Search criteria
7 vulnerabilities found for Terra AC wallbox by ABB
JVNDB-2025-000094
Vulnerability from jvndb - Published: 2025-12-05 14:12 - Updated:2025-12-05 14:12
Severity
Summary
Multiple vulnerabilities in ABB Terra AC Wallbox
Details
Terra AC Wallbox provided by ABB contains the following vulnerability.
* Heap-based buffer overflow (CWE-122) - CVE-2025-10504
* Classic buffer overflow (CWE-120) - CVE-2025-12142
* Stack-based buffer overflow (CWE-121) - CVE-2025-12143
Ryo Kato of Panasonic reported this vulnerability to IPA.
JPCERT/CC coordinated with the developer under Information Security Early Warning Partnership.
References
Impacted products
| Vendor | Product | |
|---|---|---|
{
"@rdf:about": "https://jvndb.jvn.jp/en/contents/2025/JVNDB-2025-000094.html",
"dc:date": "2025-12-05T14:12+09:00",
"dcterms:issued": "2025-12-05T14:12+09:00",
"dcterms:modified": "2025-12-05T14:12+09:00",
"description": "Terra AC Wallbox provided by ABB contains the following vulnerability.\r\n\r\n* Heap-based buffer overflow (CWE-122) - CVE-2025-10504\r\n* Classic buffer overflow (CWE-120) - CVE-2025-12142 \r\n* Stack-based buffer overflow (CWE-121) - CVE-2025-12143\r\n\r\nRyo Kato of Panasonic reported this vulnerability to IPA.\r\nJPCERT/CC coordinated with the developer under Information Security Early Warning Partnership.",
"link": "https://jvndb.jvn.jp/en/contents/2025/JVNDB-2025-000094.html",
"sec:cpe": {
"#text": "cpe:/o:abb:terra_ac_wallbox",
"@product": "Terra AC wallbox",
"@vendor": "ABB",
"@version": "2.2"
},
"sec:cvss": {
"@score": "6.1",
"@severity": "Medium",
"@type": "Base",
"@vector": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"@version": "3.0"
},
"sec:identifier": "JVNDB-2025-000094",
"sec:references": [
{
"#text": "https://jvn.jp/en/jp/JVN84024274/index.html",
"@id": "JVN#84024274",
"@source": "JVN"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2025-10504",
"@id": "CVE-2025-10504",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2025-12142",
"@id": "CVE-2025-12142",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2025-12143",
"@id": "CVE-2025-12143",
"@source": "CVE"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-Other",
"@title": "No Mapping(CWE-Other)"
}
],
"title": "Multiple vulnerabilities in ABB Terra AC Wallbox"
}
CVE-2025-12143 (GCVE-0-2025-12143)
Vulnerability from nvd – Published: 2025-11-28 11:59 – Updated: 2025-11-28 14:16
VLAI
Title
Stack Memory Corruption Vulnerability
Summary
Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
Severity
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| ABB | Terra AC wallbox |
Affected:
0 , ≤ 1.8.33
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-12143",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-28T14:16:36.401623Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-28T14:16:43.237Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.8.33",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.\u003cp\u003eThis issue affects Terra AC wallbox: through 1.8.33.\u003c/p\u003e"
}
],
"value": "Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NO",
"Recovery": "AUTOMATIC",
"Safety": "NEGLIGIBLE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "LOW"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-28T11:59:27.485Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A8107\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Stack Memory Corruption Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2025-12143",
"datePublished": "2025-11-28T11:59:27.485Z",
"dateReserved": "2025-10-24T10:40:24.131Z",
"dateUpdated": "2025-11-28T14:16:43.237Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-12142 (GCVE-0-2025-12142)
Vulnerability from nvd – Published: 2025-10-29 12:00 – Updated: 2025-10-29 13:30
VLAI
Title
BSS(Block Started by Symbol) Memory Corruption Vulnerability
Summary
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
Severity
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| ABB | Terra AC wallbox |
Affected:
0 , ≤ 1.8.33
(custom)
|
Date Public
2025-10-27 04:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-12142",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-29T13:25:28.068483Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-29T13:30:33.090Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.8.33",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:abb:terra_ac_wallbox:*:*:*:*:*:*:*:*",
"versionEndIncluding": "1.8.33",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"datePublic": "2025-10-27T04:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability in ABB Terra AC wallbox.\u003cp\u003eThis issue affects Terra AC wallbox: through 1.8.33.\u003c/p\u003e"
}
],
"value": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NO",
"Recovery": "AUTOMATIC",
"Safety": "NEGLIGIBLE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "LOW"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-29T12:00:42.236Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A8107\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "BSS(Block Started by Symbol) Memory Corruption Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2025-12142",
"datePublished": "2025-10-29T12:00:42.236Z",
"dateReserved": "2025-10-24T10:40:22.394Z",
"dateUpdated": "2025-10-29T13:30:33.090Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-10504 (GCVE-0-2025-10504)
Vulnerability from nvd – Published: 2025-09-29 04:12 – Updated: 2025-10-16 06:22
VLAI
Title
Heap Memory Corruption Vulnerability
Summary
Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
Severity
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| ABB | Terra AC wallbox |
Affected:
0 , ≤ 1.8.33
(custom)
|
Date Public
2025-09-28 04:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-10504",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-29T13:05:11.108097Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-29T13:05:14.517Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.8.33",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "ABB acknowledges and thanks Ryo Kato for responsibly disclosing the vulnerabilities and providing valuable input on product improvements."
}
],
"datePublic": "2025-09-28T04:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.\u003cp\u003eThis issue affects Terra AC wallbox: through 1.8.33.\u003c/p\u003e"
}
],
"value": "Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NO",
"Recovery": "AUTOMATIC",
"Safety": "NEGLIGIBLE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "LOW"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-16T06:22:01.300Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A8107\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Heap Memory Corruption Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2025-10504",
"datePublished": "2025-09-29T04:12:18.599Z",
"dateReserved": "2025-09-16T06:05:51.851Z",
"dateUpdated": "2025-10-16T06:22:01.300Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-12143 (GCVE-0-2025-12143)
Vulnerability from cvelistv5 – Published: 2025-11-28 11:59 – Updated: 2025-11-28 14:16
VLAI
Title
Stack Memory Corruption Vulnerability
Summary
Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
Severity
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| ABB | Terra AC wallbox |
Affected:
0 , ≤ 1.8.33
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-12143",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-28T14:16:36.401623Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-28T14:16:43.237Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.8.33",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.\u003cp\u003eThis issue affects Terra AC wallbox: through 1.8.33.\u003c/p\u003e"
}
],
"value": "Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NO",
"Recovery": "AUTOMATIC",
"Safety": "NEGLIGIBLE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "LOW"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-28T11:59:27.485Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A8107\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Stack Memory Corruption Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2025-12143",
"datePublished": "2025-11-28T11:59:27.485Z",
"dateReserved": "2025-10-24T10:40:24.131Z",
"dateUpdated": "2025-11-28T14:16:43.237Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-12142 (GCVE-0-2025-12142)
Vulnerability from cvelistv5 – Published: 2025-10-29 12:00 – Updated: 2025-10-29 13:30
VLAI
Title
BSS(Block Started by Symbol) Memory Corruption Vulnerability
Summary
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
Severity
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| ABB | Terra AC wallbox |
Affected:
0 , ≤ 1.8.33
(custom)
|
Date Public
2025-10-27 04:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-12142",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-29T13:25:28.068483Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-29T13:30:33.090Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.8.33",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:abb:terra_ac_wallbox:*:*:*:*:*:*:*:*",
"versionEndIncluding": "1.8.33",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"datePublic": "2025-10-27T04:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability in ABB Terra AC wallbox.\u003cp\u003eThis issue affects Terra AC wallbox: through 1.8.33.\u003c/p\u003e"
}
],
"value": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NO",
"Recovery": "AUTOMATIC",
"Safety": "NEGLIGIBLE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "LOW"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-29T12:00:42.236Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A8107\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "BSS(Block Started by Symbol) Memory Corruption Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2025-12142",
"datePublished": "2025-10-29T12:00:42.236Z",
"dateReserved": "2025-10-24T10:40:22.394Z",
"dateUpdated": "2025-10-29T13:30:33.090Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-10504 (GCVE-0-2025-10504)
Vulnerability from cvelistv5 – Published: 2025-09-29 04:12 – Updated: 2025-10-16 06:22
VLAI
Title
Heap Memory Corruption Vulnerability
Summary
Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
Severity
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| ABB | Terra AC wallbox |
Affected:
0 , ≤ 1.8.33
(custom)
|
Date Public
2025-09-28 04:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-10504",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-29T13:05:11.108097Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-29T13:05:14.517Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.8.33",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "ABB acknowledges and thanks Ryo Kato for responsibly disclosing the vulnerabilities and providing valuable input on product improvements."
}
],
"datePublic": "2025-09-28T04:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.\u003cp\u003eThis issue affects Terra AC wallbox: through 1.8.33.\u003c/p\u003e"
}
],
"value": "Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NO",
"Recovery": "AUTOMATIC",
"Safety": "NEGLIGIBLE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "LOW"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-16T06:22:01.300Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A8107\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Heap Memory Corruption Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2025-10504",
"datePublished": "2025-09-29T04:12:18.599Z",
"dateReserved": "2025-09-16T06:05:51.851Z",
"dateUpdated": "2025-10-16T06:22:01.300Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}