Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

15 vulnerabilities found for a301 by tenda

VAR-202404-2116

Vulnerability from variot - Updated: 2025-05-30 23:24

A vulnerability was found in Tenda A301 15.13.08.12_multi_TDE01. It has been rated as critical. This issue affects the function formAddMacfilterRule of the file /goform/setBlackRule. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262223. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of A301 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. No detailed vulnerability details are provided at present

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202404-2116",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "a301",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.08.12"
      },
      {
        "model": "a301",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "a301  firmware  15.03.08.12"
      },
      {
        "model": "a301",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "a301",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "a301 15.13.08.12 multi tde01",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23302"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024376"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-4291"
      }
    ]
  },
  "cve": "CVE-2024-4291",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2024-4291",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "OTHER",
            "availabilityImpact": "Complete",
            "baseScore": 9.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "JVNDB-2024-024376",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2024-23302",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2024-4291",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "OTHER",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2024-024376",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-4291",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2024-4291",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2024-024376",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-23302",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23302"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024376"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-4291"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-4291"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was found in Tenda A301 15.13.08.12_multi_TDE01. It has been rated as critical. This issue affects the function formAddMacfilterRule of the file /goform/setBlackRule. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262223. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of A301 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. No detailed vulnerability details are provided at present",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-4291"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024376"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-23302"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-4291",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "262223",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024376",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-23302",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23302"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024376"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-4291"
      }
    ]
  },
  "id": "VAR-202404-2116",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23302"
      }
    ],
    "trust": 1.13333336
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23302"
      }
    ]
  },
  "last_update_date": "2025-05-30T23:24:34.388000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      },
      {
        "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024376"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-4291"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.262223"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.320672"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-4291"
      },
      {
        "trust": 1.0,
        "url": "https://github.com/l1ziang/vulnerability/blob/main/formaddmacfilterrule.md"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.262223"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23302"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024376"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-4291"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23302"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024376"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-4291"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-05-17T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-23302"
      },
      {
        "date": "2025-05-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-024376"
      },
      {
        "date": "2024-04-27T20:15:07.170000",
        "db": "NVD",
        "id": "CVE-2024-4291"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-05-20T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-23302"
      },
      {
        "date": "2025-05-29T07:38:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-024376"
      },
      {
        "date": "2025-05-28T13:47:06.687000",
        "db": "NVD",
        "id": "CVE-2024-4291"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0A301\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024376"
      }
    ],
    "trust": 0.8
  }
}

VAR-202408-0167

Vulnerability from variot - Updated: 2025-05-28 23:22

A vulnerability classified as critical has been found in Tenda A301 15.13.08.12. This affects the function formWifiBasicSet of the file /goform/WifiBasicSet. The manipulation of the argument security leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of a301 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda A301 is a wireless signal extender from China's Tenda Company. No detailed vulnerability details are currently available

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202408-0167",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "a301",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.13.08.12"
      },
      {
        "model": "a301",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "a301  firmware  15.13.08.12"
      },
      {
        "model": "a301",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "a301",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "a301",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "15.13.08.12"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10777"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-005048"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-7581"
      }
    ]
  },
  "cve": "CVE-2024-7581",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2024-7581",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "OTHER",
            "availabilityImpact": "Complete",
            "baseScore": 9.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "JVNDB-2024-005048",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2025-10777",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2024-7581",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2024-7581",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2024-005048",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-7581",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2024-7581",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2024-005048",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-10777",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10777"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-005048"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-7581"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-7581"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability classified as critical has been found in Tenda A301 15.13.08.12. This affects the function formWifiBasicSet of the file /goform/WifiBasicSet. The manipulation of the argument security leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of a301 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda A301 is a wireless signal extender from China\u0027s Tenda Company. No detailed vulnerability details are currently available",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-7581"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-005048"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-10777"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-7581",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "273861",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-005048",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-10777",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10777"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-005048"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-7581"
      }
    ]
  },
  "id": "VAR-202408-0167",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10777"
      }
    ],
    "trust": 1.13333336
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10777"
      }
    ]
  },
  "last_update_date": "2025-05-28T23:22:19.824000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-005048"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-7581"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/beacox/iot_vuln/tree/main/tenda/a301/wifibasicset_bof"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.273861"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.382745"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-7581"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.273861"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10777"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-005048"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-7581"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10777"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-005048"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-7581"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-05-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-10777"
      },
      {
        "date": "2024-08-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-005048"
      },
      {
        "date": "2024-08-07T15:15:56.787000",
        "db": "NVD",
        "id": "CVE-2024-7581"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-05-27T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-10777"
      },
      {
        "date": "2024-08-09T03:10:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-005048"
      },
      {
        "date": "2024-08-07T19:59:00.853000",
        "db": "NVD",
        "id": "CVE-2024-7581"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0a301\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-005048"
      }
    ],
    "trust": 0.8
  }
}

VAR-202406-0720

Vulnerability from variot - Updated: 2024-11-07 22:27

A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of a301 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202406-0720",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "a301",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.13.08.12"
      },
      {
        "model": "a301",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "a301",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "a301  firmware  15.13.08.12"
      },
      {
        "model": "a301",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011881"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6189"
      }
    ]
  },
  "cve": "CVE-2024-6189",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2024-6189",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "OTHER",
            "availabilityImpact": "Complete",
            "baseScore": 9.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "JVNDB-2024-011881",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2024-6189",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2024-011881",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-6189",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2024-6189",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2024-011881",
            "trust": 0.8,
            "value": "High"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011881"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6189"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6189"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of a301 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-6189"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011881"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-6189",
        "trust": 2.6
      },
      {
        "db": "VULDB",
        "id": "269160",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011881",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011881"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6189"
      }
    ]
  },
  "id": "VAR-202406-0720",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.53333336
  },
  "last_update_date": "2024-11-07T22:27:54.540000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      },
      {
        "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011881"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6189"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://military-hail-377.notion.site/tenda-a301v2-0-stack-overflow-c95f23f03b2b4eb5b8ffd3912e9982fd"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.269160"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.355264"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.269160"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-6189"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011881"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6189"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011881"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6189"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-11-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-011881"
      },
      {
        "date": "2024-06-20T14:15:12.370000",
        "db": "NVD",
        "id": "CVE-2024-6189"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-11-05T04:54:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-011881"
      },
      {
        "date": "2024-11-01T14:19:17.187000",
        "db": "NVD",
        "id": "CVE-2024-6189"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0a301\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011881"
      }
    ],
    "trust": 0.8
  }
}

VAR-202406-2832

Vulnerability from variot - Updated: 2024-09-03 23:22

A vulnerability classified as critical was found in Tenda A301 15.13.08.12. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-269947. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of a301 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda A301 is a wireless signal extender from China's Tenda Company. The vulnerability is caused by the /goform/SetOnlineDevName parameter devName failing to correctly verify the length of the input data. A remote attacker can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202406-2832",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "a301",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.13.08.12"
      },
      {
        "model": "a301",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "a301",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "a301",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "a301  firmware  15.13.08.12"
      },
      {
        "model": "a301",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "15.13.08.12"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-31395"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-007058"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6402"
      }
    ]
  },
  "cve": "CVE-2024-6402",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2024-6402",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "OTHER",
            "availabilityImpact": "Complete",
            "baseScore": 6.8,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "JVNDB-2024-007058",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2024-31395",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2024-6402",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2024-6402",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2024-007058",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-6402",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2024-6402",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2024-007058",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-31395",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-31395"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-007058"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6402"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6402"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability classified as critical was found in Tenda A301 15.13.08.12. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-269947. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of a301 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda A301 is a wireless signal extender from China\u0027s Tenda Company. The vulnerability is caused by the /goform/SetOnlineDevName parameter devName failing to correctly verify the length of the input data. A remote attacker can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-6402"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-007058"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-31395"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-6402",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "269947",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-007058",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-31395",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-31395"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-007058"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6402"
      }
    ]
  },
  "id": "VAR-202406-2832",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-31395"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-31395"
      }
    ]
  },
  "last_update_date": "2024-09-03T23:22:05.770000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-007058"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6402"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/general-offensive/iot_vuldb/blob/main/tenda/a301/formsetdevicename_devname.md"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.269947"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.360696"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-6402"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.269947"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-31395"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-007058"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6402"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-31395"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-007058"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6402"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-07-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-31395"
      },
      {
        "date": "2024-09-02T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-007058"
      },
      {
        "date": "2024-06-28T17:15:03.810000",
        "db": "NVD",
        "id": "CVE-2024-6402"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-07-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-31395"
      },
      {
        "date": "2024-09-02T07:18:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-007058"
      },
      {
        "date": "2024-08-30T21:08:54.327000",
        "db": "NVD",
        "id": "CVE-2024-6402"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0a301\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-007058"
      }
    ],
    "trust": 0.8
  }
}

VAR-202406-2871

Vulnerability from variot - Updated: 2024-09-03 23:15

A vulnerability, which was classified as critical, has been found in Tenda A301 15.13.08.12. Affected by this issue is the function formWifiBasicSet of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269948. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of a301 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda A301 is a wireless signal extender from China's Tenda company.

There is a security vulnerability in Tenda A301 version 15.13.08.12, which can be exploited by remote attackers to execute arbitrary code on the system or cause a denial of service attack

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202406-2871",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "a301",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.13.08.12"
      },
      {
        "model": "a301",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "a301",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "a301",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "a301  firmware  15.13.08.12"
      },
      {
        "model": "a301",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "15.13.08.12"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-31386"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-006983"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6403"
      }
    ]
  },
  "cve": "CVE-2024-6403",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2024-6403",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "OTHER",
            "availabilityImpact": "Complete",
            "baseScore": 6.8,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "JVNDB-2024-006983",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2024-31386",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2024-6403",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2024-6403",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2024-006983",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-6403",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2024-6403",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2024-006983",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-31386",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-31386"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-006983"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6403"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6403"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability, which was classified as critical, has been found in Tenda A301 15.13.08.12. Affected by this issue is the function formWifiBasicSet of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269948. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of a301 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda A301 is a wireless signal extender from China\u0027s Tenda company. \n\nThere is a security vulnerability in Tenda A301 version 15.13.08.12, which can be exploited by remote attackers to execute arbitrary code on the system or cause a denial of service attack",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-6403"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-006983"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-31386"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-6403",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "269948",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-006983",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-31386",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-31386"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-006983"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6403"
      }
    ]
  },
  "id": "VAR-202406-2871",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-31386"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-31386"
      }
    ]
  },
  "last_update_date": "2024-09-03T23:15:40.820000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-006983"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6403"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/general-offensive/iot_vuldb/blob/main/tenda/a301/formsetdevicename_devname.md"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.269948"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.360752"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-6403"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.269948"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-31386"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-006983"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6403"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-31386"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-006983"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-6403"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-07-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-31386"
      },
      {
        "date": "2024-09-02T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-006983"
      },
      {
        "date": "2024-06-28T17:15:04.140000",
        "db": "NVD",
        "id": "CVE-2024-6403"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-07-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-31386"
      },
      {
        "date": "2024-09-02T01:44:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-006983"
      },
      {
        "date": "2024-08-30T21:08:04.557000",
        "db": "NVD",
        "id": "CVE-2024-6403"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0a301\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-006983"
      }
    ],
    "trust": 0.8
  }
}

CVE-2024-7581 (GCVE-0-2024-7581)

Vulnerability from nvd – Published: 2024-08-07 15:00 – Updated: 2024-08-07 15:40
VLAI?
Title
Tenda A301 WifiBasicSet formWifiBasicSet stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda A301 15.13.08.12. This affects the function formWifiBasicSet of the file /goform/WifiBasicSet. The manipulation of the argument security leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda A301 Affected: 15.13.08.12
Create a notification for this product.
Credits
BeaCox (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:a301_firmware:15.13.08.12:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "a301_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.13.08.12"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7581",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-07T15:40:05.246414Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-07T15:40:44.206Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "A301",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.13.08.12"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "BeaCox (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Tenda A301 15.13.08.12. This affects the function formWifiBasicSet of the file /goform/WifiBasicSet. The manipulation of the argument security leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda A301 15.13.08.12 entdeckt. Sie wurde als kritisch eingestuft. Hiervon betroffen ist die Funktion formWifiBasicSet der Datei /goform/WifiBasicSet. Mittels dem Manipulieren des Arguments security mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-07T15:00:09.496Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-273861 | Tenda A301 WifiBasicSet formWifiBasicSet stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.273861"
        },
        {
          "name": "VDB-273861 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.273861"
        },
        {
          "name": "Submit #382745 | Tenda A301 V15.13.08.12 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.382745"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/BeaCox/IoT_vuln/tree/main/tenda/A301/WifiBasicSet_bof"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-08-07T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-08-07T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-08-07T08:57:59.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda A301 WifiBasicSet formWifiBasicSet stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-7581",
    "datePublished": "2024-08-07T15:00:09.496Z",
    "dateReserved": "2024-08-07T06:52:40.823Z",
    "dateUpdated": "2024-08-07T15:40:44.206Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-6403 (GCVE-0-2024-6403)

Vulnerability from nvd – Published: 2024-06-28 17:00 – Updated: 2024-08-01 21:41
VLAI?
Title
Tenda A301 SetOnlineDevName formWifiBasicSet stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda A301 15.13.08.12. Affected by this issue is the function formWifiBasicSet of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269948. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda A301 Affected: 15.13.08.12
Create a notification for this product.
Credits
C9Y_57 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:a301_firmware:15.13.08.12:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "a301_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.13.08.12"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-6403",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-02T19:38:09.935913Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-08T20:33:19.325Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:41:03.307Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-269948 | Tenda A301 SetOnlineDevName formWifiBasicSet stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.269948"
          },
          {
            "name": "VDB-269948 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.269948"
          },
          {
            "name": "Submit #360752 | Tenda A301V2.0 A301V2.0 Firmware V15.13.08.12 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.360752"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "A301",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.13.08.12"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "C9Y_57 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Tenda A301 15.13.08.12. Affected by this issue is the function formWifiBasicSet of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269948. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda A301 15.13.08.12 entdeckt. Betroffen davon ist die Funktion formWifiBasicSet der Datei /goform/SetOnlineDevName. Durch Manipulieren des Arguments devName mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.8,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-28T17:00:07.083Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-269948 | Tenda A301 SetOnlineDevName formWifiBasicSet stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.269948"
        },
        {
          "name": "VDB-269948 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.269948"
        },
        {
          "name": "Submit #360752 | Tenda A301V2.0 A301V2.0 Firmware V15.13.08.12 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.360752"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-06-28T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-06-28T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-06-28T14:19:50.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda A301 SetOnlineDevName formWifiBasicSet stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-6403",
    "datePublished": "2024-06-28T17:00:07.083Z",
    "dateReserved": "2024-06-28T12:14:41.333Z",
    "dateUpdated": "2024-08-01T21:41:03.307Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-6402 (GCVE-0-2024-6402)

Vulnerability from nvd – Published: 2024-06-28 17:00 – Updated: 2024-08-01 21:41
VLAI?
Title
Tenda A301 SetOnlineDevName fromSetWirelessRepeat stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda A301 15.13.08.12. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-269947. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda A301 Affected: 15.13.08.12
Create a notification for this product.
Credits
dexter_zg (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:a301_firmware:15.13.08.12:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "a301_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.13.08.12"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-6402",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-29T19:29:21.840575Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-29T19:30:25.108Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:41:03.185Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-269947 | Tenda A301 SetOnlineDevName fromSetWirelessRepeat stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.269947"
          },
          {
            "name": "VDB-269947 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.269947"
          },
          {
            "name": "Submit #360696 | Tenda A301V2.0 Firmware V15.13.08.12 buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.360696"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "A301",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.13.08.12"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "dexter_zg (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in Tenda A301 15.13.08.12. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-269947. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda A301 15.13.08.12 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion fromSetWirelessRepeat der Datei /goform/SetOnlineDevName. Durch das Manipulieren des Arguments devName mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.8,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-28T17:00:05.443Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-269947 | Tenda A301 SetOnlineDevName fromSetWirelessRepeat stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.269947"
        },
        {
          "name": "VDB-269947 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.269947"
        },
        {
          "name": "Submit #360696 | Tenda A301V2.0 Firmware V15.13.08.12 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.360696"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-06-28T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-06-28T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-06-28T14:19:48.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda A301 SetOnlineDevName fromSetWirelessRepeat stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-6402",
    "datePublished": "2024-06-28T17:00:05.443Z",
    "dateReserved": "2024-06-28T12:14:38.593Z",
    "dateUpdated": "2024-08-01T21:41:03.185Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-6189 (GCVE-0-2024-6189)

Vulnerability from nvd – Published: 2024-06-20 14:00 – Updated: 2024-08-01 21:33
VLAI?
Title
Tenda A301 WifiExtraSet fromSetWirelessRepeat stack-based overflow
Summary
A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda A301 Affected: 15.13.08.12
Create a notification for this product.
Credits
seuilping (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:a301:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "a301",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.13.08.12"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-6189",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-25T15:32:07.042197Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-25T15:40:00.073Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:33:05.173Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-269160 | Tenda A301 WifiExtraSet fromSetWirelessRepeat stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.269160"
          },
          {
            "name": "VDB-269160 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.269160"
          },
          {
            "name": "Submit #355264 | Tenda A301V2.0 Firmware V15.13.08.12 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.355264"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://military-hail-377.notion.site/Tenda-A301V2-0-stack-overflow-c95f23f03b2b4eb5b8ffd3912e9982fd"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "A301",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.13.08.12"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "seuilping (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda A301 15.13.08.12 ausgemacht. Es betrifft die Funktion fromSetWirelessRepeat der Datei /goform/WifiExtraSet. Dank Manipulation des Arguments wpapsk_crypto mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-20T14:00:05.817Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-269160 | Tenda A301 WifiExtraSet fromSetWirelessRepeat stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.269160"
        },
        {
          "name": "VDB-269160 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.269160"
        },
        {
          "name": "Submit #355264 | Tenda A301V2.0 Firmware V15.13.08.12 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.355264"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://military-hail-377.notion.site/Tenda-A301V2-0-stack-overflow-c95f23f03b2b4eb5b8ffd3912e9982fd"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-06-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-06-20T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-06-20T07:44:13.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda A301 WifiExtraSet fromSetWirelessRepeat stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-6189",
    "datePublished": "2024-06-20T14:00:05.817Z",
    "dateReserved": "2024-06-20T05:38:53.981Z",
    "dateUpdated": "2024-08-01T21:33:05.173Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4291 (GCVE-0-2024-4291)

Vulnerability from nvd – Published: 2024-04-27 20:00 – Updated: 2025-08-27 21:26
VLAI?
Title
Tenda A301 setBlackRule formAddMacfilterRule stack-based overflow
Summary
A vulnerability was found in Tenda A301 15.13.08.12_multi_TDE01. It has been rated as critical. This issue affects the function formAddMacfilterRule of the file /goform/setBlackRule. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262223. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda A301 Affected: 15.13.08.12_multi_TDE01
Create a notification for this product.
Credits
L1ziang (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.13.08.12_TDE01"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4291",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-29T14:52:10.389752Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-27T21:26:06.856Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:53.224Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-262223 | Tenda A301 setBlackRule formAddMacfilterRule stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.262223"
          },
          {
            "name": "VDB-262223 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.262223"
          },
          {
            "name": "Submit #320672 | Tenda A301 v2.0 US_A301V2.0RTL_V15.13.08.12_multi_TDE01 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.320672"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/L1ziang/Vulnerability/blob/main/formAddMacfilterRule.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "A301",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.13.08.12_multi_TDE01"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "L1ziang (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda A301 15.13.08.12_multi_TDE01. It has been rated as critical. This issue affects the function formAddMacfilterRule of the file /goform/setBlackRule. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262223. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda A301 15.13.08.12_multi_TDE01 ausgemacht. Sie wurde als kritisch eingestuft. Betroffen davon ist die Funktion formAddMacfilterRule der Datei /goform/setBlackRule. Mittels dem Manipulieren des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-27T20:00:07.538Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-262223 | Tenda A301 setBlackRule formAddMacfilterRule stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.262223"
        },
        {
          "name": "VDB-262223 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.262223"
        },
        {
          "name": "Submit #320672 | Tenda A301 v2.0 US_A301V2.0RTL_V15.13.08.12_multi_TDE01 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.320672"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/L1ziang/Vulnerability/blob/main/formAddMacfilterRule.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-27T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-27T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-27T07:54:19.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda A301 setBlackRule formAddMacfilterRule stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4291",
    "datePublished": "2024-04-27T20:00:07.538Z",
    "dateReserved": "2024-04-27T05:49:08.167Z",
    "dateUpdated": "2025-08-27T21:26:06.856Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-7581 (GCVE-0-2024-7581)

Vulnerability from cvelistv5 – Published: 2024-08-07 15:00 – Updated: 2024-08-07 15:40
VLAI?
Title
Tenda A301 WifiBasicSet formWifiBasicSet stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda A301 15.13.08.12. This affects the function formWifiBasicSet of the file /goform/WifiBasicSet. The manipulation of the argument security leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda A301 Affected: 15.13.08.12
Create a notification for this product.
Credits
BeaCox (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:a301_firmware:15.13.08.12:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "a301_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.13.08.12"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7581",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-07T15:40:05.246414Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-07T15:40:44.206Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "A301",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.13.08.12"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "BeaCox (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Tenda A301 15.13.08.12. This affects the function formWifiBasicSet of the file /goform/WifiBasicSet. The manipulation of the argument security leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda A301 15.13.08.12 entdeckt. Sie wurde als kritisch eingestuft. Hiervon betroffen ist die Funktion formWifiBasicSet der Datei /goform/WifiBasicSet. Mittels dem Manipulieren des Arguments security mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-07T15:00:09.496Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-273861 | Tenda A301 WifiBasicSet formWifiBasicSet stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.273861"
        },
        {
          "name": "VDB-273861 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.273861"
        },
        {
          "name": "Submit #382745 | Tenda A301 V15.13.08.12 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.382745"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/BeaCox/IoT_vuln/tree/main/tenda/A301/WifiBasicSet_bof"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-08-07T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-08-07T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-08-07T08:57:59.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda A301 WifiBasicSet formWifiBasicSet stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-7581",
    "datePublished": "2024-08-07T15:00:09.496Z",
    "dateReserved": "2024-08-07T06:52:40.823Z",
    "dateUpdated": "2024-08-07T15:40:44.206Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-6403 (GCVE-0-2024-6403)

Vulnerability from cvelistv5 – Published: 2024-06-28 17:00 – Updated: 2024-08-01 21:41
VLAI?
Title
Tenda A301 SetOnlineDevName formWifiBasicSet stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda A301 15.13.08.12. Affected by this issue is the function formWifiBasicSet of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269948. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda A301 Affected: 15.13.08.12
Create a notification for this product.
Credits
C9Y_57 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:a301_firmware:15.13.08.12:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "a301_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.13.08.12"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-6403",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-02T19:38:09.935913Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-08T20:33:19.325Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:41:03.307Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-269948 | Tenda A301 SetOnlineDevName formWifiBasicSet stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.269948"
          },
          {
            "name": "VDB-269948 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.269948"
          },
          {
            "name": "Submit #360752 | Tenda A301V2.0 A301V2.0 Firmware V15.13.08.12 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.360752"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "A301",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.13.08.12"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "C9Y_57 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Tenda A301 15.13.08.12. Affected by this issue is the function formWifiBasicSet of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269948. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda A301 15.13.08.12 entdeckt. Betroffen davon ist die Funktion formWifiBasicSet der Datei /goform/SetOnlineDevName. Durch Manipulieren des Arguments devName mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.8,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-28T17:00:07.083Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-269948 | Tenda A301 SetOnlineDevName formWifiBasicSet stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.269948"
        },
        {
          "name": "VDB-269948 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.269948"
        },
        {
          "name": "Submit #360752 | Tenda A301V2.0 A301V2.0 Firmware V15.13.08.12 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.360752"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-06-28T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-06-28T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-06-28T14:19:50.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda A301 SetOnlineDevName formWifiBasicSet stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-6403",
    "datePublished": "2024-06-28T17:00:07.083Z",
    "dateReserved": "2024-06-28T12:14:41.333Z",
    "dateUpdated": "2024-08-01T21:41:03.307Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-6402 (GCVE-0-2024-6402)

Vulnerability from cvelistv5 – Published: 2024-06-28 17:00 – Updated: 2024-08-01 21:41
VLAI?
Title
Tenda A301 SetOnlineDevName fromSetWirelessRepeat stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda A301 15.13.08.12. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-269947. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda A301 Affected: 15.13.08.12
Create a notification for this product.
Credits
dexter_zg (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:a301_firmware:15.13.08.12:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "a301_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.13.08.12"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-6402",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-29T19:29:21.840575Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-29T19:30:25.108Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:41:03.185Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-269947 | Tenda A301 SetOnlineDevName fromSetWirelessRepeat stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.269947"
          },
          {
            "name": "VDB-269947 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.269947"
          },
          {
            "name": "Submit #360696 | Tenda A301V2.0 Firmware V15.13.08.12 buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.360696"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "A301",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.13.08.12"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "dexter_zg (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in Tenda A301 15.13.08.12. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-269947. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda A301 15.13.08.12 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion fromSetWirelessRepeat der Datei /goform/SetOnlineDevName. Durch das Manipulieren des Arguments devName mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.8,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-28T17:00:05.443Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-269947 | Tenda A301 SetOnlineDevName fromSetWirelessRepeat stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.269947"
        },
        {
          "name": "VDB-269947 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.269947"
        },
        {
          "name": "Submit #360696 | Tenda A301V2.0 Firmware V15.13.08.12 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.360696"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-06-28T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-06-28T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-06-28T14:19:48.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda A301 SetOnlineDevName fromSetWirelessRepeat stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-6402",
    "datePublished": "2024-06-28T17:00:05.443Z",
    "dateReserved": "2024-06-28T12:14:38.593Z",
    "dateUpdated": "2024-08-01T21:41:03.185Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-6189 (GCVE-0-2024-6189)

Vulnerability from cvelistv5 – Published: 2024-06-20 14:00 – Updated: 2024-08-01 21:33
VLAI?
Title
Tenda A301 WifiExtraSet fromSetWirelessRepeat stack-based overflow
Summary
A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda A301 Affected: 15.13.08.12
Create a notification for this product.
Credits
seuilping (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:a301:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "a301",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.13.08.12"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-6189",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-25T15:32:07.042197Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-25T15:40:00.073Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:33:05.173Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-269160 | Tenda A301 WifiExtraSet fromSetWirelessRepeat stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.269160"
          },
          {
            "name": "VDB-269160 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.269160"
          },
          {
            "name": "Submit #355264 | Tenda A301V2.0 Firmware V15.13.08.12 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.355264"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://military-hail-377.notion.site/Tenda-A301V2-0-stack-overflow-c95f23f03b2b4eb5b8ffd3912e9982fd"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "A301",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.13.08.12"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "seuilping (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda A301 15.13.08.12 ausgemacht. Es betrifft die Funktion fromSetWirelessRepeat der Datei /goform/WifiExtraSet. Dank Manipulation des Arguments wpapsk_crypto mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-20T14:00:05.817Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-269160 | Tenda A301 WifiExtraSet fromSetWirelessRepeat stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.269160"
        },
        {
          "name": "VDB-269160 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.269160"
        },
        {
          "name": "Submit #355264 | Tenda A301V2.0 Firmware V15.13.08.12 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.355264"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://military-hail-377.notion.site/Tenda-A301V2-0-stack-overflow-c95f23f03b2b4eb5b8ffd3912e9982fd"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-06-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-06-20T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-06-20T07:44:13.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda A301 WifiExtraSet fromSetWirelessRepeat stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-6189",
    "datePublished": "2024-06-20T14:00:05.817Z",
    "dateReserved": "2024-06-20T05:38:53.981Z",
    "dateUpdated": "2024-08-01T21:33:05.173Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4291 (GCVE-0-2024-4291)

Vulnerability from cvelistv5 – Published: 2024-04-27 20:00 – Updated: 2025-08-27 21:26
VLAI?
Title
Tenda A301 setBlackRule formAddMacfilterRule stack-based overflow
Summary
A vulnerability was found in Tenda A301 15.13.08.12_multi_TDE01. It has been rated as critical. This issue affects the function formAddMacfilterRule of the file /goform/setBlackRule. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262223. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda A301 Affected: 15.13.08.12_multi_TDE01
Create a notification for this product.
Credits
L1ziang (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.13.08.12_TDE01"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4291",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-29T14:52:10.389752Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-27T21:26:06.856Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:53.224Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-262223 | Tenda A301 setBlackRule formAddMacfilterRule stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.262223"
          },
          {
            "name": "VDB-262223 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.262223"
          },
          {
            "name": "Submit #320672 | Tenda A301 v2.0 US_A301V2.0RTL_V15.13.08.12_multi_TDE01 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.320672"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/L1ziang/Vulnerability/blob/main/formAddMacfilterRule.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "A301",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.13.08.12_multi_TDE01"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "L1ziang (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda A301 15.13.08.12_multi_TDE01. It has been rated as critical. This issue affects the function formAddMacfilterRule of the file /goform/setBlackRule. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262223. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda A301 15.13.08.12_multi_TDE01 ausgemacht. Sie wurde als kritisch eingestuft. Betroffen davon ist die Funktion formAddMacfilterRule der Datei /goform/setBlackRule. Mittels dem Manipulieren des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-27T20:00:07.538Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-262223 | Tenda A301 setBlackRule formAddMacfilterRule stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.262223"
        },
        {
          "name": "VDB-262223 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.262223"
        },
        {
          "name": "Submit #320672 | Tenda A301 v2.0 US_A301V2.0RTL_V15.13.08.12_multi_TDE01 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.320672"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/L1ziang/Vulnerability/blob/main/formAddMacfilterRule.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-27T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-27T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-27T07:54:19.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda A301 setBlackRule formAddMacfilterRule stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4291",
    "datePublished": "2024-04-27T20:00:07.538Z",
    "dateReserved": "2024-04-27T05:49:08.167Z",
    "dateUpdated": "2025-08-27T21:26:06.856Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}