Find a vulnerability
Search criteria
6 vulnerabilities found for Wyse Device Agent by Dell
VAR-202202-0978
Vulnerability from variot - Updated: 2024-11-23 22:57Wyse Device Agent version 14.6.1.4 and below contain an Improper Authentication vulnerability. A malicious user could potentially exploit this vulnerability by providing invalid input in order to obtain a connection to WMS server. (DoS) It may be in a state. DELL Dell Wyse Management Suite is a scalable solution for managing and optimizing Wyse endpoints from Dell (DELL). The offering includes Wyse endpoint centralized management, asset tracking and automatic device discovery. A local attacker could exploit this vulnerability to bypass the authentication process
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202202-0978",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wyse device agent",
"scope": "lte",
"trust": 1.0,
"vendor": "dell",
"version": "14.6.1.4"
},
{
"model": "dell wyse device agent",
"scope": "lte",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "14.6.1.4 and earlier"
},
{
"model": "dell wyse device agent",
"scope": null,
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "dell wyse device agent",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-007656"
},
{
"db": "NVD",
"id": "CVE-2022-23156"
}
]
},
"cve": "CVE-2022-23156",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "CVE-2022-23156",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.9,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "VHN-412052",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:L/AC:L/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.8,
"id": "CVE-2022-23156",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "security_alert@emc.com",
"availabilityImpact": "NONE",
"baseScore": 6.0,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.5,
"id": "CVE-2022-23156",
"impactScore": 4.0,
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 6.7,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-23156",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-23156",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "security_alert@emc.com",
"id": "CVE-2022-23156",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2022-23156",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNNVD",
"id": "CNNVD-202202-1595",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-412052",
"trust": 0.1,
"value": "MEDIUM"
},
{
"author": "VULMON",
"id": "CVE-2022-23156",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-412052"
},
{
"db": "VULMON",
"id": "CVE-2022-23156"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007656"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1595"
},
{
"db": "NVD",
"id": "CVE-2022-23156"
},
{
"db": "NVD",
"id": "CVE-2022-23156"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Wyse Device Agent version 14.6.1.4 and below contain an Improper Authentication vulnerability. A malicious user could potentially exploit this vulnerability by providing invalid input in order to obtain a connection to WMS server. (DoS) It may be in a state. DELL Dell Wyse Management Suite is a scalable solution for managing and optimizing Wyse endpoints from Dell (DELL). The offering includes Wyse endpoint centralized management, asset tracking and automatic device discovery. A local attacker could exploit this vulnerability to bypass the authentication process",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-23156"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007656"
},
{
"db": "VULHUB",
"id": "VHN-412052"
},
{
"db": "VULMON",
"id": "CVE-2022-23156"
}
],
"trust": 1.8
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-23156",
"trust": 3.4
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007656",
"trust": 0.8
},
{
"db": "CS-HELP",
"id": "SB2022021803",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1595",
"trust": 0.6
},
{
"db": "CNVD",
"id": "CNVD-2022-42742",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-412052",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2022-23156",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-412052"
},
{
"db": "VULMON",
"id": "CVE-2022-23156"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007656"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1595"
},
{
"db": "NVD",
"id": "CVE-2022-23156"
}
]
},
"id": "VAR-202202-0978",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-412052"
}
],
"trust": 0.01
},
"last_update_date": "2024-11-23T22:57:48.247000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Dell Wyse Management Suite Remediation measures for authorization problem vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=182803"
},
{
"title": "CVE-2022-XXXX",
"trust": 0.1,
"url": "https://github.com/AlphabugX/CVE-2022-23305 "
},
{
"title": "CVE-2022-XXXX",
"trust": 0.1,
"url": "https://github.com/AlphabugX/CVE-2022-RCE "
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2022-23156"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1595"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-287",
"trust": 1.1
},
{
"problemtype": "Inappropriate authentication (CWE-287) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-412052"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007656"
},
{
"db": "NVD",
"id": "CVE-2022-23156"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.6,
"url": "https://www.dell.com/support/kbdoc/000196005"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-23156"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2022021803"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-23156/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/287.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://github.com/alphabugx/cve-2022-23305"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-412052"
},
{
"db": "VULMON",
"id": "CVE-2022-23156"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007656"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1595"
},
{
"db": "NVD",
"id": "CVE-2022-23156"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-412052"
},
{
"db": "VULMON",
"id": "CVE-2022-23156"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007656"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1595"
},
{
"db": "NVD",
"id": "CVE-2022-23156"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-01T00:00:00",
"db": "VULHUB",
"id": "VHN-412052"
},
{
"date": "2022-04-01T00:00:00",
"db": "VULMON",
"id": "CVE-2022-23156"
},
{
"date": "2023-07-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-007656"
},
{
"date": "2022-02-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202202-1595"
},
{
"date": "2022-04-01T20:15:07.947000",
"db": "NVD",
"id": "CVE-2022-23156"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-08T00:00:00",
"db": "VULHUB",
"id": "VHN-412052"
},
{
"date": "2022-04-08T00:00:00",
"db": "VULMON",
"id": "CVE-2022-23156"
},
{
"date": "2023-07-19T08:28:00",
"db": "JVNDB",
"id": "JVNDB-2022-007656"
},
{
"date": "2022-04-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202202-1595"
},
{
"date": "2024-11-21T06:48:05.850000",
"db": "NVD",
"id": "CVE-2022-23156"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202202-1595"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell\u0027s \u00a0Dell\u00a0Wyse\u00a0Device\u00a0Agent\u00a0 Authentication vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-007656"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "authorization issue",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202202-1595"
}
],
"trust": 0.6
}
}
VAR-202202-0977
Vulnerability from variot - Updated: 2024-11-23 22:57Wyse Device Agent version 14.6.1.4 and below contain a sensitive data exposure vulnerability. A authenticated malicious user could potentially exploit this vulnerability in order to view sensitive information from the WMS Server
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202202-0977",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wyse device agent",
"scope": "lte",
"trust": 1.0,
"vendor": "dell",
"version": "14.6.1.4"
},
{
"model": "dell wyse device agent",
"scope": "lte",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "14.6.1.4 and earlier"
},
{
"model": "dell wyse device agent",
"scope": null,
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "dell wyse device agent",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-007655"
},
{
"db": "NVD",
"id": "CVE-2022-23157"
}
]
},
"cve": "CVE-2022-23157",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "CVE-2022-23157",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 1.9,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "VHN-412053",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 0.1,
"vectorString": "AV:L/AC:L/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.8,
"id": "CVE-2022-23157",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.4,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-23157",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-23157",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "security_alert@emc.com",
"id": "CVE-2022-23157",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2022-23157",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNNVD",
"id": "CNNVD-202202-1588",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-412053",
"trust": 0.1,
"value": "LOW"
},
{
"author": "VULMON",
"id": "CVE-2022-23157",
"trust": 0.1,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-412053"
},
{
"db": "VULMON",
"id": "CVE-2022-23157"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007655"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1588"
},
{
"db": "NVD",
"id": "CVE-2022-23157"
},
{
"db": "NVD",
"id": "CVE-2022-23157"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Wyse Device Agent version 14.6.1.4 and below contain a sensitive data exposure vulnerability. A authenticated malicious user could potentially exploit this vulnerability in order to view sensitive information from the WMS Server",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-23157"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007655"
},
{
"db": "VULHUB",
"id": "VHN-412053"
},
{
"db": "VULMON",
"id": "CVE-2022-23157"
}
],
"trust": 1.8
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-23157",
"trust": 3.4
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007655",
"trust": 0.8
},
{
"db": "CS-HELP",
"id": "SB2022021803",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1588",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-412053",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2022-23157",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-412053"
},
{
"db": "VULMON",
"id": "CVE-2022-23157"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007655"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1588"
},
{
"db": "NVD",
"id": "CVE-2022-23157"
}
]
},
"id": "VAR-202202-0977",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-412053"
}
],
"trust": 0.01
},
"last_update_date": "2024-11-23T22:57:48.217000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "WMS Repair measures for information disclosure vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=182797"
},
{
"title": "CVE-2022-XXXX",
"trust": 0.1,
"url": "https://github.com/AlphabugX/CVE-2022-23305 "
},
{
"title": "CVE-2022-XXXX",
"trust": 0.1,
"url": "https://github.com/AlphabugX/CVE-2022-RCE "
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2022-23157"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1588"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-200",
"trust": 1.1
},
{
"problemtype": "information leak (CWE-200) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-412053"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007655"
},
{
"db": "NVD",
"id": "CVE-2022-23157"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.6,
"url": "https://www.dell.com/support/kbdoc/000196005"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-23157"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2022021803"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-23157/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/200.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://github.com/alphabugx/cve-2022-23305"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-412053"
},
{
"db": "VULMON",
"id": "CVE-2022-23157"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007655"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1588"
},
{
"db": "NVD",
"id": "CVE-2022-23157"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-412053"
},
{
"db": "VULMON",
"id": "CVE-2022-23157"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007655"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1588"
},
{
"db": "NVD",
"id": "CVE-2022-23157"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-01T00:00:00",
"db": "VULHUB",
"id": "VHN-412053"
},
{
"date": "2022-04-01T00:00:00",
"db": "VULMON",
"id": "CVE-2022-23157"
},
{
"date": "2023-07-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-007655"
},
{
"date": "2022-02-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202202-1588"
},
{
"date": "2022-04-01T20:15:07.997000",
"db": "NVD",
"id": "CVE-2022-23157"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-08T00:00:00",
"db": "VULHUB",
"id": "VHN-412053"
},
{
"date": "2022-04-08T00:00:00",
"db": "VULMON",
"id": "CVE-2022-23157"
},
{
"date": "2023-07-19T08:28:00",
"db": "JVNDB",
"id": "JVNDB-2022-007655"
},
{
"date": "2022-04-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202202-1588"
},
{
"date": "2024-11-21T06:48:05.977000",
"db": "NVD",
"id": "CVE-2022-23157"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202202-1588"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell\u0027s \u00a0Dell\u00a0Wyse\u00a0Device\u00a0Agent\u00a0 Vulnerability regarding information leakage in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-007655"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202202-1588"
}
],
"trust": 0.6
}
}
VAR-202202-0979
Vulnerability from variot - Updated: 2024-11-23 22:57Wyse Device Agent version 14.6.1.4 and below contain a sensitive data exposure vulnerability. A local authenticated user with standard privilege could potentially exploit this vulnerability and provide incorrect port information and get connected to valid WMS server. An attacker could exploit this vulnerability to gain access to potentially sensitive information
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202202-0979",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wyse device agent",
"scope": "lte",
"trust": 1.0,
"vendor": "dell",
"version": "14.6.1.4"
},
{
"model": "dell wyse device agent",
"scope": "lte",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "14.6.1.4 and earlier"
},
{
"model": "dell wyse device agent",
"scope": null,
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "dell wyse device agent",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-007654"
},
{
"db": "NVD",
"id": "CVE-2022-23158"
}
]
},
"cve": "CVE-2022-23158",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "CVE-2022-23158",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 1.9,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "VHN-412054",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 0.1,
"vectorString": "AV:L/AC:L/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.8,
"id": "CVE-2022-23158",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "security_alert@emc.com",
"availabilityImpact": "NONE",
"baseScore": 6.0,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.5,
"id": "CVE-2022-23158",
"impactScore": 4.0,
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.4,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-23158",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-23158",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "security_alert@emc.com",
"id": "CVE-2022-23158",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2022-23158",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNNVD",
"id": "CNNVD-202202-1592",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-412054",
"trust": 0.1,
"value": "LOW"
},
{
"author": "VULMON",
"id": "CVE-2022-23158",
"trust": 0.1,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-412054"
},
{
"db": "VULMON",
"id": "CVE-2022-23158"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007654"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1592"
},
{
"db": "NVD",
"id": "CVE-2022-23158"
},
{
"db": "NVD",
"id": "CVE-2022-23158"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Wyse Device Agent version 14.6.1.4 and below contain a sensitive data exposure vulnerability. A local authenticated user with standard privilege could potentially exploit this vulnerability and provide incorrect port information and get connected to valid WMS server. An attacker could exploit this vulnerability to gain access to potentially sensitive information",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-23158"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007654"
},
{
"db": "VULHUB",
"id": "VHN-412054"
},
{
"db": "VULMON",
"id": "CVE-2022-23158"
}
],
"trust": 1.8
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-23158",
"trust": 3.4
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007654",
"trust": 0.8
},
{
"db": "CS-HELP",
"id": "SB2022021803",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1592",
"trust": 0.6
},
{
"db": "CNVD",
"id": "CNVD-2022-42741",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-412054",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2022-23158",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-412054"
},
{
"db": "VULMON",
"id": "CVE-2022-23158"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007654"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1592"
},
{
"db": "NVD",
"id": "CVE-2022-23158"
}
]
},
"id": "VAR-202202-0979",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-412054"
}
],
"trust": 0.01
},
"last_update_date": "2024-11-23T22:57:48.146000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Dell Wyse Device Agent Repair measures for information disclosure vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=182801"
},
{
"title": "CVE-2022-XXXX",
"trust": 0.1,
"url": "https://github.com/AlphabugX/CVE-2022-23305 "
},
{
"title": "CVE-2022-XXXX",
"trust": 0.1,
"url": "https://github.com/AlphabugX/CVE-2022-RCE "
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2022-23158"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1592"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-200",
"trust": 1.1
},
{
"problemtype": "CWE-183",
"trust": 1.0
},
{
"problemtype": "information leak (CWE-200) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-412054"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007654"
},
{
"db": "NVD",
"id": "CVE-2022-23158"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.6,
"url": "https://www.dell.com/support/kbdoc/000196005"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-23158"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-23158/"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2022021803"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/200.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://github.com/alphabugx/cve-2022-23305"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-412054"
},
{
"db": "VULMON",
"id": "CVE-2022-23158"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007654"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1592"
},
{
"db": "NVD",
"id": "CVE-2022-23158"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-412054"
},
{
"db": "VULMON",
"id": "CVE-2022-23158"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-007654"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-1592"
},
{
"db": "NVD",
"id": "CVE-2022-23158"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-01T00:00:00",
"db": "VULHUB",
"id": "VHN-412054"
},
{
"date": "2022-04-01T00:00:00",
"db": "VULMON",
"id": "CVE-2022-23158"
},
{
"date": "2023-07-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-007654"
},
{
"date": "2022-02-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202202-1592"
},
{
"date": "2022-04-01T20:15:08.057000",
"db": "NVD",
"id": "CVE-2022-23158"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-08T00:00:00",
"db": "VULHUB",
"id": "VHN-412054"
},
{
"date": "2022-04-08T00:00:00",
"db": "VULMON",
"id": "CVE-2022-23158"
},
{
"date": "2023-07-19T08:27:00",
"db": "JVNDB",
"id": "JVNDB-2022-007654"
},
{
"date": "2022-04-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202202-1592"
},
{
"date": "2024-11-21T06:48:06.107000",
"db": "NVD",
"id": "CVE-2022-23158"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202202-1592"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell\u0027s \u00a0Dell\u00a0Wyse\u00a0Device\u00a0Agent\u00a0 Vulnerability regarding information leakage in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-007654"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202202-1592"
}
],
"trust": 0.6
}
}
VAR-202112-1693
Vulnerability from variot - Updated: 2024-08-14 15:22Dell Wyse Device Agent version 14.5.4.1 and below contain a sensitive data exposure vulnerability. A local authenticated user with low privileges could potentially exploit this vulnerability in order to access sensitive information
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202112-1693",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wyse device agent",
"scope": "lte",
"trust": 1.0,
"vendor": "dell",
"version": "14.5.4.1"
},
{
"model": "dell wyse device agent",
"scope": "lte",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "14.5.4.1 and earlier"
},
{
"model": "dell wyse device agent",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-016803"
},
{
"db": "NVD",
"id": "CVE-2021-36341"
}
]
},
"cve": "CVE-2021-36341",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "CVE-2021-36341",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 1.9,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "VHN-398225",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 0.1,
"vectorString": "AV:L/AC:L/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2021-36341",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "OTHER",
"availabilityImpact": "None",
"baseScore": 5.5,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2021-016803",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2021-36341",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "security_alert@emc.com",
"id": "CVE-2021-36341",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2021-36341",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNNVD",
"id": "CNNVD-202112-2123",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-398225",
"trust": 0.1,
"value": "LOW"
},
{
"author": "VULMON",
"id": "CVE-2021-36341",
"trust": 0.1,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-398225"
},
{
"db": "VULMON",
"id": "CVE-2021-36341"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-016803"
},
{
"db": "CNNVD",
"id": "CNNVD-202112-2123"
},
{
"db": "NVD",
"id": "CVE-2021-36341"
},
{
"db": "NVD",
"id": "CVE-2021-36341"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell Wyse Device Agent version 14.5.4.1 and below contain a sensitive data exposure vulnerability. A local authenticated user with low privileges could potentially exploit this vulnerability in order to access sensitive information",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-36341"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-016803"
},
{
"db": "VULHUB",
"id": "VHN-398225"
},
{
"db": "VULMON",
"id": "CVE-2021-36341"
}
],
"trust": 1.8
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-36341",
"trust": 3.4
},
{
"db": "JVNDB",
"id": "JVNDB-2021-016803",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202112-2123",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-398225",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2021-36341",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-398225"
},
{
"db": "VULMON",
"id": "CVE-2021-36341"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-016803"
},
{
"db": "CNNVD",
"id": "CNNVD-202112-2123"
},
{
"db": "NVD",
"id": "CVE-2021-36341"
}
]
},
"id": "VAR-202112-1693",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-398225"
}
],
"trust": 0.01
},
"last_update_date": "2024-08-14T15:22:01.605000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "DSA-2021-232",
"trust": 0.8,
"url": "https://www.dell.com/support/kbdoc/ja-jp/000193151/dsa-2021-232"
},
{
"title": "Dell Wyse Device Agent Repair measures for information disclosure vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=175860"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-016803"
},
{
"db": "CNNVD",
"id": "CNNVD-202112-2123"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-200",
"trust": 1.1
},
{
"problemtype": "information leak (CWE-200) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-398225"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-016803"
},
{
"db": "NVD",
"id": "CVE-2021-36341"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://www.dell.com/support/kbdoc/en-us/000193151"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-36341"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/200.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-398225"
},
{
"db": "VULMON",
"id": "CVE-2021-36341"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-016803"
},
{
"db": "CNNVD",
"id": "CNNVD-202112-2123"
},
{
"db": "NVD",
"id": "CVE-2021-36341"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-398225"
},
{
"db": "VULMON",
"id": "CVE-2021-36341"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-016803"
},
{
"db": "CNNVD",
"id": "CNNVD-202112-2123"
},
{
"db": "NVD",
"id": "CVE-2021-36341"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-12-21T00:00:00",
"db": "VULHUB",
"id": "VHN-398225"
},
{
"date": "2021-12-21T00:00:00",
"db": "VULMON",
"id": "CVE-2021-36341"
},
{
"date": "2022-12-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-016803"
},
{
"date": "2021-12-21T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202112-2123"
},
{
"date": "2021-12-21T17:15:08.253000",
"db": "NVD",
"id": "CVE-2021-36341"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-12-27T00:00:00",
"db": "VULHUB",
"id": "VHN-398225"
},
{
"date": "2021-12-27T00:00:00",
"db": "VULMON",
"id": "CVE-2021-36341"
},
{
"date": "2022-12-22T05:50:00",
"db": "JVNDB",
"id": "JVNDB-2021-016803"
},
{
"date": "2021-12-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202112-2123"
},
{
"date": "2021-12-27T20:36:12.277000",
"db": "NVD",
"id": "CVE-2021-36341"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202112-2123"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell\u00a0Wyse\u00a0Device\u00a0Agent\u00a0 Vulnerability regarding information leakage in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-016803"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202112-2123"
}
],
"trust": 0.6
}
}
CVE-2019-3712 (GCVE-0-2019-3712)
Vulnerability from cvelistv5 – Published: 2019-03-07 19:00 – Updated: 2024-09-17 03:12- buffer overflow vulnerability
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/107376 | vdb-entryx_refsource_BID |
| https://www.dell.com/support/article/us/en/19/sln316391 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Wyse Device Agent |
Affected:
unspecified , ≤ 14.1.2.9
(custom)
|
|
| Dell | Wyse ThinLinux HAgent |
Affected:
unspecified , ≤ 5.4.55 00.10
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:19:18.239Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "107376",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/107376"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/article/us/en/19/sln316391"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wyse Device Agent",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "14.1.2.9",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Wyse ThinLinux HAgent",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "5.4.55 00.10",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dell would like to thank Jason Larsen of IOActive for reporting this vulnerability."
}
],
"datePublic": "2019-02-28T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Dell WES Wyse Device Agent versions prior to 14.1.2.9 and Dell Wyse ThinLinux HAgent versions prior to 5.4.55 00.10 contain a buffer overflow vulnerability. An unauthenticated attacker may potentially exploit this vulnerability to execute arbitrary code on the system with privileges of the FTP client by sending specially crafted input data to the affected system. The FTP code that contained the vulnerability has been removed."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:L",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "buffer overflow vulnerability",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-14T09:57:01.000Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"name": "107376",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/107376"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/article/us/en/19/sln316391"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "DSA-2019-039: Dell Wyse Device Agent Buffer Overflow Vulnerability",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security_alert@emc.com",
"DATE_PUBLIC": "2019-02-28T17:00:00.000Z",
"ID": "CVE-2019-3712",
"STATE": "PUBLIC",
"TITLE": "DSA-2019-039: Dell Wyse Device Agent Buffer Overflow Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wyse Device Agent",
"version": {
"version_data": [
{
"affected": "\u003c=",
"version_affected": "\u003c=",
"version_value": "14.1.2.9"
}
]
}
},
{
"product_name": "Wyse ThinLinux HAgent",
"version": {
"version_data": [
{
"affected": "\u003c=",
"version_affected": "\u003c=",
"version_value": "5.4.55 00.10"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Dell would like to thank Jason Larsen of IOActive for reporting this vulnerability."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell WES Wyse Device Agent versions prior to 14.1.2.9 and Dell Wyse ThinLinux HAgent versions prior to 5.4.55 00.10 contain a buffer overflow vulnerability. An unauthenticated attacker may potentially exploit this vulnerability to execute arbitrary code on the system with privileges of the FTP client by sending specially crafted input data to the affected system. The FTP code that contained the vulnerability has been removed."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:L",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "buffer overflow vulnerability"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "107376",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/107376"
},
{
"name": "https://www.dell.com/support/article/us/en/19/sln316391",
"refsource": "MISC",
"url": "https://www.dell.com/support/article/us/en/19/sln316391"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2019-3712",
"datePublished": "2019-03-07T19:00:00.000Z",
"dateReserved": "2019-01-03T00:00:00.000Z",
"dateUpdated": "2024-09-17T03:12:51.680Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-3712 (GCVE-0-2019-3712)
Vulnerability from nvd – Published: 2019-03-07 19:00 – Updated: 2024-09-17 03:12- buffer overflow vulnerability
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/107376 | vdb-entryx_refsource_BID |
| https://www.dell.com/support/article/us/en/19/sln316391 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Wyse Device Agent |
Affected:
unspecified , ≤ 14.1.2.9
(custom)
|
|
| Dell | Wyse ThinLinux HAgent |
Affected:
unspecified , ≤ 5.4.55 00.10
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:19:18.239Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "107376",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/107376"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/article/us/en/19/sln316391"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wyse Device Agent",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "14.1.2.9",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Wyse ThinLinux HAgent",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "5.4.55 00.10",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dell would like to thank Jason Larsen of IOActive for reporting this vulnerability."
}
],
"datePublic": "2019-02-28T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Dell WES Wyse Device Agent versions prior to 14.1.2.9 and Dell Wyse ThinLinux HAgent versions prior to 5.4.55 00.10 contain a buffer overflow vulnerability. An unauthenticated attacker may potentially exploit this vulnerability to execute arbitrary code on the system with privileges of the FTP client by sending specially crafted input data to the affected system. The FTP code that contained the vulnerability has been removed."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:L",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "buffer overflow vulnerability",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-14T09:57:01.000Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"name": "107376",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/107376"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/article/us/en/19/sln316391"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "DSA-2019-039: Dell Wyse Device Agent Buffer Overflow Vulnerability",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security_alert@emc.com",
"DATE_PUBLIC": "2019-02-28T17:00:00.000Z",
"ID": "CVE-2019-3712",
"STATE": "PUBLIC",
"TITLE": "DSA-2019-039: Dell Wyse Device Agent Buffer Overflow Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wyse Device Agent",
"version": {
"version_data": [
{
"affected": "\u003c=",
"version_affected": "\u003c=",
"version_value": "14.1.2.9"
}
]
}
},
{
"product_name": "Wyse ThinLinux HAgent",
"version": {
"version_data": [
{
"affected": "\u003c=",
"version_affected": "\u003c=",
"version_value": "5.4.55 00.10"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Dell would like to thank Jason Larsen of IOActive for reporting this vulnerability."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell WES Wyse Device Agent versions prior to 14.1.2.9 and Dell Wyse ThinLinux HAgent versions prior to 5.4.55 00.10 contain a buffer overflow vulnerability. An unauthenticated attacker may potentially exploit this vulnerability to execute arbitrary code on the system with privileges of the FTP client by sending specially crafted input data to the affected system. The FTP code that contained the vulnerability has been removed."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:L",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "buffer overflow vulnerability"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "107376",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/107376"
},
{
"name": "https://www.dell.com/support/article/us/en/19/sln316391",
"refsource": "MISC",
"url": "https://www.dell.com/support/article/us/en/19/sln316391"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2019-3712",
"datePublished": "2019-03-07T19:00:00.000Z",
"dateReserved": "2019-01-03T00:00:00.000Z",
"dateUpdated": "2024-09-17T03:12:51.680Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",