    2 vulnerabilities found for System x IMM2 by Lenovo Group Ltd.

    CVE-2018-9068 (GCVE-0-2018-9068)

    Vulnerability from nvd – Published: 2018-07-26 19:00 – Updated: 2024-09-17 03:38
    VLAI
    Summary
    The IMM2 First Failure Data Capture function collects management module logs and diagnostic information when a hardware error is detected. This information is made available for download through an SFTP server hosted on the IMM2 management network interface. In versions earlier than 4.90 for Lenovo System x and earlier than 6.80 for IBM System x, the credentials to access the SFTP server are hard-coded and described in the IMM2 documentation, allowing an attacker with management network access to obtain the collected FFDC data. After applying the update, the IMM2 will create random SFTP credentials for use with OneCLI.
    Severity
    No CVSS data available.
    CWE
    • Information disclosure
    Assigner
    References
    Impacted products
    Vendor Product Version
    Lenovo Group Ltd. System x IMM2 Affected: firmware versions earlier than 4.90
    Create a notification for this product.
    IBM Corporation System x IMM2 Affected: firmware versions earlier than 6.80
    Create a notification for this product.
    Date Public
    2018-07-26 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T07:17:50.331Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/solutions/LEN-20227"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "System x IMM2",
              "vendor": "Lenovo Group Ltd.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware versions earlier than 4.90"
                }
              ]
            },
            {
              "product": "System x IMM2",
              "vendor": "IBM Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware versions earlier than 6.80"
                }
              ]
            }
          ],
          "datePublic": "2018-07-26T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The IMM2 First Failure Data Capture function collects management module logs and diagnostic information when a hardware error is detected. This information is made available for download through an SFTP server hosted on the IMM2 management network interface. In versions earlier than 4.90 for Lenovo System x and earlier than 6.80 for IBM System x, the credentials to access the SFTP server are hard-coded and described in the IMM2 documentation, allowing an attacker with management network access to obtain the collected FFDC data. After applying the update, the IMM2 will create random SFTP credentials for use with OneCLI."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Information disclosure",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-07-26T18:57:01.000Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://support.lenovo.com/us/en/solutions/LEN-20227"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@lenovo.com",
              "DATE_PUBLIC": "2018-07-26T00:00:00",
              "ID": "CVE-2018-9068",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "System x IMM2",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "firmware versions earlier than 4.90"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Lenovo Group Ltd."
                  },
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "System x IMM2",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "firmware versions earlier than 6.80"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "IBM Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The IMM2 First Failure Data Capture function collects management module logs and diagnostic information when a hardware error is detected. This information is made available for download through an SFTP server hosted on the IMM2 management network interface. In versions earlier than 4.90 for Lenovo System x and earlier than 6.80 for IBM System x, the credentials to access the SFTP server are hard-coded and described in the IMM2 documentation, allowing an attacker with management network access to obtain the collected FFDC data. After applying the update, the IMM2 will create random SFTP credentials for use with OneCLI."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Information disclosure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.lenovo.com/us/en/solutions/LEN-20227",
                  "refsource": "CONFIRM",
                  "url": "https://support.lenovo.com/us/en/solutions/LEN-20227"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2018-9068",
        "datePublished": "2018-07-26T19:00:00.000Z",
        "dateReserved": "2018-03-27T00:00:00.000Z",
        "dateUpdated": "2024-09-17T03:38:52.294Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-9068 (GCVE-0-2018-9068)

    Vulnerability from cvelistv5 – Published: 2018-07-26 19:00 – Updated: 2024-09-17 03:38
    VLAI
    Summary
    The IMM2 First Failure Data Capture function collects management module logs and diagnostic information when a hardware error is detected. This information is made available for download through an SFTP server hosted on the IMM2 management network interface. In versions earlier than 4.90 for Lenovo System x and earlier than 6.80 for IBM System x, the credentials to access the SFTP server are hard-coded and described in the IMM2 documentation, allowing an attacker with management network access to obtain the collected FFDC data. After applying the update, the IMM2 will create random SFTP credentials for use with OneCLI.
    Severity
    No CVSS data available.
    CWE
    • Information disclosure
    Assigner
    References
    Impacted products
    Vendor Product Version
    Lenovo Group Ltd. System x IMM2 Affected: firmware versions earlier than 4.90
    Create a notification for this product.
    IBM Corporation System x IMM2 Affected: firmware versions earlier than 6.80
    Create a notification for this product.
    Date Public
    2018-07-26 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T07:17:50.331Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/solutions/LEN-20227"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "System x IMM2",
              "vendor": "Lenovo Group Ltd.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware versions earlier than 4.90"
                }
              ]
            },
            {
              "product": "System x IMM2",
              "vendor": "IBM Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware versions earlier than 6.80"
                }
              ]
            }
          ],
          "datePublic": "2018-07-26T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The IMM2 First Failure Data Capture function collects management module logs and diagnostic information when a hardware error is detected. This information is made available for download through an SFTP server hosted on the IMM2 management network interface. In versions earlier than 4.90 for Lenovo System x and earlier than 6.80 for IBM System x, the credentials to access the SFTP server are hard-coded and described in the IMM2 documentation, allowing an attacker with management network access to obtain the collected FFDC data. After applying the update, the IMM2 will create random SFTP credentials for use with OneCLI."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Information disclosure",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-07-26T18:57:01.000Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://support.lenovo.com/us/en/solutions/LEN-20227"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@lenovo.com",
              "DATE_PUBLIC": "2018-07-26T00:00:00",
              "ID": "CVE-2018-9068",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "System x IMM2",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "firmware versions earlier than 4.90"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Lenovo Group Ltd."
                  },
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "System x IMM2",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "firmware versions earlier than 6.80"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "IBM Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The IMM2 First Failure Data Capture function collects management module logs and diagnostic information when a hardware error is detected. This information is made available for download through an SFTP server hosted on the IMM2 management network interface. In versions earlier than 4.90 for Lenovo System x and earlier than 6.80 for IBM System x, the credentials to access the SFTP server are hard-coded and described in the IMM2 documentation, allowing an attacker with management network access to obtain the collected FFDC data. After applying the update, the IMM2 will create random SFTP credentials for use with OneCLI."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Information disclosure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.lenovo.com/us/en/solutions/LEN-20227",
                  "refsource": "CONFIRM",
                  "url": "https://support.lenovo.com/us/en/solutions/LEN-20227"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2018-9068",
        "datePublished": "2018-07-26T19:00:00.000Z",
        "dateReserved": "2018-03-27T00:00:00.000Z",
        "dateUpdated": "2024-09-17T03:38:52.294Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }