Search criteria
5 vulnerabilities found for a18 by tenda
VAR-202404-0832
Vulnerability from variot - Updated: 2025-07-20 23:32Tenda A18 v15.03.05.05 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function. Shenzhen Tenda Technology Co.,Ltd. of A18 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda A18 is a dual-band wireless signal extender designed for duplexes, villas and large apartments over 120 square meters. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202404-0832",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "a18",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "15.03.05.05"
},
{
"model": "a18",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "a18",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "a18 firmware 15.03.05.05"
},
{
"model": "a18",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-16319"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021767"
},
{
"db": "NVD",
"id": "CVE-2024-32305"
}
]
},
"cve": "CVE-2024-32305",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2025-16319",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2024-32305",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-021767",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-32305",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-021767",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-16319",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-16319"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021767"
},
{
"db": "NVD",
"id": "CVE-2024-32305"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda A18 v15.03.05.05 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function. Shenzhen Tenda Technology Co.,Ltd. of A18 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda A18 is a dual-band wireless signal extender designed for duplexes, villas and large apartments over 120 square meters. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-32305"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021767"
},
{
"db": "CNVD",
"id": "CNVD-2025-16319"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-32305",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021767",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-16319",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-16319"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021767"
},
{
"db": "NVD",
"id": "CVE-2024-32305"
}
]
},
"id": "VAR-202404-0832",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-16319"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-16319"
}
]
},
"last_update_date": "2025-07-20T23:32:25.875000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda A18 Buffer Overflow Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/710296"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-16319"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-021767"
},
{
"db": "NVD",
"id": "CVE-2024-32305"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac18/fromwizardhandle.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-32305"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-16319"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021767"
},
{
"db": "NVD",
"id": "CVE-2024-32305"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-16319"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021767"
},
{
"db": "NVD",
"id": "CVE-2024-32305"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-07-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-16319"
},
{
"date": "2025-04-10T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-021767"
},
{
"date": "2024-04-17T16:15:08.893000",
"db": "NVD",
"id": "CVE-2024-32305"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-07-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-16319"
},
{
"date": "2025-04-10T02:23:00",
"db": "JVNDB",
"id": "JVNDB-2024-021767"
},
{
"date": "2025-04-09T14:20:39.827000",
"db": "NVD",
"id": "CVE-2024-32305"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0A18\u00a0 Stack-based buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-021767"
}
],
"trust": 0.8
}
}
VAR-202401-1112
Vulnerability from variot - Updated: 2025-06-03 23:30Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function. Tenda A18 is an AC1200 dual-band Wi-Fi repeater from China's Tenda Company.
Tenda A18 v15.13.07.09 version has a buffer overflow vulnerability. This vulnerability is caused by the devName parameter in the formSetDeviceName function failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of Service attacks
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202401-1112",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "a18",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.13.07.09"
},
{
"model": "a18",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v15.13.07.09"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-05739"
},
{
"db": "NVD",
"id": "CVE-2023-50585"
}
]
},
"cve": "CVE-2023-50585",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-05739",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-50585",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-50585",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2023-50585",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2024-05739",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-05739"
},
{
"db": "NVD",
"id": "CVE-2023-50585"
},
{
"db": "NVD",
"id": "CVE-2023-50585"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function. Tenda A18 is an AC1200 dual-band Wi-Fi repeater from China\u0027s Tenda Company. \n\r\n\r\nTenda A18 v15.13.07.09 version has a buffer overflow vulnerability. This vulnerability is caused by the devName parameter in the formSetDeviceName function failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of Service attacks",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-50585"
},
{
"db": "CNVD",
"id": "CNVD-2024-05739"
}
],
"trust": 1.44
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-50585",
"trust": 1.6
},
{
"db": "CNVD",
"id": "CNVD-2024-05739",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-05739"
},
{
"db": "NVD",
"id": "CVE-2023-50585"
}
]
},
"id": "VAR-202401-1112",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-05739"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-05739"
}
]
},
"last_update_date": "2025-06-03T23:30:58.629000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-50585"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.0,
"url": "https://github.com/laphilosophie/iot-vulnerable/blob/main/tenda/a18/formsetdevicename.md"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-50585"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-05739"
},
{
"db": "NVD",
"id": "CVE-2023-50585"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-05739"
},
{
"db": "NVD",
"id": "CVE-2023-50585"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-05739"
},
{
"date": "2024-01-09T09:15:42.430000",
"db": "NVD",
"id": "CVE-2023-50585"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-05739"
},
{
"date": "2025-06-03T15:15:46.043000",
"db": "NVD",
"id": "CVE-2023-50585"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda A18 buffer overflow vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-05739"
}
],
"trust": 0.6
}
}
VAR-202501-3669
Vulnerability from variot - Updated: 2025-03-19 23:14A vulnerability was found in Tenda A18 up to 15.13.07.09. It has been rated as critical. This issue affects the function SetCmdlineRun of the file /goform/SetCmdlineRun of the component HTTP POST Request Handler. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. of A18 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the parameter wpapsk_crypto5g failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system and cause a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202501-3669",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "a18",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.13.07.09"
},
{
"model": "a18",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "a18",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "a18 firmware 15.13.07.09"
},
{
"model": "a18",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "a18",
"scope": "lte",
"trust": 0.6,
"vendor": "tenda",
"version": "\u003c=15.13.07.09"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05264"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002226"
},
{
"db": "NVD",
"id": "CVE-2025-0848"
