Search
Find a vulnerability
Search criteria
6 vulnerabilities found for ac1200_t8 by totolink
CVE-2024-8078 (GCVE-0-2024-8078)
Vulnerability from nvd – Published: 2024-08-22 20:31 – Updated: 2024-08-23 14:50
VLAI
EPSS
VEX
Title
TOTOLINK AC1200 T8 setTracerouteCfg buffer overflow
Summary
A vulnerability was found in TOTOLINK AC1200 T8 4.1.5cu.862_B20230228. It has been declared as critical. This vulnerability affects the function setTracerouteCfg. The manipulation leads to buffer overflow. The attack can be initiated remotely. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-23 14:10 UTC
CWE
- CWE-120 - Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.275560 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.275560 | signaturepermissions-required |
| https://github.com/hawkteam404/RnD_Public/blob/ma… | related |
| https://www.totolink.net/ | product |
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:totolink:ac1200_t8:4.1.5cu.862_b20230228:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac1200_t8",
"vendor": "totolink",
"versions": [
{
"status": "affected",
"version": "4.1.5cu.862_b20230228"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8078",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-23T14:10:54.944198Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-23T14:50:50.604Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC1200 T8",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "4.1.5cu.862_B20230228"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in TOTOLINK AC1200 T8 4.1.5cu.862_B20230228. It has been declared as critical. This vulnerability affects the function setTracerouteCfg. The manipulation leads to buffer overflow. The attack can be initiated remotely. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In TOTOLINK AC1200 T8 4.1.5cu.862_B20230228 wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Es geht um die Funktion setTracerouteCfg. Durch Beeinflussen mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-22T20:31:06.560Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-275560 | TOTOLINK AC1200 T8 setTracerouteCfg buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.275560"
},
{
"name": "VDB-275560 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.275560"
},
{
"tags": [
"related"
],
"url": "https://github.com/hawkteam404/RnD_Public/blob/main/TOTOLink_AC1200_T8_OsCmdI_BOF.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-08-22T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-08-22T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-08-22T14:26:27.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK AC1200 T8 setTracerouteCfg buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-8078",
"datePublished": "2024-08-22T20:31:06.560Z",
"dateReserved": "2024-08-22T12:20:59.327Z",
"dateUpdated": "2024-08-23T14:50:50.604Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-8077 (GCVE-0-2024-8077)
Vulnerability from nvd – Published: 2024-08-22 20:00 – Updated: 2024-08-22 20:33
VLAI
EPSS
VEX
Title
TOTOLINK AC1200 T8 setTracerouteCfg os command injection
Summary
A vulnerability was found in TOTOLINK AC1200 T8 4.1.5cu.862_B20230228. It has been classified as critical. This affects the function setTracerouteCfg. The manipulation leads to os command injection. It is possible to initiate the attack remotely. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
6.3 (Medium)
6.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-22 20:32 UTC
CWE
- CWE-78 - OS Command Injection
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.275559 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.275559 | signaturepermissions-required |
| https://github.com/hawkteam404/RnD_Public/blob/ma… | related |
| https://www.totolink.net/ | product |
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:totolink:ac1200_t8:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac1200_t8",
"vendor": "totolink",
"versions": [
{
"status": "affected",
"version": "4.1.5cu.862_b20230228"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8077",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-22T20:32:09.945675Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-22T20:33:40.377Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC1200 T8",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "4.1.5cu.862_B20230228"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in TOTOLINK AC1200 T8 4.1.5cu.862_B20230228. It has been classified as critical. This affects the function setTracerouteCfg. The manipulation leads to os command injection. It is possible to initiate the attack remotely. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in TOTOLINK AC1200 T8 4.1.5cu.862_B20230228 ausgemacht. Sie wurde als kritisch eingestuft. Betroffen hiervon ist die Funktion setTracerouteCfg. Durch das Beeinflussen mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-22T20:00:09.118Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-275559 | TOTOLINK AC1200 T8 setTracerouteCfg os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.275559"
},
{
"name": "VDB-275559 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.275559"
},
{
"tags": [
"related"
],
"url": "https://github.com/hawkteam404/RnD_Public/blob/main/TOTOLink_AC1200_T8_OsCmdI_BOF.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-08-22T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-08-22T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-08-22T14:26:26.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK AC1200 T8 setTracerouteCfg os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-8077",
"datePublished": "2024-08-22T20:00:09.118Z",
"dateReserved": "2024-08-22T12:20:56.277Z",
"dateUpdated": "2024-08-22T20:33:40.377Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-8076 (GCVE-0-2024-8076)
Vulnerability from nvd – Published: 2024-08-22 20:00 – Updated: 2024-08-22 20:32
VLAI
EPSS
VEX
Title
TOTOLINK AC1200 T8 setDiagnosisCfg buffer overflow
Summary
A vulnerability was found in TOTOLINK AC1200 T8 4.1.5cu.862_B20230228 and classified as critical. Affected by this issue is the function setDiagnosisCfg. The manipulation leads to buffer overflow. The attack may be launched remotely. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-22 20:30 UTC
CWE
- CWE-120 - Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.275558 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.275558 | signaturepermissions-required |
| https://github.com/hawkteam404/RnD_Public/blob/ma… | related |
| https://www.totolink.net/ | product |
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:totolink:ac1200_t8:4.1.5cu.862_b20230228:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac1200_t8",
"vendor": "totolink",
"versions": [
{
"status": "affected",
"version": "4.1.5cu.862_b20230228"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8076",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-22T20:30:54.676329Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-22T20:32:31.329Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC1200 T8",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "4.1.5cu.862_B20230228"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in TOTOLINK AC1200 T8 4.1.5cu.862_B20230228 and classified as critical. Affected by this issue is the function setDiagnosisCfg. The manipulation leads to buffer overflow. The attack may be launched remotely. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in TOTOLINK AC1200 T8 4.1.5cu.862_B20230228 gefunden. Sie wurde als kritisch eingestuft. Betroffen davon ist die Funktion setDiagnosisCfg. Durch Manipulieren mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-22T20:00:06.847Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-275558 | TOTOLINK AC1200 T8 setDiagnosisCfg buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.275558"
},
{
"name": "VDB-275558 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.275558"
},
{
"tags": [
"related"
],
"url": "https://github.com/hawkteam404/RnD_Public/blob/main/TOTOLink_AC1200_T8_OsCmdI_BOF.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-08-22T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-08-22T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-08-22T14:26:24.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK AC1200 T8 setDiagnosisCfg buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-8076",
"datePublished": "2024-08-22T20:00:06.847Z",
"dateReserved": "2024-08-22T12:20:53.500Z",
"dateUpdated": "2024-08-22T20:32:31.329Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-8078 (GCVE-0-2024-8078)
Vulnerability from cvelistv5 – Published: 2024-08-22 20:31 – Updated: 2024-08-23 14:50
VLAI
EPSS
VEX
Title
TOTOLINK AC1200 T8 setTracerouteCfg buffer overflow
Summary
A vulnerability was found in TOTOLINK AC1200 T8 4.1.5cu.862_B20230228. It has been declared as critical. This vulnerability affects the function setTracerouteCfg. The manipulation leads to buffer overflow. The attack can be initiated remotely. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-23 14:10 UTC
CWE
- CWE-120 - Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.275560 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.275560 | signaturepermissions-required |
| https://github.com/hawkteam404/RnD_Public/blob/ma… | related |
| https://www.totolink.net/ | product |
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:totolink:ac1200_t8:4.1.5cu.862_b20230228:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac1200_t8",
"vendor": "totolink",
"versions": [
{
"status": "affected",
"version": "4.1.5cu.862_b20230228"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8078",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-23T14:10:54.944198Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-23T14:50:50.604Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC1200 T8",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "4.1.5cu.862_B20230228"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in TOTOLINK AC1200 T8 4.1.5cu.862_B20230228. It has been declared as critical. This vulnerability affects the function setTracerouteCfg. The manipulation leads to buffer overflow. The attack can be initiated remotely. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In TOTOLINK AC1200 T8 4.1.5cu.862_B20230228 wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Es geht um die Funktion setTracerouteCfg. Durch Beeinflussen mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-22T20:31:06.560Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-275560 | TOTOLINK AC1200 T8 setTracerouteCfg buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.275560"
},
{
"name": "VDB-275560 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.275560"
},
{
"tags": [
"related"
],
"url": "https://github.com/hawkteam404/RnD_Public/blob/main/TOTOLink_AC1200_T8_OsCmdI_BOF.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-08-22T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-08-22T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-08-22T14:26:27.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK AC1200 T8 setTracerouteCfg buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-8078",
"datePublished": "2024-08-22T20:31:06.560Z",
"dateReserved": "2024-08-22T12:20:59.327Z",
"dateUpdated": "2024-08-23T14:50:50.604Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-8077 (GCVE-0-2024-8077)
Vulnerability from cvelistv5 – Published: 2024-08-22 20:00 – Updated: 2024-08-22 20:33
VLAI
EPSS
VEX
Title
TOTOLINK AC1200 T8 setTracerouteCfg os command injection
Summary
A vulnerability was found in TOTOLINK AC1200 T8 4.1.5cu.862_B20230228. It has been classified as critical. This affects the function setTracerouteCfg. The manipulation leads to os command injection. It is possible to initiate the attack remotely. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
6.3 (Medium)
6.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-22 20:32 UTC
CWE
- CWE-78 - OS Command Injection
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.275559 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.275559 | signaturepermissions-required |
| https://github.com/hawkteam404/RnD_Public/blob/ma… | related |
| https://www.totolink.net/ | product |
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:totolink:ac1200_t8:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac1200_t8",
"vendor": "totolink",
"versions": [
{
"status": "affected",
"version": "4.1.5cu.862_b20230228"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8077",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-22T20:32:09.945675Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-22T20:33:40.377Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC1200 T8",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "4.1.5cu.862_B20230228"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in TOTOLINK AC1200 T8 4.1.5cu.862_B20230228. It has been classified as critical. This affects the function setTracerouteCfg. The manipulation leads to os command injection. It is possible to initiate the attack remotely. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in TOTOLINK AC1200 T8 4.1.5cu.862_B20230228 ausgemacht. Sie wurde als kritisch eingestuft. Betroffen hiervon ist die Funktion setTracerouteCfg. Durch das Beeinflussen mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-22T20:00:09.118Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-275559 | TOTOLINK AC1200 T8 setTracerouteCfg os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.275559"
},
{
"name": "VDB-275559 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.275559"
},
{
"tags": [
"related"
],
"url": "https://github.com/hawkteam404/RnD_Public/blob/main/TOTOLink_AC1200_T8_OsCmdI_BOF.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-08-22T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-08-22T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-08-22T14:26:26.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK AC1200 T8 setTracerouteCfg os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-8077",
"datePublished": "2024-08-22T20:00:09.118Z",
"dateReserved": "2024-08-22T12:20:56.277Z",
"dateUpdated": "2024-08-22T20:33:40.377Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-8076 (GCVE-0-2024-8076)
Vulnerability from cvelistv5 – Published: 2024-08-22 20:00 – Updated: 2024-08-22 20:32
VLAI
EPSS
VEX
Title
TOTOLINK AC1200 T8 setDiagnosisCfg buffer overflow
Summary
A vulnerability was found in TOTOLINK AC1200 T8 4.1.5cu.862_B20230228 and classified as critical. Affected by this issue is the function setDiagnosisCfg. The manipulation leads to buffer overflow. The attack may be launched remotely. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-22 20:30 UTC
CWE
- CWE-120 - Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.275558 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.275558 | signaturepermissions-required |
| https://github.com/hawkteam404/RnD_Public/blob/ma… | related |
| https://www.totolink.net/ | product |
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:totolink:ac1200_t8:4.1.5cu.862_b20230228:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac1200_t8",
"vendor": "totolink",
"versions": [
{
"status": "affected",
"version": "4.1.5cu.862_b20230228"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8076",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-22T20:30:54.676329Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-22T20:32:31.329Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC1200 T8",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "4.1.5cu.862_B20230228"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in TOTOLINK AC1200 T8 4.1.5cu.862_B20230228 and classified as critical. Affected by this issue is the function setDiagnosisCfg. The manipulation leads to buffer overflow. The attack may be launched remotely. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in TOTOLINK AC1200 T8 4.1.5cu.862_B20230228 gefunden. Sie wurde als kritisch eingestuft. Betroffen davon ist die Funktion setDiagnosisCfg. Durch Manipulieren mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-22T20:00:06.847Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-275558 | TOTOLINK AC1200 T8 setDiagnosisCfg buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.275558"
},
{
"name": "VDB-275558 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.275558"
},
{
"tags": [
"related"
],
"url": "https://github.com/hawkteam404/RnD_Public/blob/main/TOTOLink_AC1200_T8_OsCmdI_BOF.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-08-22T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-08-22T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-08-22T14:26:24.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK AC1200 T8 setDiagnosisCfg buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-8076",
"datePublished": "2024-08-22T20:00:06.847Z",
"dateReserved": "2024-08-22T12:20:53.500Z",
"dateUpdated": "2024-08-22T20:32:31.329Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}