Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for Touch Panel 600 Marine Line by WAGO

    CVE-2023-4089 (GCVE-0-2023-4089)

    Vulnerability from nvd – Published: 2023-10-17 06:00 – Updated: 2025-02-27 20:40
    VLAI
    Title
    WAGO: Multiple products vulnerable to local file inclusion
    Summary
    On affected Wago products an remote attacker with administrative privileges can access files to which he has already access to through an undocumented local file inclusion. This access is logged in a different log file than expected.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-610 - Externally Controlled Reference to a Resource in Another Sphere
    Assigner
    References
    Impacted products
    Credits
    Floris Hendriks and Jeroen Wijenbergh from Radboud University
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T07:17:11.728Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2023-046/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-4089",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-26T21:49:11.155380Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-27T20:40:32.064Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW26",
                  "status": "affected",
                  "version": "FW19",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW26",
                  "status": "affected",
                  "version": "FW18",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW26",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW26",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW26",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW26",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW26",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Floris Hendriks and Jeroen Wijenbergh from Radboud University"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "On affected Wago products an remote attacker with administrative privileges can access files to which he has already access to through an undocumented local file inclusion. This access is logged in a different log file than expected."
                }
              ],
              "value": "On affected Wago products an remote attacker with administrative privileges can access files to which he has already access to through an undocumented local file inclusion. This access is logged in a different log file than expected."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 2.7,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-610",
                  "description": "CWE-610 Externally Controlled Reference to a Resource in Another Sphere",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-17T06:00:28.908Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2023-046/"
            }
          ],
          "source": {
            "advisory": "VDE-2023-046",
            "defect": [
              "CERT@VDE#64532"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "WAGO: Multiple products vulnerable to local file inclusion",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2023-4089",
        "datePublished": "2023-10-17T06:00:28.908Z",
        "dateReserved": "2023-08-02T07:20:35.600Z",
        "dateUpdated": "2025-02-27T20:40:32.064Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-1698 (GCVE-0-2023-1698)

    Vulnerability from nvd – Published: 2023-05-15 08:51 – Updated: 2025-01-23 19:13
    VLAI Shadowserver KEVIntel
    Title
    WAGO: WBM Command Injection in multiple products
    Summary
    In multiple products of WAGO a vulnerability allows an unauthenticated, remote attacker to create new users and change the device configuration which can result in unintended behaviour, Denial of Service and full system compromise.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Credits
    Quentin Kaiser from ONEKEY
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T05:57:24.816Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2023-007/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-1698",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-23T19:12:48.907770Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-23T19:13:09.654Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW22",
                  "status": "affected",
                  "version": "FW20",
                  "versionType": "semver"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW22"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW22",
                  "status": "affected",
                  "version": "FW20",
                  "versionType": "semver"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW22",
                  "status": "affected",
                  "version": "FW20",
                  "versionType": "semver"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW22"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW22"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW22"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Quentin Kaiser from ONEKEY"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "In multiple products of WAGO a vulnerability allows an unauthenticated, remote attacker to create new users and change the device configuration which can result in unintended behaviour, Denial of Service and full system compromise."
                }
              ],
              "value": "In multiple products of WAGO a vulnerability allows an unauthenticated, remote attacker to create new users and change the device configuration which can result in unintended behaviour, Denial of Service and full system compromise."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-15T08:51:27.453Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2023-007/"
            }
          ],
          "source": {
            "advisory": "VDE-2023-007",
            "defect": [
              "CERT@VDE#64422"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "WAGO: WBM Command Injection in multiple products",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2023-1698",
        "datePublished": "2023-05-15T08:51:27.453Z",
        "dateReserved": "2023-03-29T13:00:05.618Z",
        "dateUpdated": "2025-01-23T19:13:09.654Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-4089 (GCVE-0-2023-4089)

    Vulnerability from cvelistv5 – Published: 2023-10-17 06:00 – Updated: 2025-02-27 20:40
    VLAI
    Title
    WAGO: Multiple products vulnerable to local file inclusion
    Summary
    On affected Wago products an remote attacker with administrative privileges can access files to which he has already access to through an undocumented local file inclusion. This access is logged in a different log file than expected.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-610 - Externally Controlled Reference to a Resource in Another Sphere
    Assigner
    References
    Impacted products
    Credits
    Floris Hendriks and Jeroen Wijenbergh from Radboud University
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T07:17:11.728Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2023-046/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-4089",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-26T21:49:11.155380Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-27T20:40:32.064Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW26",
                  "status": "affected",
                  "version": "FW19",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW26",
                  "status": "affected",
                  "version": "FW18",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW26",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW26",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW26",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW26",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW26",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Floris Hendriks and Jeroen Wijenbergh from Radboud University"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "On affected Wago products an remote attacker with administrative privileges can access files to which he has already access to through an undocumented local file inclusion. This access is logged in a different log file than expected."
                }
              ],
              "value": "On affected Wago products an remote attacker with administrative privileges can access files to which he has already access to through an undocumented local file inclusion. This access is logged in a different log file than expected."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 2.7,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-610",
                  "description": "CWE-610 Externally Controlled Reference to a Resource in Another Sphere",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-17T06:00:28.908Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2023-046/"
            }
          ],
          "source": {
            "advisory": "VDE-2023-046",
            "defect": [
              "CERT@VDE#64532"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "WAGO: Multiple products vulnerable to local file inclusion",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2023-4089",
        "datePublished": "2023-10-17T06:00:28.908Z",
        "dateReserved": "2023-08-02T07:20:35.600Z",
        "dateUpdated": "2025-02-27T20:40:32.064Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-1698 (GCVE-0-2023-1698)

    Vulnerability from cvelistv5 – Published: 2023-05-15 08:51 – Updated: 2025-01-23 19:13
    VLAI Shadowserver KEVIntel
    Title
    WAGO: WBM Command Injection in multiple products
    Summary
    In multiple products of WAGO a vulnerability allows an unauthenticated, remote attacker to create new users and change the device configuration which can result in unintended behaviour, Denial of Service and full system compromise.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Credits
    Quentin Kaiser from ONEKEY
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T05:57:24.816Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2023-007/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-1698",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-23T19:12:48.907770Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-23T19:13:09.654Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW22",
                  "status": "affected",
                  "version": "FW20",
                  "versionType": "semver"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW22"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW22",
                  "status": "affected",
                  "version": "FW20",
                  "versionType": "semver"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW22",
                  "status": "affected",
                  "version": "FW20",
                  "versionType": "semver"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW22"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW22"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW22"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Quentin Kaiser from ONEKEY"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "In multiple products of WAGO a vulnerability allows an unauthenticated, remote attacker to create new users and change the device configuration which can result in unintended behaviour, Denial of Service and full system compromise."
                }
              ],
              "value": "In multiple products of WAGO a vulnerability allows an unauthenticated, remote attacker to create new users and change the device configuration which can result in unintended behaviour, Denial of Service and full system compromise."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-15T08:51:27.453Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2023-007/"
            }
          ],
          "source": {
            "advisory": "VDE-2023-007",
            "defect": [
              "CERT@VDE#64422"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "WAGO: WBM Command Injection in multiple products",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2023-1698",
        "datePublished": "2023-05-15T08:51:27.453Z",
        "dateReserved": "2023-03-29T13:00:05.618Z",
        "dateUpdated": "2025-01-23T19:13:09.654Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }