Search

Find a vulnerability

Search criteria

    8 vulnerabilities found for VR-S1000 by BUFFALO INC.

    CVE-2023-51363 (GCVE-0-2023-51363)

    Vulnerability from nvd – Published: 2023-12-26 07:30 – Updated: 2024-08-02 22:32
    VLAI
    Summary
    VR-S1000 firmware Ver. 2.37 and earlier allows a network-adjacent unauthenticated attacker who can access the product's web management page to obtain sensitive information.
    Severity
    No CVSS data available.
    CWE
    • Information disclosure
    Assigner
    Impacted products
    Vendor Product Version
    BUFFALO INC. VR-S1000 Affected: firmware Ver. 2.37 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:32:09.188Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.buffalo.jp/news/detail/20231225-01.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN23771490/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "VR-S1000",
              "vendor": "BUFFALO INC.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 2.37 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "VR-S1000 firmware Ver. 2.37 and earlier allows a network-adjacent unauthenticated attacker who can access the product\u0027s web management page to obtain sensitive information."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Information disclosure",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-12-26T07:30:12.168Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.buffalo.jp/news/detail/20231225-01.html"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN23771490/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-51363",
        "datePublished": "2023-12-26T07:30:12.168Z",
        "dateReserved": "2023-12-18T12:18:02.891Z",
        "dateUpdated": "2024-08-02T22:32:09.188Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46711 (GCVE-0-2023-46711)

    Vulnerability from nvd – Published: 2023-12-26 07:29 – Updated: 2024-09-12 18:44
    VLAI
    Summary
    VR-S1000 firmware Ver. 2.37 and earlier uses a hard-coded cryptographic key which may allow an attacker to analyze the password of a specific product user.
    Severity
    No CVSS data available.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Use of Hard-coded Cryptographic Key
    Assigner
    Impacted products
    Vendor Product Version
    BUFFALO INC. VR-S1000 Affected: firmware Ver. 2.37 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:53:20.804Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.buffalo.jp/news/detail/20231225-01.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN23771490/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-46711",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-03T20:37:14.427883Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-12T18:44:42.909Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "VR-S1000",
              "vendor": "BUFFALO INC.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 2.37 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "VR-S1000 firmware Ver. 2.37 and earlier uses a hard-coded cryptographic key which may allow an attacker to analyze the password of a specific product user."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Use of Hard-coded Cryptographic Key",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-12-26T07:29:49.181Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.buffalo.jp/news/detail/20231225-01.html"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN23771490/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-46711",
        "datePublished": "2023-12-26T07:29:49.181Z",
        "dateReserved": "2023-10-25T07:08:56.601Z",
        "dateUpdated": "2024-09-12T18:44:42.909Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46681 (GCVE-0-2023-46681)

    Vulnerability from nvd – Published: 2023-12-26 07:29 – Updated: 2024-08-02 20:53
    VLAI
    Summary
    Improper neutralization of argument delimiters in a command ('Argument Injection') vulnerability in VR-S1000 firmware Ver. 2.37 and earlier allows an authenticated attacker who can access to the product's command line interface to execute an arbitrary command.
    Severity
    No CVSS data available.
    CWE
    • Improper neutralization of argument delimiters in a command ('Argument Injection')
    Assigner
    Impacted products
    Vendor Product Version
    BUFFALO INC. VR-S1000 Affected: firmware Ver. 2.37 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:53:20.829Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.buffalo.jp/news/detail/20231225-01.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN23771490/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "VR-S1000",
              "vendor": "BUFFALO INC.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 2.37 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper neutralization of argument delimiters in a command (\u0027Argument Injection\u0027) vulnerability in VR-S1000 firmware Ver. 2.37 and earlier allows an authenticated attacker who can access to the product\u0027s command line interface to execute an arbitrary command."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper neutralization of argument delimiters in a command (\u0027Argument Injection\u0027)",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-12-26T07:29:17.894Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.buffalo.jp/news/detail/20231225-01.html"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN23771490/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-46681",
        "datePublished": "2023-12-26T07:29:17.894Z",
        "dateReserved": "2023-10-25T07:08:55.618Z",
        "dateUpdated": "2024-08-02T20:53:20.829Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-45741 (GCVE-0-2023-45741)

    Vulnerability from nvd – Published: 2023-12-26 07:28 – Updated: 2024-08-02 20:29
    VLAI
    Summary
    VR-S1000 firmware Ver. 2.37 and earlier allows an attacker with access to the product's web management page to execute arbitrary OS commands.
    Severity
    No CVSS data available.
    CWE
    • OS command injection
    Assigner
    Impacted products
    Vendor Product Version
    BUFFALO INC. VR-S1000 Affected: firmware Ver. 2.37 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:29:32.411Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.buffalo.jp/news/detail/20231225-01.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN23771490/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "VR-S1000",
              "vendor": "BUFFALO INC.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 2.37 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "VR-S1000 firmware Ver. 2.37 and earlier allows an attacker with access to the product\u0027s web management page to execute arbitrary OS commands."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "OS command injection",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-12-26T07:28:42.765Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.buffalo.jp/news/detail/20231225-01.html"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN23771490/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-45741",
        "datePublished": "2023-12-26T07:28:42.765Z",
        "dateReserved": "2023-10-25T07:08:54.707Z",
        "dateUpdated": "2024-08-02T20:29:32.411Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-51363 (GCVE-0-2023-51363)

    Vulnerability from cvelistv5 – Published: 2023-12-26 07:30 – Updated: 2024-08-02 22:32
    VLAI
    Summary
    VR-S1000 firmware Ver. 2.37 and earlier allows a network-adjacent unauthenticated attacker who can access the product's web management page to obtain sensitive information.
    Severity
    No CVSS data available.
    CWE
    • Information disclosure
    Assigner
    Impacted products
    Vendor Product Version
    BUFFALO INC. VR-S1000 Affected: firmware Ver. 2.37 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:32:09.188Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.buffalo.jp/news/detail/20231225-01.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN23771490/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "VR-S1000",
              "vendor": "BUFFALO INC.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 2.37 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "VR-S1000 firmware Ver. 2.37 and earlier allows a network-adjacent unauthenticated attacker who can access the product\u0027s web management page to obtain sensitive information."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Information disclosure",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-12-26T07:30:12.168Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.buffalo.jp/news/detail/20231225-01.html"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN23771490/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-51363",
        "datePublished": "2023-12-26T07:30:12.168Z",
        "dateReserved": "2023-12-18T12:18:02.891Z",
        "dateUpdated": "2024-08-02T22:32:09.188Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46711 (GCVE-0-2023-46711)

    Vulnerability from cvelistv5 – Published: 2023-12-26 07:29 – Updated: 2024-09-12 18:44
    VLAI
    Summary
    VR-S1000 firmware Ver. 2.37 and earlier uses a hard-coded cryptographic key which may allow an attacker to analyze the password of a specific product user.
    Severity
    No CVSS data available.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Use of Hard-coded Cryptographic Key
    Assigner
    Impacted products
    Vendor Product Version
    BUFFALO INC. VR-S1000 Affected: firmware Ver. 2.37 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:53:20.804Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.buffalo.jp/news/detail/20231225-01.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN23771490/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-46711",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-03T20:37:14.427883Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-12T18:44:42.909Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "VR-S1000",
              "vendor": "BUFFALO INC.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 2.37 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "VR-S1000 firmware Ver. 2.37 and earlier uses a hard-coded cryptographic key which may allow an attacker to analyze the password of a specific product user."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Use of Hard-coded Cryptographic Key",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-12-26T07:29:49.181Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.buffalo.jp/news/detail/20231225-01.html"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN23771490/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-46711",
        "datePublished": "2023-12-26T07:29:49.181Z",
        "dateReserved": "2023-10-25T07:08:56.601Z",
        "dateUpdated": "2024-09-12T18:44:42.909Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46681 (GCVE-0-2023-46681)

    Vulnerability from cvelistv5 – Published: 2023-12-26 07:29 – Updated: 2024-08-02 20:53
    VLAI
    Summary
    Improper neutralization of argument delimiters in a command ('Argument Injection') vulnerability in VR-S1000 firmware Ver. 2.37 and earlier allows an authenticated attacker who can access to the product's command line interface to execute an arbitrary command.
    Severity
    No CVSS data available.
    CWE
    • Improper neutralization of argument delimiters in a command ('Argument Injection')
    Assigner
    Impacted products
    Vendor Product Version
    BUFFALO INC. VR-S1000 Affected: firmware Ver. 2.37 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:53:20.829Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.buffalo.jp/news/detail/20231225-01.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN23771490/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "VR-S1000",
              "vendor": "BUFFALO INC.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 2.37 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper neutralization of argument delimiters in a command (\u0027Argument Injection\u0027) vulnerability in VR-S1000 firmware Ver. 2.37 and earlier allows an authenticated attacker who can access to the product\u0027s command line interface to execute an arbitrary command."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper neutralization of argument delimiters in a command (\u0027Argument Injection\u0027)",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-12-26T07:29:17.894Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.buffalo.jp/news/detail/20231225-01.html"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN23771490/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-46681",
        "datePublished": "2023-12-26T07:29:17.894Z",
        "dateReserved": "2023-10-25T07:08:55.618Z",
        "dateUpdated": "2024-08-02T20:53:20.829Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-45741 (GCVE-0-2023-45741)

    Vulnerability from cvelistv5 – Published: 2023-12-26 07:28 – Updated: 2024-08-02 20:29
    VLAI
    Summary
    VR-S1000 firmware Ver. 2.37 and earlier allows an attacker with access to the product's web management page to execute arbitrary OS commands.
    Severity
    No CVSS data available.
    CWE
    • OS command injection
    Assigner
    Impacted products
    Vendor Product Version
    BUFFALO INC. VR-S1000 Affected: firmware Ver. 2.37 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:29:32.411Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.buffalo.jp/news/detail/20231225-01.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN23771490/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "VR-S1000",
              "vendor": "BUFFALO INC.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 2.37 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "VR-S1000 firmware Ver. 2.37 and earlier allows an attacker with access to the product\u0027s web management page to execute arbitrary OS commands."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "OS command injection",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-12-26T07:28:42.765Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.buffalo.jp/news/detail/20231225-01.html"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN23771490/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-45741",
        "datePublished": "2023-12-26T07:28:42.765Z",
        "dateReserved": "2023-10-25T07:08:54.707Z",
        "dateUpdated": "2024-08-02T20:29:32.411Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }