Search criteria

8 vulnerabilities found for U.motion Builder by Schneider Electric SE

CVE-2018-7787 (GCVE-0-2018-7787)

Vulnerability from nvd – Published: 2018-07-03 14:00 – Updated: 2024-09-17 02:48
VLAI?
Summary
In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTP GET request.
Severity ?
No CVSS data available.
CWE
  • Improper Input Validation
Assigner
References
Impacted products
Vendor Product Version
Schneider Electric SE U.motion Builder Affected: U.motion Builder, all versions prior to 1.3.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:37:59.351Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
          },
          {
            "name": "104447",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/104447"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "U.motion Builder",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "U.motion Builder, all versions prior to 1.3.4"
            }
          ]
        }
      ],
      "datePublic": "2018-05-31T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTP GET request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Improper Input Validation",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-07-04T09:57:01",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
        },
        {
          "name": "104447",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/104447"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "DATE_PUBLIC": "2018-05-31T00:00:00",
          "ID": "CVE-2018-7787",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "U.motion Builder",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "U.motion Builder, all versions prior to 1.3.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTP GET request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Improper Input Validation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
            },
            {
              "name": "104447",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/104447"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2018-7787",
    "datePublished": "2018-07-03T14:00:00Z",
    "dateReserved": "2018-03-08T00:00:00",
    "dateUpdated": "2024-09-17T02:48:14.082Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-7786 (GCVE-0-2018-7786)

Vulnerability from nvd – Published: 2018-07-03 14:00 – Updated: 2024-09-17 02:06
VLAI?
Summary
In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicious scripts.
Severity ?
No CVSS data available.
CWE
  • Cross Site Scripting
Assigner
References
Impacted products
Vendor Product Version
Schneider Electric SE U.motion Builder Affected: U.motion Builder, all versions prior to 1.3.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:37:58.722Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
          },
          {
            "name": "104447",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/104447"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "U.motion Builder",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "U.motion Builder, all versions prior to 1.3.4"
            }
          ]
        }
      ],
      "datePublic": "2018-05-31T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicious scripts."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Cross Site Scripting",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-07-04T09:57:01",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
        },
        {
          "name": "104447",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/104447"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "DATE_PUBLIC": "2018-05-31T00:00:00",
          "ID": "CVE-2018-7786",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "U.motion Builder",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "U.motion Builder, all versions prior to 1.3.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicious scripts."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Cross Site Scripting"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
            },
            {
              "name": "104447",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/104447"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2018-7786",
    "datePublished": "2018-07-03T14:00:00Z",
    "dateReserved": "2018-03-08T00:00:00",
    "dateUpdated": "2024-09-17T02:06:28.904Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-7785 (GCVE-0-2018-7785)

Vulnerability from nvd – Published: 2018-07-03 14:00 – Updated: 2024-09-16 18:08
VLAI?
Summary
In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass.
Severity ?
No CVSS data available.
CWE
  • Remote Command Injection
Assigner
References
Impacted products
Vendor Product Version
Schneider Electric SE U.motion Builder Affected: U.motion Builder, all versions prior to 1.3.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:37:59.642Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
          },
          {
            "name": "104447",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/104447"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "U.motion Builder",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "U.motion Builder, all versions prior to 1.3.4"
            }
          ]
        }
      ],
      "datePublic": "2018-05-31T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Remote Command Injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-07-04T09:57:01",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
        },
        {
          "name": "104447",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/104447"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "DATE_PUBLIC": "2018-05-31T00:00:00",
          "ID": "CVE-2018-7785",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "U.motion Builder",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "U.motion Builder, all versions prior to 1.3.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Remote Command Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
            },
            {
              "name": "104447",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/104447"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2018-7785",
    "datePublished": "2018-07-03T14:00:00Z",
    "dateReserved": "2018-03-08T00:00:00",
    "dateUpdated": "2024-09-16T18:08:37.585Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-7784 (GCVE-0-2018-7784)

Vulnerability from nvd – Published: 2018-07-03 14:00 – Updated: 2024-09-16 19:35
VLAI?
Summary
In Schneider Electric U.motion Builder software versions prior to v1.3.4, this exploit occurs when the submitted data of an input string is evaluated as a command by the application. In this way, the attacker could execute code, read the stack, or cause a segmentation fault in the running application.
Severity ?
No CVSS data available.
CWE
  • Print Format Vulnerability
Assigner
References
Impacted products
Vendor Product Version
Schneider Electric SE U.motion Builder Affected: U.motion Builder, all versions prior to 1.3.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:37:58.918Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
          },
          {
            "name": "104447",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/104447"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "U.motion Builder",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "U.motion Builder, all versions prior to 1.3.4"
            }
          ]
        }
      ],
      "datePublic": "2018-05-31T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In Schneider Electric U.motion Builder software versions prior to v1.3.4, this exploit occurs when the submitted data of an input string is evaluated as a command by the application. In this way, the attacker could execute code, read the stack, or cause a segmentation fault in the running application."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Print Format Vulnerability",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-07-04T09:57:01",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
        },
        {
          "name": "104447",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/104447"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "DATE_PUBLIC": "2018-05-31T00:00:00",
          "ID": "CVE-2018-7784",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "U.motion Builder",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "U.motion Builder, all versions prior to 1.3.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Schneider Electric U.motion Builder software versions prior to v1.3.4, this exploit occurs when the submitted data of an input string is evaluated as a command by the application. In this way, the attacker could execute code, read the stack, or cause a segmentation fault in the running application."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Print Format Vulnerability"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
            },
            {
              "name": "104447",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/104447"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2018-7784",
    "datePublished": "2018-07-03T14:00:00Z",
    "dateReserved": "2018-03-08T00:00:00",
    "dateUpdated": "2024-09-16T19:35:35.515Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-7787 (GCVE-0-2018-7787)

Vulnerability from cvelistv5 – Published: 2018-07-03 14:00 – Updated: 2024-09-17 02:48
VLAI?
Summary
In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTP GET request.
Severity ?
No CVSS data available.
CWE
  • Improper Input Validation
Assigner
References
Impacted products
Vendor Product Version
Schneider Electric SE U.motion Builder Affected: U.motion Builder, all versions prior to 1.3.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:37:59.351Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
          },
          {
            "name": "104447",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/104447"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "U.motion Builder",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "U.motion Builder, all versions prior to 1.3.4"
            }
          ]
        }
      ],
      "datePublic": "2018-05-31T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTP GET request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Improper Input Validation",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-07-04T09:57:01",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
        },
        {
          "name": "104447",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/104447"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "DATE_PUBLIC": "2018-05-31T00:00:00",
          "ID": "CVE-2018-7787",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "U.motion Builder",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "U.motion Builder, all versions prior to 1.3.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTP GET request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Improper Input Validation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
            },
            {
              "name": "104447",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/104447"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2018-7787",
    "datePublished": "2018-07-03T14:00:00Z",
    "dateReserved": "2018-03-08T00:00:00",
    "dateUpdated": "2024-09-17T02:48:14.082Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-7786 (GCVE-0-2018-7786)

Vulnerability from cvelistv5 – Published: 2018-07-03 14:00 – Updated: 2024-09-17 02:06
VLAI?
Summary
In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicious scripts.
Severity ?
No CVSS data available.
CWE
  • Cross Site Scripting
Assigner
References
Impacted products
Vendor Product Version
Schneider Electric SE U.motion Builder Affected: U.motion Builder, all versions prior to 1.3.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:37:58.722Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
          },
          {
            "name": "104447",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/104447"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "U.motion Builder",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "U.motion Builder, all versions prior to 1.3.4"
            }
          ]
        }
      ],
      "datePublic": "2018-05-31T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicious scripts."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Cross Site Scripting",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-07-04T09:57:01",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
        },
        {
          "name": "104447",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/104447"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "DATE_PUBLIC": "2018-05-31T00:00:00",
          "ID": "CVE-2018-7786",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "U.motion Builder",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "U.motion Builder, all versions prior to 1.3.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicious scripts."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Cross Site Scripting"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
            },
            {
              "name": "104447",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/104447"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2018-7786",
    "datePublished": "2018-07-03T14:00:00Z",
    "dateReserved": "2018-03-08T00:00:00",
    "dateUpdated": "2024-09-17T02:06:28.904Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-7785 (GCVE-0-2018-7785)

Vulnerability from cvelistv5 – Published: 2018-07-03 14:00 – Updated: 2024-09-16 18:08
VLAI?
Summary
In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass.
Severity ?
No CVSS data available.
CWE
  • Remote Command Injection
Assigner
References
Impacted products
Vendor Product Version
Schneider Electric SE U.motion Builder Affected: U.motion Builder, all versions prior to 1.3.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:37:59.642Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
          },
          {
            "name": "104447",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/104447"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "U.motion Builder",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "U.motion Builder, all versions prior to 1.3.4"
            }
          ]
        }
      ],
      "datePublic": "2018-05-31T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Remote Command Injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-07-04T09:57:01",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
        },
        {
          "name": "104447",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/104447"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "DATE_PUBLIC": "2018-05-31T00:00:00",
          "ID": "CVE-2018-7785",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "U.motion Builder",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "U.motion Builder, all versions prior to 1.3.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Remote Command Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
            },
            {
              "name": "104447",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/104447"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2018-7785",
    "datePublished": "2018-07-03T14:00:00Z",
    "dateReserved": "2018-03-08T00:00:00",
    "dateUpdated": "2024-09-16T18:08:37.585Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-7784 (GCVE-0-2018-7784)

Vulnerability from cvelistv5 – Published: 2018-07-03 14:00 – Updated: 2024-09-16 19:35
VLAI?
Summary
In Schneider Electric U.motion Builder software versions prior to v1.3.4, this exploit occurs when the submitted data of an input string is evaluated as a command by the application. In this way, the attacker could execute code, read the stack, or cause a segmentation fault in the running application.
Severity ?
No CVSS data available.
CWE
  • Print Format Vulnerability
Assigner
References
Impacted products
Vendor Product Version
Schneider Electric SE U.motion Builder Affected: U.motion Builder, all versions prior to 1.3.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:37:58.918Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
          },
          {
            "name": "104447",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/104447"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "U.motion Builder",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "U.motion Builder, all versions prior to 1.3.4"
            }
          ]
        }
      ],
      "datePublic": "2018-05-31T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In Schneider Electric U.motion Builder software versions prior to v1.3.4, this exploit occurs when the submitted data of an input string is evaluated as a command by the application. In this way, the attacker could execute code, read the stack, or cause a segmentation fault in the running application."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Print Format Vulnerability",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-07-04T09:57:01",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
        },
        {
          "name": "104447",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/104447"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "DATE_PUBLIC": "2018-05-31T00:00:00",
          "ID": "CVE-2018-7784",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "U.motion Builder",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "U.motion Builder, all versions prior to 1.3.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Schneider Electric U.motion Builder software versions prior to v1.3.4, this exploit occurs when the submitted data of an input string is evaluated as a command by the application. In this way, the attacker could execute code, read the stack, or cause a segmentation fault in the running application."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Print Format Vulnerability"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"
            },
            {
              "name": "104447",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/104447"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2018-7784",
    "datePublished": "2018-07-03T14:00:00Z",
    "dateReserved": "2018-03-08T00:00:00",
    "dateUpdated": "2024-09-16T19:35:35.515Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}