CVE-2018-25140 (GCVE-0-2018-25140)
Vulnerability from nvd – Published: 2025-12-24 19:27 – Updated: 2025-12-24 20:26
VLAI
Title
FLIR Thermal Traffic Cameras V1.01-0bb5b27 Unauthenticated Websocket Device Manipulation
Summary
FLIR thermal traffic cameras contain an unauthenticated device manipulation vulnerability in their WebSocket implementation that allows attackers to bypass authentication and authorization controls. Attackers can directly modify device configurations, access system information, and potentially initiate denial of service by sending crafted WebSocket messages without authentication.
Severity
7.5 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.exploit-db.com/exploits/45539 | exploit |
| https://www.flir.com | product |
| https://www.zeroscience.mk/en/vulnerabilities/ZSL… | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| FLIR Systems, Inc. | Thermal Traffic Cameras |
Affected:
V1.01-0bb5b27
Affected: E1.00.09 Affected: V1.02.P01 Affected: V1.05.P01 Affected: V1.04.P02 Affected: V1.04 Affected: V1.01.P02 Affected: V1.05.P03 Affected: V1.06 Affected: V1.02.P02 |
Date Public
2018-10-06 00:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2018-25140",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-24T20:12:35.313246Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-24T20:26:09.413Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2018-5490.php"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Thermal Traffic Cameras",
"vendor": "FLIR Systems, Inc.",
"versions": [
{
"status": "affected",
"version": "V1.01-0bb5b27"
},
{
"status": "affected",
"version": "E1.00.09"
},
{
"status": "affected",
"version": "V1.02.P01"
},
{
"status": "affected",
"version": "V1.05.P01"
},
{
"status": "affected",
"version": "V1.04.P02"
},
{
"status": "affected",
"version": "V1.04"
},
{
"status": "affected",
"version": "V1.01.P02"
},
{
"status": "affected",
"version": "V1.05.P03"
},
{
"status": "affected",
"version": "V1.06"
},
{
"status": "affected",
"version": "V1.02.P02"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "LiquidWorm as Gjoko Krstic of Zero Science Lab"
}
],
"datePublic": "2018-10-06T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "FLIR thermal traffic cameras contain an unauthenticated device manipulation vulnerability in their WebSocket implementation that allows attackers to bypass authentication and authorization controls. Attackers can directly modify device configurations, access system information, and potentially initiate denial of service by sending crafted WebSocket messages without authentication."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS"
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-24T19:27:47.524Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "ExploitDB-45539",
"tags": [
"exploit"
],
"url": "https://www.exploit-db.com/exploits/45539"
},
{
"name": "FLIR Systems Official Website",
"tags": [
"product"
],
"url": "https://www.flir.com"
},
{
"name": "Zero Science Lab Disclosure (ZSL-2018-5490)",
"tags": [
"third-party-advisory"
],
"url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2018-5490.php"
}
],
"title": "FLIR Thermal Traffic Cameras V1.01-0bb5b27 Unauthenticated Websocket Device Manipulation",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2018-25140",
"datePublished": "2025-12-24T19:27:47.524Z",
"dateReserved": "2025-12-24T14:28:02.434Z",
"dateUpdated": "2025-12-24T20:26:09.413Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2018-25140 (GCVE-0-2018-25140)
Vulnerability from cvelistv5 – Published: 2025-12-24 19:27 – Updated: 2025-12-24 20:26
VLAI
Title
FLIR Thermal Traffic Cameras V1.01-0bb5b27 Unauthenticated Websocket Device Manipulation
Summary
FLIR thermal traffic cameras contain an unauthenticated device manipulation vulnerability in their WebSocket implementation that allows attackers to bypass authentication and authorization controls. Attackers can directly modify device configurations, access system information, and potentially initiate denial of service by sending crafted WebSocket messages without authentication.
Severity
7.5 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.exploit-db.com/exploits/45539 | exploit |
| https://www.flir.com | product |
| https://www.zeroscience.mk/en/vulnerabilities/ZSL… | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| FLIR Systems, Inc. | Thermal Traffic Cameras |
Affected:
V1.01-0bb5b27
Affected: E1.00.09 Affected: V1.02.P01 Affected: V1.05.P01 Affected: V1.04.P02 Affected: V1.04 Affected: V1.01.P02 Affected: V1.05.P03 Affected: V1.06 Affected: V1.02.P02 |
Date Public
2018-10-06 00:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2018-25140",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-24T20:12:35.313246Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-24T20:26:09.413Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2018-5490.php"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Thermal Traffic Cameras",
"vendor": "FLIR Systems, Inc.",
"versions": [
{
"status": "affected",
"version": "V1.01-0bb5b27"
},
{
"status": "affected",
"version": "E1.00.09"
},
{
"status": "affected",
"version": "V1.02.P01"
},
{
"status": "affected",
"version": "V1.05.P01"
},
{
"status": "affected",
"version": "V1.04.P02"
},
{
"status": "affected",
"version": "V1.04"
},
{
"status": "affected",
"version": "V1.01.P02"
},
{
"status": "affected",
"version": "V1.05.P03"
},
{
"status": "affected",
"version": "V1.06"
},
{
"status": "affected",
"version": "V1.02.P02"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "LiquidWorm as Gjoko Krstic of Zero Science Lab"
}
],
"datePublic": "2018-10-06T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "FLIR thermal traffic cameras contain an unauthenticated device manipulation vulnerability in their WebSocket implementation that allows attackers to bypass authentication and authorization controls. Attackers can directly modify device configurations, access system information, and potentially initiate denial of service by sending crafted WebSocket messages without authentication."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS"
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-24T19:27:47.524Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "ExploitDB-45539",
"tags": [
"exploit"
],
"url": "https://www.exploit-db.com/exploits/45539"
},
{
"name": "FLIR Systems Official Website",
"tags": [
"product"
],
"url": "https://www.flir.com"
},
{
"name": "Zero Science Lab Disclosure (ZSL-2018-5490)",
"tags": [
"third-party-advisory"
],
"url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2018-5490.php"
}
],
"title": "FLIR Thermal Traffic Cameras V1.01-0bb5b27 Unauthenticated Websocket Device Manipulation",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2018-25140",
"datePublished": "2025-12-24T19:27:47.524Z",
"dateReserved": "2025-12-24T14:28:02.434Z",
"dateUpdated": "2025-12-24T20:26:09.413Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}