Search criteria

184 vulnerabilities found for ac10_firmware by tenda

CVE-2026-5550 (GCVE-0-2026-5550)

Vulnerability from nvd – Published: 2026-04-05 08:00 – Updated: 2026-04-07 02:43
VLAI?
Title
Tenda AC10 httpd fromSysToolChangePwd stack-based overflow
Summary
A vulnerability was identified in Tenda AC10 16.03.10.10_multi_TDE01. This affects the function fromSysToolChangePwd of the file /bin/httpd. The manipulation leads to stack-based buffer overflow. The attack may be initiated remotely. Multiple endpoints might be affected.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10 Affected: 16.03.10.10_multi_TDE01
    cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
CoreNode (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-5550",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-07T02:42:51.272094Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-07T02:43:36.590Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.10.10_multi_TDE01"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "CoreNode (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was identified in Tenda AC10 16.03.10.10_multi_TDE01. This affects the function fromSysToolChangePwd of the file /bin/httpd. The manipulation leads to stack-based buffer overflow. The attack may be initiated remotely. Multiple endpoints might be affected."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-05T08:00:20.639Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-355314 | Tenda AC10 httpd fromSysToolChangePwd stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/355314"
        },
        {
          "name": "VDB-355314 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/355314/cti"
        },
        {
          "name": "Submit #782299 | Tenda AC10 V4 US_AC10V4.0si_V16.03.10.10_multi_TDE01 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/782299"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/somanyerrors/tenda-ac10v4-vulnerabilities/blob/main/findings/HIGH-01-getvalue-229-callers.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-04-04T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-04-04T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-04-04T15:33:28.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 httpd fromSysToolChangePwd stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-5550",
    "datePublished": "2026-04-05T08:00:20.639Z",
    "dateReserved": "2026-04-04T13:28:12.754Z",
    "dateUpdated": "2026-04-07T02:43:36.590Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-5549 (GCVE-0-2026-5549)

Vulnerability from nvd – Published: 2026-04-05 07:45 – Updated: 2026-04-06 16:21
VLAI?
Title
Tenda AC10 RSA 2048-bit Private Key privkeySrv.pem hard-coded key
Summary
A vulnerability was determined in Tenda AC10 16.03.10.10_multi_TDE01. Affected by this issue is some unknown functionality of the file /webroot_ro/pem/privkeySrv.pem of the component RSA 2048-bit Private Key Handler. Executing a manipulation can lead to use of hard-coded cryptographic key . The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
  • CWE-320 - Key Management Error
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10 Affected: 16.03.10.10_multi_TDE01
    cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
CoreNode (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-5549",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-06T16:20:59.428926Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-06T16:21:09.043Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "RSA 2048-bit Private Key Handler"
          ],
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.10.10_multi_TDE01"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "CoreNode (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was determined in Tenda AC10 16.03.10.10_multi_TDE01. Affected by this issue is some unknown functionality of the file /webroot_ro/pem/privkeySrv.pem of the component RSA 2048-bit Private Key Handler. Executing a manipulation can lead to use of hard-coded cryptographic key\r . The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N/E:POC/RL:W/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-320",
              "description": "Key Management Error",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-05T07:45:14.628Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-355313 | Tenda AC10 RSA 2048-bit Private Key privkeySrv.pem hard-coded key",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/vuln/355313"
        },
        {
          "name": "VDB-355313 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/355313/cti"
        },
        {
          "name": "Submit #782298 | Tenda AC10 V4 US_AC10V4.0si_V16.03.10.10_multi_TDE01 Cryptographic Issues",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/782298"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/somanyerrors/tenda-ac10v4-vulnerabilities/blob/main/findings/CRITICAL-05-exposed-rsa-private-key.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-04-04T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-04-04T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-04-04T15:33:25.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 RSA 2048-bit Private Key privkeySrv.pem hard-coded key"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-5549",
    "datePublished": "2026-04-05T07:45:14.628Z",
    "dateReserved": "2026-04-04T13:28:08.788Z",
    "dateUpdated": "2026-04-06T16:21:09.043Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-5548 (GCVE-0-2026-5548)

Vulnerability from nvd – Published: 2026-04-05 07:30 – Updated: 2026-04-06 17:57
VLAI?
Title
Tenda AC10 httpd fromSysToolChangePwd stack-based overflow
Summary
A vulnerability was found in Tenda AC10 16.03.10.10_multi_TDE01. Affected by this vulnerability is the function fromSysToolChangePwd of the file /bin/httpd. Performing a manipulation of the argument sys.userpass results in stack-based buffer overflow. The attack can be initiated remotely.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10 Affected: 16.03.10.10_multi_TDE01
    cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
CoreNode (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-5548",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-06T17:57:37.954410Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-06T17:57:47.036Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.10.10_multi_TDE01"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "CoreNode (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC10 16.03.10.10_multi_TDE01. Affected by this vulnerability is the function fromSysToolChangePwd of the file /bin/httpd. Performing a manipulation of the argument sys.userpass results in stack-based buffer overflow. The attack can be initiated remotely."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-05T07:30:15.665Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-355312 | Tenda AC10 httpd fromSysToolChangePwd stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/355312"
        },
        {
          "name": "VDB-355312 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/355312/cti"
        },
        {
          "name": "Submit #782297 | Tenda AC10 V4 US_AC10V4.0si_V16.03.10.10_multi_TDE01 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/782297"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/somanyerrors/tenda-ac10v4-vulnerabilities/blob/main/findings/CRITICAL-04-stackoverflow-fromsystoolchangepwd.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-04-04T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-04-04T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-04-04T15:33:22.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 httpd fromSysToolChangePwd stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-5548",
    "datePublished": "2026-04-05T07:30:15.665Z",
    "dateReserved": "2026-04-04T13:28:04.091Z",
    "dateUpdated": "2026-04-06T17:57:47.036Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-5547 (GCVE-0-2026-5547)

Vulnerability from nvd – Published: 2026-04-05 07:15 – Updated: 2026-04-06 14:51
VLAI?
Title
Tenda AC10 httpd formAddMacfilterRule os command injection
Summary
A vulnerability has been found in Tenda AC10 16.03.10.10_multi_TDE01. Affected is the function formAddMacfilterRule of the file /bin/httpd. Such manipulation leads to os command injection. It is possible to launch the attack remotely. Multiple endpoints might be affected.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10 Affected: 16.03.10.10_multi_TDE01
    cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
CoreNode (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-5547",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-06T14:02:32.706573Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-06T14:51:06.247Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.10.10_multi_TDE01"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "CoreNode (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda AC10 16.03.10.10_multi_TDE01. Affected is the function formAddMacfilterRule of the file /bin/httpd. Such manipulation leads to os command injection. It is possible to launch the attack remotely. Multiple endpoints might be affected."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:X/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:X/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:ND/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "OS Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-05T07:15:15.874Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-355311 | Tenda AC10 httpd formAddMacfilterRule os command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/355311"
        },
        {
          "name": "VDB-355311 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/355311/cti"
        },
        {
          "name": "Submit #782296 | Tenda AC10 V4 US_AC10V4.0si_V16.03.10.10_multi_TDE01 OS Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/782296"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/somanyerrors/tenda-ac10v4-vulnerabilities/blob/main/findings/CRITICAL-03-command-injection-formaddmacfilterrule.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-04-04T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-04-04T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-04-04T15:33:19.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 httpd formAddMacfilterRule os command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-5547",
    "datePublished": "2026-04-05T07:15:15.874Z",
    "dateReserved": "2026-04-04T13:27:55.189Z",
    "dateUpdated": "2026-04-06T14:51:06.247Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-67074 (GCVE-0-2025-67074)

Vulnerability from nvd – Published: 2025-12-17 00:00 – Updated: 2025-12-18 18:52
VLAI?
Summary
A Buffer overflow vulnerability in function fromAdvSetMacMtuWan of bin httpd in Tenda AC10V4.0 V16.03.10.20 allows remote attackers to cause denial of service and possibly code execution by sending a post request with a crafted payload (field `serverName`) to /goform/AdvSetMacMtuWan.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-67074",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-18T16:13:14.832272Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-120",
                "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-18T18:52:29.602Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/johnathanhuutri/CVEReport/tree/master/CVE-2025-67074"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A Buffer overflow vulnerability in function fromAdvSetMacMtuWan of bin httpd in Tenda AC10V4.0 V16.03.10.20 allows remote attackers to cause denial of service and possibly code execution by sending a post request with a crafted payload (field `serverName`) to /goform/AdvSetMacMtuWan."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-17T19:17:31.870Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/johnathanhuutri/CVEReport/tree/master/CVE-2025-67074"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-67074",
    "datePublished": "2025-12-17T00:00:00.000Z",
    "dateReserved": "2025-12-08T00:00:00.000Z",
    "dateUpdated": "2025-12-18T18:52:29.602Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-67073 (GCVE-0-2025-67073)

Vulnerability from nvd – Published: 2025-12-17 00:00 – Updated: 2025-12-17 19:28
VLAI?
Summary
A Buffer overflow vulnerability in function fromAdvSetMacMtuWan of bin httpd in Tenda AC10V4.0 V16.03.10.20 allows remote attackers to cause denial of service and possibly code execution by sending a post request with a crafted payload (field `serviceName`) to /goform/AdvSetMacMtuWan.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-67073",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-17T19:26:03.887312Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-120",
                "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-17T19:28:39.953Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A Buffer overflow vulnerability in function fromAdvSetMacMtuWan of bin httpd in Tenda AC10V4.0 V16.03.10.20 allows remote attackers to cause denial of service and possibly code execution by sending a post request with a crafted payload (field `serviceName`) to /goform/AdvSetMacMtuWan."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-17T19:13:55.920Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/johnathanhuutri/CVEReport/tree/master/CVE-2025-67073"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-67073",
    "datePublished": "2025-12-17T00:00:00.000Z",
    "dateReserved": "2025-12-08T00:00:00.000Z",
    "dateUpdated": "2025-12-17T19:28:39.953Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-12622 (GCVE-0-2025-12622)

Vulnerability from nvd – Published: 2025-11-03 07:32 – Updated: 2026-02-24 06:23
VLAI?
Title
Tenda AC10 SysRunCmd formSysRunCmd buffer overflow
Summary
A vulnerability was determined in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function formSysRunCmd of the file /goform/SysRunCmd. This manipulation of the argument getui causes buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10 Affected: 16.03.10.13
    cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
1935648903 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12622",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-03T16:06:43.662517Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-03T16:06:54.102Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.10.13"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "1935648903 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was determined in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function formSysRunCmd of the file /goform/SysRunCmd. This manipulation of the argument getui causes buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-24T06:23:57.662Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-330914 | Tenda AC10 SysRunCmd formSysRunCmd buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.330914"
        },
        {
          "name": "VDB-330914 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.330914"
        },
        {
          "name": "Submit #678889 | tenda AC10V4.0 V16.03.10.13 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.678889"
        },
        {
          "tags": [
            "broken-link"
          ],
          "url": "https://www.yuque.com/ba1ma0-an29k/nnxoap/rg8eug0zk8ep3zne?singleDoc"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://pan.baidu.com/s/1Jl1zy5niigg1XYm8ZCh_Lg"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-11-02T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-11-02T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-11-03T10:29:11.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 SysRunCmd formSysRunCmd buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-12622",
    "datePublished": "2025-11-03T07:32:13.624Z",
    "dateReserved": "2025-11-02T17:42:29.275Z",
    "dateUpdated": "2026-02-24T06:23:57.662Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-57220 (GCVE-0-2025-57220)

Vulnerability from nvd – Published: 2025-08-28 00:00 – Updated: 2025-08-28 20:20
VLAI?
Summary
An input validation flaw in the 'ate' service of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 to escalate privileges to root via a crafted UDP packet.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-57220",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-28T20:19:48.800346Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-20",
                "description": "CWE-20 Improper Input Validation",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-28T20:20:21.748Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An input validation flaw in the \u0027ate\u0027 service of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 to escalate privileges to root via a crafted UDP packet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-28T18:51:44.373Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://plaid-knot-11b.notion.site/Unauthenticated-Remote-Root-Shell-via-Input-Validation-Flaw-in-ate-Service-on-Tenda-AC10-V4-0-23fb3e9cce32804d93aad7e79a82a7aa?source=copy_link"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-57220",
    "datePublished": "2025-08-28T00:00:00.000Z",
    "dateReserved": "2025-08-17T00:00:00.000Z",
    "dateUpdated": "2025-08-28T20:20:21.748Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-57219 (GCVE-0-2025-57219)

Vulnerability from nvd – Published: 2025-08-28 00:00 – Updated: 2025-08-28 19:56
VLAI?
Summary
Incorrect access control in the endpoint /goform/ate of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 allows attackers to escalate privileges or access sensitive components via a crafted request.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-57219",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-28T19:56:16.023454Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-284",
                "description": "CWE-284 Improper Access Control",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-28T19:56:47.808Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Incorrect access control in the endpoint /goform/ate of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 allows attackers to escalate privileges or access sensitive components via a crafted request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-28T18:49:07.173Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://plaid-knot-11b.notion.site/Unauthenticated-Remote-Access-to-ate-Debug-Interface-via-Improper-Access-Controls-in-Tenda-AC10-V4-23fb3e9cce328050a479e44a8c217a72?source=copy_link"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-57219",
    "datePublished": "2025-08-28T00:00:00.000Z",
    "dateReserved": "2025-08-17T00:00:00.000Z",
    "dateUpdated": "2025-08-28T19:56:47.808Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-57215 (GCVE-0-2025-57215)

Vulnerability from nvd – Published: 2025-08-28 00:00 – Updated: 2025-08-28 20:17
VLAI?
Summary
Tenda AC10 v4.0 firmware v16.03.10.20 was discovered to contain a stack overflow via the function get_parentControl_list_Info.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-57215",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-28T20:17:18.227778Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-28T20:17:48.826Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC10 v4.0 firmware v16.03.10.20 was discovered to contain a stack overflow via the function get_parentControl_list_Info."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-28T18:55:34.614Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.tenda.com.cn"
        },
        {
          "url": "https://plaid-knot-11b.notion.site/Heap-based-Buffer-Overflow-in-function-get_parentControl_list_Info-via-deviceId-parameter-Remote-at-23eb3e9cce328014a639f619bc14ed90"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-57215",
    "datePublished": "2025-08-28T00:00:00.000Z",
    "dateReserved": "2025-08-17T00:00:00.000Z",
    "dateUpdated": "2025-08-28T20:17:48.826Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-57218 (GCVE-0-2025-57218)

Vulnerability from nvd – Published: 2025-08-28 00:00 – Updated: 2025-08-28 20:10
VLAI?
Summary
Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the security_5g parameter in the function sub_46284C.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-57218",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-28T20:09:29.923911Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-28T20:10:03.408Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the security_5g parameter in the function sub_46284C."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-28T17:29:33.082Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://plaid-knot-11b.notion.site/Stack-Buffer-Overflow-in-goform-WifiBasicSet-via-Password-parameter-Remote-attacker-can-execute-ar-23fb3e9cce32807c883fc1b233e09eca?source=copy_link"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-57218",
    "datePublished": "2025-08-28T00:00:00.000Z",
    "dateReserved": "2025-08-17T00:00:00.000Z",
    "dateUpdated": "2025-08-28T20:10:03.408Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-57217 (GCVE-0-2025-57217)

Vulnerability from nvd – Published: 2025-08-28 00:00 – Updated: 2025-08-28 20:08
VLAI?
Summary
Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the Password parameter in the function R7WebsSecurityHandler.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-57217",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-28T20:08:13.498941Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-28T20:08:44.818Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the Password parameter in the function R7WebsSecurityHandler."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-28T17:25:54.467Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://plaid-knot-11b.notion.site/Stack-Buffer-Overflow-in-login-Auth-via-Password-parameter-Remote-attacker-can-execute-arbitrary-c-23fb3e9cce32800ba969f8b3a9f80bda?source=copy_link"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-57217",
    "datePublished": "2025-08-28T00:00:00.000Z",
    "dateReserved": "2025-08-17T00:00:00.000Z",
    "dateUpdated": "2025-08-28T20:08:44.818Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-9309 (GCVE-0-2025-9309)

Vulnerability from nvd – Published: 2025-08-21 16:32 – Updated: 2025-08-21 17:31
VLAI?
Title
Tenda AC10 MD5 Hash shadow hard-coded credentials
Summary
A vulnerability was found in Tenda AC10 16.03.10.13. Affected is an unknown function of the file /etc_ro/shadow of the component MD5 Hash Handler. Performing manipulation results in hard-coded credentials. The attack needs to be approached locally. A high degree of complexity is needed for the attack. The exploitability is told to be difficult. The exploit has been made public and could be used.
CWE
  • CWE-798 - Hard-coded Credentials
  • CWE-259 - Use of Hard-coded Password
Assigner
Impacted products
Vendor Product Version
Tenda AC10 Affected: 16.03.10.13
Create a notification for this product.
Credits
lxyilu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9309",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-21T17:22:51.502547Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-21T17:31:37.142Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC10/V4.0si_V16.03.10.13.md#steps-to-reproduce"
          },
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC10/V4.0si_V16.03.10.13.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "MD5 Hash Handler"
          ],
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.10.13"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "lxyilu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC10 16.03.10.13. Affected is an unknown function of the file /etc_ro/shadow of the component MD5 Hash Handler. Performing manipulation results in hard-coded credentials. The attack needs to be approached locally. A high degree of complexity is needed for the attack. The exploitability is told to be difficult. The exploit has been made public and could be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC10 16.03.10.13 wurde eine Schwachstelle gefunden. Es geht um eine nicht n\u00e4her bekannte Funktion der Datei /etc_ro/shadow der Komponente MD5 Hash Handler. Mittels Manipulieren mit unbekannten Daten kann eine hard-coded credentials-Schwachstelle ausgenutzt werden. Der Angriff muss lokal angegangen werden. Die Komplexit\u00e4t eines Angriffs ist eher hoch. Die Ausf\u00fchrung eines Exploits gilt als schwer. Die Ausnutzung wurde ver\u00f6ffentlicht und kann verwendet werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 2,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 2.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 2.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 1,
            "vectorString": "AV:L/AC:H/Au:S/C:P/I:N/A:N/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-259",
              "description": "Use of Hard-coded Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-21T16:32:08.672Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-320914 | Tenda AC10 MD5 Hash shadow hard-coded credentials",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/?id.320914"
        },
        {
          "name": "VDB-320914 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.320914"
        },
        {
          "name": "Submit #633585 | Tenda Tenda Wi-Fi 5 Router AC10 AC10V4.0si_V16.03.10.13 Hard-coded Credentials",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.633585"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC10/V4.0si_V16.03.10.13.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC10/V4.0si_V16.03.10.13.md#steps-to-reproduce"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-08-21T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-08-21T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-08-21T08:11:48.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 MD5 Hash shadow hard-coded credentials"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-9309",
    "datePublished": "2025-08-21T16:32:08.672Z",
    "dateReserved": "2025-08-21T06:06:44.302Z",
    "dateUpdated": "2025-08-21T17:31:37.142Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-8178 (GCVE-0-2025-8178)

Vulnerability from nvd – Published: 2025-07-26 04:32 – Updated: 2025-07-28 16:06
VLAI?
Title
Tenda AC10 RequestsProcessLaid heap-based overflow
Summary
A vulnerability classified as critical has been found in Tenda AC10 16.03.10.13. Affected is an unknown function of the file /goform/RequestsProcessLaid. The manipulation of the argument device1D leads to heap-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
URL Tags
https://vuldb.com/?id.317592 vdb-entrytechnical-description
https://vuldb.com/?ctiid.317592 signaturepermissions-required
https://vuldb.com/?submit.621811 third-party-advisory
https://www.yuque.com/ba1ma0-an29k/nnxoap/qkixf55… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC10 Affected: 16.03.10.13
Create a notification for this product.
Credits
Xuhsy (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-8178",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-28T16:06:11.336644Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-28T16:06:16.879Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.10.13"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Xuhsy (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Tenda AC10 16.03.10.13. Affected is an unknown function of the file /goform/RequestsProcessLaid. The manipulation of the argument device1D leads to heap-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda AC10 16.03.10.13 entdeckt. Es geht dabei um eine nicht klar definierte Funktion der Datei /goform/RequestsProcessLaid. Dank der Manipulation des Arguments device1D mit unbekannten Daten kann eine heap-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-26T04:32:10.022Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-317592 | Tenda AC10 RequestsProcessLaid heap-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.317592"
        },
        {
          "name": "VDB-317592 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.317592"
        },
        {
          "name": "Submit #621811 | Tenda AC10  V16.03.10.13 Heap overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.621811"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://www.yuque.com/ba1ma0-an29k/nnxoap/qkixf5578145igdt"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-07-25T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-07-25T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-07-25T10:19:20.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 RequestsProcessLaid heap-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-8178",
    "datePublished": "2025-07-26T04:32:10.022Z",
    "dateReserved": "2025-07-25T08:14:09.849Z",
    "dateUpdated": "2025-07-28T16:06:16.879Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-5629 (GCVE-0-2025-5629)

Vulnerability from nvd – Published: 2025-06-05 02:00 – Updated: 2025-06-05 14:09
VLAI?
Title
Tenda AC10 HTTP SetPptpServerCfg formSetPPTPServer buffer overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda AC10 up to 15.03.06.47. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg of the component HTTP Handler. The manipulation of the argument startIp/endIp leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
URL Tags
https://vuldb.com/?id.311115 vdb-entrytechnical-description
https://vuldb.com/?ctiid.311115 signaturepermissions-required
https://vuldb.com/?submit.589424 third-party-advisory
https://github.com/pfwqdxwdd/cve/blob/main/4.md exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC10 Affected: 15.03.06.0
Affected: 15.03.06.1
Affected: 15.03.06.2
Affected: 15.03.06.3
Affected: 15.03.06.4
Affected: 15.03.06.5
Affected: 15.03.06.6
Affected: 15.03.06.7
Affected: 15.03.06.8
Affected: 15.03.06.9
Affected: 15.03.06.10
Affected: 15.03.06.11
Affected: 15.03.06.12
Affected: 15.03.06.13
Affected: 15.03.06.14
Affected: 15.03.06.15
Affected: 15.03.06.16
Affected: 15.03.06.17
Affected: 15.03.06.18
Affected: 15.03.06.19
Affected: 15.03.06.20
Affected: 15.03.06.21
Affected: 15.03.06.22
Affected: 15.03.06.23
Affected: 15.03.06.24
Affected: 15.03.06.25
Affected: 15.03.06.26
Affected: 15.03.06.27
Affected: 15.03.06.28
Affected: 15.03.06.29
Affected: 15.03.06.30
Affected: 15.03.06.31
Affected: 15.03.06.32
Affected: 15.03.06.33
Affected: 15.03.06.34
Affected: 15.03.06.35
Affected: 15.03.06.36
Affected: 15.03.06.37
Affected: 15.03.06.38
Affected: 15.03.06.39
Affected: 15.03.06.40
Affected: 15.03.06.41
Affected: 15.03.06.42
Affected: 15.03.06.43
Affected: 15.03.06.44
Affected: 15.03.06.45
Affected: 15.03.06.46
Affected: 15.03.06.47
Create a notification for this product.
Credits
pfwqdxwdd (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-5629",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-05T13:56:33.195981Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-05T14:09:40.736Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "broken-link"
            ],
            "url": "https://github.com/pfwqdxwdd/cve/blob/main/4.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "HTTP Handler"
          ],
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.0"
            },
            {
              "status": "affected",
              "version": "15.03.06.1"
            },
            {
              "status": "affected",
              "version": "15.03.06.2"
            },
            {
              "status": "affected",
              "version": "15.03.06.3"
            },
            {
              "status": "affected",
              "version": "15.03.06.4"
            },
            {
              "status": "affected",
              "version": "15.03.06.5"
            },
            {
              "status": "affected",
              "version": "15.03.06.6"
            },
            {
              "status": "affected",
              "version": "15.03.06.7"
            },
            {
              "status": "affected",
              "version": "15.03.06.8"
            },
            {
              "status": "affected",
              "version": "15.03.06.9"
            },
            {
              "status": "affected",
              "version": "15.03.06.10"
            },
            {
              "status": "affected",
              "version": "15.03.06.11"
            },
            {
              "status": "affected",
              "version": "15.03.06.12"
            },
            {
              "status": "affected",
              "version": "15.03.06.13"
            },
            {
              "status": "affected",
              "version": "15.03.06.14"
            },
            {
              "status": "affected",
              "version": "15.03.06.15"
            },
            {
              "status": "affected",
              "version": "15.03.06.16"
            },
            {
              "status": "affected",
              "version": "15.03.06.17"
            },
            {
              "status": "affected",
              "version": "15.03.06.18"
            },
            {
              "status": "affected",
              "version": "15.03.06.19"
            },
            {
              "status": "affected",
              "version": "15.03.06.20"
            },
            {
              "status": "affected",
              "version": "15.03.06.21"
            },
            {
              "status": "affected",
              "version": "15.03.06.22"
            },
            {
              "status": "affected",
              "version": "15.03.06.23"
            },
            {
              "status": "affected",
              "version": "15.03.06.24"
            },
            {
              "status": "affected",
              "version": "15.03.06.25"
            },
            {
              "status": "affected",
              "version": "15.03.06.26"
            },
            {
              "status": "affected",
              "version": "15.03.06.27"
            },
            {
              "status": "affected",
              "version": "15.03.06.28"
            },
            {
              "status": "affected",
              "version": "15.03.06.29"
            },
            {
              "status": "affected",
              "version": "15.03.06.30"
            },
            {
              "status": "affected",
              "version": "15.03.06.31"
            },
            {
              "status": "affected",
              "version": "15.03.06.32"
            },
            {
              "status": "affected",
              "version": "15.03.06.33"
            },
            {
              "status": "affected",
              "version": "15.03.06.34"
            },
            {
              "status": "affected",
              "version": "15.03.06.35"
            },
            {
              "status": "affected",
              "version": "15.03.06.36"
            },
            {
              "status": "affected",
              "version": "15.03.06.37"
            },
            {
              "status": "affected",
              "version": "15.03.06.38"
            },
            {
              "status": "affected",
              "version": "15.03.06.39"
            },
            {
              "status": "affected",
              "version": "15.03.06.40"
            },
            {
              "status": "affected",
              "version": "15.03.06.41"
            },
            {
              "status": "affected",
              "version": "15.03.06.42"
            },
            {
              "status": "affected",
              "version": "15.03.06.43"
            },
            {
              "status": "affected",
              "version": "15.03.06.44"
            },
            {
              "status": "affected",
              "version": "15.03.06.45"
            },
            {
              "status": "affected",
              "version": "15.03.06.46"
            },
            {
              "status": "affected",
              "version": "15.03.06.47"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "pfwqdxwdd (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, was found in Tenda AC10 up to 15.03.06.47. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg of the component HTTP Handler. The manipulation of the argument startIp/endIp leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda AC10 bis 15.03.06.47 gefunden. Es betrifft die Funktion formSetPPTPServer der Datei /goform/SetPptpServerCfg der Komponente HTTP Handler. Mit der Manipulation des Arguments startIp/endIp mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-05T02:00:21.084Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-311115 | Tenda AC10 HTTP SetPptpServerCfg formSetPPTPServer buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.311115"
        },
        {
          "name": "VDB-311115 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.311115"
        },
        {
          "name": "Submit #589424 | Tenda AC10 \u003c=V15.03.06.47 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.589424"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/pfwqdxwdd/cve/blob/main/4.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-06-04T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-06-04T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-06-04T13:25:00.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 HTTP SetPptpServerCfg formSetPPTPServer buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-5629",
    "datePublished": "2025-06-05T02:00:21.084Z",
    "dateReserved": "2025-06-04T11:19:57.609Z",
    "dateUpdated": "2025-06-05T14:09:40.736Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2026-5550 (GCVE-0-2026-5550)

Vulnerability from cvelistv5 – Published: 2026-04-05 08:00 – Updated: 2026-04-07 02:43
VLAI?
Title
Tenda AC10 httpd fromSysToolChangePwd stack-based overflow
Summary
A vulnerability was identified in Tenda AC10 16.03.10.10_multi_TDE01. This affects the function fromSysToolChangePwd of the file /bin/httpd. The manipulation leads to stack-based buffer overflow. The attack may be initiated remotely. Multiple endpoints might be affected.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10 Affected: 16.03.10.10_multi_TDE01
    cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
CoreNode (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-5550",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-07T02:42:51.272094Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-07T02:43:36.590Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.10.10_multi_TDE01"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "CoreNode (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was identified in Tenda AC10 16.03.10.10_multi_TDE01. This affects the function fromSysToolChangePwd of the file /bin/httpd. The manipulation leads to stack-based buffer overflow. The attack may be initiated remotely. Multiple endpoints might be affected."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-05T08:00:20.639Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-355314 | Tenda AC10 httpd fromSysToolChangePwd stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/355314"
        },
        {
          "name": "VDB-355314 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/355314/cti"
        },
        {
          "name": "Submit #782299 | Tenda AC10 V4 US_AC10V4.0si_V16.03.10.10_multi_TDE01 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/782299"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/somanyerrors/tenda-ac10v4-vulnerabilities/blob/main/findings/HIGH-01-getvalue-229-callers.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-04-04T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-04-04T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-04-04T15:33:28.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 httpd fromSysToolChangePwd stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-5550",
    "datePublished": "2026-04-05T08:00:20.639Z",
    "dateReserved": "2026-04-04T13:28:12.754Z",
    "dateUpdated": "2026-04-07T02:43:36.590Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-5549 (GCVE-0-2026-5549)

Vulnerability from cvelistv5 – Published: 2026-04-05 07:45 – Updated: 2026-04-06 16:21
VLAI?
Title
Tenda AC10 RSA 2048-bit Private Key privkeySrv.pem hard-coded key
Summary
A vulnerability was determined in Tenda AC10 16.03.10.10_multi_TDE01. Affected by this issue is some unknown functionality of the file /webroot_ro/pem/privkeySrv.pem of the component RSA 2048-bit Private Key Handler. Executing a manipulation can lead to use of hard-coded cryptographic key . The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
  • CWE-320 - Key Management Error
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10 Affected: 16.03.10.10_multi_TDE01
    cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
CoreNode (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-5549",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-06T16:20:59.428926Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-06T16:21:09.043Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "RSA 2048-bit Private Key Handler"
          ],
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.10.10_multi_TDE01"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "CoreNode (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was determined in Tenda AC10 16.03.10.10_multi_TDE01. Affected by this issue is some unknown functionality of the file /webroot_ro/pem/privkeySrv.pem of the component RSA 2048-bit Private Key Handler. Executing a manipulation can lead to use of hard-coded cryptographic key\r . The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N/E:POC/RL:W/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-320",
              "description": "Key Management Error",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-05T07:45:14.628Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-355313 | Tenda AC10 RSA 2048-bit Private Key privkeySrv.pem hard-coded key",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/vuln/355313"
        },
        {
          "name": "VDB-355313 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/355313/cti"
        },
        {
          "name": "Submit #782298 | Tenda AC10 V4 US_AC10V4.0si_V16.03.10.10_multi_TDE01 Cryptographic Issues",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/782298"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/somanyerrors/tenda-ac10v4-vulnerabilities/blob/main/findings/CRITICAL-05-exposed-rsa-private-key.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-04-04T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-04-04T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-04-04T15:33:25.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 RSA 2048-bit Private Key privkeySrv.pem hard-coded key"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-5549",
    "datePublished": "2026-04-05T07:45:14.628Z",
    "dateReserved": "2026-04-04T13:28:08.788Z",
    "dateUpdated": "2026-04-06T16:21:09.043Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-5548 (GCVE-0-2026-5548)

Vulnerability from cvelistv5 – Published: 2026-04-05 07:30 – Updated: 2026-04-06 17:57
VLAI?
Title
Tenda AC10 httpd fromSysToolChangePwd stack-based overflow
Summary
A vulnerability was found in Tenda AC10 16.03.10.10_multi_TDE01. Affected by this vulnerability is the function fromSysToolChangePwd of the file /bin/httpd. Performing a manipulation of the argument sys.userpass results in stack-based buffer overflow. The attack can be initiated remotely.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10 Affected: 16.03.10.10_multi_TDE01
    cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
CoreNode (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-5548",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-06T17:57:37.954410Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-06T17:57:47.036Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.10.10_multi_TDE01"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "CoreNode (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC10 16.03.10.10_multi_TDE01. Affected by this vulnerability is the function fromSysToolChangePwd of the file /bin/httpd. Performing a manipulation of the argument sys.userpass results in stack-based buffer overflow. The attack can be initiated remotely."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-05T07:30:15.665Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-355312 | Tenda AC10 httpd fromSysToolChangePwd stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/355312"
        },
        {
          "name": "VDB-355312 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/355312/cti"
        },
        {
          "name": "Submit #782297 | Tenda AC10 V4 US_AC10V4.0si_V16.03.10.10_multi_TDE01 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/782297"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/somanyerrors/tenda-ac10v4-vulnerabilities/blob/main/findings/CRITICAL-04-stackoverflow-fromsystoolchangepwd.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-04-04T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-04-04T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-04-04T15:33:22.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 httpd fromSysToolChangePwd stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-5548",
    "datePublished": "2026-04-05T07:30:15.665Z",
    "dateReserved": "2026-04-04T13:28:04.091Z",
    "dateUpdated": "2026-04-06T17:57:47.036Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-5547 (GCVE-0-2026-5547)

Vulnerability from cvelistv5 – Published: 2026-04-05 07:15 – Updated: 2026-04-06 14:51
VLAI?
Title
Tenda AC10 httpd formAddMacfilterRule os command injection
Summary
A vulnerability has been found in Tenda AC10 16.03.10.10_multi_TDE01. Affected is the function formAddMacfilterRule of the file /bin/httpd. Such manipulation leads to os command injection. It is possible to launch the attack remotely. Multiple endpoints might be affected.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10 Affected: 16.03.10.10_multi_TDE01
    cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
CoreNode (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-5547",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-06T14:02:32.706573Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-06T14:51:06.247Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.10.10_multi_TDE01"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "CoreNode (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda AC10 16.03.10.10_multi_TDE01. Affected is the function formAddMacfilterRule of the file /bin/httpd. Such manipulation leads to os command injection. It is possible to launch the attack remotely. Multiple endpoints might be affected."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:X/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:X/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:ND/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "OS Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-05T07:15:15.874Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-355311 | Tenda AC10 httpd formAddMacfilterRule os command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/355311"
        },
        {
          "name": "VDB-355311 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/355311/cti"
        },
        {
          "name": "Submit #782296 | Tenda AC10 V4 US_AC10V4.0si_V16.03.10.10_multi_TDE01 OS Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/782296"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/somanyerrors/tenda-ac10v4-vulnerabilities/blob/main/findings/CRITICAL-03-command-injection-formaddmacfilterrule.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-04-04T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-04-04T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-04-04T15:33:19.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 httpd formAddMacfilterRule os command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-5547",
    "datePublished": "2026-04-05T07:15:15.874Z",
    "dateReserved": "2026-04-04T13:27:55.189Z",
    "dateUpdated": "2026-04-06T14:51:06.247Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-67073 (GCVE-0-2025-67073)

Vulnerability from cvelistv5 – Published: 2025-12-17 00:00 – Updated: 2025-12-17 19:28
VLAI?
Summary
A Buffer overflow vulnerability in function fromAdvSetMacMtuWan of bin httpd in Tenda AC10V4.0 V16.03.10.20 allows remote attackers to cause denial of service and possibly code execution by sending a post request with a crafted payload (field `serviceName`) to /goform/AdvSetMacMtuWan.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-67073",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-17T19:26:03.887312Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-120",
                "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-17T19:28:39.953Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A Buffer overflow vulnerability in function fromAdvSetMacMtuWan of bin httpd in Tenda AC10V4.0 V16.03.10.20 allows remote attackers to cause denial of service and possibly code execution by sending a post request with a crafted payload (field `serviceName`) to /goform/AdvSetMacMtuWan."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-17T19:13:55.920Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/johnathanhuutri/CVEReport/tree/master/CVE-2025-67073"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-67073",
    "datePublished": "2025-12-17T00:00:00.000Z",
    "dateReserved": "2025-12-08T00:00:00.000Z",
    "dateUpdated": "2025-12-17T19:28:39.953Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-67074 (GCVE-0-2025-67074)

Vulnerability from cvelistv5 – Published: 2025-12-17 00:00 – Updated: 2025-12-18 18:52
VLAI?
Summary
A Buffer overflow vulnerability in function fromAdvSetMacMtuWan of bin httpd in Tenda AC10V4.0 V16.03.10.20 allows remote attackers to cause denial of service and possibly code execution by sending a post request with a crafted payload (field `serverName`) to /goform/AdvSetMacMtuWan.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-67074",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-18T16:13:14.832272Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-120",
                "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-18T18:52:29.602Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/johnathanhuutri/CVEReport/tree/master/CVE-2025-67074"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A Buffer overflow vulnerability in function fromAdvSetMacMtuWan of bin httpd in Tenda AC10V4.0 V16.03.10.20 allows remote attackers to cause denial of service and possibly code execution by sending a post request with a crafted payload (field `serverName`) to /goform/AdvSetMacMtuWan."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-17T19:17:31.870Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/johnathanhuutri/CVEReport/tree/master/CVE-2025-67074"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-67074",
    "datePublished": "2025-12-17T00:00:00.000Z",
    "dateReserved": "2025-12-08T00:00:00.000Z",
    "dateUpdated": "2025-12-18T18:52:29.602Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-12622 (GCVE-0-2025-12622)

Vulnerability from cvelistv5 – Published: 2025-11-03 07:32 – Updated: 2026-02-24 06:23
VLAI?
Title
Tenda AC10 SysRunCmd formSysRunCmd buffer overflow
Summary
A vulnerability was determined in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function formSysRunCmd of the file /goform/SysRunCmd. This manipulation of the argument getui causes buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10 Affected: 16.03.10.13
    cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
1935648903 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12622",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-03T16:06:43.662517Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-03T16:06:54.102Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.10.13"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "1935648903 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was determined in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function formSysRunCmd of the file /goform/SysRunCmd. This manipulation of the argument getui causes buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-24T06:23:57.662Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-330914 | Tenda AC10 SysRunCmd formSysRunCmd buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.330914"
        },
        {
          "name": "VDB-330914 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.330914"
        },
        {
          "name": "Submit #678889 | tenda AC10V4.0 V16.03.10.13 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.678889"
        },
        {
          "tags": [
            "broken-link"
          ],
          "url": "https://www.yuque.com/ba1ma0-an29k/nnxoap/rg8eug0zk8ep3zne?singleDoc"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://pan.baidu.com/s/1Jl1zy5niigg1XYm8ZCh_Lg"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-11-02T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-11-02T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-11-03T10:29:11.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 SysRunCmd formSysRunCmd buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-12622",
    "datePublished": "2025-11-03T07:32:13.624Z",
    "dateReserved": "2025-11-02T17:42:29.275Z",
    "dateUpdated": "2026-02-24T06:23:57.662Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-57217 (GCVE-0-2025-57217)

Vulnerability from cvelistv5 – Published: 2025-08-28 00:00 – Updated: 2025-08-28 20:08
VLAI?
Summary
Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the Password parameter in the function R7WebsSecurityHandler.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-57217",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-28T20:08:13.498941Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-28T20:08:44.818Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the Password parameter in the function R7WebsSecurityHandler."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-28T17:25:54.467Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://plaid-knot-11b.notion.site/Stack-Buffer-Overflow-in-login-Auth-via-Password-parameter-Remote-attacker-can-execute-arbitrary-c-23fb3e9cce32800ba969f8b3a9f80bda?source=copy_link"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-57217",
    "datePublished": "2025-08-28T00:00:00.000Z",
    "dateReserved": "2025-08-17T00:00:00.000Z",
    "dateUpdated": "2025-08-28T20:08:44.818Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-57215 (GCVE-0-2025-57215)

Vulnerability from cvelistv5 – Published: 2025-08-28 00:00 – Updated: 2025-08-28 20:17
VLAI?
Summary
Tenda AC10 v4.0 firmware v16.03.10.20 was discovered to contain a stack overflow via the function get_parentControl_list_Info.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-57215",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-28T20:17:18.227778Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-28T20:17:48.826Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC10 v4.0 firmware v16.03.10.20 was discovered to contain a stack overflow via the function get_parentControl_list_Info."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-28T18:55:34.614Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.tenda.com.cn"
        },
        {
          "url": "https://plaid-knot-11b.notion.site/Heap-based-Buffer-Overflow-in-function-get_parentControl_list_Info-via-deviceId-parameter-Remote-at-23eb3e9cce328014a639f619bc14ed90"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-57215",
    "datePublished": "2025-08-28T00:00:00.000Z",
    "dateReserved": "2025-08-17T00:00:00.000Z",
    "dateUpdated": "2025-08-28T20:17:48.826Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-57219 (GCVE-0-2025-57219)

Vulnerability from cvelistv5 – Published: 2025-08-28 00:00 – Updated: 2025-08-28 19:56
VLAI?
Summary
Incorrect access control in the endpoint /goform/ate of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 allows attackers to escalate privileges or access sensitive components via a crafted request.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-57219",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-28T19:56:16.023454Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-284",
                "description": "CWE-284 Improper Access Control",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-28T19:56:47.808Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Incorrect access control in the endpoint /goform/ate of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 allows attackers to escalate privileges or access sensitive components via a crafted request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-28T18:49:07.173Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://plaid-knot-11b.notion.site/Unauthenticated-Remote-Access-to-ate-Debug-Interface-via-Improper-Access-Controls-in-Tenda-AC10-V4-23fb3e9cce328050a479e44a8c217a72?source=copy_link"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-57219",
    "datePublished": "2025-08-28T00:00:00.000Z",
    "dateReserved": "2025-08-17T00:00:00.000Z",
    "dateUpdated": "2025-08-28T19:56:47.808Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-57220 (GCVE-0-2025-57220)

Vulnerability from cvelistv5 – Published: 2025-08-28 00:00 – Updated: 2025-08-28 20:20
VLAI?
Summary
An input validation flaw in the 'ate' service of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 to escalate privileges to root via a crafted UDP packet.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-57220",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-28T20:19:48.800346Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-20",
                "description": "CWE-20 Improper Input Validation",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-28T20:20:21.748Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An input validation flaw in the \u0027ate\u0027 service of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 to escalate privileges to root via a crafted UDP packet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-28T18:51:44.373Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://plaid-knot-11b.notion.site/Unauthenticated-Remote-Root-Shell-via-Input-Validation-Flaw-in-ate-Service-on-Tenda-AC10-V4-0-23fb3e9cce32804d93aad7e79a82a7aa?source=copy_link"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-57220",
    "datePublished": "2025-08-28T00:00:00.000Z",
    "dateReserved": "2025-08-17T00:00:00.000Z",
    "dateUpdated": "2025-08-28T20:20:21.748Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-57218 (GCVE-0-2025-57218)

Vulnerability from cvelistv5 – Published: 2025-08-28 00:00 – Updated: 2025-08-28 20:10
VLAI?
Summary
Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the security_5g parameter in the function sub_46284C.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-57218",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-28T20:09:29.923911Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-28T20:10:03.408Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the security_5g parameter in the function sub_46284C."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-28T17:29:33.082Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://plaid-knot-11b.notion.site/Stack-Buffer-Overflow-in-goform-WifiBasicSet-via-Password-parameter-Remote-attacker-can-execute-ar-23fb3e9cce32807c883fc1b233e09eca?source=copy_link"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-57218",
    "datePublished": "2025-08-28T00:00:00.000Z",
    "dateReserved": "2025-08-17T00:00:00.000Z",
    "dateUpdated": "2025-08-28T20:10:03.408Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-9309 (GCVE-0-2025-9309)

Vulnerability from cvelistv5 – Published: 2025-08-21 16:32 – Updated: 2025-08-21 17:31
VLAI?
Title
Tenda AC10 MD5 Hash shadow hard-coded credentials
Summary
A vulnerability was found in Tenda AC10 16.03.10.13. Affected is an unknown function of the file /etc_ro/shadow of the component MD5 Hash Handler. Performing manipulation results in hard-coded credentials. The attack needs to be approached locally. A high degree of complexity is needed for the attack. The exploitability is told to be difficult. The exploit has been made public and could be used.
CWE
  • CWE-798 - Hard-coded Credentials
  • CWE-259 - Use of Hard-coded Password
Assigner
Impacted products
Vendor Product Version
Tenda AC10 Affected: 16.03.10.13
Create a notification for this product.
Credits
lxyilu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9309",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-21T17:22:51.502547Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-21T17:31:37.142Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC10/V4.0si_V16.03.10.13.md#steps-to-reproduce"
          },
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC10/V4.0si_V16.03.10.13.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "MD5 Hash Handler"
          ],
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.10.13"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "lxyilu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC10 16.03.10.13. Affected is an unknown function of the file /etc_ro/shadow of the component MD5 Hash Handler. Performing manipulation results in hard-coded credentials. The attack needs to be approached locally. A high degree of complexity is needed for the attack. The exploitability is told to be difficult. The exploit has been made public and could be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC10 16.03.10.13 wurde eine Schwachstelle gefunden. Es geht um eine nicht n\u00e4her bekannte Funktion der Datei /etc_ro/shadow der Komponente MD5 Hash Handler. Mittels Manipulieren mit unbekannten Daten kann eine hard-coded credentials-Schwachstelle ausgenutzt werden. Der Angriff muss lokal angegangen werden. Die Komplexit\u00e4t eines Angriffs ist eher hoch. Die Ausf\u00fchrung eines Exploits gilt als schwer. Die Ausnutzung wurde ver\u00f6ffentlicht und kann verwendet werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 2,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 2.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 2.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 1,
            "vectorString": "AV:L/AC:H/Au:S/C:P/I:N/A:N/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-259",
              "description": "Use of Hard-coded Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-21T16:32:08.672Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-320914 | Tenda AC10 MD5 Hash shadow hard-coded credentials",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/?id.320914"
        },
        {
          "name": "VDB-320914 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.320914"
        },
        {
          "name": "Submit #633585 | Tenda Tenda Wi-Fi 5 Router AC10 AC10V4.0si_V16.03.10.13 Hard-coded Credentials",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.633585"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC10/V4.0si_V16.03.10.13.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC10/V4.0si_V16.03.10.13.md#steps-to-reproduce"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-08-21T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-08-21T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-08-21T08:11:48.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 MD5 Hash shadow hard-coded credentials"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-9309",
    "datePublished": "2025-08-21T16:32:08.672Z",
    "dateReserved": "2025-08-21T06:06:44.302Z",
    "dateUpdated": "2025-08-21T17:31:37.142Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-8178 (GCVE-0-2025-8178)

Vulnerability from cvelistv5 – Published: 2025-07-26 04:32 – Updated: 2025-07-28 16:06
VLAI?
Title
Tenda AC10 RequestsProcessLaid heap-based overflow
Summary
A vulnerability classified as critical has been found in Tenda AC10 16.03.10.13. Affected is an unknown function of the file /goform/RequestsProcessLaid. The manipulation of the argument device1D leads to heap-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
URL Tags
https://vuldb.com/?id.317592 vdb-entrytechnical-description
https://vuldb.com/?ctiid.317592 signaturepermissions-required
https://vuldb.com/?submit.621811 third-party-advisory
https://www.yuque.com/ba1ma0-an29k/nnxoap/qkixf55… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC10 Affected: 16.03.10.13
Create a notification for this product.
Credits
Xuhsy (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-8178",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-28T16:06:11.336644Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-28T16:06:16.879Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.10.13"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Xuhsy (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Tenda AC10 16.03.10.13. Affected is an unknown function of the file /goform/RequestsProcessLaid. The manipulation of the argument device1D leads to heap-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda AC10 16.03.10.13 entdeckt. Es geht dabei um eine nicht klar definierte Funktion der Datei /goform/RequestsProcessLaid. Dank der Manipulation des Arguments device1D mit unbekannten Daten kann eine heap-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-26T04:32:10.022Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-317592 | Tenda AC10 RequestsProcessLaid heap-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.317592"
        },
        {
          "name": "VDB-317592 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.317592"
        },
        {
          "name": "Submit #621811 | Tenda AC10  V16.03.10.13 Heap overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.621811"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://www.yuque.com/ba1ma0-an29k/nnxoap/qkixf5578145igdt"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-07-25T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-07-25T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-07-25T10:19:20.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 RequestsProcessLaid heap-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-8178",
    "datePublished": "2025-07-26T04:32:10.022Z",
    "dateReserved": "2025-07-25T08:14:09.849Z",
    "dateUpdated": "2025-07-28T16:06:16.879Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-5629 (GCVE-0-2025-5629)

Vulnerability from cvelistv5 – Published: 2025-06-05 02:00 – Updated: 2025-06-05 14:09
VLAI?
Title
Tenda AC10 HTTP SetPptpServerCfg formSetPPTPServer buffer overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda AC10 up to 15.03.06.47. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg of the component HTTP Handler. The manipulation of the argument startIp/endIp leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
URL Tags
https://vuldb.com/?id.311115 vdb-entrytechnical-description
https://vuldb.com/?ctiid.311115 signaturepermissions-required
https://vuldb.com/?submit.589424 third-party-advisory
https://github.com/pfwqdxwdd/cve/blob/main/4.md exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC10 Affected: 15.03.06.0
Affected: 15.03.06.1
Affected: 15.03.06.2
Affected: 15.03.06.3
Affected: 15.03.06.4
Affected: 15.03.06.5
Affected: 15.03.06.6
Affected: 15.03.06.7
Affected: 15.03.06.8
Affected: 15.03.06.9
Affected: 15.03.06.10
Affected: 15.03.06.11
Affected: 15.03.06.12
Affected: 15.03.06.13
Affected: 15.03.06.14
Affected: 15.03.06.15
Affected: 15.03.06.16
Affected: 15.03.06.17
Affected: 15.03.06.18
Affected: 15.03.06.19
Affected: 15.03.06.20
Affected: 15.03.06.21
Affected: 15.03.06.22
Affected: 15.03.06.23
Affected: 15.03.06.24
Affected: 15.03.06.25
Affected: 15.03.06.26
Affected: 15.03.06.27
Affected: 15.03.06.28
Affected: 15.03.06.29
Affected: 15.03.06.30
Affected: 15.03.06.31
Affected: 15.03.06.32
Affected: 15.03.06.33
Affected: 15.03.06.34
Affected: 15.03.06.35
Affected: 15.03.06.36
Affected: 15.03.06.37
Affected: 15.03.06.38
Affected: 15.03.06.39
Affected: 15.03.06.40
Affected: 15.03.06.41
Affected: 15.03.06.42
Affected: 15.03.06.43
Affected: 15.03.06.44
Affected: 15.03.06.45
Affected: 15.03.06.46
Affected: 15.03.06.47
Create a notification for this product.
Credits
pfwqdxwdd (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-5629",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-05T13:56:33.195981Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-05T14:09:40.736Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "broken-link"
            ],
            "url": "https://github.com/pfwqdxwdd/cve/blob/main/4.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "HTTP Handler"
          ],
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.0"
            },
            {
              "status": "affected",
              "version": "15.03.06.1"
            },
            {
              "status": "affected",
              "version": "15.03.06.2"
            },
            {
              "status": "affected",
              "version": "15.03.06.3"
            },
            {
              "status": "affected",
              "version": "15.03.06.4"
            },
            {
              "status": "affected",
              "version": "15.03.06.5"
            },
            {
              "status": "affected",
              "version": "15.03.06.6"
            },
            {
              "status": "affected",
              "version": "15.03.06.7"
            },
            {
              "status": "affected",
              "version": "15.03.06.8"
            },
            {
              "status": "affected",
              "version": "15.03.06.9"
            },
            {
              "status": "affected",
              "version": "15.03.06.10"
            },
            {
              "status": "affected",
              "version": "15.03.06.11"
            },
            {
              "status": "affected",
              "version": "15.03.06.12"
            },
            {
              "status": "affected",
              "version": "15.03.06.13"
            },
            {
              "status": "affected",
              "version": "15.03.06.14"
            },
            {
              "status": "affected",
              "version": "15.03.06.15"
            },
            {
              "status": "affected",
              "version": "15.03.06.16"
            },
            {
              "status": "affected",
              "version": "15.03.06.17"
            },
            {
              "status": "affected",
              "version": "15.03.06.18"
            },
            {
              "status": "affected",
              "version": "15.03.06.19"
            },
            {
              "status": "affected",
              "version": "15.03.06.20"
            },
            {
              "status": "affected",
              "version": "15.03.06.21"
            },
            {
              "status": "affected",
              "version": "15.03.06.22"
            },
            {
              "status": "affected",
              "version": "15.03.06.23"
            },
            {
              "status": "affected",
              "version": "15.03.06.24"
            },
            {
              "status": "affected",
              "version": "15.03.06.25"
            },
            {
              "status": "affected",
              "version": "15.03.06.26"
            },
            {
              "status": "affected",
              "version": "15.03.06.27"
            },
            {
              "status": "affected",
              "version": "15.03.06.28"
            },
            {
              "status": "affected",
              "version": "15.03.06.29"
            },
            {
              "status": "affected",
              "version": "15.03.06.30"
            },
            {
              "status": "affected",
              "version": "15.03.06.31"
            },
            {
              "status": "affected",
              "version": "15.03.06.32"
            },
            {
              "status": "affected",
              "version": "15.03.06.33"
            },
            {
              "status": "affected",
              "version": "15.03.06.34"
            },
            {
              "status": "affected",
              "version": "15.03.06.35"
            },
            {
              "status": "affected",
              "version": "15.03.06.36"
            },
            {
              "status": "affected",
              "version": "15.03.06.37"
            },
            {
              "status": "affected",
              "version": "15.03.06.38"
            },
            {
              "status": "affected",
              "version": "15.03.06.39"
            },
            {
              "status": "affected",
              "version": "15.03.06.40"
            },
            {
              "status": "affected",
              "version": "15.03.06.41"
            },
            {
              "status": "affected",
              "version": "15.03.06.42"
            },
            {
              "status": "affected",
              "version": "15.03.06.43"
            },
            {
              "status": "affected",
              "version": "15.03.06.44"
            },
            {
              "status": "affected",
              "version": "15.03.06.45"
            },
            {
              "status": "affected",
              "version": "15.03.06.46"
            },
            {
              "status": "affected",
              "version": "15.03.06.47"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "pfwqdxwdd (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, was found in Tenda AC10 up to 15.03.06.47. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg of the component HTTP Handler. The manipulation of the argument startIp/endIp leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda AC10 bis 15.03.06.47 gefunden. Es betrifft die Funktion formSetPPTPServer der Datei /goform/SetPptpServerCfg der Komponente HTTP Handler. Mit der Manipulation des Arguments startIp/endIp mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-05T02:00:21.084Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-311115 | Tenda AC10 HTTP SetPptpServerCfg formSetPPTPServer buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.311115"
        },
        {
          "name": "VDB-311115 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.311115"
        },
        {
          "name": "Submit #589424 | Tenda AC10 \u003c=V15.03.06.47 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.589424"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/pfwqdxwdd/cve/blob/main/4.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-06-04T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-06-04T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-06-04T13:25:00.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 HTTP SetPptpServerCfg formSetPPTPServer buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-5629",
    "datePublished": "2025-06-05T02:00:21.084Z",
    "dateReserved": "2025-06-04T11:19:57.609Z",
    "dateUpdated": "2025-06-05T14:09:40.736Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}