}
]
},
"cve": "CVE-2025-0848",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 6.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "CVE-2025-0848",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 6.8,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2025-002226",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "CNVD-2025-05264",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"id": "CVE-2025-0848",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2025-0848",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-002226",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2025-0848",
"trust": 1.0,
"value": "High"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2025-0848",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "OTHER",
"id": "JVNDB-2025-002226",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-05264",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05264"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002226"
},
{
"db": "NVD",
"id": "CVE-2025-0848"
},
{
"db": "NVD",
"id": "CVE-2025-0848"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was found in Tenda A18 up to 15.13.07.09. It has been rated as critical. This issue affects the function SetCmdlineRun of the file /goform/SetCmdlineRun of the component HTTP POST Request Handler. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. of A18 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the parameter wpapsk_crypto5g failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system and cause a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-0848"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002226"
},
{
"db": "CNVD",
"id": "CNVD-2025-05264"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-0848",
"trust": 3.2
},
{
"db": "VULDB",
"id": "294011",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002226",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-05264",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05264"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002226"
},
{
"db": "NVD",
"id": "CVE-2025-0848"
}
]
},
"id": "VAR-202501-3669",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05264"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05264"
}
]
},
"last_update_date": "2025-03-19T23:14:22.272000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "CWE-119",
"trust": 1.0
},
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Buffer error (CWE-119) [ others ]",
"trust": 0.8
},
{
"problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
},
{
"problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-002226"
},
{
"db": "NVD",
"id": "CVE-2025-0848"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/alc9700jmo/cve/issues/9"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?id.294011"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.485802"
},
{
"trust": 1.8,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-0848"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.294011"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05264"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002226"
},
{
"db": "NVD",
"id": "CVE-2025-0848"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-05264"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002226"
},
{
"db": "NVD",
"id": "CVE-2025-0848"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-03-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-05264"
},
{
"date": "2025-03-11T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-002226"
},
{
"date": "2025-01-30T02:15:25.597000",
"db": "NVD",
"id": "CVE-2025-0848"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-03-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-05264"
},
{
"date": "2025-03-11T00:59:00",
"db": "JVNDB",
"id": "JVNDB-2025-002226"
},
{
"date": "2025-03-06T13:30:34.893000",
"db": "NVD",
"id": "CVE-2025-0848"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0A18\u00a0 Buffer error vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-002226"
}
],
"trust": 0.8
}
}
CVE-2025-0848 (GCVE-0-2025-0848)
Vulnerability from nvd – Published: 2025-01-30 01:00 – Updated: 2025-01-30 15:12| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-0848",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-30T15:12:54.599269Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-30T15:12:59.662Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"HTTP POST Request Handler"
],
"product": "A18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.13.07.09"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "alc9700 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda A18 up to 15.13.07.09. It has been rated as critical. This issue affects the function SetCmdlineRun of the file /goform/SetCmdlineRun of the component HTTP POST Request Handler. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda A18 bis 15.13.07.09 ausgemacht. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion SetCmdlineRun der Datei /goform/SetCmdlineRun der Komponente HTTP POST Request Handler. Durch die Manipulation des Arguments wpapsk_crypto5g mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.8,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-30T01:00:19.576Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-294011 | Tenda A18 HTTP POST Request SetCmdlineRun stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.294011"
},
{
"name": "VDB-294011 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.294011"
},
{
"name": "Submit #485802 | Tenda Tenda A18 V15.13.07.09 V15.13.07.09 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.485802"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/alc9700jmo/CVE/issues/9"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-01-29T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-01-29T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-01-29T18:14:31.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda A18 HTTP POST Request SetCmdlineRun stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-0848",
"datePublished": "2025-01-30T01:00:19.576Z",
"dateReserved": "2025-01-29T17:09:28.802Z",
"dateUpdated": "2025-01-30T15:12:59.662Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-0848 (GCVE-0-2025-0848)
Vulnerability from cvelistv5 – Published: 2025-01-30 01:00 – Updated: 2025-01-30 15:12| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-0848",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-30T15:12:54.599269Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-30T15:12:59.662Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"HTTP POST Request Handler"
],
"product": "A18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.13.07.09"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "alc9700 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda A18 up to 15.13.07.09. It has been rated as critical. This issue affects the function SetCmdlineRun of the file /goform/SetCmdlineRun of the component HTTP POST Request Handler. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda A18 bis 15.13.07.09 ausgemacht. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion SetCmdlineRun der Datei /goform/SetCmdlineRun der Komponente HTTP POST Request Handler. Durch die Manipulation des Arguments wpapsk_crypto5g mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.8,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-30T01:00:19.576Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-294011 | Tenda A18 HTTP POST Request SetCmdlineRun stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.294011"
},
{
"name": "VDB-294011 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.294011"
},
{
"name": "Submit #485802 | Tenda Tenda A18 V15.13.07.09 V15.13.07.09 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.485802"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/alc9700jmo/CVE/issues/9"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-01-29T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-01-29T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-01-29T18:14:31.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda A18 HTTP POST Request SetCmdlineRun stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-0848",
"datePublished": "2025-01-30T01:00:19.576Z",
"dateReserved": "2025-01-29T17:09:28.802Z",
"dateUpdated": "2025-01-30T15:12:59.662Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}