Search
Find a vulnerability
Search criteria
20 vulnerabilities found for TMS7 by Toptech Systems
CVE-2026-72510 (GCVE-0-2026-72510)
Vulnerability from nvd – Published: 2026-09-29 21:28 – Updated: 2026-09-29 21:28
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT SQL Injection
Summary
The "supplier_no" parameter used in the business allocation search feature is vulnerable to time-based blind SQL injection.
Severity
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The \"supplier_no\" parameter used in the business allocation search feature is vulnerable to time-based blind SQL injection."
}
],
"value": "The \"supplier_no\" parameter used in the business allocation search feature is vulnerable to time-based blind SQL injection."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:28:26.762Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT SQL Injection",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-72510",
"datePublished": "2026-09-29T21:28:26.762Z",
"dateReserved": "2026-08-10T17:31:09.979Z",
"dateUpdated": "2026-09-29T21:28:26.762Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-72507 (GCVE-0-2026-72507)
Vulnerability from nvd – Published: 2026-09-29 21:36 – Updated: 2026-09-29 21:36
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT SQL Injection
Summary
The "reportType" parameter in the product summary report feature within the balancing reports section is susceptible to a time-based blind SQL injection vulnerability.
Severity
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The \"reportType\" parameter in the product summary report feature within the balancing reports section is susceptible to a time-based blind SQL injection vulnerability."
}
],
"value": "The \"reportType\" parameter in the product summary report feature within the balancing reports section is susceptible to a time-based blind SQL injection vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:36:53.928Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT SQL Injection",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-72507",
"datePublished": "2026-09-29T21:36:53.928Z",
"dateReserved": "2026-08-10T17:31:09.965Z",
"dateUpdated": "2026-09-29T21:36:53.928Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-71379 (GCVE-0-2026-71379)
Vulnerability from nvd – Published: 2026-09-29 21:23 – Updated: 2026-09-29 21:23
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT Files or Directories Accessible to External Parties
Summary
The file export endpoint allows any unauthenticated attacker to export arbitrary database tables by sending a crafted POST request.
Severity
10 (Critical)
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The file export endpoint allows any unauthenticated attacker to export arbitrary database tables by sending a crafted POST request."
}
],
"value": "The file export endpoint allows any unauthenticated attacker to export arbitrary database tables by sending a crafted POST request."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-552",
"description": "CWE-552",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:23:25.412Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT Files or Directories Accessible to External Parties",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-71379",
"datePublished": "2026-09-29T21:23:25.412Z",
"dateReserved": "2026-08-10T17:31:09.986Z",
"dateUpdated": "2026-09-29T21:23:25.412Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-71302 (GCVE-0-2026-71302)
Vulnerability from nvd – Published: 2026-09-29 21:41 – Updated: 2026-09-29 21:41
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT Session Fixation
Summary
The application accepts user-supplied session identifiers and does not regenerate the session ID after authentication. This allows an attacker to predefine a session ID and reuse it after victim authentication, resulting in session takeover.
Severity
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The application accepts user-supplied session identifiers and does not regenerate the session ID after authentication. This allows an attacker to predefine a session ID and reuse it after victim authentication, resulting in session takeover."
}
],
"value": "The application accepts user-supplied session identifiers and does not regenerate the session ID after authentication. This allows an attacker to predefine a session ID and reuse it after victim authentication, resulting in session takeover."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:A/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-384",
"description": "CWE-384",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:41:11.253Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT Session Fixation",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-71302",
"datePublished": "2026-09-29T21:41:11.253Z",
"dateReserved": "2026-08-10T17:31:09.961Z",
"dateUpdated": "2026-09-29T21:41:11.253Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-71189 (GCVE-0-2026-71189)
Vulnerability from nvd – Published: 2026-09-29 21:46 – Updated: 2026-09-29 21:46
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT Cross-site Scripting
Summary
An attacker can construct a request that, if issued by another application user, will cause JavaScript code supplied by the attacker to execute within the user's browser in the context of that user's session with the application.
Severity
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An attacker can construct a request that, if issued by another application user, will cause JavaScript code supplied by the attacker to execute within the user\u0027s browser in the context of that user\u0027s session with the application."
}
],
"value": "An attacker can construct a request that, if issued by another application user, will cause JavaScript code supplied by the attacker to execute within the user\u0027s browser in the context of that user\u0027s session with the application."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:46:48.138Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT Cross-site Scripting",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-71189",
"datePublished": "2026-09-29T21:46:48.138Z",
"dateReserved": "2026-08-10T17:31:09.953Z",
"dateUpdated": "2026-09-29T21:46:48.138Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-70356 (GCVE-0-2026-70356)
Vulnerability from nvd – Published: 2026-09-29 21:26 – Updated: 2026-09-29 21:26
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT Unrestricted Upload of File with Dangerous Type
Summary
The TMS file upload endpoint fails to enforce server-side file type restrictions, allowing an attacker to upload and execute arbitrary PHP files on the web server.
Severity
9.1 (Critical)
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The TMS file upload endpoint fails to enforce server-side file type restrictions, allowing an attacker to upload and execute arbitrary PHP files on the web server."
}
],
"value": "The TMS file upload endpoint fails to enforce server-side file type restrictions, allowing an attacker to upload and execute arbitrary PHP files on the web server."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:26:22.603Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT Unrestricted Upload of File with Dangerous Type",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-70356",
"datePublished": "2026-09-29T21:26:22.603Z",
"dateReserved": "2026-08-10T17:31:09.982Z",
"dateUpdated": "2026-09-29T21:26:22.603Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-69662 (GCVE-0-2026-69662)
Vulnerability from nvd – Published: 2026-09-29 21:44 – Updated: 2026-09-29 21:44
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT Eval Injection
Summary
The application uses unsafe functions that allow execution of inline scripts and string evaluation functions.
Severity
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The application uses unsafe functions that allow execution of inline scripts and string evaluation functions."
}
],
"value": "The application uses unsafe functions that allow execution of inline scripts and string evaluation functions."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 2.1,
"baseSeverity": "LOW",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-95",
"description": "CWE-95",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:44:07.903Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT Eval Injection",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-69662",
"datePublished": "2026-09-29T21:44:07.903Z",
"dateReserved": "2026-08-10T17:31:09.958Z",
"dateUpdated": "2026-09-29T21:44:07.903Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-68954 (GCVE-0-2026-68954)
Vulnerability from nvd – Published: 2026-09-29 21:32 – Updated: 2026-09-29 21:32
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT SQL Injection
Summary
The "pattern" parameter used in search function in the home page of the TMS application is vulnerable to time-based blind SQL injection vulnerability.
Severity
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The \"pattern\" parameter used in search function in the home page of the TMS application is vulnerable to time-based blind SQL injection vulnerability."
}
],
"value": "The \"pattern\" parameter used in search function in the home page of the TMS application is vulnerable to time-based blind SQL injection vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:32:05.984Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT SQL Injection",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-68954",
"datePublished": "2026-09-29T21:32:05.984Z",
"dateReserved": "2026-08-10T17:31:09.972Z",
"dateUpdated": "2026-09-29T21:32:05.984Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-68068 (GCVE-0-2026-68068)
Vulnerability from nvd – Published: 2026-09-29 21:33 – Updated: 2026-09-29 21:33
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT SQL Injection
Summary
The "screenID" parameter in the electronic transaction queue viewer feature within the manual transactions section is susceptible to a time-based blind SQL injection vulnerability.
Severity
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The \"screenID\" parameter in the electronic transaction queue viewer feature within the manual transactions section is susceptible to a time-based blind SQL injection vulnerability."
}
],
"value": "The \"screenID\" parameter in the electronic transaction queue viewer feature within the manual transactions section is susceptible to a time-based blind SQL injection vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:33:47.332Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT SQL Injection",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-68068",
"datePublished": "2026-09-29T21:33:47.332Z",
"dateReserved": "2026-08-10T17:31:09.969Z",
"dateUpdated": "2026-09-29T21:33:47.332Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-63713 (GCVE-0-2026-63713)
Vulnerability from nvd – Published: 2026-09-29 21:30 – Updated: 2026-09-29 21:30
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT SQL Injection
Summary
The "search" parameter in the view audit logs feature within the utilities section is susceptible to a time-based blind SQL injection vulnerability.
Severity
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The \"search\" parameter in the view audit logs feature within the utilities section is susceptible to a time-based blind SQL injection vulnerability."
}
],
"value": "The \"search\" parameter in the view audit logs feature within the utilities section is susceptible to a time-based blind SQL injection vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:30:32.531Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT SQL Injection",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-63713",
"datePublished": "2026-09-29T21:30:32.531Z",
"dateReserved": "2026-08-10T17:31:09.976Z",
"dateUpdated": "2026-09-29T21:30:32.531Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-71189 (GCVE-0-2026-71189)
Vulnerability from cvelistv5 – Published: 2026-09-29 21:46 – Updated: 2026-09-29 21:46
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT Cross-site Scripting
Summary
An attacker can construct a request that, if issued by another application user, will cause JavaScript code supplied by the attacker to execute within the user's browser in the context of that user's session with the application.
Severity
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An attacker can construct a request that, if issued by another application user, will cause JavaScript code supplied by the attacker to execute within the user\u0027s browser in the context of that user\u0027s session with the application."
}
],
"value": "An attacker can construct a request that, if issued by another application user, will cause JavaScript code supplied by the attacker to execute within the user\u0027s browser in the context of that user\u0027s session with the application."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:46:48.138Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT Cross-site Scripting",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-71189",
"datePublished": "2026-09-29T21:46:48.138Z",
"dateReserved": "2026-08-10T17:31:09.953Z",
"dateUpdated": "2026-09-29T21:46:48.138Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-69662 (GCVE-0-2026-69662)
Vulnerability from cvelistv5 – Published: 2026-09-29 21:44 – Updated: 2026-09-29 21:44
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT Eval Injection
Summary
The application uses unsafe functions that allow execution of inline scripts and string evaluation functions.
Severity
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The application uses unsafe functions that allow execution of inline scripts and string evaluation functions."
}
],
"value": "The application uses unsafe functions that allow execution of inline scripts and string evaluation functions."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 2.1,
"baseSeverity": "LOW",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-95",
"description": "CWE-95",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:44:07.903Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT Eval Injection",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-69662",
"datePublished": "2026-09-29T21:44:07.903Z",
"dateReserved": "2026-08-10T17:31:09.958Z",
"dateUpdated": "2026-09-29T21:44:07.903Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-71302 (GCVE-0-2026-71302)
Vulnerability from cvelistv5 – Published: 2026-09-29 21:41 – Updated: 2026-09-29 21:41
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT Session Fixation
Summary
The application accepts user-supplied session identifiers and does not regenerate the session ID after authentication. This allows an attacker to predefine a session ID and reuse it after victim authentication, resulting in session takeover.
Severity
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The application accepts user-supplied session identifiers and does not regenerate the session ID after authentication. This allows an attacker to predefine a session ID and reuse it after victim authentication, resulting in session takeover."
}
],
"value": "The application accepts user-supplied session identifiers and does not regenerate the session ID after authentication. This allows an attacker to predefine a session ID and reuse it after victim authentication, resulting in session takeover."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:A/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-384",
"description": "CWE-384",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:41:11.253Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT Session Fixation",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-71302",
"datePublished": "2026-09-29T21:41:11.253Z",
"dateReserved": "2026-08-10T17:31:09.961Z",
"dateUpdated": "2026-09-29T21:41:11.253Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-72507 (GCVE-0-2026-72507)
Vulnerability from cvelistv5 – Published: 2026-09-29 21:36 – Updated: 2026-09-29 21:36
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT SQL Injection
Summary
The "reportType" parameter in the product summary report feature within the balancing reports section is susceptible to a time-based blind SQL injection vulnerability.
Severity
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The \"reportType\" parameter in the product summary report feature within the balancing reports section is susceptible to a time-based blind SQL injection vulnerability."
}
],
"value": "The \"reportType\" parameter in the product summary report feature within the balancing reports section is susceptible to a time-based blind SQL injection vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:36:53.928Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT SQL Injection",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-72507",
"datePublished": "2026-09-29T21:36:53.928Z",
"dateReserved": "2026-08-10T17:31:09.965Z",
"dateUpdated": "2026-09-29T21:36:53.928Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-68068 (GCVE-0-2026-68068)
Vulnerability from cvelistv5 – Published: 2026-09-29 21:33 – Updated: 2026-09-29 21:33
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT SQL Injection
Summary
The "screenID" parameter in the electronic transaction queue viewer feature within the manual transactions section is susceptible to a time-based blind SQL injection vulnerability.
Severity
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The \"screenID\" parameter in the electronic transaction queue viewer feature within the manual transactions section is susceptible to a time-based blind SQL injection vulnerability."
}
],
"value": "The \"screenID\" parameter in the electronic transaction queue viewer feature within the manual transactions section is susceptible to a time-based blind SQL injection vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:33:47.332Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT SQL Injection",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-68068",
"datePublished": "2026-09-29T21:33:47.332Z",
"dateReserved": "2026-08-10T17:31:09.969Z",
"dateUpdated": "2026-09-29T21:33:47.332Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-68954 (GCVE-0-2026-68954)
Vulnerability from cvelistv5 – Published: 2026-09-29 21:32 – Updated: 2026-09-29 21:32
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT SQL Injection
Summary
The "pattern" parameter used in search function in the home page of the TMS application is vulnerable to time-based blind SQL injection vulnerability.
Severity
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The \"pattern\" parameter used in search function in the home page of the TMS application is vulnerable to time-based blind SQL injection vulnerability."
}
],
"value": "The \"pattern\" parameter used in search function in the home page of the TMS application is vulnerable to time-based blind SQL injection vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:32:05.984Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT SQL Injection",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-68954",
"datePublished": "2026-09-29T21:32:05.984Z",
"dateReserved": "2026-08-10T17:31:09.972Z",
"dateUpdated": "2026-09-29T21:32:05.984Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-63713 (GCVE-0-2026-63713)
Vulnerability from cvelistv5 – Published: 2026-09-29 21:30 – Updated: 2026-09-29 21:30
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT SQL Injection
Summary
The "search" parameter in the view audit logs feature within the utilities section is susceptible to a time-based blind SQL injection vulnerability.
Severity
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The \"search\" parameter in the view audit logs feature within the utilities section is susceptible to a time-based blind SQL injection vulnerability."
}
],
"value": "The \"search\" parameter in the view audit logs feature within the utilities section is susceptible to a time-based blind SQL injection vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:30:32.531Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT SQL Injection",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-63713",
"datePublished": "2026-09-29T21:30:32.531Z",
"dateReserved": "2026-08-10T17:31:09.976Z",
"dateUpdated": "2026-09-29T21:30:32.531Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-72510 (GCVE-0-2026-72510)
Vulnerability from cvelistv5 – Published: 2026-09-29 21:28 – Updated: 2026-09-29 21:28
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT SQL Injection
Summary
The "supplier_no" parameter used in the business allocation search feature is vulnerable to time-based blind SQL injection.
Severity
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The \"supplier_no\" parameter used in the business allocation search feature is vulnerable to time-based blind SQL injection."
}
],
"value": "The \"supplier_no\" parameter used in the business allocation search feature is vulnerable to time-based blind SQL injection."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:28:26.762Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT SQL Injection",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-72510",
"datePublished": "2026-09-29T21:28:26.762Z",
"dateReserved": "2026-08-10T17:31:09.979Z",
"dateUpdated": "2026-09-29T21:28:26.762Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-70356 (GCVE-0-2026-70356)
Vulnerability from cvelistv5 – Published: 2026-09-29 21:26 – Updated: 2026-09-29 21:26
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT Unrestricted Upload of File with Dangerous Type
Summary
The TMS file upload endpoint fails to enforce server-side file type restrictions, allowing an attacker to upload and execute arbitrary PHP files on the web server.
Severity
9.1 (Critical)
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The TMS file upload endpoint fails to enforce server-side file type restrictions, allowing an attacker to upload and execute arbitrary PHP files on the web server."
}
],
"value": "The TMS file upload endpoint fails to enforce server-side file type restrictions, allowing an attacker to upload and execute arbitrary PHP files on the web server."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:26:22.603Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT Unrestricted Upload of File with Dangerous Type",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-70356",
"datePublished": "2026-09-29T21:26:22.603Z",
"dateReserved": "2026-08-10T17:31:09.982Z",
"dateUpdated": "2026-09-29T21:26:22.603Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-71379 (GCVE-0-2026-71379)
Vulnerability from cvelistv5 – Published: 2026-09-29 21:23 – Updated: 2026-09-29 21:23
VLAI
EPSS
VEX
Title
Toptech TMS7 and TopHAT Files or Directories Accessible to External Parties
Summary
The file export endpoint allows any unauthenticated attacker to export arbitrary database tables by sending a crafted POST request.
Severity
10 (Critical)
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Toptech Systems | TMS7 |
Affected:
7.6.3
Unaffected: 7.8 |
|
| Toptech Systems | TopHAT |
Affected:
7.6.3
Unaffected: 7.8 |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TMS7",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TopHAT",
"vendor": "Toptech Systems",
"versions": [
{
"status": "affected",
"version": "7.6.3"
},
{
"status": "unaffected",
"version": "7.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The file export endpoint allows any unauthenticated attacker to export arbitrary database tables by sending a crafted POST request."
}
],
"value": "The file export endpoint allows any unauthenticated attacker to export arbitrary database tables by sending a crafted POST request."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-552",
"description": "CWE-552",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T21:23:25.412Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\u003cbr\u003e\u003ca href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\"\u003ehttps://www.toptech.com/blog/tms7-version-7-8-strengthens-security\u003c/a\u003e"
}
],
"value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
}
],
"source": {
"advisory": "ICSA-26-272-02",
"discovery": "EXTERNAL"
},
"title": "Toptech TMS7 and TopHAT Files or Directories Accessible to External Parties",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-71379",
"datePublished": "2026-09-29T21:23:25.412Z",
"dateReserved": "2026-08-10T17:31:09.986Z",
"dateUpdated": "2026-09-29T21:23:25.412Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}