    CVE-2026-114625 (GCVE-0-2026-114625)

    Vulnerability from nvd – Published: 2026-10-22 20:47 – Updated: 2026-10-23 03:55
    VLAI
    Title
    Security Advisory 0199
    Summary
    VeloCloud Orchestrator (VCO) on-prem has a security issue where this issue may allow a remote attacker to access privileged internal functionality and impact the VCO host. Successful exploitation may compromise the confidentiality, integrity, and availability of the orchestrator and data managed by the orchestrator. On an affected system, any authenticated user can gain operator privileges and masquerade as a local "superuser operator" user. This includes access to functionality that is intended for internal use only and which is not intended to be remotely accessible. Hosted, including Dedicated, versions of VCO were impacted and have already been patched.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-22 00:00 UTC
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Assigner
    Arista CNA under the mitre root
    CNA scorecard B 87/100 over 90 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Arista Networks VeloCloud Orchestrator Affected: 5.2.0 , < 5.2.3.18 (custom)
    Affected: 6.1.0 , < 6.1.3.10 (custom)
    Affected: 6.4.0 , < 6.4.2.12 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-114625",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-22T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-23T03:55:37.265Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "VeloCloud Orchestrator On-Prem"
              ],
              "product": "VeloCloud Orchestrator",
              "vendor": "Arista Networks",
              "versions": [
                {
                  "lessThan": "5.2.3.18",
                  "status": "affected",
                  "version": "5.2.0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "6.1.3.10",
                  "status": "affected",
                  "version": "6.1.0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "6.4.2.12",
                  "status": "affected",
                  "version": "6.4.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "configurations": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eVCO is exposed by default. A successful attack requires network access to the VCO web interface and a valid authenticated session on the VCO portal. The minimum user role required is \u003cstrong\u003eEnterprise Read Only\u003c/strong\u003e, the lowest built-in tenant role. There is no configuration that can prevent the exposure.\u003c/p\u003e"
                }
              ],
              "value": "VCO is exposed by default. A successful attack requires network access to the VCO web interface and a valid authenticated session on the VCO portal. The minimum user role required is Enterprise Read Only, the lowest built-in tenant role. There is no configuration that can prevent the exposure."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eVeloCloud Orchestrator (VCO) on-prem has a security issue where this issue may allow a remote attacker to access privileged internal functionality and impact the VCO host. Successful exploitation may compromise the confidentiality, integrity, and availability of the orchestrator and data managed by the orchestrator.\u003c/p\u003e\u003cp\u003eOn an affected system, any authenticated user can gain operator privileges and masquerade as a local \u0026quot;superuser operator\u0026quot; user. This includes access to functionality that is intended for internal use only and which is not intended to be remotely accessible.\u003c/p\u003e\u003cp\u003eHosted, including Dedicated, versions of VCO were impacted and have already been patched.\u003c/p\u003e"
                }
              ],
              "value": "VeloCloud Orchestrator (VCO) on-prem has a security issue where this issue may allow a remote attacker to access privileged internal functionality and impact the VCO host. Successful exploitation may compromise the confidentiality, integrity, and availability of the orchestrator and data managed by the orchestrator.\n\nOn an affected system, any authenticated user can gain operator privileges and masquerade as a local \"superuser operator\" user. This includes access to functionality that is intended for internal use only and which is not intended to be remotely accessible.\n\nHosted, including Dedicated, versions of VCO were impacted and have already been patched."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-66",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-66 SQL Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-22T20:47:56.427Z",
            "orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
            "shortName": "Arista"
          },
          "references": [
            {
              "name": "Security Advisory 0199",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24838-security-advisory-0199"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe recommended resolution is to upgrade to a fixed VCO release at your earliest convenience.\u003c/p\u003e\u003cp\u003eThese vulnerabilities have been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003eVCO \u003cstrong\u003e5.2.3.18\u003c/strong\u003e and later in the 5.2 train\u003c/li\u003e\u003cli\u003eVCO \u003cstrong\u003e6.1.3.10\u003c/strong\u003e and later in the 6.1 train\u003c/li\u003e\u003cli\u003eVCO \u003cstrong\u003e6.4.2.12\u003c/strong\u003e and later in the 6.4 train\u003c/li\u003e\u003c/ul\u003e"
                }
              ],
              "value": "The recommended resolution is to upgrade to a fixed VCO release at your earliest convenience.\n\nThese vulnerabilities have been fixed in the following releases:\n\n- VCO 5.2.3.18 and later in the 5.2 train\n- VCO 6.1.3.10 and later in the 6.1 train\n- VCO 6.4.2.12 and later in the 6.4 train"
            }
          ],
          "source": {
            "advisory": "Security Advisory 0199",
            "defects": [
              "BUG2043622"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "Security Advisory 0199",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eUntil the fixed software is deployed, operators should apply defense-in-depth controls appropriate for their environment:\u003c/p\u003e\u003cul\u003e\u003cli\u003eRestrict access to the VCO web interface to trusted administrative networks.\u003c/li\u003e\u003cli\u003eMonitor the VCO for accesses from known malicious source IPs.\u003c/li\u003e\u003cli\u003eMonitor for unexpected outbound network activity from the VCO host.\u003c/li\u003e\u003cli\u003eConsider blocking outbound ports not needed for normal activities.\u003c/li\u003e\u003cli\u003eMonitor for backdoor daemons and webshells.\u003c/li\u003e\u003cli\u003eReview recent administrator activity for unexpected changes.\u003c/li\u003e\u003c/ul\u003e"
                }
              ],
              "value": "Until the fixed software is deployed, operators should apply defense-in-depth controls appropriate for their environment:\n\n- Restrict access to the VCO web interface to trusted administrative networks.\n- Monitor the VCO for accesses from known malicious source IPs.\n- Monitor for unexpected outbound network activity from the VCO host.\n- Consider blocking outbound ports not needed for normal activities.\n- Monitor for backdoor daemons and webshells.\n- Review recent administrator activity for unexpected changes."
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
        "assignerShortName": "Arista",
        "cveId": "CVE-2026-114625",
        "datePublished": "2026-10-22T20:47:56.427Z",
        "dateReserved": "2026-10-21T20:35:35.535Z",
        "dateUpdated": "2026-10-23T03:55:37.265Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-114625 (GCVE-0-2026-114625)

    Vulnerability from cvelistv5 – Published: 2026-10-22 20:47 – Updated: 2026-10-23 03:55
    VLAI
    Title
    Security Advisory 0199
    Summary
    VeloCloud Orchestrator (VCO) on-prem has a security issue where this issue may allow a remote attacker to access privileged internal functionality and impact the VCO host. Successful exploitation may compromise the confidentiality, integrity, and availability of the orchestrator and data managed by the orchestrator. On an affected system, any authenticated user can gain operator privileges and masquerade as a local "superuser operator" user. This includes access to functionality that is intended for internal use only and which is not intended to be remotely accessible. Hosted, including Dedicated, versions of VCO were impacted and have already been patched.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-22 00:00 UTC
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Assigner
    Arista CNA under the mitre root
    CNA scorecard B 87/100 over 90 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Arista Networks VeloCloud Orchestrator Affected: 5.2.0 , < 5.2.3.18 (custom)
    Affected: 6.1.0 , < 6.1.3.10 (custom)
    Affected: 6.4.0 , < 6.4.2.12 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-114625",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-22T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-23T03:55:37.265Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "VeloCloud Orchestrator On-Prem"
              ],
              "product": "VeloCloud Orchestrator",
              "vendor": "Arista Networks",
              "versions": [
                {
                  "lessThan": "5.2.3.18",
                  "status": "affected",
                  "version": "5.2.0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "6.1.3.10",
                  "status": "affected",
                  "version": "6.1.0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "6.4.2.12",
                  "status": "affected",
                  "version": "6.4.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "configurations": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eVCO is exposed by default. A successful attack requires network access to the VCO web interface and a valid authenticated session on the VCO portal. The minimum user role required is \u003cstrong\u003eEnterprise Read Only\u003c/strong\u003e, the lowest built-in tenant role. There is no configuration that can prevent the exposure.\u003c/p\u003e"
                }
              ],
              "value": "VCO is exposed by default. A successful attack requires network access to the VCO web interface and a valid authenticated session on the VCO portal. The minimum user role required is Enterprise Read Only, the lowest built-in tenant role. There is no configuration that can prevent the exposure."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eVeloCloud Orchestrator (VCO) on-prem has a security issue where this issue may allow a remote attacker to access privileged internal functionality and impact the VCO host. Successful exploitation may compromise the confidentiality, integrity, and availability of the orchestrator and data managed by the orchestrator.\u003c/p\u003e\u003cp\u003eOn an affected system, any authenticated user can gain operator privileges and masquerade as a local \u0026quot;superuser operator\u0026quot; user. This includes access to functionality that is intended for internal use only and which is not intended to be remotely accessible.\u003c/p\u003e\u003cp\u003eHosted, including Dedicated, versions of VCO were impacted and have already been patched.\u003c/p\u003e"
                }
              ],
              "value": "VeloCloud Orchestrator (VCO) on-prem has a security issue where this issue may allow a remote attacker to access privileged internal functionality and impact the VCO host. Successful exploitation may compromise the confidentiality, integrity, and availability of the orchestrator and data managed by the orchestrator.\n\nOn an affected system, any authenticated user can gain operator privileges and masquerade as a local \"superuser operator\" user. This includes access to functionality that is intended for internal use only and which is not intended to be remotely accessible.\n\nHosted, including Dedicated, versions of VCO were impacted and have already been patched."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-66",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-66 SQL Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-22T20:47:56.427Z",
            "orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
            "shortName": "Arista"
          },
          "references": [
            {
              "name": "Security Advisory 0199",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24838-security-advisory-0199"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe recommended resolution is to upgrade to a fixed VCO release at your earliest convenience.\u003c/p\u003e\u003cp\u003eThese vulnerabilities have been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003eVCO \u003cstrong\u003e5.2.3.18\u003c/strong\u003e and later in the 5.2 train\u003c/li\u003e\u003cli\u003eVCO \u003cstrong\u003e6.1.3.10\u003c/strong\u003e and later in the 6.1 train\u003c/li\u003e\u003cli\u003eVCO \u003cstrong\u003e6.4.2.12\u003c/strong\u003e and later in the 6.4 train\u003c/li\u003e\u003c/ul\u003e"
                }
              ],
              "value": "The recommended resolution is to upgrade to a fixed VCO release at your earliest convenience.\n\nThese vulnerabilities have been fixed in the following releases:\n\n- VCO 5.2.3.18 and later in the 5.2 train\n- VCO 6.1.3.10 and later in the 6.1 train\n- VCO 6.4.2.12 and later in the 6.4 train"
            }
          ],
          "source": {
            "advisory": "Security Advisory 0199",
            "defects": [
              "BUG2043622"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "Security Advisory 0199",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eUntil the fixed software is deployed, operators should apply defense-in-depth controls appropriate for their environment:\u003c/p\u003e\u003cul\u003e\u003cli\u003eRestrict access to the VCO web interface to trusted administrative networks.\u003c/li\u003e\u003cli\u003eMonitor the VCO for accesses from known malicious source IPs.\u003c/li\u003e\u003cli\u003eMonitor for unexpected outbound network activity from the VCO host.\u003c/li\u003e\u003cli\u003eConsider blocking outbound ports not needed for normal activities.\u003c/li\u003e\u003cli\u003eMonitor for backdoor daemons and webshells.\u003c/li\u003e\u003cli\u003eReview recent administrator activity for unexpected changes.\u003c/li\u003e\u003c/ul\u003e"
                }
              ],
              "value": "Until the fixed software is deployed, operators should apply defense-in-depth controls appropriate for their environment:\n\n- Restrict access to the VCO web interface to trusted administrative networks.\n- Monitor the VCO for accesses from known malicious source IPs.\n- Monitor for unexpected outbound network activity from the VCO host.\n- Consider blocking outbound ports not needed for normal activities.\n- Monitor for backdoor daemons and webshells.\n- Review recent administrator activity for unexpected changes."
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
        "assignerShortName": "Arista",
        "cveId": "CVE-2026-114625",
        "datePublished": "2026-10-22T20:47:56.427Z",
        "dateReserved": "2026-10-21T20:35:35.535Z",
        "dateUpdated": "2026-10-23T03:55:37.265Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }