Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for XDent by CompuGroup Medical

    CVE-2026-112172 (GCVE-0-2026-112172)

    Vulnerability from nvd – Published: 2026-11-09 11:38 – Updated: 2026-11-12 15:49
    VLAI
    Title
    Unauthenticated SQL Execution in XDent/XMedical Synchronization Infrastructure
    Summary
    CGM XDent and XMedical expose PHP synchronization endpoints that allow unauthenticated attackers to manipulate session variables and execute arbitrary SQL queries against backend MySQL databases.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-12 15:48 UTC
    CWE
    • CWE-89 - Improper neutralization of special elements used in an SQL command ('SQL injection')
    Assigner
    ENISA CNA under the ENISA root
    CNA scorecard B 77/100 over 73 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    CompuGroup Medical XDent Affected: 0 , < 4.4.0 (semver)
    Create a notification for this product.
    CompuGroup Medical XMedical Affected: 0 , < 4.4.0 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-112172",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-12T15:48:11.664289Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-12T15:49:33.068Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "XDent",
              "vendor": "CompuGroup Medical",
              "versions": [
                {
                  "lessThan": "4.4.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "XMedical",
              "vendor": "CompuGroup Medical",
              "versions": [
                {
                  "lessThan": "4.4.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Marco Sala"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "CSIRT-IT"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "ApoCert srl"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "CGM XDent and XMedical expose PHP synchronization endpoints that allow unauthenticated attackers to manipulate session variables and execute arbitrary SQL queries against backend MySQL databases."
                }
              ],
              "value": "CGM XDent and XMedical expose PHP synchronization endpoints that allow unauthenticated attackers to manipulate session variables and execute arbitrary SQL queries against backend MySQL databases."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "UNREPORTED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper neutralization of special elements used in an SQL command (\u0027SQL injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-09T11:45:11.226Z",
            "orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
            "shortName": "ENISA"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"
            }
          ],
          "title": "Unauthenticated SQL Execution in XDent/XMedical Synchronization Infrastructure",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "assignerShortName": "ENISA",
        "cveId": "CVE-2026-112172",
        "datePublished": "2026-11-09T11:38:18.744Z",
        "dateReserved": "2026-10-19T08:06:39.208Z",
        "dateUpdated": "2026-11-12T15:49:33.068Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-112172 (GCVE-0-2026-112172)

    Vulnerability from cvelistv5 – Published: 2026-11-09 11:38 – Updated: 2026-11-12 15:49
    VLAI
    Title
    Unauthenticated SQL Execution in XDent/XMedical Synchronization Infrastructure
    Summary
    CGM XDent and XMedical expose PHP synchronization endpoints that allow unauthenticated attackers to manipulate session variables and execute arbitrary SQL queries against backend MySQL databases.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-12 15:48 UTC
    CWE
    • CWE-89 - Improper neutralization of special elements used in an SQL command ('SQL injection')
    Assigner
    ENISA CNA under the ENISA root
    CNA scorecard B 77/100 over 73 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    CompuGroup Medical XDent Affected: 0 , < 4.4.0 (semver)
    Create a notification for this product.
    CompuGroup Medical XMedical Affected: 0 , < 4.4.0 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-112172",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-12T15:48:11.664289Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-12T15:49:33.068Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "XDent",
              "vendor": "CompuGroup Medical",
              "versions": [
                {
                  "lessThan": "4.4.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "XMedical",
              "vendor": "CompuGroup Medical",
              "versions": [
                {
                  "lessThan": "4.4.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Marco Sala"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "CSIRT-IT"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "ApoCert srl"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "CGM XDent and XMedical expose PHP synchronization endpoints that allow unauthenticated attackers to manipulate session variables and execute arbitrary SQL queries against backend MySQL databases."
                }
              ],
              "value": "CGM XDent and XMedical expose PHP synchronization endpoints that allow unauthenticated attackers to manipulate session variables and execute arbitrary SQL queries against backend MySQL databases."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "UNREPORTED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper neutralization of special elements used in an SQL command (\u0027SQL injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-09T11:45:11.226Z",
            "orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
            "shortName": "ENISA"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"
            }
          ],
          "title": "Unauthenticated SQL Execution in XDent/XMedical Synchronization Infrastructure",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "assignerShortName": "ENISA",
        "cveId": "CVE-2026-112172",
        "datePublished": "2026-11-09T11:38:18.744Z",
        "dateReserved": "2026-10-19T08:06:39.208Z",
        "dateUpdated": "2026-11-12T15:49:33.068Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }