    CVE-2025-10847 (GCVE-0-2025-10847)

    Vulnerability from nvd – Published: 2025-10-01 10:48 – Updated: 2026-02-26 17:48
    VLAI
    Title
    DX UIM Probe Improper ACL Handling RCE
    Summary
    DX Unified Infrastructure Management (Nimsoft/UIM) and below contains an improper ACL handling vulnerability in the robot (controller) component. A remote attacker can execute commands, read from, or write to the target system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    References
    Impacted products
    Credits
    Australian Signals Directorate (Cyber.gov.au)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-10847",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-03T03:55:35.626648Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-284",
                    "description": "CWE-284 Improper Access Control",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:48:26.038Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Unified Infrastructure Management",
              "vendor": "Broadcom",
              "versions": [
                {
                  "status": "affected",
                  "version": "23.4.5"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Australian Signals Directorate (Cyber.gov.au)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDX Unified Infrastructure Management (Nimsoft/UIM) and below contains an improper ACL handling vulnerability in the robot (controller) component. A remote attacker can execute commands, read from, or write to the target system.\u003c/span\u003e"
                }
              ],
              "value": "DX Unified Infrastructure Management (Nimsoft/UIM) and below contains an improper ACL handling vulnerability in the robot (controller) component. A remote attacker can execute commands, read from, or write to the target system."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "USER",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "AMBER",
                "subAvailabilityImpact": "LOW",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "DIFFUSE",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:L/VI:H/VA:H/SC:L/SI:N/SA:L/S:N/AU:Y/R:U/V:D/RE:L/U:Amber",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "LOW"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-01T10:48:12.150Z",
            "orgId": "80d3bcb6-88de-48c2-a47e-aebf795f19b5",
            "shortName": "symantec"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/36180"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "DX UIM Probe Improper ACL Handling RCE",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "80d3bcb6-88de-48c2-a47e-aebf795f19b5",
        "assignerShortName": "symantec",
        "cveId": "CVE-2025-10847",
        "datePublished": "2025-10-01T10:48:12.150Z",
        "dateReserved": "2025-09-22T05:46:46.329Z",
        "dateUpdated": "2026-02-26T17:48:26.038Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-10847 (GCVE-0-2025-10847)

    Vulnerability from cvelistv5 – Published: 2025-10-01 10:48 – Updated: 2026-02-26 17:48
    VLAI
    Title
    DX UIM Probe Improper ACL Handling RCE
    Summary
    DX Unified Infrastructure Management (Nimsoft/UIM) and below contains an improper ACL handling vulnerability in the robot (controller) component. A remote attacker can execute commands, read from, or write to the target system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    References
    Impacted products
    Credits
    Australian Signals Directorate (Cyber.gov.au)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-10847",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-03T03:55:35.626648Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-284",
                    "description": "CWE-284 Improper Access Control",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:48:26.038Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Unified Infrastructure Management",
              "vendor": "Broadcom",
              "versions": [
                {
                  "status": "affected",
                  "version": "23.4.5"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Australian Signals Directorate (Cyber.gov.au)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDX Unified Infrastructure Management (Nimsoft/UIM) and below contains an improper ACL handling vulnerability in the robot (controller) component. A remote attacker can execute commands, read from, or write to the target system.\u003c/span\u003e"
                }
              ],
              "value": "DX Unified Infrastructure Management (Nimsoft/UIM) and below contains an improper ACL handling vulnerability in the robot (controller) component. A remote attacker can execute commands, read from, or write to the target system."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "USER",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "AMBER",
                "subAvailabilityImpact": "LOW",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "DIFFUSE",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:L/VI:H/VA:H/SC:L/SI:N/SA:L/S:N/AU:Y/R:U/V:D/RE:L/U:Amber",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "LOW"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-01T10:48:12.150Z",
            "orgId": "80d3bcb6-88de-48c2-a47e-aebf795f19b5",
            "shortName": "symantec"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/36180"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "DX UIM Probe Improper ACL Handling RCE",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "80d3bcb6-88de-48c2-a47e-aebf795f19b5",
        "assignerShortName": "symantec",
        "cveId": "CVE-2025-10847",
        "datePublished": "2025-10-01T10:48:12.150Z",
        "dateReserved": "2025-09-22T05:46:46.329Z",
        "dateUpdated": "2026-02-26T17:48:26.038Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }