Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for Wifi by vivo

    CVE-2021-26278 (GCVE-0-2021-26278)

    Vulnerability from nvd – Published: 2024-12-17 03:05 – Updated: 2024-12-17 17:30
    VLAI
    Title
    Sensitive information leakage vulnerability in wifi module
    Summary
    The wifi module exposes the interface and has improper permission control, leaking sensitive information about the device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Vendor Product Version
    vivo Wifi Affected: Versions earlier than Android 10
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-26278",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-17T15:25:19.006568Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-17T17:30:08.414Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Wifi",
              "vendor": "vivo",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions earlier than Android 10"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The wifi module exposes the interface and has improper permission control, leaking sensitive information about the device.\u003cbr\u003e"
                }
              ],
              "value": "The wifi module exposes the interface and has improper permission control, leaking sensitive information about the device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-12-17T03:05:03.842Z",
            "orgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
            "shortName": "Vivo"
          },
          "references": [
            {
              "url": "https://www.vivo.com/en/support/security-advisory-detail?id=7"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Sensitive information leakage vulnerability in wifi module",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
        "assignerShortName": "Vivo",
        "cveId": "CVE-2021-26278",
        "datePublished": "2024-12-17T03:05:03.842Z",
        "dateReserved": "2021-01-27T19:41:45.352Z",
        "dateUpdated": "2024-12-17T17:30:08.414Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-12484 (GCVE-0-2020-12484)

    Vulnerability from nvd – Published: 2024-12-17 02:36 – Updated: 2024-12-17 14:54
    VLAI
    Summary
    When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Vendor Product Version
    vivo Wifi Affected: Versions earlier than 8.12.0.0
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2020-12484",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-17T14:54:11.114793Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-17T14:54:21.557Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Wifi",
              "vendor": "vivo",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions earlier than 8.12.0.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks.\u003cbr\u003e"
                }
              ],
              "value": "When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-151",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-151 Identity Spoofing"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-12-17T02:36:45.758Z",
            "orgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
            "shortName": "Vivo"
          },
          "references": [
            {
              "url": "https://www.vivo.com/en/support/security-advisory-detail?id=3"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
        "assignerShortName": "Vivo",
        "cveId": "CVE-2020-12484",
        "datePublished": "2024-12-17T02:36:45.758Z",
        "dateReserved": "2020-04-30T00:00:00.000Z",
        "dateUpdated": "2024-12-17T14:54:21.557Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-26278 (GCVE-0-2021-26278)

    Vulnerability from cvelistv5 – Published: 2024-12-17 03:05 – Updated: 2024-12-17 17:30
    VLAI
    Title
    Sensitive information leakage vulnerability in wifi module
    Summary
    The wifi module exposes the interface and has improper permission control, leaking sensitive information about the device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Vendor Product Version
    vivo Wifi Affected: Versions earlier than Android 10
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-26278",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-17T15:25:19.006568Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-17T17:30:08.414Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Wifi",
              "vendor": "vivo",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions earlier than Android 10"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The wifi module exposes the interface and has improper permission control, leaking sensitive information about the device.\u003cbr\u003e"
                }
              ],
              "value": "The wifi module exposes the interface and has improper permission control, leaking sensitive information about the device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-12-17T03:05:03.842Z",
            "orgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
            "shortName": "Vivo"
          },
          "references": [
            {
              "url": "https://www.vivo.com/en/support/security-advisory-detail?id=7"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Sensitive information leakage vulnerability in wifi module",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
        "assignerShortName": "Vivo",
        "cveId": "CVE-2021-26278",
        "datePublished": "2024-12-17T03:05:03.842Z",
        "dateReserved": "2021-01-27T19:41:45.352Z",
        "dateUpdated": "2024-12-17T17:30:08.414Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-12484 (GCVE-0-2020-12484)

    Vulnerability from cvelistv5 – Published: 2024-12-17 02:36 – Updated: 2024-12-17 14:54
    VLAI
    Summary
    When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Vendor Product Version
    vivo Wifi Affected: Versions earlier than 8.12.0.0
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2020-12484",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-17T14:54:11.114793Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-17T14:54:21.557Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Wifi",
              "vendor": "vivo",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions earlier than 8.12.0.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks.\u003cbr\u003e"
                }
              ],
              "value": "When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-151",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-151 Identity Spoofing"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-12-17T02:36:45.758Z",
            "orgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
            "shortName": "Vivo"
          },
          "references": [
            {
              "url": "https://www.vivo.com/en/support/security-advisory-detail?id=3"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
        "assignerShortName": "Vivo",
        "cveId": "CVE-2020-12484",
        "datePublished": "2024-12-17T02:36:45.758Z",
        "dateReserved": "2020-04-30T00:00:00.000Z",
        "dateUpdated": "2024-12-17T14:54:21.557Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }