in Tenda AC9 15.03.02.13. It has been rated as critical. This issue affects the function formSetIptv of the file /goform/SetIPTVCfg of the component POST Request Handler. The manipulation of the argument list leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. of AC9 The firmware contains injection and command injection vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

    Tenda AC9 has a command injection vulnerability, which is caused by the failure of the parameter list in the file /goform/SetIPTVCfg to properly filter special characters and commands in the constructed command. No detailed vulnerability details are currently provided

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202506-0379",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.2.13"
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  15.03.2.13"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "15.03.02.13"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15726"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006541"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5836"
          }
        ]
      },
      "cve": "CVE-2025-5836",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-5836",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Partial",
                "baseScore": 6.5,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006541",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-15726",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "LOW",
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-5836",
                "impactScore": 3.4,
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "Low",
                "baseScore": 6.3,
                "baseSeverity": "Medium",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006541",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-5836",
                "trust": 1.0,
                "value": "Low"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-006541",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-15726",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15726"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006541"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5836"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was found in Tenda AC9 15.03.02.13. It has been rated as critical. This issue affects the function formSetIptv of the file /goform/SetIPTVCfg of the component POST Request Handler. The manipulation of the argument list leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. of AC9 The firmware contains injection and command injection vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nTenda AC9 has a command injection vulnerability, which is caused by the failure of the parameter list in the file /goform/SetIPTVCfg to properly filter special characters and commands in the constructed command. No detailed vulnerability details are currently provided",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-5836"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006541"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-15726"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-5836",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "311579",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006541",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-15726",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15726"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006541"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5836"
          }
        ]
      },
      "id": "VAR-202506-0379",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15726"
          }
        ],
        "trust": 1.03844455
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15726"
          }
        ]
      },
      "last_update_date": "2025-07-17T23:49:51.519000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda AC9 command injection vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/709096"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15726"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-74",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "injection (CWE-74) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Command injection (CWE-77) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006541"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5836"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://candle-throne-f75.notion.site/tenda-ac9-formsetiptv-209df0aa11858061ae2bcbf83918d034"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.311579"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.591363"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.311579"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-5836"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15726"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006541"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5836"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15726"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006541"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5836"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-07-15T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-15726"
          },
          {
            "date": "2025-06-10T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006541"
          },
          {
            "date": "2025-06-07T14:15:22.500000",
            "db": "NVD",
            "id": "CVE-2025-5836"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-07-15T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-15726"
          },
          {
            "date": "2025-06-10T01:59:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006541"
          },
          {
            "date": "2025-06-09T19:07:49.417000",
            "db": "NVD",
            "id": "CVE-2025-5836"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Injection Vulnerability in Firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006541"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202506-0456

    Vulnerability from variot - Updated: 2025-07-17 23:46

    A vulnerability has been found in Tenda AC9 15.03.02.13 and classified as critical. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC9 The firmware contains a buffer error vulnerability, a stack-based buffer overflow vulnerability, and an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the parameter remoteIp in the file /goform/SetRemoteWebCfg failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202506-0456",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.2.13"
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  15.03.2.13"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "15.03.02.13"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15725"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006592"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5847"
          }
        ]
      },
      "cve": "CVE-2025-5847",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-5847",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006592",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-15725",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-5847",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006592",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-5847",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-006592",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-15725",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15725"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006592"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5847"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been found in Tenda AC9 15.03.02.13 and classified as critical. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC9 The firmware contains a buffer error vulnerability, a stack-based buffer overflow vulnerability, and an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the parameter remoteIp in the file /goform/SetRemoteWebCfg failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-5847"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006592"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-15725"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-5847",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "311593",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006592",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-15725",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15725"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006592"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5847"
          }
        ]
      },
      "id": "VAR-202506-0456",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15725"
          }
        ],
        "trust": 1.03844455
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15725"
          }
        ]
      },
      "last_update_date": "2025-07-17T23:46:47.066000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda AC9 /goform/SetRemoteWebCfg file buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/706156"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15725"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Buffer error (CWE-119) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006592"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5847"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://candle-throne-f75.notion.site/tenda-ac9-formsetsafewanwebman-20adf0aa118580a29e80cef9109c947a"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.311593"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.591362"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.311593"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-5847"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15725"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006592"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5847"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15725"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006592"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5847"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-07-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-15725"
          },
          {
            "date": "2025-06-10T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006592"
          },
          {
            "date": "2025-06-08T14:15:21.097000",
            "db": "NVD",
            "id": "CVE-2025-5847"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-07-15T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-15725"
          },
          {
            "date": "2025-06-10T07:06:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006592"
          },
          {
            "date": "2025-06-09T19:04:55.580000",
            "db": "NVD",
            "id": "CVE-2025-5847"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Buffer error vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006592"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202506-0500

    Vulnerability from variot - Updated: 2025-07-17 23:45

    A vulnerability, which was classified as critical, has been found in Tenda AC9 15.03.02.13. Affected by this issue is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC9 The firmware contains a buffer error vulnerability and a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the parameter lanMask in the file /goform/AdvSetLanip failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202506-0500",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.2.13"
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  15.03.2.13"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "15.03.02.13"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15724"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006593"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5839"
          }
        ]
      },
      "cve": "CVE-2025-5839",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-5839",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006593",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-15724",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-5839",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006593",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-5839",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-006593",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-15724",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15724"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006593"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5839"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability, which was classified as critical, has been found in Tenda AC9 15.03.02.13. Affected by this issue is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC9 The firmware contains a buffer error vulnerability and a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the parameter lanMask in the file /goform/AdvSetLanip failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-5839"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006593"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-15724"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-5839",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "311582",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006593",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-15724",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15724"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006593"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5839"
          }
        ]
      },
      "id": "VAR-202506-0500",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15724"
          }
        ],
        "trust": 1.03844455
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15724"
          }
        ]
      },
      "last_update_date": "2025-07-17T23:45:35.444000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda AC9 /goform/AdvSetLanip file buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/706146"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15724"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Buffer error (CWE-119) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Classic buffer overflow (CWE-120) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006593"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5839"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://candle-throne-f75.notion.site/tenda-ac9-fromadvsetlanip-20adf0aa11858027b7c3c2f4e44bb867"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.311582"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.591369"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.311582"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-5839"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15724"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006593"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5839"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-15724"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006593"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5839"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-07-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-15724"
          },
          {
            "date": "2025-06-10T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006593"
          },
          {
            "date": "2025-06-07T18:15:25.080000",
            "db": "NVD",
            "id": "CVE-2025-5839"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-07-15T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-15724"
          },
          {
            "date": "2025-06-10T07:06:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006593"
          },
          {
            "date": "2025-06-09T19:07:34.470000",
            "db": "NVD",
            "id": "CVE-2025-5839"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Buffer error vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006593"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202506-0476

    Vulnerability from variot - Updated: 2025-06-19 23:39

    A vulnerability, which was classified as problematic, was found in Tenda AC9 15.03.02.13. This affects an unknown part. The manipulation leads to cross-site request forgery. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC9 A cross-site request forgery vulnerability exists in firmware.Information is tampered with and service operation is interrupted (DoS) It may be in a state. No detailed vulnerability details are currently available

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202506-0476",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.2.13"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  15.03.2.13"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "15.03.02.13"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12741"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-007079"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5900"
          }
        ]
      },
      "cve": "CVE-2025-5900",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2025-5900",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "OTHER",
                "availabilityImpact": "None",
                "baseScore": 5.0,
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-007079",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-12741",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-5900",
                "impactScore": 1.4,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-5900",
                "impactScore": 4.2,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.1,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-007079",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-5900",
                "trust": 1.0,
                "value": "Low"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-5900",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-007079",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-12741",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12741"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-007079"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5900"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5900"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability, which was classified as problematic, was found in Tenda AC9 15.03.02.13. This affects an unknown part. The manipulation leads to cross-site request forgery. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC9 A cross-site request forgery vulnerability exists in firmware.Information is tampered with and service operation is interrupted (DoS) It may be in a state. No detailed vulnerability details are currently available",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-5900"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-007079"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-12741"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-5900",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "311673",
            "trust": 2.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-007079",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-12741",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12741"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-007079"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5900"
          }
        ]
      },
      "id": "VAR-202506-0476",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12741"
          }
        ],
        "trust": 1.03844455
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12741"
          }
        ]
      },
      "last_update_date": "2025-06-19T23:39:19.550000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-862",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-352",
            "trust": 1.0
          },
          {
            "problemtype": "Cross-site request forgery (CWE-352) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Cross-site request forgery (CWE-352) [NVD evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " Lack of authentication (CWE-862) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-007079"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5900"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://candle-throne-f75.notion.site/tenda-ac9-fromsystoolreboot-20adf0aa1185806a9d20ee5c355c08a6?pvs=73"
          },
          {
            "trust": 2.4,
            "url": "https://candle-throne-f75.notion.site/tenda-ac9-fromsystoolrestoreset-20adf0aa11858094a25ae21f9b4203da"
          },
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?id.311673"
          },
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?submit.592198"
          },
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?submit.592199"
          },
          {
            "trust": 2.4,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.6,
            "url": "https://vuldb.com/?ctiid.311673"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-5900"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12741"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-007079"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5900"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12741"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-007079"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5900"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-12741"
          },
          {
            "date": "2025-06-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-007079"
          },
          {
            "date": "2025-06-09T22:15:22.790000",
            "db": "NVD",
            "id": "CVE-2025-5900"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-12741"
          },
          {
            "date": "2025-06-17T01:44:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-007079"
          },
          {
            "date": "2025-06-16T14:42:41.297000",
            "db": "NVD",
            "id": "CVE-2025-5900"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Cross-site request forgery vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-007079"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202311-1968

    Vulnerability from variot - Updated: 2025-06-10 22:53

    Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202311-1968",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac19",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.05.19\\(6318\\)"
          },
          {
            "model": "ac6",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.05.19\\(6318\\)"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.05.19\\(6318\\)"
          },
          {
            "model": "ac18",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.05.19\\(6318\\)"
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-38823"
          }
        ]
      },
      "cve": "CVE-2023-38823",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2023-38823",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2023-38823",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2023-38823",
                "trust": 1.0,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-38823"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-38823"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-38823"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-38823"
          }
        ],
        "trust": 0.99
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2023-38823",
            "trust": 1.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-38823",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-38823"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-38823"
          }
        ]
      },
      "id": "VAR-202311-1968",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.41984727499999996
      },
      "last_update_date": "2025-06-10T22:53:02.208000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-38823"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://github.com/johnathanhuutri/cve_report/blob/master/cve-2023-38823/readme.md"
          },
          {
            "trust": 0.1,
            "url": "https://github.com/nhtri2003gmail/cve_report/blob/master/cve-2023-38823.md"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-38823"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-38823"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2023-38823"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-38823"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-20T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-38823"
          },
          {
            "date": "2023-11-20T20:15:07.357000",
            "db": "NVD",
            "id": "CVE-2023-38823"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-21T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-38823"
          },
          {
            "date": "2025-06-10T14:15:25.570000",
            "db": "NVD",
            "id": "CVE-2023-38823"
          }
        ]
      }
    }

    VAR-202505-0752

    Vulnerability from variot - Updated: 2025-05-29 23:41

    Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via the usbname parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request. Shenzhen Tenda Technology Co.,Ltd. of AC9 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202505-0752",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.06.42_multi"
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  15.03.06.42 multi"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9 15.03.06.42 multi",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09927"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005768"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44877"
          }
        ]
      },
      "cve": "CVE-2025-44877",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-09927",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-44877",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-005768",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-44877",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-005768",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09927",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09927"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005768"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44877"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via the usbname parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request. Shenzhen Tenda Technology Co.,Ltd. of AC9 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-44877"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005768"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09927"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-44877",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005768",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09927",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09927"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005768"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44877"
          }
        ]
      },
      "id": "VAR-202505-0752",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09927"
          }
        ],
        "trust": 1.319222275
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09927"
          }
        ]
      },
      "last_update_date": "2025-05-29T23:41:52.166000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005768"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44877"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/summermu/vulnforiot/tree/main/tenda_ac/ac9_formsetsambaconf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-44877"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09927"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005768"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44877"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09927"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005768"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44877"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-15T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09927"
          },
          {
            "date": "2025-05-28T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-005768"
          },
          {
            "date": "2025-05-02T15:15:49.323000",
            "db": "NVD",
            "id": "CVE-2025-44877"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09927"
          },
          {
            "date": "2025-05-28T05:47:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-005768"
          },
          {
            "date": "2025-05-27T14:21:50.710000",
            "db": "NVD",
            "id": "CVE-2025-44877"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Command injection vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005768"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202505-0643

    Vulnerability from variot - Updated: 2025-05-29 19:32

    Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via the deviceName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request. Shenzhen Tenda Technology Co.,Ltd. of AC9 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202505-0643",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.06.42_multi"
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  15.03.06.42 multi"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9 15.03.06.42 multi",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09928"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005752"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44872"
          }
        ]
      },
      "cve": "CVE-2025-44872",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-09928",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-44872",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-005752",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-44872",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-005752",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09928",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09928"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005752"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44872"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via the deviceName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request. Shenzhen Tenda Technology Co.,Ltd. of AC9 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-44872"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005752"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09928"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-44872",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005752",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09928",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09928"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005752"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44872"
          }
        ]
      },
      "id": "VAR-202505-0643",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09928"
          }
        ],
        "trust": 1.319222275
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09928"
          }
        ]
      },
      "last_update_date": "2025-05-29T19:32:18.336000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005752"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44872"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/summermu/vulnforiot/tree/main/tenda_ac/ac9_formsetusbunload"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-44872"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09928"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005752"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44872"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09928"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005752"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44872"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-15T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09928"
          },
          {
            "date": "2025-05-28T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-005752"
          },
          {
            "date": "2025-05-02T15:15:49.227000",
            "db": "NVD",
            "id": "CVE-2025-44872"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09928"
          },
          {
            "date": "2025-05-28T05:41:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-005752"
          },
          {
            "date": "2025-05-27T14:21:40.517000",
            "db": "NVD",
            "id": "CVE-2025-44872"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Command injection vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005752"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202501-1910

    Vulnerability from variot - Updated: 2025-05-17 23:17

    Tenda ac9 v1.0 firmware v15.03.05.19 is vulnerable to command injection in /goform/SetSambaCfg, which may lead to remote arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of AC9 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

    Tenda AC9 has a command injection vulnerability, which is caused by the discovery of a command injection vulnerability in /goform/SetSambaCfg. Attackers can exploit this vulnerability to remotely execute arbitrary code

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202501-1910",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.05.19"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  15.03.05.19"
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09941"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003162"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-22949"
          }
        ]
      },
      "cve": "CVE-2025-22949",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-09941",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-22949",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-003162",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-22949",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-003162",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09941",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09941"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003162"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-22949"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda ac9 v1.0 firmware v15.03.05.19 is vulnerable to command injection in /goform/SetSambaCfg, which may lead to remote arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of AC9 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nTenda AC9 has a command injection vulnerability, which is caused by the discovery of a command injection vulnerability in /goform/SetSambaCfg. Attackers can exploit this vulnerability to remotely execute arbitrary code",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-22949"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003162"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09941"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-22949",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003162",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09941",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09941"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003162"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-22949"
          }
        ]
      },
      "id": "VAR-202501-1910",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09941"
          }
        ],
        "trust": 1.03844455
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09941"
          }
        ]
      },
      "last_update_date": "2025-05-17T23:17:00.705000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003162"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-22949"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://noisy-caravel-a9a.notion.site/tenda_ac9v1-0_v15-03-05-19_formsetsambaconf_dosystemcmd_ci-16f898c94eac80d5801bdaf777ac2b27"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-22949"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09941"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003162"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-22949"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09941"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003162"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-22949"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09941"
          },
          {
            "date": "2025-04-10T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-003162"
          },
          {
            "date": "2025-01-10T16:15:31.137000",
            "db": "NVD",
            "id": "CVE-2025-22949"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09941"
          },
          {
            "date": "2025-04-10T07:30:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-003162"
          },
          {
            "date": "2025-04-09T18:36:01.027000",
            "db": "NVD",
            "id": "CVE-2025-22949"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Command injection vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003162"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202402-0826

    Vulnerability from variot - Updated: 2025-05-17 03:53

    Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allows a remote attacker to cause a denial of service or run arbitrary code via crafted overflow data. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

    Tenda AC9 has a buffer overflow vulnerability. The vulnerability stems from the failure of the setSchedWifi function to correctly verify the length of input data

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202402-0826",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.06.42_multi"
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  15.03.06.42 multi"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "3.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-14374"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-002610"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-24543"
          }
        ]
      },
      "cve": "CVE-2024-24543",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2024-14374",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2024-24543",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2024-24543",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-24543",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-24543",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2024-24543",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2024-14374",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-14374"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-002610"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-24543"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-24543"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allows a remote attacker to cause a denial of service or run arbitrary code via crafted overflow data. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\r\n\r\nTenda AC9 has a buffer overflow vulnerability. The vulnerability stems from the failure of the setSchedWifi function to correctly verify the length of input data",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-24543"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-002610"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-14374"
          },
          {
            "db": "VULMON",
            "id": "CVE-2024-24543"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-24543",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-002610",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-14374",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2024-24543",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-14374"
          },
          {
            "db": "VULMON",
            "id": "CVE-2024-24543"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-002610"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-24543"
          }
        ]
      },
      "id": "VAR-202402-0826",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-14374"
          }
        ],
        "trust": 1.03844455
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-14374"
          }
        ]
      },
      "last_update_date": "2025-05-17T03:53:01.546000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda AC9 buffer overflow vulnerability (CNVD-2024-14374)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/534936"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-14374"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-002610"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-24543"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.5,
            "url": "https://github.com/timeseg/iot_cve/blob/main/tenda/ac9v3/0130/setschedwifi.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-24543"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-14374"
          },
          {
            "db": "VULMON",
            "id": "CVE-2024-24543"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-002610"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-24543"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-14374"
          },
          {
            "db": "VULMON",
            "id": "CVE-2024-24543"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-002610"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-24543"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-03-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-14374"
          },
          {
            "date": "2024-02-05T00:00:00",
            "db": "VULMON",
            "id": "CVE-2024-24543"
          },
          {
            "date": "2024-02-16T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-002610"
          },
          {
            "date": "2024-02-05T21:15:12.073000",
            "db": "NVD",
            "id": "CVE-2024-24543"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-03-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-14374"
          },
          {
            "date": "2024-02-06T00:00:00",
            "db": "VULMON",
            "id": "CVE-2024-24543"
          },
          {
            "date": "2024-02-16T01:03:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-002610"
          },
          {
            "date": "2025-05-15T20:15:47.027000",
            "db": "NVD",
            "id": "CVE-2024-24543"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-002610"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202505-0256

    Vulnerability from variot - Updated: 2025-05-15 23:16

    Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function. Shenzhen Tenda Technology Co.,Ltd. of AC9 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. No detailed vulnerability details are currently provided

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202505-0256",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.05.14"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  15.03.05.14"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09670"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004486"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45042"
          }
        ]
      },
      "cve": "CVE-2025-45042",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-09670",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-45042",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2025-45042",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-45042",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-45042",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2025-45042",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09670",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09670"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004486"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45042"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45042"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function. Shenzhen Tenda Technology Co.,Ltd. of AC9 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. No detailed vulnerability details are currently provided",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-45042"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004486"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09670"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-45042",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004486",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09670",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09670"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004486"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45042"
          }
        ]
      },
      "id": "VAR-202505-0256",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09670"
          }
        ],
        "trust": 1.03844455
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09670"
          }
        ]
      },
      "last_update_date": "2025-05-15T23:16:06.317000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-78",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": "OS Command injection (CWE-78) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004486"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45042"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/ghostsuzhijian/iot-/blob/main/ac9_telnetd/rx3_telnetd.md"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-45042"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09670"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004486"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45042"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09670"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004486"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45042"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09670"
          },
          {
            "date": "2025-05-08T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-004486"
          },
          {
            "date": "2025-05-05T16:15:51.410000",
            "db": "NVD",
            "id": "CVE-2025-45042"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09670"
          },
          {
            "date": "2025-05-08T07:25:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-004486"
          },
          {
            "date": "2025-05-07T16:39:20.990000",
            "db": "NVD",
            "id": "CVE-2025-45042"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Command injection vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004486"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202501-2101

    Vulnerability from variot - Updated: 2025-05-15 23:15

    Tenda ac9 v1.0 firmware v15.03.05.19 contains a stack overflow vulnerability in /goform/SetOnlineDevName, which may lead to remote arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of AC9 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Attackers can exploit this vulnerability to remotely execute arbitrary code

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202501-2101",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.05.19"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  15.03.05.19"
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09691"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003400"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-22946"
          }
        ]
      },
      "cve": "CVE-2025-22946",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-09691",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-22946",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-003400",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-22946",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-003400",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09691",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09691"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003400"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-22946"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda ac9 v1.0 firmware v15.03.05.19 contains a stack overflow vulnerability in /goform/SetOnlineDevName, which may lead to remote arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of AC9 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Attackers can exploit this vulnerability to remotely execute arbitrary code",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-22946"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003400"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09691"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-22946",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003400",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09691",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09691"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003400"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-22946"
          }
        ]
      },
      "id": "VAR-202501-2101",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09691"
          }
        ],
        "trust": 1.03844455
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09691"
          }
        ]
      },
      "last_update_date": "2025-05-15T23:15:14.820000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Classic buffer overflow (CWE-120) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003400"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-22946"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://noisy-caravel-a9a.notion.site/tenda_ac9v1-0_v15-03-05-19_formsetdevicename_sprintf_bof-16f898c94eac8057afcbceb63fda7d24"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-22946"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09691"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003400"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-22946"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09691"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003400"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-22946"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09691"
          },
          {
            "date": "2025-04-14T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-003400"
          },
          {
            "date": "2025-01-10T15:15:16.710000",
            "db": "NVD",
            "id": "CVE-2025-22946"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09691"
          },
          {
            "date": "2025-04-14T08:35:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-003400"
          },
          {
            "date": "2025-04-09T18:35:44.810000",
            "db": "NVD",
            "id": "CVE-2025-22946"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Classic buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003400"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202504-3439

    Vulnerability from variot - Updated: 2025-05-15 23:09

    In Tenda ac9 v1.0 with firmware V15.03.05.14_multi, the rebootTime parameter of /goform/SetSysAutoRebbotCfg has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of AC9 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

    Tenda AC9 has a buffer overflow vulnerability. The vulnerability is caused by the rebootTime parameter of /goform/SetSysAutoRebbotCfg failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202504-3439",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.05.14_multi"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  15.03.05.14 multi"
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "15.03.05.14"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09671"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004234"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45428"
          }
        ]
      },
      "cve": "CVE-2025-45428",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-09671",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-45428",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-004234",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-45428",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-004234",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09671",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09671"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004234"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45428"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "In Tenda ac9 v1.0 with firmware V15.03.05.14_multi, the rebootTime parameter of /goform/SetSysAutoRebbotCfg has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of AC9 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nTenda AC9 has a buffer overflow vulnerability. The vulnerability is caused by the rebootTime parameter of /goform/SetSysAutoRebbotCfg failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-45428"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004234"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09671"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-45428",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004234",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09671",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09671"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004234"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45428"
          }
        ]
      },
      "id": "VAR-202504-3439",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09671"
          }
        ],
        "trust": 1.03844455
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09671"
          }
        ]
      },
      "last_update_date": "2025-05-15T23:09:30.331000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004234"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45428"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/shuqi233/loophole/blob/main/tenda%20ac9/setsysautorebbotcfg-reboottime.md"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-45428"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09671"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004234"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45428"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09671"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004234"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45428"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09671"
          },
          {
            "date": "2025-05-01T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-004234"
          },
          {
            "date": "2025-04-23T15:16:00.970000",
            "db": "NVD",
            "id": "CVE-2025-45428"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09671"
          },
          {
            "date": "2025-05-01T03:18:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-004234"
          },
          {
            "date": "2025-04-30T16:12:11.190000",
            "db": "NVD",
            "id": "CVE-2025-45428"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004234"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202504-3441

    Vulnerability from variot - Updated: 2025-05-15 19:32

    In the Tenda ac9 v1.0 router with firmware V15.03.05.14_multi, there is a stack overflow vulnerability in /goform/WifiWpsStart, which may lead to remote arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of AC9 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

    Tenda AC9 has a buffer overflow vulnerability, which is caused by /goform/WifiWpsStart failing to properly verify the length of input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202504-3441",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.05.14_multi"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  15.03.05.14 multi"
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "15.03.05.14"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09672"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004260"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45429"
          }
        ]
      },
      "cve": "CVE-2025-45429",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-09672",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-45429",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-004260",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-45429",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-004260",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09672",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09672"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004260"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45429"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "In the Tenda ac9 v1.0 router with firmware V15.03.05.14_multi, there is a stack overflow vulnerability in /goform/WifiWpsStart, which may lead to remote arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of AC9 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nTenda AC9 has a buffer overflow vulnerability, which is caused by /goform/WifiWpsStart failing to properly verify the length of input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-45429"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004260"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09672"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-45429",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004260",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09672",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09672"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004260"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45429"
          }
        ]
      },
      "id": "VAR-202504-3441",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09672"
          }
        ],
        "trust": 1.03844455
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09672"
          }
        ]
      },
      "last_update_date": "2025-05-15T19:32:28.860000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004260"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45429"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/shuqi233/loophole/blob/main/tenda%20ac9/wifiwpsstart-index.md"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-45429"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09672"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004260"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45429"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09672"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004260"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45429"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09672"
          },
          {
            "date": "2025-05-01T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-004260"
          },
          {
            "date": "2025-04-23T16:15:48.473000",
            "db": "NVD",
            "id": "CVE-2025-45429"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09672"
          },
          {
            "date": "2025-05-01T05:08:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-004260"
          },
          {
            "date": "2025-04-30T15:48:51.963000",
            "db": "NVD",
            "id": "CVE-2025-45429"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004260"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202504-3416

    Vulnerability from variot - Updated: 2025-05-10 23:19

    In Tenda AC9 v1.0 with firmware V15.03.05.14_multi, the security parameter of /goform/WifiBasicSet has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of AC9 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

    Tenda AC9 V15.03.05.14_multi has a buffer overflow vulnerability. The vulnerability is caused by the /goform/WifiBasicSet security parameter failing to properly verify the length of the input data

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202504-3416",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.05.14_multi"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  15.03.05.14 multi"
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9 15.03.05.14 multi",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09281"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004230"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45427"
          }
        ]
      },
      "cve": "CVE-2025-45427",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-09281",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-45427",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-004230",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-45427",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-004230",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09281",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09281"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004230"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45427"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "In Tenda AC9 v1.0 with firmware V15.03.05.14_multi, the security parameter of /goform/WifiBasicSet has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of AC9 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nTenda AC9 V15.03.05.14_multi has a buffer overflow vulnerability. The vulnerability is caused by the /goform/WifiBasicSet security parameter failing to properly verify the length of the input data",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-45427"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004230"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09281"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-45427",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004230",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09281",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09281"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004230"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45427"
          }
        ]
      },
      "id": "VAR-202504-3416",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09281"
          }
        ],
        "trust": 1.03844455
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09281"
          }
        ]
      },
      "last_update_date": "2025-05-10T23:19:24.597000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004230"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45427"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/shuqi233/loophole/blob/main/tenda%20ac9/wifibasicset-security.md"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-45427"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09281"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004230"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45427"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09281"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004230"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-45427"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09281"
          },
          {
            "date": "2025-05-01T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-004230"
          },
          {
            "date": "2025-04-23T15:16:00.880000",
            "db": "NVD",
            "id": "CVE-2025-45427"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-09T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09281"
          },
          {
            "date": "2025-05-01T03:13:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-004230"
          },
          {
            "date": "2025-04-30T13:51:20.023000",
            "db": "NVD",
            "id": "CVE-2025-45427"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-004230"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-0574

    Vulnerability from variot - Updated: 2025-05-09 23:32

    In Tenda AC9 v1.0 V15.03.05.14_multi, the wanSpeed parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

    Tenda AC9 has a buffer overflow vulnerability. The vulnerability is caused by the wanSpeed parameter of the formAdvSetMacMtuWan function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-0574",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.05.14"
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  15.03.05.14"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          },
          {
            "model": "ac9 15.03.05.14 multi",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09159"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002417"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29387"
          }
        ]
      },
      "cve": "CVE-2025-29387",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "HIGH",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.1,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2025-09159",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:H/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.2,
                "id": "CVE-2025-29387",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "High",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.1,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2025-29387",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-29387",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-29387",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2025-29387",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09159",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09159"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002417"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29387"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29387"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "In Tenda AC9 v1.0 V15.03.05.14_multi, the wanSpeed parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nTenda AC9 has a buffer overflow vulnerability. The vulnerability is caused by the wanSpeed parameter of the formAdvSetMacMtuWan function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-29387"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002417"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09159"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-29387",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002417",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09159",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09159"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002417"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29387"
          }
        ]
      },
      "id": "VAR-202503-0574",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09159"
          }
        ],
        "trust": 1.03844455
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09159"
          }
        ]
      },
      "last_update_date": "2025-05-09T23:32:44.074000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002417"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29387"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/shuqi233/loophole/blob/main/tenda%20ac9/advsetmacmtuwan2.md"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-29387"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09159"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002417"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29387"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09159"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002417"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29387"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-28T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09159"
          },
          {
            "date": "2025-03-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-002417"
          },
          {
            "date": "2025-03-14T17:15:52.720000",
            "db": "NVD",
            "id": "CVE-2025-29387"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-07T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09159"
          },
          {
            "date": "2025-03-18T03:16:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-002417"
          },
          {
            "date": "2025-03-17T19:51:04.180000",
            "db": "NVD",
            "id": "CVE-2025-29387"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002417"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-0623

    Vulnerability from variot - Updated: 2025-05-09 23:14

    In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

    Tenda AC9 has a buffer overflow vulnerability. The vulnerability is caused by the wanMTU parameter of the formAdvSetMacMtuWan function failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-0623",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.05.14"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  15.03.05.14"
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          },
          {
            "model": "ac9 15.03.05.14 multi",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09158"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002442"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29384"
          }
        ]
      },
      "cve": "CVE-2025-29384",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-09158",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-29384",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2025-29384",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-29384",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-29384",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2025-29384",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09158",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09158"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002442"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29384"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29384"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nTenda AC9 has a buffer overflow vulnerability. The vulnerability is caused by the wanMTU parameter of the formAdvSetMacMtuWan function failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-29384"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002442"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09158"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-29384",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002442",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09158",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09158"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002442"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29384"
          }
        ]
      },
      "id": "VAR-202503-0623",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09158"
          }
        ],
        "trust": 1.03844455
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09158"
          }
        ]
      },
      "last_update_date": "2025-05-09T23:14:55.421000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002442"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29384"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/shuqi233/loophole/blob/main/tenda%20ac9/advsetmacmtuwan1.md"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-29384"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09158"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002442"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29384"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09158"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002442"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29384"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-28T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09158"
          },
          {
            "date": "2025-03-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-002442"
          },
          {
            "date": "2025-03-14T17:15:52.230000",
            "db": "NVD",
            "id": "CVE-2025-29384"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-07T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09158"
          },
          {
            "date": "2025-03-19T01:31:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-002442"
          },
          {
            "date": "2025-03-19T19:15:49.133000",
            "db": "NVD",
            "id": "CVE-2025-29384"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002442"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-1739

    Vulnerability from variot - Updated: 2025-05-09 23:14

    Tenda AC9 v15.03.05.19(6318) was discovered to contain a buffer overflow via the formWifiWpsOOB function. Tenda of AC9 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC9 is a wireless router from China's Tenda company. No detailed vulnerability details are currently available

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-1739",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tendacn",
            "version": "15.03.05.19\\(6318\\)"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  15.03.05.19(6318)"
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "15.03.05.19(6318)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09160"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003045"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29032"
          }
        ]
      },
      "cve": "CVE-2025-29032",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "HIGH",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.1,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2025-09160",
                "impactScore": 8.5,
                "integrityImpact": "COMPLETE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:H/Au:S/C:P/I:C/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "LOW",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 1.2,
                "id": "CVE-2025-29032",
                "impactScore": 4.7,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:L/I:H/A:L",
                "version": "3.1"
              },
              {
                "attackComplexity": "High",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "Low",
                "baseScore": 5.9,
                "baseSeverity": "Medium",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-003045",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:R/S:U/C:L/I:H/A:L",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-29032",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-003045",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09160",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09160"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003045"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29032"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda AC9 v15.03.05.19(6318) was discovered to contain a buffer overflow via the formWifiWpsOOB function. Tenda of AC9 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC9 is a wireless router from China\u0027s Tenda company. No detailed vulnerability details are currently available",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-29032"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003045"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09160"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-29032",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003045",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09160",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09160"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003045"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29032"
          }
        ]
      },
      "id": "VAR-202503-1739",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09160"
          }
        ],
        "trust": 1.03844455
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09160"
          }
        ]
      },
      "last_update_date": "2025-05-09T23:14:55.343000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Classic buffer overflow (CWE-120) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003045"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29032"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/whereisdoujo/cve/issues/6"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-29032"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09160"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003045"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29032"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09160"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003045"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29032"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-28T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09160"
          },
          {
            "date": "2025-04-08T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-003045"
          },
          {
            "date": "2025-03-14T14:15:18.623000",
            "db": "NVD",
            "id": "CVE-2025-29032"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-07T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09160"
          },
          {
            "date": "2025-04-08T08:04:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-003045"
          },
          {
            "date": "2025-04-03T15:46:23.280000",
            "db": "NVD",
            "id": "CVE-2025-29032"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda\u00a0 of \u00a0AC9\u00a0 Classic buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003045"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-0549

    Vulnerability from variot - Updated: 2025-05-01 23:31

    In Tenda AC9 v1.0 V15.03.05.14_multi, the cloneType parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

    Tenda AC9 has a buffer overflow vulnerability. The vulnerability is caused by the cloneType parameter of the formAdvSetMacMtuWan function failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-0549",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.05.14"
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  15.03.05.14"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          },
          {
            "model": "ac9 15.03.05.14 multi",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08912"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002428"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29385"
          }
        ]
      },
      "cve": "CVE-2025-29385",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-08912",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-29385",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2025-29385",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-29385",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-29385",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2025-29385",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-08912",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08912"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002428"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29385"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29385"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "In Tenda AC9 v1.0 V15.03.05.14_multi, the cloneType parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nTenda AC9 has a buffer overflow vulnerability. The vulnerability is caused by the cloneType parameter of the formAdvSetMacMtuWan function failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-29385"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002428"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-08912"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-29385",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002428",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-08912",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08912"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002428"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29385"
          }
        ]
      },
      "id": "VAR-202503-0549",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08912"
          }
        ],
        "trust": 1.03844455
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08912"
          }
        ]
      },
      "last_update_date": "2025-05-01T23:31:17.713000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002428"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29385"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/shuqi233/loophole/blob/main/tenda%20ac9/advsetmacmtuwan3.md"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-29385"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08912"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002428"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29385"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08912"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002428"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29385"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-28T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-08912"
          },
          {
            "date": "2025-03-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-002428"
          },
          {
            "date": "2025-03-14T17:15:52.393000",
            "db": "NVD",
            "id": "CVE-2025-29385"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-30T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-08912"
          },
          {
            "date": "2025-03-18T07:46:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-002428"
          },
          {
            "date": "2025-03-19T19:15:49.280000",
            "db": "NVD",
            "id": "CVE-2025-29385"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002428"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-0655

    Vulnerability from variot - Updated: 2025-04-30 23:07

    In Tenda AC9 v1.0 V15.03.05.14_multi, the mac parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

    Tenda AC9 formAdvSetMacMtuWan has a buffer overflow vulnerability. The vulnerability is caused by the mac parameter of the formAdvSetMacMtuWan function failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-0655",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.05.14"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac9  firmware  15.03.05.14"
          },
          {
            "model": "ac9",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          },
          {
            "model": "ac9 15.03.05.14 multi",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08795"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002441"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29386"
          }
        ]
      },
      "cve": "CVE-2025-29386",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-08795",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-29386",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2025-29386",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-29386",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-29386",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2025-29386",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-08795",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08795"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002441"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29386"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29386"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "In Tenda AC9 v1.0 V15.03.05.14_multi, the mac parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nTenda AC9 formAdvSetMacMtuWan has a buffer overflow vulnerability. The vulnerability is caused by the mac parameter of the formAdvSetMacMtuWan function failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-29386"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002441"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-08795"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-29386",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002441",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-08795",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08795"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002441"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29386"
          }
        ]
      },
      "id": "VAR-202503-0655",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08795"
          }
        ],
        "trust": 1.03844455
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08795"
          }
        ]
      },
      "last_update_date": "2025-04-30T23:07:00.663000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002441"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29386"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/shuqi233/loophole/blob/main/tenda%20ac9/advsetmacmtuwan4.md"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-29386"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08795"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002441"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29386"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08795"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002441"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29386"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-25T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-08795"
          },
          {
            "date": "2025-03-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-002441"
          },
          {
            "date": "2025-03-14T17:15:52.557000",
            "db": "NVD",
            "id": "CVE-2025-29386"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-29T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-08795"
          },
          {
            "date": "2025-03-19T01:31:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-002441"
          },
          {
            "date": "2025-03-19T19:15:49.423000",
            "db": "NVD",
            "id": "CVE-2025-29386"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002441"
          }
        ],
        "trust": 0.8
      }
    }

    CVE-2025-14286 (GCVE-0-2025-14286)

    Vulnerability from nvd – Published: 2025-12-09 01:32 – Updated: 2026-02-24 05:45
    VLAI
    Title
    Tenda AC9 Configuration File DownloadCfg.jpg information disclosure
    Summary
    A vulnerability was determined in Tenda AC9 15.03.05.14_multi. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/DownloadCfg.jpg of the component Configuration File Handler. This manipulation causes information disclosure. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.334874 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.334874 signaturepermissions-required
    https://vuldb.com/?submit.702723 third-party-advisory
    https://github.com/Madgeaaaaa/MY_VULN_2/blob/main… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.05.14_multi
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    jiahui2888 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14286",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-09T14:35:32.257434Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-09T16:03:13.496Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN11.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Configuration File Handler"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.14_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "jiahui2888 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda AC9 15.03.05.14_multi. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/DownloadCfg.jpg of the component Configuration File Handler. This manipulation causes information disclosure. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N/E:POC/RL:W/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "Information Disclosure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "Improper Access Controls",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-24T05:45:24.166Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-334874 | Tenda AC9 Configuration File DownloadCfg.jpg information disclosure",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.334874"
            },
            {
              "name": "VDB-334874 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.334874"
            },
            {
              "name": "Submit #702723 | Tenda AC9 V1.0  V15.03.05.14_multi Information Disclosure",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.702723"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN11.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-12-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-12-08T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-12-12T08:32:52.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 Configuration File DownloadCfg.jpg information disclosure"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-14286",
        "datePublished": "2025-12-09T01:32:07.198Z",
        "dateReserved": "2025-12-08T18:49:39.958Z",
        "dateUpdated": "2026-02-24T05:45:24.166Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14286 (GCVE-0-2025-14286)

    Vulnerability from cvelistv5 – Published: 2025-12-09 01:32 – Updated: 2026-02-24 05:45
    VLAI
    Title
    Tenda AC9 Configuration File DownloadCfg.jpg information disclosure
    Summary
    A vulnerability was determined in Tenda AC9 15.03.05.14_multi. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/DownloadCfg.jpg of the component Configuration File Handler. This manipulation causes information disclosure. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.334874 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.334874 signaturepermissions-required
    https://vuldb.com/?submit.702723 third-party-advisory
    https://github.com/Madgeaaaaa/MY_VULN_2/blob/main… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.05.14_multi
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    jiahui2888 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14286",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-09T14:35:32.257434Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-09T16:03:13.496Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN11.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Configuration File Handler"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.14_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "jiahui2888 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda AC9 15.03.05.14_multi. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/DownloadCfg.jpg of the component Configuration File Handler. This manipulation causes information disclosure. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N/E:POC/RL:W/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "Information Disclosure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "Improper Access Controls",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-24T05:45:24.166Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-334874 | Tenda AC9 Configuration File DownloadCfg.jpg information disclosure",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.334874"
            },
            {
              "name": "VDB-334874 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.334874"
            },
            {
              "name": "Submit #702723 | Tenda AC9 V1.0  V15.03.05.14_multi Information Disclosure",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.702723"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN11.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-12-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-12-08T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-12-12T08:32:52.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 Configuration File DownloadCfg.jpg information disclosure"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-14286",
        "datePublished": "2025-12-09T01:32:07.198Z",
        "dateReserved": "2025-12-08T18:49:39.958Z",
        "dateUpdated": "2026-02-24T05:45:24.166Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }