Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
10 vulnerabilities found for WRC-F1167ACF2 by ELECOM CO.,LTD.
CVE-2023-39455 (GCVE-0-2023-39455)
Vulnerability from nvd – Published: 2023-08-18 09:42 – Updated: 2024-08-02 18:10
VLAI?
Summary
OS command injection vulnerability in ELECOM wireless LAN routers allows an authenticated user to execute an arbitrary OS command by sending a specially crafted request. Affected products and versions are as follows: WRC-600GHBK-A all versions, WRC-1467GHBK-A all versions, WRC-1900GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-F1167ACF2 all versions, WRC-1467GHBK-S all versions, and WRC-1900GHBK-S all versions.
Severity ?
No CVSS data available.
CWE
- OS command injection
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ELECOM CO.,LTD. | WRC-600GHBK-A |
Affected:
all versions
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T18:10:20.649Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.elecom.co.jp/news/security/20230810-01/"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU91630351/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "WRC-600GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "WRC-1467GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "WRC-1900GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "WRC-733FEBK2-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "WRC-F1167ACF2",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "WRC-1467GHBK-S",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "WRC-1900GHBK-S",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "OS command injection vulnerability in ELECOM wireless LAN routers allows an authenticated user to execute an arbitrary OS command by sending a specially crafted request. Affected products and versions are as follows: WRC-600GHBK-A all versions, WRC-1467GHBK-A all versions, WRC-1900GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-F1167ACF2 all versions, WRC-1467GHBK-S all versions, and WRC-1900GHBK-S all versions."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "OS command injection",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-18T09:42:19.491Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.elecom.co.jp/news/security/20230810-01/"
},
{
"url": "https://jvn.jp/en/vu/JVNVU91630351/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2023-39455",
"datePublished": "2023-08-18T09:42:19.491Z",
"dateReserved": "2023-08-09T11:55:00.303Z",
"dateUpdated": "2024-08-02T18:10:20.649Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37563 (GCVE-0-2023-37563)
Vulnerability from nvd – Published: 2023-07-13 02:59 – Updated: 2024-11-06 18:07
VLAI?
Summary
ELECOM wireless LAN routers are vulnerable to sensitive information exposure, which allows a network-adjacent unauthorized attacker to obtain sensitive information. Affected products and versions are as follows: WRC-1167GHBK-S v1.03 and earlier, WRC-1167GEBK-S v1.03 and earlier, WRC-1167FEBK-S v1.04 and earlier, WRC-1167GHBK3-A v1.24 and earlier, WRC-1167FEBK-A v1.18 and earlier, WRC-F1167ACF2 all versions, WRC-600GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-1467GHBK-A all versions, WRC-1467GHBK-S all versions, WRC-1900GHBK-A all versions, and WRC-1900GHBK-S all versions.
Severity ?
No CVSS data available.
CWE
- Information disclosure
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ELECOM CO.,LTD. | WRC-1167GHBK-S |
Affected:
v1.03 and earlier
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.899Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.elecom.co.jp/news/security/20230810-01/"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.elecom.co.jp/news/security/20230711-01/"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/jp/JVN05223215/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37563",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-06T18:06:38.318539Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-922",
"description": "CWE-922 Insecure Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-06T18:07:10.705Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "WRC-1167GHBK-S",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "v1.03 and earlier "
}
]
},
{
"product": "WRC-1167GEBK-S",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "v1.03 and earlier "
}
]
},
{
"product": "WRC-1167FEBK-S",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "v1.04 and earlier "
}
]
},
{
"product": "WRC-1167GHBK3-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "v1.24 and earlier "
}
]
},
{
"product": "WRC-1167FEBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "v1.18 and earlier "
}
]
},
{
"product": "WRC-F1167ACF2",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-600GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-733FEBK2-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-1467GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-1467GHBK-S",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-1900GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-1900GHBK-S",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "ELECOM wireless LAN routers are vulnerable to sensitive information exposure, which allows a network-adjacent unauthorized attacker to obtain sensitive information. Affected products and versions are as follows: WRC-1167GHBK-S v1.03 and earlier, WRC-1167GEBK-S v1.03 and earlier, WRC-1167FEBK-S v1.04 and earlier, WRC-1167GHBK3-A v1.24 and earlier, WRC-1167FEBK-A v1.18 and earlier, WRC-F1167ACF2 all versions, WRC-600GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-1467GHBK-A all versions, WRC-1467GHBK-S all versions, WRC-1900GHBK-A all versions, and WRC-1900GHBK-S all versions."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Information disclosure",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-18T09:31:52.811Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.elecom.co.jp/news/security/20230810-01/"
},
{
"url": "https://www.elecom.co.jp/news/security/20230711-01/"
},
{
"url": "https://jvn.jp/en/jp/JVN05223215/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2023-37563",
"datePublished": "2023-07-13T02:59:04.187Z",
"dateReserved": "2023-07-07T08:46:11.998Z",
"dateUpdated": "2024-11-06T18:07:10.705Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37567 (GCVE-0-2023-37567)
Vulnerability from nvd – Published: 2023-07-13 01:46 – Updated: 2024-11-06 14:28
VLAI?
Summary
Command injection vulnerability in ELECOM and LOGITEC wireless LAN routers allows a remote unauthenticated attacker to execute an arbitrary command by sending a specially crafted request to a certain port of the web management page. Affected products and versions are as follows: WRC-1167GHBK3-A v1.24 and earlier, WRC-F1167ACF2 all versions, WRC-600GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-1467GHBK-A all versions, WRC-1900GHBK-A all versions, and LAN-W301NR all versions.
Severity ?
No CVSS data available.
CWE
- Arbitrary command execution
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ELECOM CO.,LTD. | WRC-1167GHBK3-A |
Affected:
v1.24 and earlier
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.873Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.elecom.co.jp/news/security/20230810-01/"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.elecom.co.jp/news/security/20230711-01/"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU91850798/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:elecom:wrc-1167ghbk3-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-1167ghbk3-a",
"vendor": "elecom",
"versions": [
{
"lessThanOrEqual": "1.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-f1167acf2:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-f1167acf2",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-600ghbk-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-600ghbk-a",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-733febk2-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-733febk2-a",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-1467ghbk-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-1467ghbk-a",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-1900ghbk-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-1900ghbk-a",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:lan-w301nr:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "lan-w301nr",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37567",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-06T14:23:25.188680Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-06T14:28:41.455Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "WRC-1167GHBK3-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "v1.24 and earlier "
}
]
},
{
"product": "WRC-F1167ACF2",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-600GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-733FEBK2-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-1467GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-1900GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "LAN-W301NR",
"vendor": "LOGITEC CORPORATION",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Command injection vulnerability in ELECOM and LOGITEC wireless LAN routers allows a remote unauthenticated attacker to execute an arbitrary command by sending a specially crafted request to a certain port of the web management page. Affected products and versions are as follows: WRC-1167GHBK3-A v1.24 and earlier, WRC-F1167ACF2 all versions, WRC-600GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-1467GHBK-A all versions, WRC-1900GHBK-A all versions, and LAN-W301NR all versions."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Arbitrary command execution",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-18T09:35:14.000Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.elecom.co.jp/news/security/20230810-01/"
},
{
"url": "https://www.elecom.co.jp/news/security/20230711-01/"
},
{
"url": "https://jvn.jp/en/vu/JVNVU91850798/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2023-37567",
"datePublished": "2023-07-13T01:46:47.274Z",
"dateReserved": "2023-07-07T08:46:11.999Z",
"dateUpdated": "2024-11-06T14:28:41.455Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37566 (GCVE-0-2023-37566)
Vulnerability from nvd – Published: 2023-07-13 01:44 – Updated: 2024-11-06 18:19
VLAI?
Summary
Command injection vulnerability in ELECOM and LOGITEC wireless LAN routers allows a network-adjacent authenticated attacker to execute an arbitrary command by sending a specially crafted request to the web management page. Affected products and versions are as follows: WRC-1167GHBK3-A v1.24 and earlier, WRC-1167FEBK-A v1.18 and earlier, WRC-F1167ACF2 all versions, WRC-600GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-1467GHBK-A all versions, WRC-1900GHBK-A all versions, and LAN-W301NR all versions.
Severity ?
No CVSS data available.
CWE
- Arbitrary command execution
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ELECOM CO.,LTD. | WRC-1167GHBK3-A |
Affected:
v1.24 and earlier
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:31.016Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.elecom.co.jp/news/security/20230810-01/"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.elecom.co.jp/news/security/20230711-01/"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU91850798/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:elecom:wrc-1167ghbk3-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-1167ghbk3-a",
"vendor": "elecom",
"versions": [
{
"lessThanOrEqual": "1.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-1167febk-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-1167febk-a",
"vendor": "elecom",
"versions": [
{
"lessThanOrEqual": "1.18",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-f1167acf2:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-f1167acf2",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-600ghbk-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-600ghbk-a",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-733febk2-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-733febk2-a",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-1467ghbk-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-1467ghbk-a",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-1900ghbk-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-1900ghbk-a",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:lan-w301nr:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "lan-w301nr",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37566",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-06T18:15:05.526570Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-06T18:19:31.073Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "WRC-1167GHBK3-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "v1.24 and earlier "
}
]
},
{
"product": "WRC-1167FEBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "v1.18 and earlier "
}
]
},
{
"product": "WRC-F1167ACF2",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-600GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-733FEBK2-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-1467GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-1900GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "LAN-W301NR",
"vendor": "LOGITEC CORPORATION",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Command injection vulnerability in ELECOM and LOGITEC wireless LAN routers allows a network-adjacent authenticated attacker to execute an arbitrary command by sending a specially crafted request to the web management page. Affected products and versions are as follows: WRC-1167GHBK3-A v1.24 and earlier, WRC-1167FEBK-A v1.18 and earlier, WRC-F1167ACF2 all versions, WRC-600GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-1467GHBK-A all versions, WRC-1900GHBK-A all versions, and LAN-W301NR all versions."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Arbitrary command execution",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-18T09:34:09.134Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.elecom.co.jp/news/security/20230810-01/"
},
{
"url": "https://www.elecom.co.jp/news/security/20230711-01/"
},
{
"url": "https://jvn.jp/en/vu/JVNVU91850798/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2023-37566",
"datePublished": "2023-07-13T01:44:48.791Z",
"dateReserved": "2023-07-07T08:46:11.999Z",
"dateUpdated": "2024-11-06T18:19:31.073Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-39455 (GCVE-0-2023-39455)
Vulnerability from cvelistv5 – Published: 2023-08-18 09:42 – Updated: 2024-08-02 18:10
VLAI?
Summary
OS command injection vulnerability in ELECOM wireless LAN routers allows an authenticated user to execute an arbitrary OS command by sending a specially crafted request. Affected products and versions are as follows: WRC-600GHBK-A all versions, WRC-1467GHBK-A all versions, WRC-1900GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-F1167ACF2 all versions, WRC-1467GHBK-S all versions, and WRC-1900GHBK-S all versions.
Severity ?
No CVSS data available.
CWE
- OS command injection
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ELECOM CO.,LTD. | WRC-600GHBK-A |
Affected:
all versions
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T18:10:20.649Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.elecom.co.jp/news/security/20230810-01/"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU91630351/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "WRC-600GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "WRC-1467GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "WRC-1900GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "WRC-733FEBK2-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "WRC-F1167ACF2",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "WRC-1467GHBK-S",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "WRC-1900GHBK-S",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "OS command injection vulnerability in ELECOM wireless LAN routers allows an authenticated user to execute an arbitrary OS command by sending a specially crafted request. Affected products and versions are as follows: WRC-600GHBK-A all versions, WRC-1467GHBK-A all versions, WRC-1900GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-F1167ACF2 all versions, WRC-1467GHBK-S all versions, and WRC-1900GHBK-S all versions."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "OS command injection",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-18T09:42:19.491Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.elecom.co.jp/news/security/20230810-01/"
},
{
"url": "https://jvn.jp/en/vu/JVNVU91630351/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2023-39455",
"datePublished": "2023-08-18T09:42:19.491Z",
"dateReserved": "2023-08-09T11:55:00.303Z",
"dateUpdated": "2024-08-02T18:10:20.649Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37563 (GCVE-0-2023-37563)
Vulnerability from cvelistv5 – Published: 2023-07-13 02:59 – Updated: 2024-11-06 18:07
VLAI?
Summary
ELECOM wireless LAN routers are vulnerable to sensitive information exposure, which allows a network-adjacent unauthorized attacker to obtain sensitive information. Affected products and versions are as follows: WRC-1167GHBK-S v1.03 and earlier, WRC-1167GEBK-S v1.03 and earlier, WRC-1167FEBK-S v1.04 and earlier, WRC-1167GHBK3-A v1.24 and earlier, WRC-1167FEBK-A v1.18 and earlier, WRC-F1167ACF2 all versions, WRC-600GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-1467GHBK-A all versions, WRC-1467GHBK-S all versions, WRC-1900GHBK-A all versions, and WRC-1900GHBK-S all versions.
Severity ?
No CVSS data available.
CWE
- Information disclosure
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ELECOM CO.,LTD. | WRC-1167GHBK-S |
Affected:
v1.03 and earlier
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.899Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.elecom.co.jp/news/security/20230810-01/"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.elecom.co.jp/news/security/20230711-01/"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/jp/JVN05223215/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37563",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-06T18:06:38.318539Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-922",
"description": "CWE-922 Insecure Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-06T18:07:10.705Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "WRC-1167GHBK-S",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "v1.03 and earlier "
}
]
},
{
"product": "WRC-1167GEBK-S",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "v1.03 and earlier "
}
]
},
{
"product": "WRC-1167FEBK-S",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "v1.04 and earlier "
}
]
},
{
"product": "WRC-1167GHBK3-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "v1.24 and earlier "
}
]
},
{
"product": "WRC-1167FEBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "v1.18 and earlier "
}
]
},
{
"product": "WRC-F1167ACF2",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-600GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-733FEBK2-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-1467GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-1467GHBK-S",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-1900GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-1900GHBK-S",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "ELECOM wireless LAN routers are vulnerable to sensitive information exposure, which allows a network-adjacent unauthorized attacker to obtain sensitive information. Affected products and versions are as follows: WRC-1167GHBK-S v1.03 and earlier, WRC-1167GEBK-S v1.03 and earlier, WRC-1167FEBK-S v1.04 and earlier, WRC-1167GHBK3-A v1.24 and earlier, WRC-1167FEBK-A v1.18 and earlier, WRC-F1167ACF2 all versions, WRC-600GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-1467GHBK-A all versions, WRC-1467GHBK-S all versions, WRC-1900GHBK-A all versions, and WRC-1900GHBK-S all versions."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Information disclosure",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-18T09:31:52.811Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.elecom.co.jp/news/security/20230810-01/"
},
{
"url": "https://www.elecom.co.jp/news/security/20230711-01/"
},
{
"url": "https://jvn.jp/en/jp/JVN05223215/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2023-37563",
"datePublished": "2023-07-13T02:59:04.187Z",
"dateReserved": "2023-07-07T08:46:11.998Z",
"dateUpdated": "2024-11-06T18:07:10.705Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37567 (GCVE-0-2023-37567)
Vulnerability from cvelistv5 – Published: 2023-07-13 01:46 – Updated: 2024-11-06 14:28
VLAI?
Summary
Command injection vulnerability in ELECOM and LOGITEC wireless LAN routers allows a remote unauthenticated attacker to execute an arbitrary command by sending a specially crafted request to a certain port of the web management page. Affected products and versions are as follows: WRC-1167GHBK3-A v1.24 and earlier, WRC-F1167ACF2 all versions, WRC-600GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-1467GHBK-A all versions, WRC-1900GHBK-A all versions, and LAN-W301NR all versions.
Severity ?
No CVSS data available.
CWE
- Arbitrary command execution
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ELECOM CO.,LTD. | WRC-1167GHBK3-A |
Affected:
v1.24 and earlier
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.873Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.elecom.co.jp/news/security/20230810-01/"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.elecom.co.jp/news/security/20230711-01/"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU91850798/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:elecom:wrc-1167ghbk3-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-1167ghbk3-a",
"vendor": "elecom",
"versions": [
{
"lessThanOrEqual": "1.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-f1167acf2:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-f1167acf2",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-600ghbk-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-600ghbk-a",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-733febk2-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-733febk2-a",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-1467ghbk-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-1467ghbk-a",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-1900ghbk-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-1900ghbk-a",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:lan-w301nr:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "lan-w301nr",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37567",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-06T14:23:25.188680Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-06T14:28:41.455Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "WRC-1167GHBK3-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "v1.24 and earlier "
}
]
},
{
"product": "WRC-F1167ACF2",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-600GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-733FEBK2-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-1467GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-1900GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "LAN-W301NR",
"vendor": "LOGITEC CORPORATION",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Command injection vulnerability in ELECOM and LOGITEC wireless LAN routers allows a remote unauthenticated attacker to execute an arbitrary command by sending a specially crafted request to a certain port of the web management page. Affected products and versions are as follows: WRC-1167GHBK3-A v1.24 and earlier, WRC-F1167ACF2 all versions, WRC-600GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-1467GHBK-A all versions, WRC-1900GHBK-A all versions, and LAN-W301NR all versions."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Arbitrary command execution",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-18T09:35:14.000Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.elecom.co.jp/news/security/20230810-01/"
},
{
"url": "https://www.elecom.co.jp/news/security/20230711-01/"
},
{
"url": "https://jvn.jp/en/vu/JVNVU91850798/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2023-37567",
"datePublished": "2023-07-13T01:46:47.274Z",
"dateReserved": "2023-07-07T08:46:11.999Z",
"dateUpdated": "2024-11-06T14:28:41.455Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37566 (GCVE-0-2023-37566)
Vulnerability from cvelistv5 – Published: 2023-07-13 01:44 – Updated: 2024-11-06 18:19
VLAI?
Summary
Command injection vulnerability in ELECOM and LOGITEC wireless LAN routers allows a network-adjacent authenticated attacker to execute an arbitrary command by sending a specially crafted request to the web management page. Affected products and versions are as follows: WRC-1167GHBK3-A v1.24 and earlier, WRC-1167FEBK-A v1.18 and earlier, WRC-F1167ACF2 all versions, WRC-600GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-1467GHBK-A all versions, WRC-1900GHBK-A all versions, and LAN-W301NR all versions.
Severity ?
No CVSS data available.
CWE
- Arbitrary command execution
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ELECOM CO.,LTD. | WRC-1167GHBK3-A |
Affected:
v1.24 and earlier
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:31.016Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.elecom.co.jp/news/security/20230810-01/"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.elecom.co.jp/news/security/20230711-01/"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU91850798/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:elecom:wrc-1167ghbk3-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-1167ghbk3-a",
"vendor": "elecom",
"versions": [
{
"lessThanOrEqual": "1.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-1167febk-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-1167febk-a",
"vendor": "elecom",
"versions": [
{
"lessThanOrEqual": "1.18",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-f1167acf2:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-f1167acf2",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-600ghbk-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-600ghbk-a",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-733febk2-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-733febk2-a",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-1467ghbk-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-1467ghbk-a",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:wrc-1900ghbk-a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wrc-1900ghbk-a",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:elecom:lan-w301nr:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "lan-w301nr",
"vendor": "elecom",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37566",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-06T18:15:05.526570Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-06T18:19:31.073Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "WRC-1167GHBK3-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "v1.24 and earlier "
}
]
},
{
"product": "WRC-1167FEBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "v1.18 and earlier "
}
]
},
{
"product": "WRC-F1167ACF2",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-600GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-733FEBK2-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-1467GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "WRC-1900GHBK-A",
"vendor": "ELECOM CO.,LTD.",
"versions": [
{
"status": "affected",
"version": "all versions "
}
]
},
{
"product": "LAN-W301NR",
"vendor": "LOGITEC CORPORATION",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Command injection vulnerability in ELECOM and LOGITEC wireless LAN routers allows a network-adjacent authenticated attacker to execute an arbitrary command by sending a specially crafted request to the web management page. Affected products and versions are as follows: WRC-1167GHBK3-A v1.24 and earlier, WRC-1167FEBK-A v1.18 and earlier, WRC-F1167ACF2 all versions, WRC-600GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-1467GHBK-A all versions, WRC-1900GHBK-A all versions, and LAN-W301NR all versions."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Arbitrary command execution",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-18T09:34:09.134Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.elecom.co.jp/news/security/20230810-01/"
},
{
"url": "https://www.elecom.co.jp/news/security/20230711-01/"
},
{
"url": "https://jvn.jp/en/vu/JVNVU91850798/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2023-37566",
"datePublished": "2023-07-13T01:44:48.791Z",
"dateReserved": "2023-07-07T08:46:11.999Z",
"dateUpdated": "2024-11-06T18:19:31.073Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
JVNDB-2023-002797
Vulnerability from jvndb - Published: 2023-08-15 11:54 - Updated:2025-02-13 15:21
Severity ?
Summary
Multiple vulnerabilities in ELECOM and LOGITEC network devices
Details
Multiple network devices provided by ELECOM CO.,LTD. and LOGITEC CORPORATION contain multiple vulnerabilities listed below.
* Hidden Functionality (CWE-912) - CVE-2023-32626, CVE-2023-35991, CVE-2023-39445
* Telnet service access restriction failure (CWE-284) - CVE-2023-38132
* Hidden Functionality (CWE-912) - CVE-2023-38576
* Buffer overflow (CWE-120) - CVE-2023-39454
* OS Command Injection (CWE-78) - CVE-2023-39455, CVE-2023-40072
* OS Command Injection (CWE-78) - CVE-2023-39944, CVE-2023-40069
Chuya Hayakawa of 00One, Inc. reported this vulnerability to JPCERT/CC.
JPCERT/CC coordinated with the developer.
References
Impacted products
| Vendor | Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"@rdf:about": "https://jvndb.jvn.jp/en/contents/2023/JVNDB-2023-002797.html",
"dc:date": "2025-02-13T15:21+09:00",
"dcterms:issued": "2023-08-15T11:54+09:00",
"dcterms:modified": "2025-02-13T15:21+09:00",
"description": "Multiple network devices provided by ELECOM CO.,LTD. and LOGITEC CORPORATION contain multiple vulnerabilities listed below.\r\n\r\n * Hidden Functionality (CWE-912) - CVE-2023-32626, CVE-2023-35991, CVE-2023-39445\r\n * Telnet service access restriction failure (CWE-284) - CVE-2023-38132\r\n * Hidden Functionality (CWE-912) - CVE-2023-38576\r\n * Buffer overflow (CWE-120) - CVE-2023-39454\r\n * OS Command Injection (CWE-78) - CVE-2023-39455, CVE-2023-40072\r\n * OS Command Injection (CWE-78) - CVE-2023-39944, CVE-2023-40069\r\n\r\nChuya Hayakawa of 00One, Inc. reported this vulnerability to JPCERT/CC.\r\nJPCERT/CC coordinated with the developer.",
"link": "https://jvndb.jvn.jp/en/contents/2023/JVNDB-2023-002797.html",
"sec:cpe": [
{
"#text": "cpe:/a:elecom:wab-i1750-ps",
"@product": "WAB-I1750-PS",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/a:elecom:wab-s1167-ps",
"@product": "WAB-S1167-PS",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wab-m1775-ps_firmware",
"@product": "WAB-M1775-PS firmware",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wab-m2133_firmware",
"@product": "WAB-M2133 firmware",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wab-s1167_firmware",
"@product": "WAB-S1167 firmware",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wab-s1775_firmware",
"@product": "WAB-S1775 firmware",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wab-s300_firmware",
"@product": "WAB-S300",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wab-s600-ps_firmware",
"@product": "WAB-S600-PS",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-1167ghbk2_firmware",
"@product": "WRC-1167GHBK2 firmware",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-1467ghbk-a_firmware",
"@product": "WRC-1467GHBK-A",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-1467ghbk-s_firmware",
"@product": "WRC-1467GHBK-S",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-1750ghbk-e_firmware",
"@product": "WRC-1750GHBK-E firmware",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-1750ghbk2-i_firmware",
"@product": "WRC-1750GHBK2-I firmware",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-1750ghbk_firmware",
"@product": "WRC-1750GHBK firmware",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-1900ghbk-a_firmware",
"@product": "WRC-1900GHBK-A",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-1900ghbk-s_firmware",
"@product": "WRC-1900GHBK-S",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-600ghbk-a_firmware",
"@product": "WRC-600GHBK-A",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-733febk2-a_firmware",
"@product": "WRC-733FEBK2-A",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-f1167acf2_firmware",
"@product": "WRC-F1167ACF2",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-f1167acf_firmware",
"@product": "WRC-F1167ACF firmware",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-x1800gs-b_firmware",
"@product": "WRC-X1800GS-B",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-x1800gsa-b_firmware",
"@product": "WRC-X1800GSA-B",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-x1800gsh-b_firmware",
"@product": "WRC-X1800GSH-B",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-x6000qs-g",
"@product": "WRC-X6000QS-G",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-x6000qsa-g",
"@product": "WRC-X6000QSA-G",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:logitec:lan-w300n%2fdr_firmware",
"@product": "LAN-W300N/DR",
"@vendor": "Logitec Corp.",
"@version": "2.2"
},
{
"#text": "cpe:/o:logitec:lan-w300n%2fpr5_firmware",
"@product": "LAN-W300N/PR5",
"@vendor": "Logitec Corp.",
"@version": "2.2"
},
{
"#text": "cpe:/o:logitec:lan-w300n%2fp_firmware",
"@product": "LAN-W300N/P firmware",
"@vendor": "Logitec Corp.",
"@version": "2.2"
},
{
"#text": "cpe:/o:logitec:lan-w300n%2frs_firmware",
"@product": "LAN-W300N/RS firmware",
"@vendor": "Logitec Corp.",
"@version": "2.2"
},
{
"#text": "cpe:/o:logitec:lan-w451ngr_firmware",
"@product": "LAN-W451NGR",
"@vendor": "Logitec Corp.",
"@version": "2.2"
},
{
"#text": "cpe:/o:logitec:lan-wh300an%2fdgp_firmware",
"@product": "LAN-WH300AN/DGP",
"@vendor": "Logitec Corp.",
"@version": "2.2"
},
{
"#text": "cpe:/o:logitec:lan-wh300andgpe_firmware",
"@product": "LAN-WH300ANDGPE",
"@vendor": "Logitec Corp.",
"@version": "2.2"
},
{
"#text": "cpe:/o:logitec:lan-wh300n%2fdgp_firmware",
"@product": "LAN-WH300N/DGP firmware",
"@vendor": "Logitec Corp.",
"@version": "2.2"
},
{
"#text": "cpe:/o:logitec:lan-wh300n%2fdr_firmware",
"@product": "LAN-WH300N/DR",
"@vendor": "Logitec Corp.",
"@version": "2.2"
},
{
"#text": "cpe:/o:logitec:lan-wh300n%2fre_firmware",
"@product": "LAN-WH300N/RE",
"@vendor": "Logitec Corp.",
"@version": "2.2"
},
{
"#text": "cpe:/o:logitec:lan-wh450n%2fgp_firmware",
"@product": "LAN-WH450N/GP",
"@vendor": "Logitec Corp.",
"@version": "2.2"
}
],
"sec:cvss": [
{
"@score": "5.8",
"@severity": "Medium",
"@type": "Base",
"@vector": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"@version": "2.0"
},
{
"@score": "8.8",
"@severity": "High",
"@type": "Base",
"@vector": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"@version": "3.0"
}
],
"sec:identifier": "JVNDB-2023-002797",
"sec:references": [
{
"#text": "http://jvn.jp/en/vu/JVNVU91630351/index.html",
"@id": "JVNVU#91630351",
"@source": "JVN"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-32626",
"@id": "CVE-2023-32626",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-35991",
"@id": "CVE-2023-35991",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-38132",
"@id": "CVE-2023-38132",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-38576",
"@id": "CVE-2023-38576",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-39445",
"@id": "CVE-2023-39445",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-39454",
"@id": "CVE-2023-39454",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-39455",
"@id": "CVE-2023-39455",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-39944",
"@id": "CVE-2023-39944",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-40069",
"@id": "CVE-2023-40069",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-40072",
"@id": "CVE-2023-40072",
"@source": "CVE"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-32626",
"@id": "CVE-2023-32626",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-35991",
"@id": "CVE-2023-35991",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-38132",
"@id": "CVE-2023-38132",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-38576",
"@id": "CVE-2023-38576",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-39445",
"@id": "CVE-2023-39445",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-39454",
"@id": "CVE-2023-39454",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-39455",
"@id": "CVE-2023-39455",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-39944",
"@id": "CVE-2023-39944",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-40069",
"@id": "CVE-2023-40069",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-40072",
"@id": "CVE-2023-40072",
"@source": "NVD"
},
{
"#text": "https://cwe.mitre.org/data/definitions/120.html",
"@id": "CWE-120",
"@title": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)(CWE-120)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/284.html",
"@id": "CWE-284",
"@title": "Improper Access Control(CWE-284)"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-78",
"@title": "OS Command Injection(CWE-78)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/912.html",
"@id": "CWE-912",
"@title": "Hidden Functionality(CWE-912)"
}
],
"title": "Multiple vulnerabilities in ELECOM and LOGITEC network devices"
}
JVNDB-2023-002413
Vulnerability from jvndb - Published: 2023-07-12 16:15 - Updated:2024-04-22 16:18
Severity ?
Summary
Multiple vulnerabilities in ELECOM and LOGITEC wireless LAN routers
Details
Multiple wireless LAN routers provided by ELECOM CO.,LTD. and LOGITEC CORPORATION contain multiple vulnerabilities listed below.
* Command Injection on the web management page (CWE-77) - CVE-2023-37566, CVE-2023-37568
* Command Injection on a certain port of the web management page (CWE-77) - CVE-2023-37567
Chuya Hayakawa of 00One, Inc. reported this vulnerability to JPCERT/CC.
JPCERT/CC coordinated with the developer.
References
| Type | URL | |||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
Impacted products
| Vendor | Product | |||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||
{
"@rdf:about": "https://jvndb.jvn.jp/en/contents/2023/JVNDB-2023-002413.html",
"dc:date": "2024-04-22T16:18+09:00",
"dcterms:issued": "2023-07-12T16:15+09:00",
"dcterms:modified": "2024-04-22T16:18+09:00",
"description": "Multiple wireless LAN routers provided by ELECOM CO.,LTD. and LOGITEC CORPORATION contain multiple vulnerabilities listed below.\r\n\r\n * Command Injection on the web management page (CWE-77) - CVE-2023-37566, CVE-2023-37568\r\n * Command Injection on a certain port of the web management page (CWE-77) - CVE-2023-37567\r\n\r\nChuya Hayakawa of 00One, Inc. reported this vulnerability to JPCERT/CC.\r\nJPCERT/CC coordinated with the developer.",
"link": "https://jvndb.jvn.jp/en/contents/2023/JVNDB-2023-002413.html",
"sec:cpe": [
{
"#text": "cpe:/o:elecom:wrc-1167febk-a_firmware",
"@product": "WRC-1167FEBK-A",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-1167gebk-s_firmware",
"@product": "WRC-1167GEBK-S",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-1167ghbk-s_firmware",
"@product": "WRC-1167GHBK-S",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-1167ghbk3-a_firmware",
"@product": "WRC-1167GHBK3-A",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-1467ghbk-a_firmware",
"@product": "WRC-1467GHBK-A",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-1900ghbk-a_firmware",
"@product": "WRC-1900GHBK-A",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-600ghbk-a_firmware",
"@product": "WRC-600GHBK-A",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-733febk2-a_firmware",
"@product": "WRC-733FEBK2-A",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:elecom:wrc-f1167acf2_firmware",
"@product": "WRC-F1167ACF2",
"@vendor": "ELECOM CO.,LTD.",
"@version": "2.2"
},
{
"#text": "cpe:/o:logitec:lan-w301nr_firmware",
"@product": "LAN-W301NR firmware",
"@vendor": "Logitec Corp.",
"@version": "2.2"
}
],
"sec:cvss": [
{
"@score": "7.5",
"@severity": "High",
"@type": "Base",
"@vector": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"@version": "2.0"
},
{
"@score": "9.8",
"@severity": "Critical",
"@type": "Base",
"@vector": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"@version": "3.0"
}
],
"sec:identifier": "JVNDB-2023-002413",
"sec:references": [
{
"#text": "https://jvn.jp/en/vu/JVNVU91850798/",
"@id": "JVNVU#91850798",
"@source": "JVN"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-37566",
"@id": "CVE-2023-37566",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-37567",
"@id": "CVE-2023-37567",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-37568",
"@id": "CVE-2023-37568",
"@source": "CVE"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-37566",
"@id": "CVE-2023-37566",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-37567",
"@id": "CVE-2023-37567",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-37568",
"@id": "CVE-2023-37568",
"@source": "NVD"
},
{
"#text": "https://cwe.mitre.org/data/definitions/77.html",
"@id": "CWE-77",
"@title": "Command Injection(CWE-77)"
}
],
"title": "Multiple vulnerabilities in ELECOM and LOGITEC wireless LAN routers"
}