Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for WIFISKY 7-layer flow control router by Shenzhen Lingkong Technology

    CVE-2025-34044 (GCVE-0-2025-34044)

    Vulnerability from nvd – Published: 2025-06-26 15:51 – Updated: 2025-11-17 21:15 X_Known Exploited Vulnerability
    VLAI Shadowserver
    Title
    WIFISKY 7-Layer Flow Control Router Remote Command Execution
    Summary
    A remote command injection vulnerability exists in the confirm.php interface of the WIFISKY 7-layer Flow Control Router via a specially-crafted HTTP GET request to the t parameter. Insufficient input validation allows unauthenticated attackers to execute arbitrary OS commands. Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-25 UTC.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-34044",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-27T13:34:40.710185Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-27T13:34:55.104Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "Web Management Interface (confirm.php interface)",
                "t parameter"
              ],
              "product": "WIFISKY 7-layer flow control router",
              "vendor": "Shenzhen Lingkong Technology",
              "versions": [
                {
                  "status": "affected",
                  "version": "0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A remote command injection vulnerability exists in the \u003ccode\u003econfirm.php\u003c/code\u003e interface of the WIFISKY 7-layer Flow Control Router via a specially-crafted HTTP GET request to the t parameter. Insufficient input validation allows unauthenticated attackers to execute arbitrary OS commands.\u0026nbsp;Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-25 UTC."
                }
              ],
              "value": "A remote command injection vulnerability exists in the confirm.php interface of the WIFISKY 7-layer Flow Control Router via a specially-crafted HTTP GET request to the t parameter. Insufficient input validation allows unauthenticated attackers to execute arbitrary OS commands.\u00a0Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-25 UTC."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-17T21:15:30.068Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "tags": [
                "product"
              ],
              "url": "http://www.szwifisky.com/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.cnvd.org.cn/flaw/show/CNVD-2021-45363"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://s4e.io/tools/wifisky-7-layer-flow-control-router-remote-code-execution"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.variotdbs.pl/vuln/VAR-202107-1715/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vulncheck.com/advisories/wifisky-flow-control-router-rce"
            },
            {
              "url": "https://github.com/projectdiscovery/nuclei-templates/blob/main/http/vulnerabilities/other/wifisky7-rce.yaml"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "tags": [
            "x_known-exploited-vulnerability"
          ],
          "title": "WIFISKY 7-Layer Flow Control Router Remote Command Execution",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2025-34044",
        "datePublished": "2025-06-26T15:51:30.957Z",
        "dateReserved": "2025-04-15T19:15:22.547Z",
        "dateUpdated": "2025-11-17T21:15:30.068Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-34044 (GCVE-0-2025-34044)

    Vulnerability from cvelistv5 – Published: 2025-06-26 15:51 – Updated: 2025-11-17 21:15 X_Known Exploited Vulnerability
    VLAI Shadowserver
    Title
    WIFISKY 7-Layer Flow Control Router Remote Command Execution
    Summary
    A remote command injection vulnerability exists in the confirm.php interface of the WIFISKY 7-layer Flow Control Router via a specially-crafted HTTP GET request to the t parameter. Insufficient input validation allows unauthenticated attackers to execute arbitrary OS commands. Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-25 UTC.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-34044",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-27T13:34:40.710185Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-27T13:34:55.104Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "Web Management Interface (confirm.php interface)",
                "t parameter"
              ],
              "product": "WIFISKY 7-layer flow control router",
              "vendor": "Shenzhen Lingkong Technology",
              "versions": [
                {
                  "status": "affected",
                  "version": "0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A remote command injection vulnerability exists in the \u003ccode\u003econfirm.php\u003c/code\u003e interface of the WIFISKY 7-layer Flow Control Router via a specially-crafted HTTP GET request to the t parameter. Insufficient input validation allows unauthenticated attackers to execute arbitrary OS commands.\u0026nbsp;Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-25 UTC."
                }
              ],
              "value": "A remote command injection vulnerability exists in the confirm.php interface of the WIFISKY 7-layer Flow Control Router via a specially-crafted HTTP GET request to the t parameter. Insufficient input validation allows unauthenticated attackers to execute arbitrary OS commands.\u00a0Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-25 UTC."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-17T21:15:30.068Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "tags": [
                "product"
              ],
              "url": "http://www.szwifisky.com/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.cnvd.org.cn/flaw/show/CNVD-2021-45363"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://s4e.io/tools/wifisky-7-layer-flow-control-router-remote-code-execution"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.variotdbs.pl/vuln/VAR-202107-1715/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vulncheck.com/advisories/wifisky-flow-control-router-rce"
            },
            {
              "url": "https://github.com/projectdiscovery/nuclei-templates/blob/main/http/vulnerabilities/other/wifisky7-rce.yaml"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "tags": [
            "x_known-exploited-vulnerability"
          ],
          "title": "WIFISKY 7-Layer Flow Control Router Remote Command Execution",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2025-34044",
        "datePublished": "2025-06-26T15:51:30.957Z",
        "dateReserved": "2025-04-15T19:15:22.547Z",
        "dateUpdated": "2025-11-17T21:15:30.068Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }