    10 vulnerabilities found for SoMachine by Schneider Electric

    VAR-201502-0244

    Vulnerability from variot - Updated: 2025-09-07 23:20

    Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors. This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Schneider Electric SoMove Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the IsObjectModel.ModelObject.1 ActiveX control in isObjectModel.dll. The control does not check the length of an attacker-supplied string in the RemoveParameter method before copying it into a fixed length buffer on the stack. This allows an attacker to execute arbitrary code in the context of the browser process. Schneider Electric provides total solutions for the energy and infrastructure, industrial, data center and network, building and residential markets in more than 100 countries. Failed exploit attempts will result in a denial-of-service condition. Schneider Electric Unity Pro, etc. are all products of French Schneider Electric (Schneider Electric). Schneider Electric Unity Pro is a set of development software for testing, debugging and managing applications; SoMachine is a set of original equipment manufacturer (OEM) automation platform integrated with Vijeo-Designer (human machine interface HMI development software); SoMove is a Installation software for motor control equipment

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201502-0244",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "somachine",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "somove lite",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "unity pro",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "somove",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "somove lite",
            "scope": null,
            "trust": 1.5,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "somachine",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "somove",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "unity pro",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "electric unity pro",
            "scope": null,
            "trust": 0.6,
            "vendor": "schneider",
            "version": null
          },
          {
            "model": "electric somachine",
            "scope": null,
            "trust": 0.6,
            "vendor": "schneider",
            "version": null
          },
          {
            "model": "electric somove lite",
            "scope": null,
            "trust": 0.6,
            "vendor": "schneider",
            "version": null
          },
          {
            "model": "electric somove",
            "scope": null,
            "trust": 0.6,
            "vendor": "schneider",
            "version": null
          },
          {
            "model": "electric modbus communication library",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "schneider",
            "version": "\u003c=2.2.6"
          },
          {
            "model": "electric canopen communication library",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "schneider",
            "version": "\u003c=1.0.2"
          },
          {
            "model": "electric ethernet/ip communication librar",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "schneider",
            "version": "\u003c=1.0.0"
          },
          {
            "model": "electric xantrex dtms",
            "scope": null,
            "trust": 0.6,
            "vendor": "schneider",
            "version": null
          },
          {
            "model": "electric solo dtm",
            "scope": null,
            "trust": 0.6,
            "vendor": "schneider",
            "version": null
          },
          {
            "model": "electric advantys dtms",
            "scope": null,
            "trust": 0.6,
            "vendor": "schneider",
            "version": null
          },
          {
            "model": "electric em gateway dtm",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "schneider",
            "version": "x80"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "somachine",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "somove",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "somove lite",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "unity pro",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "a52677d8-2351-11e6-abef-000c29c66e3d"
          },
          {
            "db": "ZDI",
            "id": "ZDI-15-040"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2015-00775"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201502-005"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2014-007827"
          },
          {
            "db": "NVD",
            "id": "CVE-2014-9200"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:somachine",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:somove",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:somove_lite",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:unity_pro",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2014-007827"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Ariele Caltabiano (kimiya)",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-15-040"
          },
          {
            "db": "BID",
            "id": "72335"
          }
        ],
        "trust": 1.0
      },
      "cve": "CVE-2014-9200",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "ics-cert@hq.dhs.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2014-9200",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 3.5,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2015-00775",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "a52677d8-2351-11e6-abef-000c29c66e3d",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.2,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-77145",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [],
            "severity": [
              {
                "author": "ics-cert@hq.dhs.gov",
                "id": "CVE-2014-9200",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2014-9200",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2014-9200",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "ZDI",
                "id": "CVE-2014-9200",
                "trust": 0.7,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2015-00775",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201502-005",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "IVD",
                "id": "a52677d8-2351-11e6-abef-000c29c66e3d",
                "trust": 0.2,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-77145",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "a52677d8-2351-11e6-abef-000c29c66e3d"
          },
          {
            "db": "ZDI",
            "id": "ZDI-15-040"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2015-00775"
          },
          {
            "db": "VULHUB",
            "id": "VHN-77145"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201502-005"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2014-007827"
          },
          {
            "db": "NVD",
            "id": "CVE-2014-9200"
          },
          {
            "db": "NVD",
            "id": "CVE-2014-9200"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors. This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Schneider Electric SoMove Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the IsObjectModel.ModelObject.1 ActiveX control in isObjectModel.dll. The control does not check the length of an attacker-supplied string in the RemoveParameter method before copying it into a fixed length buffer on the stack. This allows an attacker to execute arbitrary code in the context of the browser process. Schneider Electric provides total solutions for the energy and infrastructure, industrial, data center and network, building and residential markets in more than 100 countries. Failed exploit attempts will result in a denial-of-service condition. Schneider Electric Unity Pro, etc. are all products of French Schneider Electric (Schneider Electric). Schneider Electric Unity Pro is a set of development software for testing, debugging and managing applications; SoMachine is a set of original equipment manufacturer (OEM) automation platform integrated with Vijeo-Designer (human machine interface HMI development software); SoMove is a Installation software for motor control equipment",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2014-9200"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2014-007827"
          },
          {
            "db": "ZDI",
            "id": "ZDI-15-040"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2015-00775"
          },
          {
            "db": "BID",
            "id": "72335"
          },
          {
            "db": "IVD",
            "id": "a52677d8-2351-11e6-abef-000c29c66e3d"
          },
          {
            "db": "VULHUB",
            "id": "VHN-77145"
          }
        ],
        "trust": 3.33
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2014-9200",
            "trust": 4.3
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-15-027-02",
            "trust": 3.1
          },
          {
            "db": "BID",
            "id": "72335",
            "trust": 2.0
          },
          {
            "db": "SCHNEIDER",
            "id": "SEVD-2015-009-01",
            "trust": 1.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201502-005",
            "trust": 0.9
          },
          {
            "db": "CNVD",
            "id": "CNVD-2015-00775",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2014-007827",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-2478",
            "trust": 0.7
          },
          {
            "db": "ZDI",
            "id": "ZDI-15-040",
            "trust": 0.7
          },
          {
            "db": "IVD",
            "id": "A52677D8-2351-11E6-ABEF-000C29C66E3D",
            "trust": 0.2
          },
          {
            "db": "VULHUB",
            "id": "VHN-77145",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "a52677d8-2351-11e6-abef-000c29c66e3d"
          },
          {
            "db": "ZDI",
            "id": "ZDI-15-040"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2015-00775"
          },
          {
            "db": "VULHUB",
            "id": "VHN-77145"
          },
          {
            "db": "BID",
            "id": "72335"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201502-005"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2014-007827"
          },
          {
            "db": "NVD",
            "id": "CVE-2014-9200"
          }
        ]
      },
      "id": "VAR-201502-0244",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "a52677d8-2351-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2015-00775"
          },
          {
            "db": "VULHUB",
            "id": "VHN-77145"
          }
        ],
        "trust": 1.84333333
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "a52677d8-2351-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2015-00775"
          }
        ]
      },
      "last_update_date": "2025-09-07T23:20:15.580000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "SEVD-2015-009-01",
            "trust": 0.8,
            "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-009-01"
          },
          {
            "title": "Schneider Electric has issued an update to correct this vulnerability.",
            "trust": 0.7,
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-027-02"
          },
          {
            "title": "Patch for multiple Schneider Electric product stack buffer overflow vulnerabilities",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/54843"
          },
          {
            "title": "FDT1 DLL Removal Patch",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=53580"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-15-040"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2015-00775"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201502-005"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2014-007827"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.9
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-77145"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2014-007827"
          },
          {
            "db": "NVD",
            "id": "CVE-2014-9200"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.8,
            "url": "https://ics-cert.us-cert.gov/advisories/icsa-15-027-02"
          },
          {
            "trust": 2.7,
            "url": "http://download.schneider-electric.com/files?p_doc_ref=sevd-2015-009-01"
          },
          {
            "trust": 1.7,
            "url": "http://www.securityfocus.com/bid/72335"
          },
          {
            "trust": 1.0,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-027-02"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-9200"
          },
          {
            "trust": 0.8,
            "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2014-9200"
          },
          {
            "trust": 0.3,
            "url": "http://www.schneider-electric.com/site/home/index.cfm/ww/?selectcountry=true"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-15-040"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2015-00775"
          },
          {
            "db": "VULHUB",
            "id": "VHN-77145"
          },
          {
            "db": "BID",
            "id": "72335"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201502-005"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2014-007827"
          },
          {
            "db": "NVD",
            "id": "CVE-2014-9200"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "a52677d8-2351-11e6-abef-000c29c66e3d"
          },
          {
            "db": "ZDI",
            "id": "ZDI-15-040"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2015-00775"
          },
          {
            "db": "VULHUB",
            "id": "VHN-77145"
          },
          {
            "db": "BID",
            "id": "72335"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201502-005"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2014-007827"
          },
          {
            "db": "NVD",
            "id": "CVE-2014-9200"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2015-02-02T00:00:00",
            "db": "IVD",
            "id": "a52677d8-2351-11e6-abef-000c29c66e3d"
          },
          {
            "date": "2015-02-10T00:00:00",
            "db": "ZDI",
            "id": "ZDI-15-040"
          },
          {
            "date": "2015-01-30T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2015-00775"
          },
          {
            "date": "2015-02-01T00:00:00",
            "db": "VULHUB",
            "id": "VHN-77145"
          },
          {
            "date": "2015-01-09T00:00:00",
            "db": "BID",
            "id": "72335"
          },
          {
            "date": "2015-02-02T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201502-005"
          },
          {
            "date": "2015-02-13T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2014-007827"
          },
          {
            "date": "2015-02-01T15:59:06.197000",
            "db": "NVD",
            "id": "CVE-2014-9200"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2015-02-10T00:00:00",
            "db": "ZDI",
            "id": "ZDI-15-040"
          },
          {
            "date": "2015-02-02T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2015-00775"
          },
          {
            "date": "2016-12-31T00:00:00",
            "db": "VULHUB",
            "id": "VHN-77145"
          },
          {
            "date": "2015-07-15T00:14:00",
            "db": "BID",
            "id": "72335"
          },
          {
            "date": "2015-02-02T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201502-005"
          },
          {
            "date": "2015-02-13T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2014-007827"
          },
          {
            "date": "2025-09-05T22:15:33.803000",
            "db": "NVD",
            "id": "CVE-2014-9200"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201502-005"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  Schneider Electric Product  DTM Unspecified development kit  DLL File stack-based buffer overflow vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2014-007827"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Buffer overflow",
        "sources": [
          {
            "db": "IVD",
            "id": "a52677d8-2351-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201502-005"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-201706-0651

    Vulnerability from variot - Updated: 2025-04-20 23:30

    A DLL Hijacking vulnerability in the programming software in Schneider Electric's SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on the targeted system. The vulnerability exists due to the improper loading of a DLL. SoMachine HVAC is a PLC programming software

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201706-0651",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "somachine",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "schneider electric",
            "version": "2.1.0"
          },
          {
            "model": "somachine",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": "hvac 2.1.0"
          },
          {
            "model": "electric somachine hvac",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "schneider",
            "version": "2.1.0"
          },
          {
            "model": "somachine hvac",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "schneider electric",
            "version": "2.1"
          },
          {
            "model": "somachine hvac",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "schneider electric",
            "version": "2.2"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "somachine",
            "version": "2.1.0"
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "d24e5bf7-8f13-41cd-9ff1-9b9f830fd317"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-10359"
          },
          {
            "db": "BID",
            "id": "98446"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004715"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-902"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7966"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:somachine",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004715"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Himanshu Mehta",
        "sources": [
          {
            "db": "BID",
            "id": "98446"
          }
        ],
        "trust": 0.3
      },
      "cve": "CVE-2017-7966",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2017-7966",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CNVD-2017-10359",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "d24e5bf7-8f13-41cd-9ff1-9b9f830fd317",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.2,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "VHN-116169",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2017-7966",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2017-7966",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2017-7966",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-10359",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201704-902",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "IVD",
                "id": "d24e5bf7-8f13-41cd-9ff1-9b9f830fd317",
                "trust": 0.2,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-116169",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "d24e5bf7-8f13-41cd-9ff1-9b9f830fd317"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-10359"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116169"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004715"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-902"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7966"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A DLL Hijacking vulnerability in the programming software in Schneider Electric\u0027s SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on the targeted system. The vulnerability exists due to the improper loading of a DLL. SoMachine HVAC is a PLC programming software",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-7966"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004715"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-10359"
          },
          {
            "db": "BID",
            "id": "98446"
          },
          {
            "db": "IVD",
            "id": "d24e5bf7-8f13-41cd-9ff1-9b9f830fd317"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116169"
          }
        ],
        "trust": 2.7
      },
      "exploit_availability": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "reference": "https://www.scap.org.cn/vuln/vhn-116169",
            "trust": 0.1,
            "type": "unknown"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-116169"
          }
        ]
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-7966",
            "trust": 3.6
          },
          {
            "db": "BID",
            "id": "98446",
            "trust": 2.6
          },
          {
            "db": "SCHNEIDER",
            "id": "SEVD-2017-125-02",
            "trust": 2.0
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-902",
            "trust": 0.9
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-10359",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004715",
            "trust": 0.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-17-136-02",
            "trust": 0.3
          },
          {
            "db": "IVD",
            "id": "D24E5BF7-8F13-41CD-9FF1-9B9F830FD317",
            "trust": 0.2
          },
          {
            "db": "VULHUB",
            "id": "VHN-116169",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "d24e5bf7-8f13-41cd-9ff1-9b9f830fd317"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-10359"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116169"
          },
          {
            "db": "BID",
            "id": "98446"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004715"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-902"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7966"
          }
        ]
      },
      "id": "VAR-201706-0651",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "d24e5bf7-8f13-41cd-9ff1-9b9f830fd317"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-10359"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116169"
          }
        ],
        "trust": 1.9
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "d24e5bf7-8f13-41cd-9ff1-9b9f830fd317"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-10359"
          }
        ]
      },
      "last_update_date": "2025-04-20T23:30:59.713000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "SEVD-2017-125-02",
            "trust": 0.8,
            "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-02/"
          },
          {
            "title": "Schneider Electric SoMachine HVAC patch for arbitrary code execution vulnerabilities",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/95695"
          },
          {
            "title": "Schneider Electric SoMachine HVAC Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=99739"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-10359"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004715"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-902"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-427",
            "trust": 1.1
          },
          {
            "problemtype": "CWE-284",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-116169"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004715"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7966"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.3,
            "url": "http://www.securityfocus.com/bid/98446"
          },
          {
            "trust": 2.0,
            "url": "http://www.schneider-electric.com/en/download/document/sevd-2017-125-02/"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-7966"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-7966"
          },
          {
            "trust": 0.3,
            "url": "http://blog.rapid7.com/?p=5325"
          },
          {
            "trust": 0.3,
            "url": "http://blog.metasploit.com/2010/08/exploiting-dll-hijacking-flaws.html"
          },
          {
            "trust": 0.3,
            "url": "http://blogs.technet.com/b/srd/archive/2010/08/23/more-information-about-dll-preloading-remote-attack-vector.aspx"
          },
          {
            "trust": 0.3,
            "url": "http://www.schneider-electric.com/site/home/index.cfm/ww/?selectcountry=true"
          },
          {
            "trust": 0.3,
            "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-136-02"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-10359"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116169"
          },
          {
            "db": "BID",
            "id": "98446"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004715"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-902"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7966"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "d24e5bf7-8f13-41cd-9ff1-9b9f830fd317"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-10359"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116169"
          },
          {
            "db": "BID",
            "id": "98446"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004715"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-902"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7966"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-06-20T00:00:00",
            "db": "IVD",
            "id": "d24e5bf7-8f13-41cd-9ff1-9b9f830fd317"
          },
          {
            "date": "2017-06-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-10359"
          },
          {
            "date": "2017-06-07T00:00:00",
            "db": "VULHUB",
            "id": "VHN-116169"
          },
          {
            "date": "2017-05-05T00:00:00",
            "db": "BID",
            "id": "98446"
          },
          {
            "date": "2017-07-05T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-004715"
          },
          {
            "date": "2017-04-20T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201704-902"
          },
          {
            "date": "2017-06-07T19:29:00.227000",
            "db": "NVD",
            "id": "CVE-2017-7966"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-06-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-10359"
          },
          {
            "date": "2019-10-03T00:00:00",
            "db": "VULHUB",
            "id": "VHN-116169"
          },
          {
            "date": "2017-05-23T16:26:00",
            "db": "BID",
            "id": "98446"
          },
          {
            "date": "2017-07-05T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-004715"
          },
          {
            "date": "2019-10-23T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201704-902"
          },
          {
            "date": "2025-04-20T01:37:25.860000",
            "db": "NVD",
            "id": "CVE-2017-7966"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-902"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Schneider Electric SoMachine HVAC Arbitrary code execution vulnerability",
        "sources": [
          {
            "db": "IVD",
            "id": "d24e5bf7-8f13-41cd-9ff1-9b9f830fd317"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-10359"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Code problem",
        "sources": [
          {
            "db": "IVD",
            "id": "d24e5bf7-8f13-41cd-9ff1-9b9f830fd317"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-902"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-201706-0650

    Vulnerability from variot - Updated: 2025-04-20 23:30

    A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller. SoMachine HVAC is a PLC programming software. This vulnerability stems from a security vulnerability in the call to AlTracePrint.exe, which can be exploited by an attacker to cause a buffer overflow. Schneider Electric SoMachine HVAC is prone to a local buffer-overflow vulnerability because it fails to perform adequate boundary checks on user-supplied data. Successful exploits may allow attackers to execute arbitrary code in context of the application. Failed exploits may result in denial-of-service conditions. Schneider Electric SoMachine HVAC 2.1.0 is vulnerable; other versions may also be affected

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201706-0650",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "somachine hvac",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "2.1.0"
          },
          {
            "model": "somachine",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": "v2.1.0"
          },
          {
            "model": "electric somachine hvac",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "schneider",
            "version": "2.1.0"
          },
          {
            "model": "somachine",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "schneider electric",
            "version": "2.1.0"
          },
          {
            "model": "somachine hvac",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "schneider electric",
            "version": "2.1"
          },
          {
            "model": "somachine hvac",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "schneider electric",
            "version": "2.2"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "somachine hvac",
            "version": "2.1.0"
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "11b1075a-684e-41ec-9aa9-c1b9110102d1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-10357"
          },
          {
            "db": "BID",
            "id": "98449"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004756"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-903"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7965"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:somachine",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004756"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Zhou Yu",
        "sources": [
          {
            "db": "BID",
            "id": "98449"
          }
        ],
        "trust": 0.3
      },
      "cve": "CVE-2017-7965",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 4.6,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 3.9,
                "id": "CVE-2017-7965",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 4.6,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2017-10357",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 4.6,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 3.9,
                "id": "11b1075a-684e-41ec-9aa9-c1b9110102d1",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.2,
                "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 4.6,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 3.9,
                "id": "VHN-116168",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:L/AC:L/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.3,
                "id": "CVE-2017-7965",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.3,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2017-7965",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2017-7965",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2017-7965",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-10357",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201704-903",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "IVD",
                "id": "11b1075a-684e-41ec-9aa9-c1b9110102d1",
                "trust": 0.2,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-116168",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "11b1075a-684e-41ec-9aa9-c1b9110102d1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-10357"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116168"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004756"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-903"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7965"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric\u0027s SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller. SoMachine HVAC is a PLC programming software. This vulnerability stems from a security vulnerability in the call to AlTracePrint.exe, which can be exploited by an attacker to cause a buffer overflow. Schneider Electric SoMachine HVAC is prone to a local buffer-overflow vulnerability because it fails to perform adequate boundary checks on user-supplied data. \nSuccessful exploits may allow attackers to execute arbitrary code in context of the application. Failed exploits may result in denial-of-service conditions. \nSchneider Electric SoMachine HVAC 2.1.0 is vulnerable; other versions may also be affected",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-7965"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004756"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-10357"
          },
          {
            "db": "BID",
            "id": "98449"
          },
          {
            "db": "IVD",
            "id": "11b1075a-684e-41ec-9aa9-c1b9110102d1"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116168"
          }
        ],
        "trust": 2.7
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-7965",
            "trust": 3.6
          },
          {
            "db": "BID",
            "id": "98449",
            "trust": 2.6
          },
          {
            "db": "SCHNEIDER",
            "id": "SEVD-2017-125-01",
            "trust": 2.0
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-903",
            "trust": 0.9
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-10357",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004756",
            "trust": 0.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-17-136-02",
            "trust": 0.3
          },
          {
            "db": "IVD",
            "id": "11B1075A-684E-41EC-9AA9-C1B9110102D1",
            "trust": 0.2
          },
          {
            "db": "VULHUB",
            "id": "VHN-116168",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "11b1075a-684e-41ec-9aa9-c1b9110102d1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-10357"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116168"
          },
          {
            "db": "BID",
            "id": "98449"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004756"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-903"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7965"
          }
        ]
      },
      "id": "VAR-201706-0650",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "11b1075a-684e-41ec-9aa9-c1b9110102d1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-10357"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116168"
          }
        ],
        "trust": 1.9
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "11b1075a-684e-41ec-9aa9-c1b9110102d1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-10357"
          }
        ]
      },
      "last_update_date": "2025-04-20T23:30:59.674000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "SEVD-2017-125-01",
            "trust": 0.8,
            "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
          },
          {
            "title": "Schneider Electric SoMachine HVAC Stack Buffer Overflow Vulnerability Patch",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/95693"
          },
          {
            "title": "Schneider Electric Modicon M171/M172 Controller SoMachine HVAC Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=100390"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-10357"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004756"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-903"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-116168"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004756"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7965"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.3,
            "url": "http://www.securityfocus.com/bid/98449"
          },
          {
            "trust": 2.0,
            "url": "http://www.schneider-electric.com/en/download/document/sevd-2017-125-01/"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-7965"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-7965"
          },
          {
            "trust": 0.3,
            "url": "http://www.schneider-electric.com/site/home/index.cfm/ww/?selectcountry=true"
          },
          {
            "trust": 0.3,
            "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-136-02"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-10357"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116168"
          },
          {
            "db": "BID",
            "id": "98449"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004756"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-903"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7965"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "11b1075a-684e-41ec-9aa9-c1b9110102d1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-10357"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116168"
          },
          {
            "db": "BID",
            "id": "98449"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004756"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-903"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7965"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-06-20T00:00:00",
            "db": "IVD",
            "id": "11b1075a-684e-41ec-9aa9-c1b9110102d1"
          },
          {
            "date": "2017-06-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-10357"
          },
          {
            "date": "2017-06-07T00:00:00",
            "db": "VULHUB",
            "id": "VHN-116168"
          },
          {
            "date": "2017-05-05T00:00:00",
            "db": "BID",
            "id": "98449"
          },
          {
            "date": "2017-07-06T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-004756"
          },
          {
            "date": "2017-04-20T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201704-903"
          },
          {
            "date": "2017-06-07T19:29:00.197000",
            "db": "NVD",
            "id": "CVE-2017-7965"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-06-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-10357"
          },
          {
            "date": "2019-10-03T00:00:00",
            "db": "VULHUB",
            "id": "VHN-116168"
          },
          {
            "date": "2017-05-23T16:26:00",
            "db": "BID",
            "id": "98449"
          },
          {
            "date": "2017-07-06T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-004756"
          },
          {
            "date": "2021-08-24T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201704-903"
          },
          {
            "date": "2025-04-20T01:37:25.860000",
            "db": "NVD",
            "id": "CVE-2017-7965"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "local",
        "sources": [
          {
            "db": "BID",
            "id": "98449"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-903"
          }
        ],
        "trust": 0.9
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Schneider Electric SoMachine HVAC Stack Buffer Overflow Vulnerability",
        "sources": [
          {
            "db": "IVD",
            "id": "11b1075a-684e-41ec-9aa9-c1b9110102d1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-10357"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Buffer error",
        "sources": [
          {
            "db": "IVD",
            "id": "11b1075a-684e-41ec-9aa9-c1b9110102d1"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-903"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-201704-1421

    Vulnerability from variot - Updated: 2025-04-20 23:05

    Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product. Schneider Electric SoMachine Basic and Modicon Contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) An attack may be carried out. The former is a programming and debugging interface for all components on the control platform; the latter is a programmable controller. An attacker could exploit the vulnerability to open and modify protected project files with Schneider's products. A remote attacker may leverage this issue to gain root access to the affected system

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201704-1421",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "modicon tm221ce16r",
            "scope": "eq",
            "trust": 1.9,
            "vendor": "schneider electric",
            "version": "1.3.3.3"
          },
          {
            "model": "somachine",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "schneider electric",
            "version": "1.4"
          },
          {
            "model": "modicon tm221ce16r",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "somachine",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": "basic software"
          },
          {
            "model": "electric modicon tm221ce16r",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "schneider",
            "version": "1.3.3.3"
          },
          {
            "model": "electric somachine basic sp1",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "schneider",
            "version": "1.4"
          },
          {
            "model": "somachine basic",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "schneider electric",
            "version": "1.5"
          },
          {
            "model": "somachine basic sp1",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "schneider electric",
            "version": "1.4"
          },
          {
            "model": "modicon m221",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "schneider electric",
            "version": "1.5.0.1"
          },
          {
            "model": "modicon m221",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "schneider electric",
            "version": "1.5.0.0"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "modicon tm221ce16r",
            "version": "1.3.3.3"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "somachine",
            "version": "1.4"
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "baed19f0-f146-47b4-be70-37b627575985"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-05014"
          },
          {
            "db": "BID",
            "id": "97518"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003056"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-273"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7574"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:schneider_electric:modicon_tm221ce16r_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:somachine",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003056"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Simon Heming, Maik Br\u00fcggemann, Hendrik Schwartke, Ralf Spenneberg.",
        "sources": [
          {
            "db": "BID",
            "id": "97518"
          }
        ],
        "trust": 0.3
      },
      "cve": "CVE-2017-7574",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2017-7574",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 1.9,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2017-05014",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "baed19f0-f146-47b4-be70-37b627575985",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.2,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-115777",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2017-7574",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2017-7574",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2017-7574",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2017-7574",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-05014",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201704-273",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "IVD",
                "id": "baed19f0-f146-47b4-be70-37b627575985",
                "trust": 0.2,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-115777",
                "trust": 0.1,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2017-7574",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "baed19f0-f146-47b4-be70-37b627575985"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-05014"
          },
          {
            "db": "VULHUB",
            "id": "VHN-115777"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-7574"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003056"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-273"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7574"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product. Schneider Electric SoMachine Basic and Modicon Contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) An attack may be carried out. The former is a programming and debugging interface for all components on the control platform; the latter is a programmable controller. An attacker could exploit the vulnerability to open and modify protected project files with Schneider\u0027s products. \nA remote attacker may leverage this issue to gain root access to the affected system",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-7574"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003056"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-05014"
          },
          {
            "db": "BID",
            "id": "97518"
          },
          {
            "db": "IVD",
            "id": "baed19f0-f146-47b4-be70-37b627575985"
          },
          {
            "db": "VULHUB",
            "id": "VHN-115777"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-7574"
          }
        ],
        "trust": 2.79
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-7574",
            "trust": 3.7
          },
          {
            "db": "BID",
            "id": "97518",
            "trust": 3.5
          },
          {
            "db": "SCHNEIDER",
            "id": "SEVD-2017-097-01",
            "trust": 1.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-17-103-02",
            "trust": 1.1
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-273",
            "trust": 0.9
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-05014",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003056",
            "trust": 0.8
          },
          {
            "db": "IVD",
            "id": "BAED19F0-F146-47B4-BE70-37B627575985",
            "trust": 0.2
          },
          {
            "db": "VULHUB",
            "id": "VHN-115777",
            "trust": 0.1
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-17-103-02A",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-7574",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "baed19f0-f146-47b4-be70-37b627575985"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-05014"
          },
          {
            "db": "VULHUB",
            "id": "VHN-115777"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-7574"
          },
          {
            "db": "BID",
            "id": "97518"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003056"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-273"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7574"
          }
        ]
      },
      "id": "VAR-201704-1421",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "baed19f0-f146-47b4-be70-37b627575985"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-05014"
          },
          {
            "db": "VULHUB",
            "id": "VHN-115777"
          }
        ],
        "trust": 1.8444444333333334
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "baed19f0-f146-47b4-be70-37b627575985"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-05014"
          }
        ]
      },
      "last_update_date": "2025-04-20T23:05:06.381000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "SEVD-2017-097-01",
            "trust": 0.8,
            "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-01"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003056"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-798",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-115777"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003056"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7574"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.7,
            "url": "https://os-s.net/advisories/oss-2017-02.pdf"
          },
          {
            "trust": 1.9,
            "url": "http://www.securityfocus.com/bid/97518"
          },
          {
            "trust": 1.8,
            "url": "http://download.schneider-electric.com/files?p_doc_ref=sevd-2017-097-01"
          },
          {
            "trust": 1.1,
            "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-103-02"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-7574"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-7574"
          },
          {
            "trust": 0.8,
            "url": "http://www.securityfocus.com/bid/97518/info"
          },
          {
            "trust": 0.3,
            "url": "http://www.schneider-electric.com/site/home/index.cfm/ww/?selectcountry=true"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/798.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          },
          {
            "trust": 0.1,
            "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-103-02a"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-05014"
          },
          {
            "db": "VULHUB",
            "id": "VHN-115777"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-7574"
          },
          {
            "db": "BID",
            "id": "97518"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003056"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-273"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7574"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "baed19f0-f146-47b4-be70-37b627575985"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-05014"
          },
          {
            "db": "VULHUB",
            "id": "VHN-115777"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-7574"
          },
          {
            "db": "BID",
            "id": "97518"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003056"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-273"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7574"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-04-22T00:00:00",
            "db": "IVD",
            "id": "baed19f0-f146-47b4-be70-37b627575985"
          },
          {
            "date": "2017-04-22T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-05014"
          },
          {
            "date": "2017-04-06T00:00:00",
            "db": "VULHUB",
            "id": "VHN-115777"
          },
          {
            "date": "2017-04-06T00:00:00",
            "db": "VULMON",
            "id": "CVE-2017-7574"
          },
          {
            "date": "2017-04-06T00:00:00",
            "db": "BID",
            "id": "97518"
          },
          {
            "date": "2017-05-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-003056"
          },
          {
            "date": "2017-04-11T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201704-273"
          },
          {
            "date": "2017-04-06T21:59:00.307000",
            "db": "NVD",
            "id": "CVE-2017-7574"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-04-22T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-05014"
          },
          {
            "date": "2017-04-15T00:00:00",
            "db": "VULHUB",
            "id": "VHN-115777"
          },
          {
            "date": "2021-08-23T00:00:00",
            "db": "VULMON",
            "id": "CVE-2017-7574"
          },
          {
            "date": "2017-04-18T01:06:00",
            "db": "BID",
            "id": "97518"
          },
          {
            "date": "2017-05-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-003056"
          },
          {
            "date": "2021-08-24T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201704-273"
          },
          {
            "date": "2025-04-20T01:37:25.860000",
            "db": "NVD",
            "id": "CVE-2017-7574"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-273"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Schneider Electric SoMachine Basic and  Modicon Vulnerabilities related to the use of hard-coded credentials",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003056"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "trust management problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-273"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201404-0081

    Vulnerability from variot - Updated: 2025-04-13 23:27

    Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header. Schneider Electric provides total solutions for the energy and infrastructure, industrial, data center and network, building and residential markets in more than 100 countries. The Modbus Serial driver used by many Schneider Electric products monitors the TCP 27700 port. Successful exploitation of vulnerabilities can execute arbitrary code in the context of an application. Multiple Schneider Electric Products are prone to a remote buffer-overflow vulnerability because it fails to properly validate user-supplied input. Failed exploit attempts will result in a denial-of-service condition. The following products are vulnerable: TwidoSuite 2.31.04 and prior PowerSuite 2.6 and prior SoMove 1.7 and prior SoMachine 2.0, 3.0, 3.1, and 3.0 XS Unity Pro 7.0 and prior UnityLoader 2.3 and prior Concept 2.6 SR7 and prior ModbusCommDTM sl 2.1.2 and prior PL7 4.5 SP5 and prior SFT2841 14, 13.1 and prior OPC Factory Server 3.50 and prior

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201404-0081",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "somachine",
            "scope": "eq",
            "trust": 2.8,
            "vendor": "schneider electric",
            "version": "3.0"
          },
          {
            "model": "modbuscommdtm sl",
            "scope": "lte",
            "trust": 1.8,
            "vendor": "schneider electric",
            "version": "2.1.2"
          },
          {
            "model": "powersuite",
            "scope": "lte",
            "trust": 1.8,
            "vendor": "schneider electric",
            "version": "2.6"
          },
          {
            "model": "somachine",
            "scope": "eq",
            "trust": 1.8,
            "vendor": "schneider electric",
            "version": "2.0"
          },
          {
            "model": "somove",
            "scope": "lte",
            "trust": 1.8,
            "vendor": "schneider electric",
            "version": "1.7"
          },
          {
            "model": "twidosuite",
            "scope": "lte",
            "trust": 1.8,
            "vendor": "schneider electric",
            "version": "2.31.04"
          },
          {
            "model": "unity pro",
            "scope": "lte",
            "trust": 1.8,
            "vendor": "schneider electric",
            "version": "7.0"
          },
          {
            "model": "sft2841",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "schneider electric",
            "version": "13.1"
          },
          {
            "model": "modbus serial driver",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "schneider electric",
            "version": "2.2"
          },
          {
            "model": "opc factory server",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "schneider electric",
            "version": "3.35"
          },
          {
            "model": "modbus serial driver",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "schneider electric",
            "version": "1.10"
          },
          {
            "model": "modbus serial driver",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "schneider electric",
            "version": "3.2"
          },
          {
            "model": "opc factory server",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "schneider electric",
            "version": "3.34"
          },
          {
            "model": "concept",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "2.6"
          },
          {
            "model": "sft2841",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "14.0"
          },
          {
            "model": "opc factory server",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "3.5.0"
          },
          {
            "model": "unity pro",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "6.0"
          },
          {
            "model": "somachine",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "3.1"
          },
          {
            "model": "pl7",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "4.5"
          },
          {
            "model": "unityloader",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "2.3"
          },
          {
            "model": "concept",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": "2.6 sr7"
          },
          {
            "model": "modbus serial driver",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": "1.10 to  3.2"
          },
          {
            "model": "opc factory server",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": "3.40"
          },
          {
            "model": "pl7",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": "4.5 sp5"
          },
          {
            "model": "sft2841",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": "13.1"
          },
          {
            "model": "sft2841",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": "14"
          },
          {
            "model": "somachine",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": "3.0 xs"
          },
          {
            "model": "somachine",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": "3.1"
          },
          {
            "model": "unity loader",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": "2.3"
          },
          {
            "model": "electric opc factory server",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "schneider",
            "version": "3.5"
          },
          {
            "model": "electric tlxcdsuofs33",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "schneider",
            "version": "3.5"
          },
          {
            "model": "electric tlxcdstofs33",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "schneider",
            "version": "3.5"
          },
          {
            "model": "electric tlxcdluofs33",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "schneider",
            "version": "3.5"
          },
          {
            "model": "electric tlxcdlfofs33",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "schneider",
            "version": "3.5"
          },
          {
            "model": "opc factory server",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "schneider electric",
            "version": "3.5.0"
          },
          {
            "model": "modbuscommdtm sl",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "schneider electric",
            "version": "2.1.2"
          },
          {
            "model": "sft2841",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "schneider electric",
            "version": "14.0"
          },
          {
            "model": "pl7",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "schneider electric",
            "version": "4.5"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.4,
            "vendor": "somachine",
            "version": "3.0"
          },
          {
            "model": "electric unity pro",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "schneider",
            "version": "6.0"
          },
          {
            "model": "electric unity pro",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "schneider",
            "version": "6"
          },
          {
            "model": "electric opc factory server",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "schneider",
            "version": "3.34"
          },
          {
            "model": "electric opc factory driver",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "schneider",
            "version": "3.34"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "concept",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "modbus serial driver",
            "version": "1.10"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "modbus serial driver",
            "version": "2.2"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "modbus serial driver",
            "version": "3.2"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "modbuscommdtm sl",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "opc factory server",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "opc factory server",
            "version": "3.34"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "opc factory server",
            "version": "3.35"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "pl7",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "powersuite",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sft2841",
            "version": "13.1"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sft2841",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "somachine",
            "version": "2.0"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "somachine",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "somove",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "twidosuite",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "unity pro",
            "version": "6.0"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "unity pro",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "unityloader",
            "version": "*"
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "1cbd5cbc-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2014-02043"
          },
          {
            "db": "BID",
            "id": "66500"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-006276"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201404-005"
          },
          {
            "db": "NVD",
            "id": "CVE-2013-0662"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:concept",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:modbus_serial_driver",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:modbuscommdtm_sl",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:opc_factory_server",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:pl7",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:powersuite",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:sft2841",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:somachine",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:somove",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:twidosuite",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:unityloader",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:unity_pro",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-006276"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "This issue is reported by vendor.",
        "sources": [
          {
            "db": "BID",
            "id": "66500"
          }
        ],
        "trust": 0.3
      },
      "cve": "CVE-2013-0662",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.3,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.6,
                "id": "CVE-2013-0662",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.3,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.6,
                "id": "CNVD-2014-02043",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.3,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.6,
                "id": "1cbd5cbc-2352-11e6-abef-000c29c66e3d",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.2,
                "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.3,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.6,
                "id": "VHN-60664",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:M/AU:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2013-0662",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2013-0662",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2014-02043",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201404-005",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "IVD",
                "id": "1cbd5cbc-2352-11e6-abef-000c29c66e3d",
                "trust": 0.2,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-60664",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "1cbd5cbc-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2014-02043"
          },
          {
            "db": "VULHUB",
            "id": "VHN-60664"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-006276"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201404-005"
          },
          {
            "db": "NVD",
            "id": "CVE-2013-0662"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header. Schneider Electric provides total solutions for the energy and infrastructure, industrial, data center and network, building and residential markets in more than 100 countries. The Modbus Serial driver used by many Schneider Electric products monitors the TCP 27700 port. Successful exploitation of vulnerabilities can execute arbitrary code in the context of an application. Multiple Schneider Electric Products are prone to a remote buffer-overflow vulnerability because it fails to properly validate user-supplied input. Failed exploit attempts will result in a denial-of-service condition. \nThe following products are vulnerable:\nTwidoSuite  2.31.04 and prior\nPowerSuite 2.6 and prior\nSoMove 1.7 and prior\nSoMachine 2.0, 3.0, 3.1, and 3.0 XS\nUnity Pro 7.0 and prior\nUnityLoader 2.3 and prior\nConcept 2.6 SR7 and prior\nModbusCommDTM sl 2.1.2 and prior\nPL7 4.5 SP5 and prior\nSFT2841 14, 13.1 and prior\nOPC Factory Server 3.50 and prior",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2013-0662"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-006276"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2014-02043"
          },
          {
            "db": "BID",
            "id": "66500"
          },
          {
            "db": "IVD",
            "id": "1cbd5cbc-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "VULHUB",
            "id": "VHN-60664"
          }
        ],
        "trust": 2.7
      },
      "exploit_availability": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "reference": "https://www.scap.org.cn/vuln/vhn-60664",
            "trust": 0.1,
            "type": "unknown"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-60664"
          }
        ]
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2013-0662",
            "trust": 3.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-14-086-01",
            "trust": 3.1
          },
          {
            "db": "BID",
            "id": "66500",
            "trust": 2.6
          },
          {
            "db": "EXPLOIT-DB",
            "id": "45219",
            "trust": 1.7
          },
          {
            "db": "EXPLOIT-DB",
            "id": "45220",
            "trust": 1.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201404-005",
            "trust": 0.9
          },
          {
            "db": "CNVD",
            "id": "CNVD-2014-02043",
            "trust": 0.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-14-086-01A",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-006276",
            "trust": 0.8
          },
          {
            "db": "OSVDB",
            "id": "105035",
            "trust": 0.6
          },
          {
            "db": "IVD",
            "id": "1CBD5CBC-2352-11E6-ABEF-000C29C66E3D",
            "trust": 0.2
          },
          {
            "db": "PACKETSTORM",
            "id": "149000",
            "trust": 0.1
          },
          {
            "db": "PACKETSTORM",
            "id": "148995",
            "trust": 0.1
          },
          {
            "db": "VULHUB",
            "id": "VHN-60664",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "1cbd5cbc-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2014-02043"
          },
          {
            "db": "VULHUB",
            "id": "VHN-60664"
          },
          {
            "db": "BID",
            "id": "66500"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-006276"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201404-005"
          },
          {
            "db": "NVD",
            "id": "CVE-2013-0662"
          }
        ]
      },
      "id": "VAR-201404-0081",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "1cbd5cbc-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2014-02043"
          },
          {
            "db": "VULHUB",
            "id": "VHN-60664"
          }
        ],
        "trust": 1.7371212090909092
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "1cbd5cbc-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2014-02043"
          }
        ]
      },
      "last_update_date": "2025-04-13T23:27:42.289000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "SEVD 2013-070-01",
            "trust": 0.8,
            "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01"
          },
          {
            "title": "Patch for Schneider Electric heap buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/44568"
          },
          {
            "title": "Schneider Electric Modbus Serial Driver Repair measures for stack-based buffer error vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=160424"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2014-02043"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-006276"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201404-005"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-119",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-60664"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-006276"
          },
          {
            "db": "NVD",
            "id": "CVE-2013-0662"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.1,
            "url": "http://ics-cert.us-cert.gov/advisories/icsa-14-086-01"
          },
          {
            "trust": 1.7,
            "url": "http://www.securityfocus.com/bid/66500"
          },
          {
            "trust": 1.7,
            "url": "http://download.schneider-electric.com/files?p_doc_ref=sevd%202013-070-01"
          },
          {
            "trust": 1.7,
            "url": "https://www.exploit-db.com/exploits/45219/"
          },
          {
            "trust": 1.7,
            "url": "https://www.exploit-db.com/exploits/45220/"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2013-0662"
          },
          {
            "trust": 0.8,
            "url": "http://ics-cert.us-cert.gov/advisories/icsa-14-086-01a"
          },
          {
            "trust": 0.8,
            "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2013-0662"
          },
          {
            "trust": 0.6,
            "url": "http://osvdb.com/show/osvdb/105035"
          },
          {
            "trust": 0.3,
            "url": "http://www.schneider-electric.com/site/home/index.cfm/ww/?selectcountry=true"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2014-02043"
          },
          {
            "db": "VULHUB",
            "id": "VHN-60664"
          },
          {
            "db": "BID",
            "id": "66500"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-006276"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201404-005"
          },
          {
            "db": "NVD",
            "id": "CVE-2013-0662"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "1cbd5cbc-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2014-02043"
          },
          {
            "db": "VULHUB",
            "id": "VHN-60664"
          },
          {
            "db": "BID",
            "id": "66500"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-006276"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201404-005"
          },
          {
            "db": "NVD",
            "id": "CVE-2013-0662"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2014-04-01T00:00:00",
            "db": "IVD",
            "id": "1cbd5cbc-2352-11e6-abef-000c29c66e3d"
          },
          {
            "date": "2014-04-01T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2014-02043"
          },
          {
            "date": "2014-04-01T00:00:00",
            "db": "VULHUB",
            "id": "VHN-60664"
          },
          {
            "date": "2014-03-27T00:00:00",
            "db": "BID",
            "id": "66500"
          },
          {
            "date": "2014-04-02T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2013-006276"
          },
          {
            "date": "2014-04-02T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201404-005"
          },
          {
            "date": "2014-04-01T06:17:08.240000",
            "db": "NVD",
            "id": "CVE-2013-0662"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2014-04-01T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2014-02043"
          },
          {
            "date": "2018-08-22T00:00:00",
            "db": "VULHUB",
            "id": "VHN-60664"
          },
          {
            "date": "2015-03-19T09:42:00",
            "db": "BID",
            "id": "66500"
          },
          {
            "date": "2014-04-02T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2013-006276"
          },
          {
            "date": "2022-02-07T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201404-005"
          },
          {
            "date": "2025-04-12T10:46:40.837000",
            "db": "NVD",
            "id": "CVE-2013-0662"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201404-005"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Schneider Electric Heap Buffer Overflow Vulnerability",
        "sources": [
          {
            "db": "IVD",
            "id": "1cbd5cbc-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2014-02043"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201404-005"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202012-0820

    Vulnerability from variot - Updated: 2024-11-23 22:58

    A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Modicon M258 Firmware (All versions prior to V5.0.4.11) and SoMachine/SoMachine Motion software (All versions), that could cause a buffer overflow when the length of a file transferred to the webserver is not verified. Modicon M258 firmware, SoMachine , SoMachine Motion The software contains a buffer error vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Schneider Electric Modicon M258 is a programmable automation controller produced by Schneider Electric in France

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202012-0820",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "somachine",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "*"
          },
          {
            "model": "somachine motion",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "*"
          },
          {
            "model": "modicon m258",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "5.0.4.11"
          },
          {
            "model": "somachine motion",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "modicon m258",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "somachine",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014347"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-28220"
          }
        ]
      },
      "cve": "CVE-2020-28220",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.2,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 5.1,
                "id": "CVE-2020-28220",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.2,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 5.1,
                "id": "VHN-372755",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:A/AC:L/AU:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 0.9,
                "id": "CVE-2020-28220",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 6.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2020-28220",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-28220",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-28220",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202012-936",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-372755",
                "trust": 0.1,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2020-28220",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-372755"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-28220"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014347"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-936"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-28220"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Modicon M258 Firmware (All versions prior to V5.0.4.11) and SoMachine/SoMachine Motion software (All versions), that could cause a buffer overflow when the length of a file transferred to the webserver is not verified. Modicon M258 firmware, SoMachine , SoMachine Motion The software contains a buffer error vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Schneider Electric Modicon M258 is a programmable automation controller produced by Schneider Electric in France",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-28220"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014347"
          },
          {
            "db": "VULHUB",
            "id": "VHN-372755"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-28220"
          }
        ],
        "trust": 1.8
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-28220",
            "trust": 2.6
          },
          {
            "db": "SCHNEIDER",
            "id": "SEVD-2020-343-09",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014347",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-936",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-372755",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-28220",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-372755"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-28220"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014347"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-936"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-28220"
          }
        ]
      },
      "id": "VAR-202012-0820",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-372755"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2024-11-23T22:58:05.905000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "SEVD-2020-343-09",
            "trust": 0.8,
            "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-09/"
          },
          {
            "title": "Schneider Electric Modicon M258 Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=136599"
          },
          {
            "title": "CVE-2020-28220",
            "trust": 0.1,
            "url": "https://github.com/AlAIAL90/CVE-2020-28220 "
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2020-28220"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014347"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-936"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.1
          },
          {
            "problemtype": "Buffer error (CWE-119) [ Other ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-372755"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014347"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-28220"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://www.se.com/ww/en/download/document/sevd-2020-343-09/"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-28220"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/119.html"
          },
          {
            "trust": 0.1,
            "url": "https://github.com/alaial90/cve-2020-28220"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-372755"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-28220"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014347"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-936"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-28220"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-372755"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-28220"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014347"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-936"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-28220"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-12-11T00:00:00",
            "db": "VULHUB",
            "id": "VHN-372755"
          },
          {
            "date": "2020-12-11T00:00:00",
            "db": "VULMON",
            "id": "CVE-2020-28220"
          },
          {
            "date": "2021-08-13T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-014347"
          },
          {
            "date": "2020-12-11T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202012-936"
          },
          {
            "date": "2020-12-11T01:15:11.940000",
            "db": "NVD",
            "id": "CVE-2020-28220"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-02-03T00:00:00",
            "db": "VULHUB",
            "id": "VHN-372755"
          },
          {
            "date": "2021-08-26T00:00:00",
            "db": "VULMON",
            "id": "CVE-2020-28220"
          },
          {
            "date": "2021-08-13T09:04:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-014347"
          },
          {
            "date": "2022-03-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202012-936"
          },
          {
            "date": "2024-11-21T05:22:29.963000",
            "db": "NVD",
            "id": "CVE-2020-28220"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-936"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0Schneider\u00a0Electric\u00a0 Buffer error vulnerability in the product",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014347"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-936"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202004-1857

    Vulnerability from variot - Updated: 2024-11-23 22:21

    A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers. plural Modicon The product contains vulnerabilities to inadequate validation of data reliability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Schneider Electric Modicon M218 Logic Controller, etc. are all programmable logic controllers of French Schneider Electric (Schneider Electric) company

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202004-1857",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "electric modicon m241",
            "scope": null,
            "trust": 1.2,
            "vendor": "schneider",
            "version": null
          },
          {
            "model": "somachine",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "*"
          },
          {
            "model": "somachine motion",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "*"
          },
          {
            "model": "ecostruxure machine expert",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "*"
          },
          {
            "model": "modicon m251",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "*"
          },
          {
            "model": "modicon m258",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "*"
          },
          {
            "model": "modicon m218",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "*"
          },
          {
            "model": "modicon m241",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "*"
          },
          {
            "model": "ecostruxure machine expert",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "modicon m218",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "modicon m241",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "modicon m251",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "modicon m258",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "somachine",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "somachine motion",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "electric modicon m218",
            "scope": null,
            "trust": 0.6,
            "vendor": "schneider",
            "version": null
          },
          {
            "model": "electric modicon m258",
            "scope": null,
            "trust": 0.6,
            "vendor": "schneider",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-25703"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004731"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-7487"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:ecostruxure_machine_expert",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:schneider_electric:modicon_M218_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:schneider_electric:modicon_m241_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:schneider_electric:modicon_m251_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:schneider_electric:modicon_m258_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:somachine",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:somachine_motion",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004731"
          }
        ]
      },
      "cve": "CVE-2020-7487",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2020-7487",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Partial",
                "baseScore": 7.5,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-004731",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2021-25703",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-185612",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2020-7487",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-004731",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-7487",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "JVNDB-2020-004731",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-25703",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202004-1944",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-185612",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-25703"
          },
          {
            "db": "VULHUB",
            "id": "VHN-185612"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004731"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1944"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-7487"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers. plural Modicon The product contains vulnerabilities to inadequate validation of data reliability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Schneider Electric Modicon M218 Logic Controller, etc. are all programmable logic controllers of French Schneider Electric (Schneider Electric) company",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-7487"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004731"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-25703"
          },
          {
            "db": "VULHUB",
            "id": "VHN-185612"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-7487",
            "trust": 3.1
          },
          {
            "db": "SCHNEIDER",
            "id": "SEVD-2020-105-02",
            "trust": 1.7
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004731",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-25703",
            "trust": 0.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1944",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-185612",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-25703"
          },
          {
            "db": "VULHUB",
            "id": "VHN-185612"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004731"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1944"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-7487"
          }
        ]
      },
      "id": "VAR-202004-1857",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-25703"
          },
          {
            "db": "VULHUB",
            "id": "VHN-185612"
          }
        ],
        "trust": 1.69675325
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-25703"
          }
        ]
      },
      "last_update_date": "2024-11-23T22:21:12.206000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "SEVD-2020-105-02",
            "trust": 0.8,
            "url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02/"
          },
          {
            "title": "Patch for Data forgery vulnerabilities in multiple Schneider Electric products",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/256506"
          },
          {
            "title": "Multiple Schneider Electric Product data falsification issues",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=117008"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-25703"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004731"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1944"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-345",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-185612"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004731"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-7487"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.0,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-7487"
          },
          {
            "trust": 1.7,
            "url": "https://www.se.com/ww/en/download/document/sevd-2020-105-02"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7487"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-25703"
          },
          {
            "db": "VULHUB",
            "id": "VHN-185612"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004731"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1944"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-7487"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-25703"
          },
          {
            "db": "VULHUB",
            "id": "VHN-185612"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004731"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1944"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-7487"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-04-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-25703"
          },
          {
            "date": "2020-04-22T00:00:00",
            "db": "VULHUB",
            "id": "VHN-185612"
          },
          {
            "date": "2020-05-26T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-004731"
          },
          {
            "date": "2020-04-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202004-1944"
          },
          {
            "date": "2020-04-22T19:15:11.653000",
            "db": "NVD",
            "id": "CVE-2020-7487"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-04-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-25703"
          },
          {
            "date": "2022-02-03T00:00:00",
            "db": "VULHUB",
            "id": "VHN-185612"
          },
          {
            "date": "2020-05-26T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-004731"
          },
          {
            "date": "2022-03-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202004-1944"
          },
          {
            "date": "2024-11-21T05:37:14.580000",
            "db": "NVD",
            "id": "CVE-2020-7487"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1944"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  Modicon Inadequate validation vulnerabilities for data reliability in products",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004731"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "data forgery",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1944"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202004-1858

    Vulnerability from variot - Updated: 2024-11-23 22:21

    A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers. Schneider Electric Modicon M218 Logic Controller, etc. are all programmable logic controllers of French Schneider Electric (Schneider Electric) company.

    There are security vulnerabilities in many Schneider Electric products

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202004-1858",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "somachine",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "*"
          },
          {
            "model": "somachine motion",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "*"
          },
          {
            "model": "ecostruxure machine expert",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "*"
          },
          {
            "model": "modicon m251",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "*"
          },
          {
            "model": "modicon m258",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "*"
          },
          {
            "model": "modicon m218",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "*"
          },
          {
            "model": "modicon m241",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "*"
          },
          {
            "model": "ecostruxure machine expert",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "modicon m218",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "modicon m241",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "modicon m251",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "modicon m258",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "somachine",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "somachine motion",
            "scope": null,
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "electric modicon m218",
            "scope": null,
            "trust": 0.6,
            "vendor": "schneider",
            "version": null
          },
          {
            "model": "electric modicon m251",
            "scope": null,
            "trust": 0.6,
            "vendor": "schneider",
            "version": null
          },
          {
            "model": "electric modicon m241",
            "scope": null,
            "trust": 0.6,
            "vendor": "schneider",
            "version": null
          },
          {
            "model": "electric modicon m258",
            "scope": null,
            "trust": 0.6,
            "vendor": "schneider",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-25704"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004650"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-7488"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:ecostruxure_machine_expert",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:schneider_electric:modicon_M218_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:schneider_electric:modicon_m241_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:schneider_electric:modicon_m251_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:schneider_electric:modicon_m258_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:somachine",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:schneider_electric:somachine_motion",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004650"
          }
        ]
      },
      "cve": "CVE-2020-7488",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2020-7488",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 5.0,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-004650",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2021-25704",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-185613",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2020-7488",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-004650",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-7488",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "JVNDB-2020-004650",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-25704",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202004-1945",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-185613",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-25704"
          },
          {
            "db": "VULHUB",
            "id": "VHN-185613"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004650"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1945"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-7488"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers. Schneider Electric Modicon M218 Logic Controller, etc. are all programmable logic controllers of French Schneider Electric (Schneider Electric) company. \n\r\n\r\nThere are security vulnerabilities in many Schneider Electric products",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-7488"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004650"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-25704"
          },
          {
            "db": "VULHUB",
            "id": "VHN-185613"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-7488",
            "trust": 3.1
          },
          {
            "db": "SCHNEIDER",
            "id": "SEVD-2020-105-02",
            "trust": 1.7
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004650",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1945",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-25704",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-185613",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-25704"
          },
          {
            "db": "VULHUB",
            "id": "VHN-185613"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004650"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1945"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-7488"
          }
        ]
      },
      "id": "VAR-202004-1858",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-25704"
          },
          {
            "db": "VULHUB",
            "id": "VHN-185613"
          }
        ],
        "trust": 1.69675325
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-25704"
          }
        ]
      },
      "last_update_date": "2024-11-23T22:21:12.174000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "SEVD-2020-105-02",
            "trust": 0.8,
            "url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02/"
          },
          {
            "title": "Patch for Unidentified vulnerabilities exist in many Schneider Electric products (CNVD-2021-25704)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/256501"
          },
          {
            "title": "Multiple Schneider Electric Product security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=117009"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-25704"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004650"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1945"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-319",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-185613"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004650"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-7488"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.0,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-7488"
          },
          {
            "trust": 1.7,
            "url": "https://www.se.com/ww/en/download/document/sevd-2020-105-02"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7488"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-25704"
          },
          {
            "db": "VULHUB",
            "id": "VHN-185613"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004650"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1945"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-7488"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-25704"
          },
          {
            "db": "VULHUB",
            "id": "VHN-185613"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004650"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1945"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-7488"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-04-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-25704"
          },
          {
            "date": "2020-04-22T00:00:00",
            "db": "VULHUB",
            "id": "VHN-185613"
          },
          {
            "date": "2020-05-25T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-004650"
          },
          {
            "date": "2020-04-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202004-1945"
          },
          {
            "date": "2020-04-22T19:15:11.717000",
            "db": "NVD",
            "id": "CVE-2020-7488"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-04-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-25704"
          },
          {
            "date": "2022-02-03T00:00:00",
            "db": "VULHUB",
            "id": "VHN-185613"
          },
          {
            "date": "2020-05-25T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-004650"
          },
          {
            "date": "2022-03-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202004-1945"
          },
          {
            "date": "2024-11-21T05:37:14.697000",
            "db": "NVD",
            "id": "CVE-2020-7488"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1945"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  Modicon Vulnerability in plaintext transmission of critical information in controller",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004650"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1945"
          }
        ],
        "trust": 0.6
      }
    }

    CVE-2014-9200 (GCVE-0-2014-9200)

    Vulnerability from nvd – Published: 2015-02-01 15:00 – Updated: 2025-09-05 21:34
    VLAI
    Title
    Schneider Electric Device Type Managers (DTMs) Stack-based Buffer Overflow
    Summary
    Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Date Public
    2015-01-27 07:00
    Credits
    Ariele Caltabiano (kimiya) with HP’s Zero Day Initiative (ZDI)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T13:40:24.488Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-009-01"
              },
              {
                "name": "72335",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/72335"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-027-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Unity Pro",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SoMachine",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SoMove",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SoMove Lite",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modbus Communication Library",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 2.2.6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CANopen Communication Library",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EtherNet/IP Communication Library",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EM X80 Gateway DTM (MB TCP/SL)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Advantys DTMs (OTB, STB)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "KINOS DTM",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SOLO DTM",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xantrex DTM",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Ariele Caltabiano (kimiya) with HP\u2019s Zero Day Initiative (ZDI)"
            }
          ],
          "datePublic": "2015-01-27T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eStack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors.\u003c/p\u003e"
                }
              ],
              "value": "Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors."
            }
          ],
          "metrics": [
            {
              "cvssV2_0": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-05T21:34:15.852Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-009-01"
            },
            {
              "name": "72335",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/72335"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-027-02"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eSchneider Electric has released a patch that resolves the \nvulnerability by removing the vulnerable DLL. Schneider Electric\u2019s patch\n is available at the follow location:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://download.schneider-electric.com/files?p_Doc_Ref=FDT1\"\u003ehttp://download.schneider-electric.com/files?p_Doc_Ref=FDT1\u003c/a\u003e DLL Removal Kit.\u003c/p\u003e\n\u003cp\u003eSchneider Electric\u2019s security notice SEVD-2015-009-01 is available at the following location:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-009-01\"\u003ehttp://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-009-01\u003c/a\u003e\u003c/p\u003e.\n\n\u003cbr\u003e"
                }
              ],
              "value": "Schneider Electric has released a patch that resolves the \nvulnerability by removing the vulnerable DLL. Schneider Electric\u2019s patch\n is available at the follow location:\n\n\n http://download.schneider-electric.com/files?p_Doc_Ref=FDT1  DLL Removal Kit.\n\n\nSchneider Electric\u2019s security notice SEVD-2015-009-01 is available at the following location:\n\n\n http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-009-01 \n\n."
            }
          ],
          "source": {
            "advisory": "ICSA-15-027-02",
            "discovery": "UNKNOWN"
          },
          "title": "Schneider Electric Device Type Managers (DTMs) Stack-based Buffer Overflow",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2014-9200",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-009-01",
                  "refsource": "CONFIRM",
                  "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-009-01"
                },
                {
                  "name": "72335",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/72335"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-027-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-027-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2014-9200",
        "datePublished": "2015-02-01T15:00:00.000Z",
        "dateReserved": "2014-12-02T00:00:00.000Z",
        "dateUpdated": "2025-09-05T21:34:15.852Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-9200 (GCVE-0-2014-9200)

    Vulnerability from cvelistv5 – Published: 2015-02-01 15:00 – Updated: 2025-09-05 21:34
    VLAI
    Title
    Schneider Electric Device Type Managers (DTMs) Stack-based Buffer Overflow
    Summary
    Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Date Public
    2015-01-27 07:00
    Credits
    Ariele Caltabiano (kimiya) with HP’s Zero Day Initiative (ZDI)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T13:40:24.488Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-009-01"
              },
              {
                "name": "72335",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/72335"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-027-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Unity Pro",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SoMachine",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SoMove",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SoMove Lite",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modbus Communication Library",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 2.2.6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CANopen Communication Library",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EtherNet/IP Communication Library",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EM X80 Gateway DTM (MB TCP/SL)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Advantys DTMs (OTB, STB)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "KINOS DTM",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SOLO DTM",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xantrex DTM",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Ariele Caltabiano (kimiya) with HP\u2019s Zero Day Initiative (ZDI)"
            }
          ],
          "datePublic": "2015-01-27T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eStack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors.\u003c/p\u003e"
                }
              ],
              "value": "Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors."
            }
          ],
          "metrics": [
            {
              "cvssV2_0": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-05T21:34:15.852Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-009-01"
            },
            {
              "name": "72335",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/72335"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-027-02"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eSchneider Electric has released a patch that resolves the \nvulnerability by removing the vulnerable DLL. Schneider Electric\u2019s patch\n is available at the follow location:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://download.schneider-electric.com/files?p_Doc_Ref=FDT1\"\u003ehttp://download.schneider-electric.com/files?p_Doc_Ref=FDT1\u003c/a\u003e DLL Removal Kit.\u003c/p\u003e\n\u003cp\u003eSchneider Electric\u2019s security notice SEVD-2015-009-01 is available at the following location:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-009-01\"\u003ehttp://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-009-01\u003c/a\u003e\u003c/p\u003e.\n\n\u003cbr\u003e"
                }
              ],
              "value": "Schneider Electric has released a patch that resolves the \nvulnerability by removing the vulnerable DLL. Schneider Electric\u2019s patch\n is available at the follow location:\n\n\n http://download.schneider-electric.com/files?p_Doc_Ref=FDT1  DLL Removal Kit.\n\n\nSchneider Electric\u2019s security notice SEVD-2015-009-01 is available at the following location:\n\n\n http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-009-01 \n\n."
            }
          ],
          "source": {
            "advisory": "ICSA-15-027-02",
            "discovery": "UNKNOWN"
          },
          "title": "Schneider Electric Device Type Managers (DTMs) Stack-based Buffer Overflow",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2014-9200",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-009-01",
                  "refsource": "CONFIRM",
                  "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-009-01"
                },
                {
                  "name": "72335",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/72335"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-027-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-027-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2014-9200",
        "datePublished": "2015-02-01T15:00:00.000Z",
        "dateReserved": "2014-12-02T00:00:00.000Z",
        "dateUpdated": "2025-09-05T21:34:15.852Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }