    CVE-2020-10265 (GCVE-0-2020-10265)

    Vulnerability from nvd – Published: 2020-04-06 12:08 – Updated: 2024-09-17 03:07
    VLAI
    Title
    RVD#1443: UR dashboard server enables unauthenticated remote control of core robot functions
    Summary
    Universal Robots Robot Controllers Version CB2 SW Version 1.4 upwards, CB3 SW Version 3.0 and upwards, e-series SW Version 5.0 and upwards expose a service called DashBoard server at port 29999 that allows for control over core robot functions like starting/stopping programs, shutdown, reset safety and more. The DashBoard server is not protected by any kind of authentication or authorization.
    CWE
    • CWE-306 - (Missing Authentication for Critical Function)
    Assigner
    References
    Impacted products
    Date Public
    2020-04-04 00:00
    Credits
    Bernhard Dieber, Benjamin Breiling (and many others)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T10:58:39.935Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.universal-robots.com/how-tos-and-faqs/how-to/ur-how-tos/real-time-data-exchange-rtde-guide/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Universal Robots Robot Controllers CB 2, CB3, e-series",
              "vendor": "Universal Robots",
              "versions": [
                {
                  "status": "affected",
                  "version": "unspecified"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Bernhard Dieber, Benjamin Breiling (and many others)"
            }
          ],
          "datePublic": "2020-04-04T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Universal Robots Robot Controllers Version CB2 SW Version 1.4 upwards, CB3 SW Version 3.0 and upwards, e-series SW Version 5.0 and upwards expose a service called DashBoard server at port 29999 that allows for control over core robot functions like starting/stopping programs, shutdown, reset safety and more. The DashBoard server is not protected by any kind of authentication or authorization."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 (Missing Authentication for Critical Function)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-06T12:08:40.000Z",
            "orgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
            "shortName": "Alias"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.universal-robots.com/how-tos-and-faqs/how-to/ur-how-tos/real-time-data-exchange-rtde-guide/"
            }
          ],
          "source": {
            "defect": [
              "RVD#1443"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "RVD#1443: UR dashboard server enables unauthenticated remote control of core robot functions",
          "x_generator": {
            "engine": "Robot Vulnerability Database (RVD)"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@aliasrobotics.com",
              "DATE_PUBLIC": "2020-04-04T15:38:55 +00:00",
              "ID": "CVE-2020-10265",
              "STATE": "PUBLIC",
              "TITLE": "RVD#1443: UR dashboard server enables unauthenticated remote control of core robot functions"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Universal Robots Robot Controllers CB 2, CB3, e-series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": ""
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Universal Robots"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Bernhard Dieber, Benjamin Breiling (and many others)"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Universal Robots Robot Controllers Version CB2 SW Version 1.4 upwards, CB3 SW Version 3.0 and upwards, e-series SW Version 5.0 and upwards expose a service called DashBoard server at port 29999 that allows for control over core robot functions like starting/stopping programs, shutdown, reset safety and more. The DashBoard server is not protected by any kind of authentication or authorization."
                }
              ]
            },
            "generator": {
              "engine": "Robot Vulnerability Database (RVD)"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.4,
                "baseSeverity": "critical",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
                "version": "3.0"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-306 (Missing Authentication for Critical Function)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.universal-robots.com/how-tos-and-faqs/how-to/ur-how-tos/real-time-data-exchange-rtde-guide/",
                  "refsource": "CONFIRM",
                  "url": "https://www.universal-robots.com/how-tos-and-faqs/how-to/ur-how-tos/real-time-data-exchange-rtde-guide/"
                }
              ]
            },
            "source": {
              "defect": [
                "RVD#1443"
              ],
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
        "assignerShortName": "Alias",
        "cveId": "CVE-2020-10265",
        "datePublished": "2020-04-06T12:08:40.665Z",
        "dateReserved": "2020-03-10T00:00:00.000Z",
        "dateUpdated": "2024-09-17T03:07:51.861Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-10265 (GCVE-0-2020-10265)

    Vulnerability from cvelistv5 – Published: 2020-04-06 12:08 – Updated: 2024-09-17 03:07
    VLAI
    Title
    RVD#1443: UR dashboard server enables unauthenticated remote control of core robot functions
    Summary
    Universal Robots Robot Controllers Version CB2 SW Version 1.4 upwards, CB3 SW Version 3.0 and upwards, e-series SW Version 5.0 and upwards expose a service called DashBoard server at port 29999 that allows for control over core robot functions like starting/stopping programs, shutdown, reset safety and more. The DashBoard server is not protected by any kind of authentication or authorization.
    CWE
    • CWE-306 - (Missing Authentication for Critical Function)
    Assigner
    References
    Impacted products
    Date Public
    2020-04-04 00:00
    Credits
    Bernhard Dieber, Benjamin Breiling (and many others)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T10:58:39.935Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.universal-robots.com/how-tos-and-faqs/how-to/ur-how-tos/real-time-data-exchange-rtde-guide/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Universal Robots Robot Controllers CB 2, CB3, e-series",
              "vendor": "Universal Robots",
              "versions": [
                {
                  "status": "affected",
                  "version": "unspecified"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Bernhard Dieber, Benjamin Breiling (and many others)"
            }
          ],
          "datePublic": "2020-04-04T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Universal Robots Robot Controllers Version CB2 SW Version 1.4 upwards, CB3 SW Version 3.0 and upwards, e-series SW Version 5.0 and upwards expose a service called DashBoard server at port 29999 that allows for control over core robot functions like starting/stopping programs, shutdown, reset safety and more. The DashBoard server is not protected by any kind of authentication or authorization."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 (Missing Authentication for Critical Function)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-06T12:08:40.000Z",
            "orgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
            "shortName": "Alias"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.universal-robots.com/how-tos-and-faqs/how-to/ur-how-tos/real-time-data-exchange-rtde-guide/"
            }
          ],
          "source": {
            "defect": [
              "RVD#1443"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "RVD#1443: UR dashboard server enables unauthenticated remote control of core robot functions",
          "x_generator": {
            "engine": "Robot Vulnerability Database (RVD)"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@aliasrobotics.com",
              "DATE_PUBLIC": "2020-04-04T15:38:55 +00:00",
              "ID": "CVE-2020-10265",
              "STATE": "PUBLIC",
              "TITLE": "RVD#1443: UR dashboard server enables unauthenticated remote control of core robot functions"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Universal Robots Robot Controllers CB 2, CB3, e-series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": ""
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Universal Robots"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Bernhard Dieber, Benjamin Breiling (and many others)"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Universal Robots Robot Controllers Version CB2 SW Version 1.4 upwards, CB3 SW Version 3.0 and upwards, e-series SW Version 5.0 and upwards expose a service called DashBoard server at port 29999 that allows for control over core robot functions like starting/stopping programs, shutdown, reset safety and more. The DashBoard server is not protected by any kind of authentication or authorization."
                }
              ]
            },
            "generator": {
              "engine": "Robot Vulnerability Database (RVD)"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.4,
                "baseSeverity": "critical",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
                "version": "3.0"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-306 (Missing Authentication for Critical Function)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.universal-robots.com/how-tos-and-faqs/how-to/ur-how-tos/real-time-data-exchange-rtde-guide/",
                  "refsource": "CONFIRM",
                  "url": "https://www.universal-robots.com/how-tos-and-faqs/how-to/ur-how-tos/real-time-data-exchange-rtde-guide/"
                }
              ]
            },
            "source": {
              "defect": [
                "RVD#1443"
              ],
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
        "assignerShortName": "Alias",
        "cveId": "CVE-2020-10265",
        "datePublished": "2020-04-06T12:08:40.665Z",
        "dateReserved": "2020-03-10T00:00:00.000Z",
        "dateUpdated": "2024-09-17T03:07:51.861Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }