CVE-2026-35070 (GCVE-0-2026-35070)

Vulnerability from nvd – Published: 2026-05-20 09:23 – Updated: 2026-05-21 03:55
VLAI
Summary
Dell SmartFabric Storage Software, versions prior to 1.4.5, contains an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command (Command Injection)
Assigner
References
Impacted products
Vendor Product Version
Dell SmartFabric Storage Software Affected: 0 , < 1.4.5 or later (semver)
Create a notification for this product.
Date Public
2026-05-19 18:30
Credits
Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-35070",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-20T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-21T03:55:19.847Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SmartFabric Storage Software",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "1.4.5 or later",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue."
        }
      ],
      "datePublic": "2026-05-19T18:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell SmartFabric Storage Software, versions prior to 1.4.5, contains an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker."
            }
          ],
          "value": "Dell SmartFabric Storage Software, versions prior to 1.4.5, contains an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (Command Injection)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-20T09:23:25.819Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000466942/dsa-2026-235-security-update-for-dell-networking-smartfabric-storage-software-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2026-35070",
    "datePublished": "2026-05-20T09:23:25.819Z",
    "dateReserved": "2026-04-01T05:04:41.954Z",
    "dateUpdated": "2026-05-21T03:55:19.847Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-35070 (GCVE-0-2026-35070)

Vulnerability from cvelistv5 – Published: 2026-05-20 09:23 – Updated: 2026-05-21 03:55
VLAI
Summary
Dell SmartFabric Storage Software, versions prior to 1.4.5, contains an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command (Command Injection)
Assigner
References
Impacted products
Vendor Product Version
Dell SmartFabric Storage Software Affected: 0 , < 1.4.5 or later (semver)
Create a notification for this product.
Date Public
2026-05-19 18:30
Credits
Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-35070",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-20T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-21T03:55:19.847Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SmartFabric Storage Software",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "1.4.5 or later",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue."
        }
      ],
      "datePublic": "2026-05-19T18:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell SmartFabric Storage Software, versions prior to 1.4.5, contains an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker."
            }
          ],
          "value": "Dell SmartFabric Storage Software, versions prior to 1.4.5, contains an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (Command Injection)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-20T09:23:25.819Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000466942/dsa-2026-235-security-update-for-dell-networking-smartfabric-storage-software-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2026-35070",
    "datePublished": "2026-05-20T09:23:25.819Z",
    "dateReserved": "2026-04-01T05:04:41.954Z",
    "dateUpdated": "2026-05-21T03:55:19.847Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

VAR-202208-2251

Vulnerability from variot - Updated: 2024-08-14 14:37

SmartFabric storage software version 1.0.0 contains a Command-Injection vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability to gain access and perform actions on the affected system. Dell's smartfabric storage software for, OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202208-2251",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "smartfabric storage software",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "dell",
        "version": "1.0.0"
      },
      {
        "model": "smartfabric storage software",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "smartfabric storage software",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": "1.0.0"
      },
      {
        "model": "smartfabric storage software",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016357"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31232"
      }
    ]
  },
  "cve": "CVE-2022-31232",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-31232",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "security_alert@emc.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-31232",
            "impactScore": 4.7,
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-31232",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-31232",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "security_alert@emc.com",
            "id": "CVE-2022-31232",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-31232",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202208-4459",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016357"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4459"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31232"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31232"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "SmartFabric storage software version 1.0.0 contains a Command-Injection vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability to gain access and perform actions on the affected system. Dell\u0027s smartfabric storage software for, OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-31232"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016357"
      },
      {
        "db": "VULHUB",
        "id": "VHN-422928"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-31232"
      }
    ],
    "trust": 1.8
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-31232",
        "trust": 3.4
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016357",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4459",
        "trust": 0.7
      },
      {
        "db": "VULHUB",
        "id": "VHN-422928",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-31232",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-422928"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-31232"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016357"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4459"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31232"
      }
    ]
  },
  "id": "VAR-202208-2251",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-422928"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2024-08-14T14:37:19.818000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Dell SmartFabric Storage Software Fixes for operating system command injection vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=207793"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4459"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-78",
        "trust": 1.1
      },
      {
        "problemtype": "OS Command injection (CWE-78) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-422928"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016357"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31232"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://www.dell.com/support/kbdoc/en-us/000201667/dsa-2022-156-dell-emc-smartfabric-storage-software-security-update-for-multiple-component-vulnerabilities"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-31232"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-31232/"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-422928"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-31232"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016357"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4459"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31232"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-422928"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-31232"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016357"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4459"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31232"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-08-30T00:00:00",
        "db": "VULHUB",
        "id": "VHN-422928"
      },
      {
        "date": "2022-08-30T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-31232"
      },
      {
        "date": "2023-10-03T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-016357"
      },
      {
        "date": "2022-08-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-4459"
      },
      {
        "date": "2022-08-30T21:15:08.503000",
        "db": "NVD",
        "id": "CVE-2022-31232"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-09-08T00:00:00",
        "db": "VULHUB",
        "id": "VHN-422928"
      },
      {
        "date": "2022-08-30T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-31232"
      },
      {
        "date": "2023-10-03T08:09:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-016357"
      },
      {
        "date": "2022-09-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-4459"
      },
      {
        "date": "2022-09-08T03:25:35.507000",
        "db": "NVD",
        "id": "CVE-2022-31232"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4459"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Dell\u0027s \u00a0smartfabric\u00a0storage\u00a0software\u00a0 In \u00a0OS\u00a0 Command injection vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016357"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "operating system commend injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4459"
      }
    ],
    "trust": 0.6
  }
}