Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for Teamcenter Visualization V2506 by Siemens

    CVE-2025-40945 (GCVE-0-2025-40945)

    Vulnerability from nvd – Published: 2026-07-14 09:19 – Updated: 2026-07-14 12:16
    VLAI
    Summary
    A vulnerability has been identified in COMOS V10.4.5 (All versions < V10.4.5.0.2), COMOS V10.6 (All versions < V10.6.1), Designcenter NX (All versions < V2512.7000), Simcenter 3D (All versions < V2512.7000), Simcenter Femap V2506 (All versions < V2506.0003), Simcenter Femap V2512 (All versions < V2512.0002), Simcenter Nastran (All versions < V2606), Simcenter STAR-CCM+ (All versions < V2606), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Teamcenter Visualization V2412 (All versions < V2412.0012), Teamcenter Visualization V2506 (All versions < V2506.0009), Teamcenter Visualization V2512 (All versions < V2512.2605), Tecnomatix Plant Simulation V2404 (All versions < V2404.0022), Tecnomatix Plant Simulation V2504 (All versions < V2504.0010), Tecnomatix Process Simulate (All versions < V2606). Untrusted search path in IAM Client SDK may allow an authenticated user to potentially enable escalation of privilege via local access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Siemens COMOS V10.4.5 Affected: 0 , < V10.4.5.0.2 (custom)
    Create a notification for this product.
    Siemens COMOS V10.6 Affected: 0 , < V10.6.1 (custom)
    Create a notification for this product.
    Siemens Designcenter NX Affected: 0 , < V2512.7000 (custom)
    Create a notification for this product.
    Siemens Simcenter 3D Affected: 0 , < V2512.7000 (custom)
    Create a notification for this product.
    Siemens Simcenter Femap V2506 Affected: 0 , < V2506.0003 (custom)
    Create a notification for this product.
    Siemens Simcenter Femap V2512 Affected: 0 , < V2512.0002 (custom)
    Create a notification for this product.
    Siemens Simcenter Nastran Affected: 0 , < V2606 (custom)
    Create a notification for this product.
    Siemens Simcenter STAR-CCM+ Affected: 0 , < V2606 (custom)
    Create a notification for this product.
    Siemens Solid Edge SE2025 Affected: 0 , < V225.0 Update 13 (custom)
    Create a notification for this product.
    Siemens Solid Edge SE2026 Affected: 0 , < V226.0 Update 04 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V2412 Affected: 0 , < V2412.0012 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V2506 Affected: 0 , < V2506.0009 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V2512 Affected: 0 , < V2512.2605 (custom)
    Create a notification for this product.
    Siemens Tecnomatix Plant Simulation V2404 Affected: 0 , < V2404.0022 (custom)
    Create a notification for this product.
    Siemens Tecnomatix Plant Simulation V2504 Affected: 0 , < V2504.0010 (custom)
    Create a notification for this product.
    Siemens Tecnomatix Process Simulate Affected: 0 , < V2606 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-40945",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-14T12:16:50.783446Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-14T12:16:59.871Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "COMOS V10.4.5",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V10.4.5.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "COMOS V10.6",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V10.6.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Designcenter NX",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2512.7000",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter 3D",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2512.7000",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter Femap V2506",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2506.0003",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter Femap V2512",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2512.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter Nastran",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2606",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter STAR-CCM+",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2606",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Solid Edge SE2025",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V225.0 Update 13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Solid Edge SE2026",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V226.0 Update 04",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0012",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2506",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2506.0009",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2512",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2512.2605",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0022",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2504",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2504.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Process Simulate",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2606",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in COMOS V10.4.5 (All versions \u003c V10.4.5.0.2), COMOS V10.6 (All versions \u003c V10.6.1), Designcenter NX (All versions \u003c V2512.7000), Simcenter 3D (All versions \u003c V2512.7000), Simcenter Femap V2506 (All versions \u003c V2506.0003), Simcenter Femap V2512 (All versions \u003c V2512.0002), Simcenter Nastran (All versions \u003c V2606), Simcenter STAR-CCM+ (All versions \u003c V2606), Solid Edge SE2025 (All versions \u003c V225.0 Update 13), Solid Edge SE2026 (All versions \u003c V226.0 Update 04), Teamcenter Visualization V2412 (All versions \u003c V2412.0012), Teamcenter Visualization V2506 (All versions \u003c V2506.0009), Teamcenter Visualization V2512 (All versions \u003c V2512.2605), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0022), Tecnomatix Plant Simulation V2504 (All versions \u003c V2504.0010), Tecnomatix Process Simulate (All versions \u003c V2606). Untrusted search path in IAM Client SDK may allow an authenticated user to potentially enable escalation of privilege via local access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-426",
                  "description": "CWE-426: Untrusted Search Path",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-14T09:19:08.857Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-288252.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-40945",
        "datePublished": "2026-07-14T09:19:08.857Z",
        "dateReserved": "2025-04-16T09:06:15.879Z",
        "dateUpdated": "2026-07-14T12:16:59.871Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-40945 (GCVE-0-2025-40945)

    Vulnerability from cvelistv5 – Published: 2026-07-14 09:19 – Updated: 2026-07-14 12:16
    VLAI
    Summary
    A vulnerability has been identified in COMOS V10.4.5 (All versions < V10.4.5.0.2), COMOS V10.6 (All versions < V10.6.1), Designcenter NX (All versions < V2512.7000), Simcenter 3D (All versions < V2512.7000), Simcenter Femap V2506 (All versions < V2506.0003), Simcenter Femap V2512 (All versions < V2512.0002), Simcenter Nastran (All versions < V2606), Simcenter STAR-CCM+ (All versions < V2606), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Teamcenter Visualization V2412 (All versions < V2412.0012), Teamcenter Visualization V2506 (All versions < V2506.0009), Teamcenter Visualization V2512 (All versions < V2512.2605), Tecnomatix Plant Simulation V2404 (All versions < V2404.0022), Tecnomatix Plant Simulation V2504 (All versions < V2504.0010), Tecnomatix Process Simulate (All versions < V2606). Untrusted search path in IAM Client SDK may allow an authenticated user to potentially enable escalation of privilege via local access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Siemens COMOS V10.4.5 Affected: 0 , < V10.4.5.0.2 (custom)
    Create a notification for this product.
    Siemens COMOS V10.6 Affected: 0 , < V10.6.1 (custom)
    Create a notification for this product.
    Siemens Designcenter NX Affected: 0 , < V2512.7000 (custom)
    Create a notification for this product.
    Siemens Simcenter 3D Affected: 0 , < V2512.7000 (custom)
    Create a notification for this product.
    Siemens Simcenter Femap V2506 Affected: 0 , < V2506.0003 (custom)
    Create a notification for this product.
    Siemens Simcenter Femap V2512 Affected: 0 , < V2512.0002 (custom)
    Create a notification for this product.
    Siemens Simcenter Nastran Affected: 0 , < V2606 (custom)
    Create a notification for this product.
    Siemens Simcenter STAR-CCM+ Affected: 0 , < V2606 (custom)
    Create a notification for this product.
    Siemens Solid Edge SE2025 Affected: 0 , < V225.0 Update 13 (custom)
    Create a notification for this product.
    Siemens Solid Edge SE2026 Affected: 0 , < V226.0 Update 04 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V2412 Affected: 0 , < V2412.0012 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V2506 Affected: 0 , < V2506.0009 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V2512 Affected: 0 , < V2512.2605 (custom)
    Create a notification for this product.
    Siemens Tecnomatix Plant Simulation V2404 Affected: 0 , < V2404.0022 (custom)
    Create a notification for this product.
    Siemens Tecnomatix Plant Simulation V2504 Affected: 0 , < V2504.0010 (custom)
    Create a notification for this product.
    Siemens Tecnomatix Process Simulate Affected: 0 , < V2606 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-40945",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-14T12:16:50.783446Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-14T12:16:59.871Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "COMOS V10.4.5",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V10.4.5.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "COMOS V10.6",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V10.6.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Designcenter NX",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2512.7000",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter 3D",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2512.7000",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter Femap V2506",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2506.0003",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter Femap V2512",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2512.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter Nastran",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2606",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter STAR-CCM+",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2606",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Solid Edge SE2025",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V225.0 Update 13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Solid Edge SE2026",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V226.0 Update 04",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0012",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2506",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2506.0009",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2512",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2512.2605",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0022",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2504",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2504.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Process Simulate",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2606",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in COMOS V10.4.5 (All versions \u003c V10.4.5.0.2), COMOS V10.6 (All versions \u003c V10.6.1), Designcenter NX (All versions \u003c V2512.7000), Simcenter 3D (All versions \u003c V2512.7000), Simcenter Femap V2506 (All versions \u003c V2506.0003), Simcenter Femap V2512 (All versions \u003c V2512.0002), Simcenter Nastran (All versions \u003c V2606), Simcenter STAR-CCM+ (All versions \u003c V2606), Solid Edge SE2025 (All versions \u003c V225.0 Update 13), Solid Edge SE2026 (All versions \u003c V226.0 Update 04), Teamcenter Visualization V2412 (All versions \u003c V2412.0012), Teamcenter Visualization V2506 (All versions \u003c V2506.0009), Teamcenter Visualization V2512 (All versions \u003c V2512.2605), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0022), Tecnomatix Plant Simulation V2504 (All versions \u003c V2504.0010), Tecnomatix Process Simulate (All versions \u003c V2606). Untrusted search path in IAM Client SDK may allow an authenticated user to potentially enable escalation of privilege via local access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-426",
                  "description": "CWE-426: Untrusted Search Path",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-14T09:19:08.857Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-288252.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-40945",
        "datePublished": "2026-07-14T09:19:08.857Z",
        "dateReserved": "2025-04-16T09:06:15.879Z",
        "dateUpdated": "2026-07-14T12:16:59.871Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }