Search criteria

48 vulnerabilities found for ac21_firmware by tenda

CVE-2025-65226 (GCVE-0-2025-65226)

Vulnerability from nvd – Published: 2025-11-20 00:00 – Updated: 2025-11-20 15:31
VLAI?
Summary
Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the deviceId parameter in /goform/saveParentControlInfo.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-65226",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-20T15:31:02.534249Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-120",
                "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-20T15:31:42.041Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the deviceId parameter in /goform/saveParentControlInfo."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T14:48:56.814Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN5.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-65226",
    "datePublished": "2025-11-20T00:00:00.000Z",
    "dateReserved": "2025-11-18T00:00:00.000Z",
    "dateUpdated": "2025-11-20T15:31:42.041Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-65223 (GCVE-0-2025-65223)

Vulnerability from nvd – Published: 2025-11-20 00:00 – Updated: 2025-11-20 15:30
VLAI?
Summary
Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the urls parameter of /goform/saveParentControlInfo.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-65223",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-20T15:29:47.324586Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-20T15:30:24.490Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the urls parameter of /goform/saveParentControlInfo."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T14:55:18.918Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN4.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-65223",
    "datePublished": "2025-11-20T00:00:00.000Z",
    "dateReserved": "2025-11-18T00:00:00.000Z",
    "dateUpdated": "2025-11-20T15:30:24.490Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-65222 (GCVE-0-2025-65222)

Vulnerability from nvd – Published: 2025-11-20 00:00 – Updated: 2025-11-20 15:28
VLAI?
Summary
Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the rebootTime parameter of /goform/SetSysAutoRebbotCfg.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-65222",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-20T15:27:57.732201Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-20T15:28:14.424Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the rebootTime parameter of /goform/SetSysAutoRebbotCfg."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T14:57:26.202Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN3.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-65222",
    "datePublished": "2025-11-20T00:00:00.000Z",
    "dateReserved": "2025-11-18T00:00:00.000Z",
    "dateUpdated": "2025-11-20T15:28:14.424Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-65221 (GCVE-0-2025-65221)

Vulnerability from nvd – Published: 2025-11-20 00:00 – Updated: 2025-11-20 15:29
VLAI?
Summary
Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the list parameter of /goform/setPptpUserList.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-65221",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-20T15:28:37.960092Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-20T15:29:04.604Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the list parameter of /goform/setPptpUserList."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T15:00:07.614Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN2.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-65221",
    "datePublished": "2025-11-20T00:00:00.000Z",
    "dateReserved": "2025-11-18T00:00:00.000Z",
    "dateUpdated": "2025-11-20T15:29:04.604Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-65220 (GCVE-0-2025-65220)

Vulnerability from nvd – Published: 2025-11-20 00:00 – Updated: 2025-11-20 15:27
VLAI?
Summary
Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow in: /goform/SetVirtualServerCfg via the list parameter.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-65220",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-20T15:26:49.120930Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-20T15:27:20.035Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow in: /goform/SetVirtualServerCfg via the list parameter."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T15:02:57.111Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-65220",
    "datePublished": "2025-11-20T00:00:00.000Z",
    "dateReserved": "2025-11-18T00:00:00.000Z",
    "dateUpdated": "2025-11-20T15:27:20.035Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-13446 (GCVE-0-2025-13446)

Vulnerability from nvd – Published: 2025-11-20 02:32 – Updated: 2025-11-20 14:52
VLAI?
Title
Tenda AC21 SetSysTimeCfg stack-based overflow
Summary
A vulnerability has been found in Tenda AC21 16.03.08.16. This vulnerability affects unknown code of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone/time leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
jiahui288 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-13446",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-20T14:16:02.059248Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-20T14:52:07.354Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN8.md"
          },
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN9.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "jiahui288 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda AC21 16.03.08.16. This vulnerability affects unknown code of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone/time leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T02:32:07.969Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-333018 | Tenda AC21 SetSysTimeCfg stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.333018"
        },
        {
          "name": "VDB-333018 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.333018"
        },
        {
          "name": "Submit #694425 | Tenda AC21 V16.03.08.16  Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.694425"
        },
        {
          "name": "Submit #694430 | Tenda AC21 V16.03.08.16  Buffer Overflow (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.694430"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN8.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN9.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-11-19T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-11-19T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-11-19T20:19:45.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 SetSysTimeCfg stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-13446",
    "datePublished": "2025-11-20T02:32:07.969Z",
    "dateReserved": "2025-11-19T19:14:38.513Z",
    "dateUpdated": "2025-11-20T14:52:07.354Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-13445 (GCVE-0-2025-13445)

Vulnerability from nvd – Published: 2025-11-20 02:02 – Updated: 2025-11-20 14:52
VLAI?
Title
Tenda AC21 SetIpMacBind stack-based overflow
Summary
A flaw has been found in Tenda AC21 16.03.08.16. This affects an unknown part of the file /goform/SetIpMacBind. Executing manipulation of the argument list can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been published and may be used.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
jiahui288 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-13445",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-20T14:17:02.610671Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-20T14:52:14.900Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN7.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "jiahui288 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw has been found in Tenda AC21 16.03.08.16. This affects an unknown part of the file /goform/SetIpMacBind. Executing manipulation of the argument list can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been published and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T02:02:09.585Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-333017 | Tenda AC21 SetIpMacBind stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.333017"
        },
        {
          "name": "VDB-333017 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.333017"
        },
        {
          "name": "Submit #694066 | Tenda AC21 V16.03.08.16  Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.694066"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN7.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-11-19T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-11-19T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-11-19T20:19:41.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 SetIpMacBind stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-13445",
    "datePublished": "2025-11-20T02:02:09.585Z",
    "dateReserved": "2025-11-19T19:14:36.023Z",
    "dateUpdated": "2025-11-20T14:52:14.900Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-12611 (GCVE-0-2025-12611)

Vulnerability from nvd – Published: 2025-11-03 02:02 – Updated: 2025-11-03 14:26
VLAI?
Title
Tenda AC21 SetPptpServerCfg formSetPPTPServer buffer overflow
Summary
A vulnerability was identified in Tenda AC21 16.03.08.16. This vulnerability affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIp leads to buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
CWE
Assigner
References
https://vuldb.com/?id.330906 vdb-entrytechnical-description
https://vuldb.com/?ctiid.330906 signaturepermissions-required
https://vuldb.com/?submit.678491 third-party-advisory
https://github.com/LX-LX88/cve/issues/10 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
LX-LX (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12611",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-03T14:16:45.645981Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-03T14:26:36.736Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LX-LX (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was identified in Tenda AC21 16.03.08.16. This vulnerability affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIp leads to buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC21 16.03.08.16 wurde eine Schwachstelle gefunden. Es geht dabei um die Funktion formSetPPTPServer der Datei /goform/SetPptpServerCfg. Mit der Manipulation des Arguments startIp mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit wurde der \u00d6ffentlichkeit bekannt gemacht und k\u00f6nnte verwendet werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-03T02:02:09.734Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-330906 | Tenda AC21 SetPptpServerCfg formSetPPTPServer buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.330906"
        },
        {
          "name": "VDB-330906 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.330906"
        },
        {
          "name": "Submit #678491 | Tenda AC21 V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.678491"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/LX-LX88/cve/issues/10"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-11-02T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-11-02T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-11-02T07:33:49.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 SetPptpServerCfg formSetPPTPServer buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-12611",
    "datePublished": "2025-11-03T02:02:09.734Z",
    "dateReserved": "2025-11-02T06:28:46.133Z",
    "dateUpdated": "2025-11-03T14:26:36.736Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-11091 (GCVE-0-2025-11091)

Vulnerability from nvd – Published: 2025-09-28 01:32 – Updated: 2025-09-29 14:48
VLAI?
Title
Tenda AC21 SetStaticRouteCfg sscanf buffer overflow
Summary
A security flaw has been discovered in Tenda AC21 up to 16.03.08.16. Affected by this vulnerability is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. The attack can be launched remotely. The exploit has been released to the public and may be exploited.
CWE
Assigner
References
https://vuldb.com/?id.326173 vdb-entrytechnical-description
https://vuldb.com/?ctiid.326173 signaturepermissions-required
https://vuldb.com/?submit.661806 third-party-advisory
https://github.com/maximdevere/CVE2/issues/2 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.0
Affected: 16.03.08.1
Affected: 16.03.08.2
Affected: 16.03.08.3
Affected: 16.03.08.4
Affected: 16.03.08.5
Affected: 16.03.08.6
Affected: 16.03.08.7
Affected: 16.03.08.8
Affected: 16.03.08.9
Affected: 16.03.08.10
Affected: 16.03.08.11
Affected: 16.03.08.12
Affected: 16.03.08.13
Affected: 16.03.08.14
Affected: 16.03.08.15
Affected: 16.03.08.16
Create a notification for this product.
Credits
MaximDeVere (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11091",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-29T14:48:52.752774Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-29T14:48:57.508Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/maximdevere/CVE2/issues/2"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.0"
            },
            {
              "status": "affected",
              "version": "16.03.08.1"
            },
            {
              "status": "affected",
              "version": "16.03.08.2"
            },
            {
              "status": "affected",
              "version": "16.03.08.3"
            },
            {
              "status": "affected",
              "version": "16.03.08.4"
            },
            {
              "status": "affected",
              "version": "16.03.08.5"
            },
            {
              "status": "affected",
              "version": "16.03.08.6"
            },
            {
              "status": "affected",
              "version": "16.03.08.7"
            },
            {
              "status": "affected",
              "version": "16.03.08.8"
            },
            {
              "status": "affected",
              "version": "16.03.08.9"
            },
            {
              "status": "affected",
              "version": "16.03.08.10"
            },
            {
              "status": "affected",
              "version": "16.03.08.11"
            },
            {
              "status": "affected",
              "version": "16.03.08.12"
            },
            {
              "status": "affected",
              "version": "16.03.08.13"
            },
            {
              "status": "affected",
              "version": "16.03.08.14"
            },
            {
              "status": "affected",
              "version": "16.03.08.15"
            },
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "MaximDeVere (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security flaw has been discovered in Tenda AC21 up to 16.03.08.16. Affected by this vulnerability is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. The attack can be launched remotely. The exploit has been released to the public and may be exploited."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda AC21 up to 16.03.08.16 entdeckt. Dabei geht es um die Funktion sscanf der Datei /goform/SetStaticRouteCfg. Dank Manipulation des Arguments list mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff l\u00e4sst sich \u00fcber das Netzwerk starten. Der Exploit ist \u00f6ffentlich verf\u00fcgbar und k\u00f6nnte genutzt werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-28T01:32:10.696Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-326173 | Tenda AC21 SetStaticRouteCfg sscanf buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.326173"
        },
        {
          "name": "VDB-326173 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.326173"
        },
        {
          "name": "Submit #661806 | Shenzhen Tenda Technology Co.,Ltd. AC21 \u003c= V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.661806"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/maximdevere/CVE2/issues/2"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-09-27T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-09-27T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-09-27T07:31:48.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 SetStaticRouteCfg sscanf buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-11091",
    "datePublished": "2025-09-28T01:32:10.696Z",
    "dateReserved": "2025-09-27T05:26:44.839Z",
    "dateUpdated": "2025-09-29T14:48:57.508Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-10838 (GCVE-0-2025-10838)

Vulnerability from nvd – Published: 2025-09-23 04:32 – Updated: 2025-09-23 19:12
VLAI?
Title
Tenda AC21 WifiExtraSet sub_45BB10 buffer overflow
Summary
A vulnerability was identified in Tenda AC21 16.03.08.16. The affected element is the function sub_45BB10 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to buffer overflow. It is possible to initiate the attack remotely. The exploit is publicly available and might be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
QMSSDXN (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-10838",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-23T19:12:21.343557Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-23T19:12:30.355Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "QMSSDXN (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was identified in Tenda AC21 16.03.08.16. The affected element is the function sub_45BB10 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to buffer overflow. It is possible to initiate the attack remotely. The exploit is publicly available and might be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC21 16.03.08.16 gefunden. Es geht dabei um die Funktion sub_45BB10 der Datei /goform/WifiExtraSet. Durch Manipulieren des Arguments wpapsk_crypto mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-23T04:32:07.071Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-325200 | Tenda AC21 WifiExtraSet sub_45BB10 buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.325200"
        },
        {
          "name": "VDB-325200 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.325200"
        },
        {
          "name": "Submit #657126 | Tenda AC21 \u2264V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.657126"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/lin-3-start/lin-cve/blob/main/Tenda%20AC21/Tenda%20AC21%20Buffer%20overflow.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/lin-3-start/lin-cve/blob/main/Tenda%20AC21/Tenda%20AC21%20Buffer%20overflow.md#poc"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-09-22T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-09-22T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-09-22T07:15:16.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 WifiExtraSet sub_45BB10 buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-10838",
    "datePublished": "2025-09-23T04:32:07.071Z",
    "dateReserved": "2025-09-22T05:10:13.621Z",
    "dateUpdated": "2025-09-23T19:12:30.355Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-9605 (GCVE-0-2025-9605)

Vulnerability from nvd – Published: 2025-08-29 02:02 – Updated: 2025-08-29 13:31
VLAI?
Title
Tenda AC21/AC23 GetParentControlInfo stack-based overflow
Summary
A security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. Such manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
lxyilu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9605",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-29T13:31:03.332380Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-29T13:31:06.430Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC23/Stack-Based%20Buffer%20Overflow%20in%20Tenda%20Wi-Fi%205%20Router%20AC23%EF%BC%88AC23V1.0re_V16.03.07.52%EF%BC%89.md"
          },
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC21/AC21V1.0re_V16.03.08.16.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        },
        {
          "product": "AC23",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "lxyilu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. Such manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC21 and AC23 16.03.08.16 ist eine Schwachstelle entdeckt worden. Betroffen ist die Funktion GetParentControlInfo der Datei /goform/GetParentControlInfo. Durch das Manipulieren des Arguments mac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Ein Angriff ist aus der Distanz m\u00f6glich. Der Exploit ist \u00f6ffentlich verf\u00fcgbar und k\u00f6nnte genutzt werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 10,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-29T02:02:08.778Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-321783 | Tenda AC21/AC23 GetParentControlInfo stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.321783"
        },
        {
          "name": "VDB-321783 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.321783"
        },
        {
          "name": "Submit #636545 | Tenda Wi-Fi 5 Router AC21 AC21V1.0re_V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.636545"
        },
        {
          "name": "Submit #636548 | Tenda Wi-Fi 5 Router AC23 AC23V1.0re_V16.03.07.52 Buffer Overflow (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.636548"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC21/AC21V1.0re_V16.03.08.16.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC23/Stack-Based%20Buffer%20Overflow%20in%20Tenda%20Wi-Fi%205%20Router%20AC23%EF%BC%88AC23V1.0re_V16.03.07.52%EF%BC%89.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-08-28T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-08-28T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-08-28T17:27:38.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21/AC23 GetParentControlInfo stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-9605",
    "datePublished": "2025-08-29T02:02:08.778Z",
    "dateReserved": "2025-08-28T15:21:33.747Z",
    "dateUpdated": "2025-08-29T13:31:06.430Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-24333 (GCVE-0-2023-24333)

Vulnerability from nvd – Published: 2024-02-21 00:00 – Updated: 2024-08-28 18:01
VLAI?
Summary
A stack overflow vulnerability in Tenda AC21 with firmware version US_AC21V1.0re_V16.03.08.15_cn_TDC01 allows attackers to run arbitrary commands via crafted POST request to /goform/openSchedWifi.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T10:56:03.506Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/caoyebo/CVE/tree/main/TENDA%20AC21%20-%20CVE-2023-24333"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac21_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac21_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "us_ac21v1.0re_v16.03.08.15_cn_tdc01"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-24333",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-15T20:31:34.680982Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-94",
                "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-28T18:01:07.316Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A stack overflow vulnerability in Tenda AC21 with firmware version US_AC21V1.0re_V16.03.08.15_cn_TDC01 allows attackers to run arbitrary commands via crafted POST request to /goform/openSchedWifi."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-21T20:30:20.718167",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/caoyebo/CVE/tree/main/TENDA%20AC21%20-%20CVE-2023-24333"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-24333",
    "datePublished": "2024-02-21T00:00:00",
    "dateReserved": "2023-01-23T00:00:00",
    "dateUpdated": "2024-08-28T18:01:07.316Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-44163 (GCVE-0-2022-44163)

Vulnerability from nvd – Published: 2022-11-21 00:00 – Updated: 2025-04-29 16:11
VLAI?
Summary
Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via function formSetMacFilterCfg.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:47:05.648Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://drive.google.com/file/d/1jmwNxVKc-HfsiuDNApgX_exbYtCalSSK/view?usp=sharing"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-44163",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-29T16:11:11.449322Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-787",
                "description": "CWE-787 Out-of-bounds Write",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-29T16:11:37.007Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via function formSetMacFilterCfg."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-21T00:00:00.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://drive.google.com/file/d/1jmwNxVKc-HfsiuDNApgX_exbYtCalSSK/view?usp=sharing"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-44163",
    "datePublished": "2022-11-21T00:00:00.000Z",
    "dateReserved": "2022-10-30T00:00:00.000Z",
    "dateUpdated": "2025-04-29T16:11:37.007Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-44158 (GCVE-0-2022-44158)

Vulnerability from nvd – Published: 2022-11-21 00:00 – Updated: 2025-04-29 16:16
VLAI?
Summary
Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via function via set_device_name.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:47:05.461Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://drive.google.com/file/d/11PSsUpLmLCl0-eO565TLbVavzfP5aWdG/view?usp=sharing"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-44158",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-29T16:15:52.327677Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-787",
                "description": "CWE-787 Out-of-bounds Write",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-29T16:16:19.840Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via function via set_device_name."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-21T00:00:00.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://drive.google.com/file/d/11PSsUpLmLCl0-eO565TLbVavzfP5aWdG/view?usp=sharing"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-44158",
    "datePublished": "2022-11-21T00:00:00.000Z",
    "dateReserved": "2022-10-30T00:00:00.000Z",
    "dateUpdated": "2025-04-29T16:16:19.840Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-40076 (GCVE-0-2022-40076)

Vulnerability from nvd – Published: 2022-09-19 14:29 – Updated: 2024-08-03 12:14
VLAI?
Summary
Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, function: fromSetWifiGusetBasic.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T12:14:39.793Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/xxy1126/Vuln/tree/main/Tenda%20AC21/4"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, function: fromSetWifiGusetBasic."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-19T14:29:42",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/xxy1126/Vuln/tree/main/Tenda%20AC21/4"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-40076",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, function: fromSetWifiGusetBasic."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/xxy1126/Vuln/tree/main/Tenda%20AC21/4",
              "refsource": "MISC",
              "url": "https://github.com/xxy1126/Vuln/tree/main/Tenda%20AC21/4"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-40076",
    "datePublished": "2022-09-19T14:29:42",
    "dateReserved": "2022-09-06T00:00:00",
    "dateUpdated": "2024-08-03T12:14:39.793Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-40075 (GCVE-0-2022-40075)

Vulnerability from nvd – Published: 2022-09-19 14:30 – Updated: 2024-08-03 12:14
VLAI?
Summary
Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, form_fast_setting_wifi_set.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T12:14:39.466Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/xxy1126/Vuln/tree/main/Tenda%20AC21/1"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, form_fast_setting_wifi_set."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-19T14:30:29",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/xxy1126/Vuln/tree/main/Tenda%20AC21/1"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-40075",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, form_fast_setting_wifi_set."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/xxy1126/Vuln/tree/main/Tenda%20AC21/1",
              "refsource": "MISC",
              "url": "https://github.com/xxy1126/Vuln/tree/main/Tenda%20AC21/1"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-40075",
    "datePublished": "2022-09-19T14:30:29",
    "dateReserved": "2022-09-06T00:00:00",
    "dateUpdated": "2024-08-03T12:14:39.466Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-13446 (GCVE-0-2025-13446)

Vulnerability from cvelistv5 – Published: 2025-11-20 02:32 – Updated: 2025-11-20 14:52
VLAI?
Title
Tenda AC21 SetSysTimeCfg stack-based overflow
Summary
A vulnerability has been found in Tenda AC21 16.03.08.16. This vulnerability affects unknown code of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone/time leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
jiahui288 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-13446",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-20T14:16:02.059248Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-20T14:52:07.354Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN8.md"
          },
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN9.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "jiahui288 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda AC21 16.03.08.16. This vulnerability affects unknown code of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone/time leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T02:32:07.969Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-333018 | Tenda AC21 SetSysTimeCfg stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.333018"
        },
        {
          "name": "VDB-333018 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.333018"
        },
        {
          "name": "Submit #694425 | Tenda AC21 V16.03.08.16  Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.694425"
        },
        {
          "name": "Submit #694430 | Tenda AC21 V16.03.08.16  Buffer Overflow (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.694430"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN8.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN9.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-11-19T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-11-19T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-11-19T20:19:45.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 SetSysTimeCfg stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-13446",
    "datePublished": "2025-11-20T02:32:07.969Z",
    "dateReserved": "2025-11-19T19:14:38.513Z",
    "dateUpdated": "2025-11-20T14:52:07.354Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-13445 (GCVE-0-2025-13445)

Vulnerability from cvelistv5 – Published: 2025-11-20 02:02 – Updated: 2025-11-20 14:52
VLAI?
Title
Tenda AC21 SetIpMacBind stack-based overflow
Summary
A flaw has been found in Tenda AC21 16.03.08.16. This affects an unknown part of the file /goform/SetIpMacBind. Executing manipulation of the argument list can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been published and may be used.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
jiahui288 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-13445",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-20T14:17:02.610671Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-20T14:52:14.900Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN7.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "jiahui288 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw has been found in Tenda AC21 16.03.08.16. This affects an unknown part of the file /goform/SetIpMacBind. Executing manipulation of the argument list can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been published and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T02:02:09.585Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-333017 | Tenda AC21 SetIpMacBind stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.333017"
        },
        {
          "name": "VDB-333017 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.333017"
        },
        {
          "name": "Submit #694066 | Tenda AC21 V16.03.08.16  Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.694066"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN7.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-11-19T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-11-19T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-11-19T20:19:41.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 SetIpMacBind stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-13445",
    "datePublished": "2025-11-20T02:02:09.585Z",
    "dateReserved": "2025-11-19T19:14:36.023Z",
    "dateUpdated": "2025-11-20T14:52:14.900Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-65220 (GCVE-0-2025-65220)

Vulnerability from cvelistv5 – Published: 2025-11-20 00:00 – Updated: 2025-11-20 15:27
VLAI?
Summary
Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow in: /goform/SetVirtualServerCfg via the list parameter.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-65220",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-20T15:26:49.120930Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-20T15:27:20.035Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow in: /goform/SetVirtualServerCfg via the list parameter."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T15:02:57.111Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-65220",
    "datePublished": "2025-11-20T00:00:00.000Z",
    "dateReserved": "2025-11-18T00:00:00.000Z",
    "dateUpdated": "2025-11-20T15:27:20.035Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-65223 (GCVE-0-2025-65223)

Vulnerability from cvelistv5 – Published: 2025-11-20 00:00 – Updated: 2025-11-20 15:30
VLAI?
Summary
Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the urls parameter of /goform/saveParentControlInfo.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-65223",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-20T15:29:47.324586Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-20T15:30:24.490Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the urls parameter of /goform/saveParentControlInfo."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T14:55:18.918Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN4.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-65223",
    "datePublished": "2025-11-20T00:00:00.000Z",
    "dateReserved": "2025-11-18T00:00:00.000Z",
    "dateUpdated": "2025-11-20T15:30:24.490Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-65222 (GCVE-0-2025-65222)

Vulnerability from cvelistv5 – Published: 2025-11-20 00:00 – Updated: 2025-11-20 15:28
VLAI?
Summary
Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the rebootTime parameter of /goform/SetSysAutoRebbotCfg.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-65222",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-20T15:27:57.732201Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-20T15:28:14.424Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the rebootTime parameter of /goform/SetSysAutoRebbotCfg."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T14:57:26.202Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN3.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-65222",
    "datePublished": "2025-11-20T00:00:00.000Z",
    "dateReserved": "2025-11-18T00:00:00.000Z",
    "dateUpdated": "2025-11-20T15:28:14.424Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-65221 (GCVE-0-2025-65221)

Vulnerability from cvelistv5 – Published: 2025-11-20 00:00 – Updated: 2025-11-20 15:29
VLAI?
Summary
Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the list parameter of /goform/setPptpUserList.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-65221",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-20T15:28:37.960092Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-20T15:29:04.604Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the list parameter of /goform/setPptpUserList."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T15:00:07.614Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN2.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-65221",
    "datePublished": "2025-11-20T00:00:00.000Z",
    "dateReserved": "2025-11-18T00:00:00.000Z",
    "dateUpdated": "2025-11-20T15:29:04.604Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-65226 (GCVE-0-2025-65226)

Vulnerability from cvelistv5 – Published: 2025-11-20 00:00 – Updated: 2025-11-20 15:31
VLAI?
Summary
Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the deviceId parameter in /goform/saveParentControlInfo.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-65226",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-20T15:31:02.534249Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-120",
                "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-20T15:31:42.041Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the deviceId parameter in /goform/saveParentControlInfo."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T14:48:56.814Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN5.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-65226",
    "datePublished": "2025-11-20T00:00:00.000Z",
    "dateReserved": "2025-11-18T00:00:00.000Z",
    "dateUpdated": "2025-11-20T15:31:42.041Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-12611 (GCVE-0-2025-12611)

Vulnerability from cvelistv5 – Published: 2025-11-03 02:02 – Updated: 2025-11-03 14:26
VLAI?
Title
Tenda AC21 SetPptpServerCfg formSetPPTPServer buffer overflow
Summary
A vulnerability was identified in Tenda AC21 16.03.08.16. This vulnerability affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIp leads to buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
CWE
Assigner
References
https://vuldb.com/?id.330906 vdb-entrytechnical-description
https://vuldb.com/?ctiid.330906 signaturepermissions-required
https://vuldb.com/?submit.678491 third-party-advisory
https://github.com/LX-LX88/cve/issues/10 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
LX-LX (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12611",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-03T14:16:45.645981Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-03T14:26:36.736Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LX-LX (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was identified in Tenda AC21 16.03.08.16. This vulnerability affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIp leads to buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC21 16.03.08.16 wurde eine Schwachstelle gefunden. Es geht dabei um die Funktion formSetPPTPServer der Datei /goform/SetPptpServerCfg. Mit der Manipulation des Arguments startIp mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit wurde der \u00d6ffentlichkeit bekannt gemacht und k\u00f6nnte verwendet werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-03T02:02:09.734Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-330906 | Tenda AC21 SetPptpServerCfg formSetPPTPServer buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.330906"
        },
        {
          "name": "VDB-330906 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.330906"
        },
        {
          "name": "Submit #678491 | Tenda AC21 V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.678491"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/LX-LX88/cve/issues/10"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-11-02T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-11-02T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-11-02T07:33:49.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 SetPptpServerCfg formSetPPTPServer buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-12611",
    "datePublished": "2025-11-03T02:02:09.734Z",
    "dateReserved": "2025-11-02T06:28:46.133Z",
    "dateUpdated": "2025-11-03T14:26:36.736Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-11091 (GCVE-0-2025-11091)

Vulnerability from cvelistv5 – Published: 2025-09-28 01:32 – Updated: 2025-09-29 14:48
VLAI?
Title
Tenda AC21 SetStaticRouteCfg sscanf buffer overflow
Summary
A security flaw has been discovered in Tenda AC21 up to 16.03.08.16. Affected by this vulnerability is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. The attack can be launched remotely. The exploit has been released to the public and may be exploited.
CWE
Assigner
References
https://vuldb.com/?id.326173 vdb-entrytechnical-description
https://vuldb.com/?ctiid.326173 signaturepermissions-required
https://vuldb.com/?submit.661806 third-party-advisory
https://github.com/maximdevere/CVE2/issues/2 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.0
Affected: 16.03.08.1
Affected: 16.03.08.2
Affected: 16.03.08.3
Affected: 16.03.08.4
Affected: 16.03.08.5
Affected: 16.03.08.6
Affected: 16.03.08.7
Affected: 16.03.08.8
Affected: 16.03.08.9
Affected: 16.03.08.10
Affected: 16.03.08.11
Affected: 16.03.08.12
Affected: 16.03.08.13
Affected: 16.03.08.14
Affected: 16.03.08.15
Affected: 16.03.08.16
Create a notification for this product.
Credits
MaximDeVere (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11091",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-29T14:48:52.752774Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-29T14:48:57.508Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/maximdevere/CVE2/issues/2"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.0"
            },
            {
              "status": "affected",
              "version": "16.03.08.1"
            },
            {
              "status": "affected",
              "version": "16.03.08.2"
            },
            {
              "status": "affected",
              "version": "16.03.08.3"
            },
            {
              "status": "affected",
              "version": "16.03.08.4"
            },
            {
              "status": "affected",
              "version": "16.03.08.5"
            },
            {
              "status": "affected",
              "version": "16.03.08.6"
            },
            {
              "status": "affected",
              "version": "16.03.08.7"
            },
            {
              "status": "affected",
              "version": "16.03.08.8"
            },
            {
              "status": "affected",
              "version": "16.03.08.9"
            },
            {
              "status": "affected",
              "version": "16.03.08.10"
            },
            {
              "status": "affected",
              "version": "16.03.08.11"
            },
            {
              "status": "affected",
              "version": "16.03.08.12"
            },
            {
              "status": "affected",
              "version": "16.03.08.13"
            },
            {
              "status": "affected",
              "version": "16.03.08.14"
            },
            {
              "status": "affected",
              "version": "16.03.08.15"
            },
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "MaximDeVere (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security flaw has been discovered in Tenda AC21 up to 16.03.08.16. Affected by this vulnerability is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. The attack can be launched remotely. The exploit has been released to the public and may be exploited."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda AC21 up to 16.03.08.16 entdeckt. Dabei geht es um die Funktion sscanf der Datei /goform/SetStaticRouteCfg. Dank Manipulation des Arguments list mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff l\u00e4sst sich \u00fcber das Netzwerk starten. Der Exploit ist \u00f6ffentlich verf\u00fcgbar und k\u00f6nnte genutzt werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-28T01:32:10.696Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-326173 | Tenda AC21 SetStaticRouteCfg sscanf buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.326173"
        },
        {
          "name": "VDB-326173 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.326173"
        },
        {
          "name": "Submit #661806 | Shenzhen Tenda Technology Co.,Ltd. AC21 \u003c= V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.661806"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/maximdevere/CVE2/issues/2"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-09-27T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-09-27T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-09-27T07:31:48.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 SetStaticRouteCfg sscanf buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-11091",
    "datePublished": "2025-09-28T01:32:10.696Z",
    "dateReserved": "2025-09-27T05:26:44.839Z",
    "dateUpdated": "2025-09-29T14:48:57.508Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-10838 (GCVE-0-2025-10838)

Vulnerability from cvelistv5 – Published: 2025-09-23 04:32 – Updated: 2025-09-23 19:12
VLAI?
Title
Tenda AC21 WifiExtraSet sub_45BB10 buffer overflow
Summary
A vulnerability was identified in Tenda AC21 16.03.08.16. The affected element is the function sub_45BB10 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to buffer overflow. It is possible to initiate the attack remotely. The exploit is publicly available and might be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
QMSSDXN (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-10838",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-23T19:12:21.343557Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-23T19:12:30.355Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "QMSSDXN (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was identified in Tenda AC21 16.03.08.16. The affected element is the function sub_45BB10 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to buffer overflow. It is possible to initiate the attack remotely. The exploit is publicly available and might be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC21 16.03.08.16 gefunden. Es geht dabei um die Funktion sub_45BB10 der Datei /goform/WifiExtraSet. Durch Manipulieren des Arguments wpapsk_crypto mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-23T04:32:07.071Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-325200 | Tenda AC21 WifiExtraSet sub_45BB10 buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.325200"
        },
        {
          "name": "VDB-325200 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.325200"
        },
        {
          "name": "Submit #657126 | Tenda AC21 \u2264V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.657126"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/lin-3-start/lin-cve/blob/main/Tenda%20AC21/Tenda%20AC21%20Buffer%20overflow.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/lin-3-start/lin-cve/blob/main/Tenda%20AC21/Tenda%20AC21%20Buffer%20overflow.md#poc"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-09-22T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-09-22T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-09-22T07:15:16.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 WifiExtraSet sub_45BB10 buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-10838",
    "datePublished": "2025-09-23T04:32:07.071Z",
    "dateReserved": "2025-09-22T05:10:13.621Z",
    "dateUpdated": "2025-09-23T19:12:30.355Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-9605 (GCVE-0-2025-9605)

