    CVE-2019-25276 (GCVE-0-2019-25276)

    Vulnerability from nvd – Published: 2026-02-04 23:15 – Updated: 2026-02-05 17:24
    VLAI
    Title
    Studio 5000 Logix Designer 30.01.00 - 'FactoryTalk Activation Service' Unquoted Service Path
    Summary
    Studio 5000 Logix Designer 30.01.00 contains an unquoted service path vulnerability in the FactoryTalk Activation Service that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\Program Files (x86)\Rockwell Software\FactoryTalk Activation\ to inject malicious code that would execute with LocalSystem permissions.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-428 - Unquoted Search Path or Element
    Assigner
    Impacted products
    Date Public
    2019-11-18 00:00
    Credits
    Luis Martinez
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2019-25276",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-05T17:24:42.525254Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-05T17:24:48.227Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Studio",
              "vendor": "Rockwellautomation",
              "versions": [
                {
                  "status": "affected",
                  "version": "5000"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luis Martinez"
            }
          ],
          "datePublic": "2019-11-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Studio 5000 Logix Designer 30.01.00 contains an unquoted service path vulnerability in the FactoryTalk Activation Service that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\\Program Files (x86)\\Rockwell Software\\FactoryTalk Activation\\ to inject malicious code that would execute with LocalSystem permissions."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS"
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-428",
                  "description": "Unquoted Search Path or Element",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-04T23:15:52.435Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "ExploitDB-47676",
              "tags": [
                "exploit"
              ],
              "url": "https://www.exploit-db.com/exploits/47676"
            },
            {
              "name": "Rockwell Automation Homepage",
              "tags": [
                "product"
              ],
              "url": "https://www.rockwellautomation.com/en_NA/overview.page"
            },
            {
              "name": "VulnCheck Advisory: Studio 5000 Logix Designer 30.01.00 - \u0027FactoryTalk Activation Service\u0027 Unquoted Service Path",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/studio-logix-designer-factorytalk-activation-service-unquoted-service-path"
            }
          ],
          "title": "Studio 5000 Logix Designer 30.01.00 - \u0027FactoryTalk Activation Service\u0027 Unquoted Service Path",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2019-25276",
        "datePublished": "2026-02-04T23:15:52.435Z",
        "dateReserved": "2026-01-06T16:07:08.526Z",
        "dateUpdated": "2026-02-05T17:24:48.227Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2019-25276 (GCVE-0-2019-25276)

    Vulnerability from cvelistv5 – Published: 2026-02-04 23:15 – Updated: 2026-02-05 17:24
    VLAI
    Title
    Studio 5000 Logix Designer 30.01.00 - 'FactoryTalk Activation Service' Unquoted Service Path
    Summary
    Studio 5000 Logix Designer 30.01.00 contains an unquoted service path vulnerability in the FactoryTalk Activation Service that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\Program Files (x86)\Rockwell Software\FactoryTalk Activation\ to inject malicious code that would execute with LocalSystem permissions.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-428 - Unquoted Search Path or Element
    Assigner
    Impacted products
    Date Public
    2019-11-18 00:00
    Credits
    Luis Martinez
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2019-25276",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-05T17:24:42.525254Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-05T17:24:48.227Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Studio",
              "vendor": "Rockwellautomation",
              "versions": [
                {
                  "status": "affected",
                  "version": "5000"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luis Martinez"
            }
          ],
          "datePublic": "2019-11-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Studio 5000 Logix Designer 30.01.00 contains an unquoted service path vulnerability in the FactoryTalk Activation Service that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\\Program Files (x86)\\Rockwell Software\\FactoryTalk Activation\\ to inject malicious code that would execute with LocalSystem permissions."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS"
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-428",
                  "description": "Unquoted Search Path or Element",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-04T23:15:52.435Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "ExploitDB-47676",
              "tags": [
                "exploit"
              ],
              "url": "https://www.exploit-db.com/exploits/47676"
            },
            {
              "name": "Rockwell Automation Homepage",
              "tags": [
                "product"
              ],
              "url": "https://www.rockwellautomation.com/en_NA/overview.page"
            },
            {
              "name": "VulnCheck Advisory: Studio 5000 Logix Designer 30.01.00 - \u0027FactoryTalk Activation Service\u0027 Unquoted Service Path",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/studio-logix-designer-factorytalk-activation-service-unquoted-service-path"
            }
          ],
          "title": "Studio 5000 Logix Designer 30.01.00 - \u0027FactoryTalk Activation Service\u0027 Unquoted Service Path",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2019-25276",
        "datePublished": "2026-02-04T23:15:52.435Z",
        "dateReserved": "2026-01-06T16:07:08.526Z",
        "dateUpdated": "2026-02-05T17:24:48.227Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",