Vulnerability from cvelistv5 – Published: 2025-08-29 02:02 – Updated: 2025-08-29 13:31
VLAI?
Title
Tenda AC21/AC23 GetParentControlInfo stack-based overflow
Summary
A security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. Such manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
lxyilu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9605",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-29T13:31:03.332380Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-29T13:31:06.430Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC23/Stack-Based%20Buffer%20Overflow%20in%20Tenda%20Wi-Fi%205%20Router%20AC23%EF%BC%88AC23V1.0re_V16.03.07.52%EF%BC%89.md"
          },
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC21/AC21V1.0re_V16.03.08.16.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        },
        {
          "product": "AC23",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "lxyilu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. Such manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC21 and AC23 16.03.08.16 ist eine Schwachstelle entdeckt worden. Betroffen ist die Funktion GetParentControlInfo der Datei /goform/GetParentControlInfo. Durch das Manipulieren des Arguments mac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Ein Angriff ist aus der Distanz m\u00f6glich. Der Exploit ist \u00f6ffentlich verf\u00fcgbar und k\u00f6nnte genutzt werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 10,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-29T02:02:08.778Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-321783 | Tenda AC21/AC23 GetParentControlInfo stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.321783"
        },
        {
          "name": "VDB-321783 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.321783"
        },
        {
          "name": "Submit #636545 | Tenda Wi-Fi 5 Router AC21 AC21V1.0re_V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.636545"
        },
        {
          "name": "Submit #636548 | Tenda Wi-Fi 5 Router AC23 AC23V1.0re_V16.03.07.52 Buffer Overflow (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.636548"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC21/AC21V1.0re_V16.03.08.16.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC23/Stack-Based%20Buffer%20Overflow%20in%20Tenda%20Wi-Fi%205%20Router%20AC23%EF%BC%88AC23V1.0re_V16.03.07.52%EF%BC%89.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-08-28T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-08-28T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-08-28T17:27:38.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21/AC23 GetParentControlInfo stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-9605",
    "datePublished": "2025-08-29T02:02:08.778Z",
    "dateReserved": "2025-08-28T15:21:33.747Z",
    "dateUpdated": "2025-08-29T13:31:06.430Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-24333 (GCVE-0-2023-24333)

Vulnerability from cvelistv5 – Published: 2024-02-21 00:00 – Updated: 2024-08-28 18:01
VLAI?
Summary
A stack overflow vulnerability in Tenda AC21 with firmware version US_AC21V1.0re_V16.03.08.15_cn_TDC01 allows attackers to run arbitrary commands via crafted POST request to /goform/openSchedWifi.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T10:56:03.506Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/caoyebo/CVE/tree/main/TENDA%20AC21%20-%20CVE-2023-24333"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac21_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac21_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "us_ac21v1.0re_v16.03.08.15_cn_tdc01"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-24333",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-15T20:31:34.680982Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-94",
                "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-28T18:01:07.316Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A stack overflow vulnerability in Tenda AC21 with firmware version US_AC21V1.0re_V16.03.08.15_cn_TDC01 allows attackers to run arbitrary commands via crafted POST request to /goform/openSchedWifi."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-21T20:30:20.718167",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/caoyebo/CVE/tree/main/TENDA%20AC21%20-%20CVE-2023-24333"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-24333",
    "datePublished": "2024-02-21T00:00:00",
    "dateReserved": "2023-01-23T00:00:00",
    "dateUpdated": "2024-08-28T18:01:07.316Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-44158 (GCVE-0-2022-44158)

Vulnerability from cvelistv5 – Published: 2022-11-21 00:00 – Updated: 2025-04-29 16:16
VLAI?
Summary
Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via function via set_device_name.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:47:05.461Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://drive.google.com/file/d/11PSsUpLmLCl0-eO565TLbVavzfP5aWdG/view?usp=sharing"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-44158",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-29T16:15:52.327677Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-787",
                "description": "CWE-787 Out-of-bounds Write",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-29T16:16:19.840Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via function via set_device_name."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-21T00:00:00.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://drive.google.com/file/d/11PSsUpLmLCl0-eO565TLbVavzfP5aWdG/view?usp=sharing"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-44158",
    "datePublished": "2022-11-21T00:00:00.000Z",
    "dateReserved": "2022-10-30T00:00:00.000Z",
    "dateUpdated": "2025-04-29T16:16:19.840Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-44163 (GCVE-0-2022-44163)

Vulnerability from cvelistv5 – Published: 2022-11-21 00:00 – Updated: 2025-04-29 16:11
VLAI?
Summary
Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via function formSetMacFilterCfg.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:47:05.648Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://drive.google.com/file/d/1jmwNxVKc-HfsiuDNApgX_exbYtCalSSK/view?usp=sharing"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-44163",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-29T16:11:11.449322Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-787",
                "description": "CWE-787 Out-of-bounds Write",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-29T16:11:37.007Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via function formSetMacFilterCfg."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-21T00:00:00.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://drive.google.com/file/d/1jmwNxVKc-HfsiuDNApgX_exbYtCalSSK/view?usp=sharing"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-44163",
    "datePublished": "2022-11-21T00:00:00.000Z",
    "dateReserved": "2022-10-30T00:00:00.000Z",
    "dateUpdated": "2025-04-29T16:11:37.007Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}