GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration
Search

Find a vulnerability

Search criteria

    7 vulnerabilities found for SmartFabric OS10 by Dell

    CVE-2026-63694 (GCVE-0-2026-63694)

    Vulnerability from nvd – Published: 2026-09-03 14:21 – Updated: 2026-09-04 03:56
    VLAI
    Summary
    Dell SmartFabric OS10 Software, versions prior to 10.5.6.14, contains an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-03 00:00 UTC
    CWE
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    References
    Impacted products
    Vendor Product Version
    Dell SmartFabric OS10 Affected: 0 , < 10.5.6.14 (semver)
    Create a notification for this product.
    Date Public
    2026-08-20 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-63694",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-03T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-04T03:56:02.784Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SmartFabric OS10",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "10.5.6.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "other",
              "value": "Dell would like to thank kkking for reporting this issue."
            }
          ],
          "datePublic": "2026-08-20T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell SmartFabric OS10 Software, versions prior to 10.5.6.14, contains an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution."
                }
              ],
              "value": "Dell SmartFabric OS10 Software, versions prior to 10.5.6.14, contains an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-03T14:21:44.965Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000501840/dsa-2026-322-security-update-for-dell-networking-os10-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2026-63694",
        "datePublished": "2026-09-03T14:21:44.965Z",
        "dateReserved": "2026-07-17T17:05:09.170Z",
        "dateUpdated": "2026-09-04T03:56:02.784Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-63694 (GCVE-0-2026-63694)

    Vulnerability from cvelistv5 – Published: 2026-09-03 14:21 – Updated: 2026-09-04 03:56
    VLAI
    Summary
    Dell SmartFabric OS10 Software, versions prior to 10.5.6.14, contains an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-03 00:00 UTC
    CWE
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    References
    Impacted products
    Vendor Product Version
    Dell SmartFabric OS10 Affected: 0 , < 10.5.6.14 (semver)
    Create a notification for this product.
    Date Public
    2026-08-20 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-63694",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-03T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-04T03:56:02.784Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SmartFabric OS10",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "10.5.6.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "other",
              "value": "Dell would like to thank kkking for reporting this issue."
            }
          ],
          "datePublic": "2026-08-20T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell SmartFabric OS10 Software, versions prior to 10.5.6.14, contains an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution."
                }
              ],
              "value": "Dell SmartFabric OS10 Software, versions prior to 10.5.6.14, contains an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-03T14:21:44.965Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000501840/dsa-2026-322-security-update-for-dell-networking-os10-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2026-63694",
        "datePublished": "2026-09-03T14:21:44.965Z",
        "dateReserved": "2026-07-17T17:05:09.170Z",
        "dateUpdated": "2026-09-04T03:56:02.784Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    VAR-202402-1924

    Vulnerability from variot - Updated: 2025-01-25 23:00

    Dell OS10 Networking Switches running 10.5.2.x and above contain an OS command injection vulnerability when using remote user authentication. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands and possible system takeover. This is a critical vulnerability as it allows an attacker to cause severe damage. Dell recommends customers to upgrade at the earliest opportunity. (DoS) It may be in a state. Dell OS10 Networking Switches is a switch made by the American company Dell

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202402-1924",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.5.1"
          },
          {
            "model": "smartfabric os10",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.2.12"
          },
          {
            "model": "smartfabric os10",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.4.0"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.5.2"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.5.3"
          },
          {
            "model": "smartfabric os10",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.3.0"
          },
          {
            "model": "smartfabric os10",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.4.8"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.5.0"
          },
          {
            "model": "smartfabric os10",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.3.8"
          },
          {
            "model": "smartfabric os10",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.2.0"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.5.3"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.5.2"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.3.0  that\u0027s all  10.5.3.8"
          },
          {
            "model": "smartfabric os10",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.5.0"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.5.1"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.2.0  that\u0027s all  10.5.2.12"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.4.0  that\u0027s all  10.5.4.8"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          },
          {
            "model": "os10 networking switches",
            "scope": "gte",
            "trust": 0.6,
            "vendor": "dell",
            "version": "10.5.2.*"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-11519"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-027961"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-32462"
          }
        ]
      },
      "cve": "CVE-2023-32462",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2024-11519",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "security_alert@emc.com",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2023-32462",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2023-32462",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "security_alert@emc.com",
                "id": "CVE-2023-32462",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2023-32462",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2023-32462",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2024-11519",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-11519"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-027961"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-32462"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-32462"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "\nDell OS10 Networking Switches running 10.5.2.x and above contain an OS command injection vulnerability when using remote user authentication. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands and possible system takeover. This is a critical vulnerability as it allows an attacker to cause severe damage. Dell recommends customers to upgrade at the earliest opportunity. (DoS) It may be in a state. Dell OS10 Networking Switches is a switch made by the American company Dell",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-32462"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-027961"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-11519"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-32462"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2023-32462",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-027961",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-11519",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-32462",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-11519"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-32462"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-027961"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-32462"
          }
        ]
      },
      "id": "VAR-202402-1924",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-11519"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-11519"
          }
        ]
      },
      "last_update_date": "2025-01-25T23:00:26.379000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Dell OS10 Networking Switches command execution vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/530056"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-11519"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-20",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-78",
            "trust": 1.0
          },
          {
            "problemtype": "Inappropriate input confirmation (CWE-20) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": "OS Command injection (CWE-78) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-027961"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-32462"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.9,
            "url": "https://www.dell.com/support/kbdoc/en-us/000216584/dsa-2023-124-security-update-for-dell-smartfabric-os10-multiple-vulnerabilities"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-32462"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2023-32462/"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/20.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-11519"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-32462"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-027961"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-32462"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-11519"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-32462"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-027961"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-32462"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-03-04T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-11519"
          },
          {
            "date": "2024-02-15T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-32462"
          },
          {
            "date": "2025-01-24T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2023-027961"
          },
          {
            "date": "2024-02-15T13:15:45.280000",
            "db": "NVD",
            "id": "CVE-2023-32462"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-03-04T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-11519"
          },
          {
            "date": "2024-02-15T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-32462"
          },
          {
            "date": "2025-01-24T05:04:00",
            "db": "JVNDB",
            "id": "JVNDB-2023-027961"
          },
          {
            "date": "2025-01-23T17:02:15.480000",
            "db": "NVD",
            "id": "CVE-2023-32462"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Dell\u0027s \u00a0smartfabric\u00a0os10\u00a0 In \u00a0OS\u00a0 Command injection vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-027961"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202402-1750

    Vulnerability from variot - Updated: 2025-01-25 22:51

    Dell OS10 Networking Switches running 10.5.2.x and above contain a vulnerability with zeroMQ when VLT is configured. A remote unauthenticated attacker could potentially exploit this vulnerability leading to information disclosure and a possible Denial of Service when a huge number of requests are sent to the switch. This is a high severity vulnerability as it allows an attacker to view sensitive data. Dell recommends customers to upgrade at the earliest opportunity. Dell's smartfabric os10 Exists in unspecified vulnerabilities.Information is obtained and service operation is interrupted (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202402-1750",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.5.1"
          },
          {
            "model": "smartfabric os10",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.2.12"
          },
          {
            "model": "smartfabric os10",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.4.0"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.5.2"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.5.3"
          },
          {
            "model": "smartfabric os10",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.3.0"
          },
          {
            "model": "smartfabric os10",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.4.8"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.5.0"
          },
          {
            "model": "smartfabric os10",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.3.8"
          },
          {
            "model": "smartfabric os10",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.2.0"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.5.3"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.5.2"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.3.0  that\u0027s all  10.5.3.8"
          },
          {
            "model": "smartfabric os10",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.5.0"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.5.1"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.2.0  that\u0027s all  10.5.2.12"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.4.0  that\u0027s all  10.5.4.8"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          },
          {
            "model": "os10 networking switches",
            "scope": "gte",
            "trust": 0.6,
            "vendor": "dell",
            "version": "10.5.2.*"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-11520"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-027950"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-28078"
          }
        ]
      },
      "cve": "CVE-2023-28078",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.4,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2024-11520",
                "impactScore": 9.2,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "security_alert@emc.com",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2023-28078",
                "impactScore": 5.2,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.1,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2023-28078",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "security_alert@emc.com",
                "id": "CVE-2023-28078",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2023-28078",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2023-28078",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2024-11520",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-11520"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-027950"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-28078"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-28078"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "\nDell OS10 Networking Switches running 10.5.2.x and above contain a vulnerability with zeroMQ when VLT is configured. A remote unauthenticated attacker could potentially exploit this vulnerability leading to information disclosure and a possible Denial of Service when a huge number of requests are sent to the switch. This is a high severity vulnerability as it allows an attacker to view sensitive data. Dell recommends customers to upgrade at the earliest opportunity. Dell\u0027s smartfabric os10 Exists in unspecified vulnerabilities.Information is obtained and service operation is interrupted (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-28078"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-027950"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-11520"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-28078"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2023-28078",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-027950",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-11520",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-28078",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-11520"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-28078"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-027950"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-28078"
          }
        ]
      },
      "id": "VAR-202402-1750",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-11520"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-11520"
          }
        ]
      },
      "last_update_date": "2025-01-25T22:51:41.774000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Dell OS10 Networking Switches information leakage vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/530051"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-11520"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-923",
            "trust": 1.0
          },
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "Improper restriction of communication channels with intended endpoints (CWE-923) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Lack of information (CWE-noinfo) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-027950"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-28078"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.9,
            "url": "https://www.dell.com/support/kbdoc/en-us/000216584/dsa-2023-124-security-update-for-dell-smartfabric-os10-multiple-vulnerabilities"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-28078"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2023-28078/"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/923.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-11520"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-28078"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-027950"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-28078"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-11520"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-28078"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-027950"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-28078"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-03-04T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-11520"
          },
          {
            "date": "2024-02-15T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-28078"
          },
          {
            "date": "2025-01-24T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2023-027950"
          },
          {
            "date": "2024-02-15T13:15:44.607000",
            "db": "NVD",
            "id": "CVE-2023-28078"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-03-04T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-11520"
          },
          {
            "date": "2024-02-15T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-28078"
          },
          {
            "date": "2025-01-24T01:44:00",
            "db": "JVNDB",
            "id": "JVNDB-2023-027950"
          },
          {
            "date": "2025-01-23T17:03:49.193000",
            "db": "NVD",
            "id": "CVE-2023-28078"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Dell\u0027s \u00a0smartfabric\u00a0os10\u00a0 Vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-027950"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202209-1911

    Vulnerability from variot - Updated: 2024-08-14 15:32

    Dell OS10, version 10.5.3.4, contains an Improper Certificate Validation vulnerability in Support Assist. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to unauthorized access to limited switch configuration data. The vulnerability could be leveraged by attackers to conduct man-in-the-middle attacks to gain access to the Support Assist information. Dell's smartfabric os10 Exists in a certificate validation vulnerability.Information may be obtained. Dell SmartFabric OS10 is a Linux-based network switch operating system developed by Dell. Dell SmartFabric OS10 versions prior to 1010.5.1.11 have a security vulnerability

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202209-1911",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.3.4"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.3.4"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          },
          {
            "model": "smartfabric os10",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018119"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34394"
          }
        ]
      },
      "cve": "CVE-2022-34394",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 3.7,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 2.2,
                "id": "CVE-2022-34394",
                "impactScore": 1.4,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "High",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 3.7,
                "baseSeverity": "Low",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "CVE-2022-34394",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-34394",
                "trust": 1.0,
                "value": "LOW"
              },
              {
                "author": "security_alert@emc.com",
                "id": "CVE-2022-34394",
                "trust": 1.0,
                "value": "LOW"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-34394",
                "trust": 0.8,
                "value": "Low"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202209-2908",
                "trust": 0.6,
                "value": "LOW"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018119"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2908"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34394"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34394"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Dell OS10, version 10.5.3.4, contains an Improper Certificate Validation vulnerability in Support Assist. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to unauthorized access to limited switch configuration data. The vulnerability could be leveraged by attackers to conduct man-in-the-middle attacks to gain access to the Support Assist information. Dell\u0027s smartfabric os10 Exists in a certificate validation vulnerability.Information may be obtained. Dell SmartFabric OS10 is a Linux-based network switch operating system developed by Dell. Dell SmartFabric OS10 versions prior to 1010.5.1.11 have a security vulnerability",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-34394"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018119"
          },
          {
            "db": "VULHUB",
            "id": "VHN-426710"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-34394",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018119",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2908",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-69150",
            "trust": 0.1
          },
          {
            "db": "VULHUB",
            "id": "VHN-426710",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426710"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018119"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2908"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34394"
          }
        ]
      },
      "id": "VAR-202209-1911",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426710"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2024-08-14T15:32:31.536000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Dell SmartFabric OS10 Repair measures for trust management problem vulnerabilities",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=209701"
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2908"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-295",
            "trust": 1.1
          },
          {
            "problemtype": "Illegal certificate verification (CWE-295) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426710"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018119"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34394"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.5,
            "url": "https://www.dell.com/support/kbdoc/en-us/000202974/dsa-2022-293-dell-networking-os10-security-update-for-a-support-assist-vulnerability"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-34394"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-34394/"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426710"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018119"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2908"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34394"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-426710"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018119"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2908"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34394"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-09-28T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426710"
          },
          {
            "date": "2023-10-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-018119"
          },
          {
            "date": "2022-09-28T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202209-2908"
          },
          {
            "date": "2022-09-28T21:15:12.897000",
            "db": "NVD",
            "id": "CVE-2022-34394"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-09-30T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426710"
          },
          {
            "date": "2023-10-18T08:11:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-018119"
          },
          {
            "date": "2022-10-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202209-2908"
          },
          {
            "date": "2022-09-30T17:20:10.670000",
            "db": "NVD",
            "id": "CVE-2022-34394"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2908"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Dell\u0027s \u00a0smartfabric\u00a0os10\u00a0 Certificate validation vulnerabilities in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018119"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "trust management problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2908"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202209-1935

    Vulnerability from variot - Updated: 2024-08-14 15:11

    Dell Networking OS10, versions prior to October 2021 with Smart Fabric Services enabled, contains an information disclosure vulnerability. A remote, unauthenticated attacker could potentially exploit this vulnerability by reverse engineering to retrieve sensitive information and access the REST API with admin privileges. Dell's smartfabric os10 There are vulnerabilities in inadequate protection of credentials.Information may be obtained. Dell SmartFabric OS10 is a Linux-based network switch operating system developed by Dell

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202209-1935",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "smartfabric os10",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.2.11"
          },
          {
            "model": "smartfabric os10",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.3.5"
          },
          {
            "model": "smartfabric os10",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.1.11"
          },
          {
            "model": "smartfabric os10",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.3.0"
          },
          {
            "model": "smartfabric os10",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.1.0"
          },
          {
            "model": "smartfabric os10",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.2.0"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.3.0  that\u0027s all  10.5.3.5"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.1.0  that\u0027s all  10.5.1.11"
          },
          {
            "model": "smartfabric os10",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.2.0  that\u0027s all  10.5.2.11"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018149"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-29089"
          }
        ]
      },
      "cve": "CVE-2022-29089",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 4.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.2,
                "id": "CVE-2022-29089",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "HIGH",
                "attackVector": "ADJACENT",
                "author": "security_alert@emc.com",
                "availabilityImpact": "HIGH",
                "baseScore": 6.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 1.6,
                "id": "CVE-2022-29089",
                "impactScore": 4.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 4.9,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2022-29089",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-29089",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "security_alert@emc.com",
                "id": "CVE-2022-29089",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-29089",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202209-2910",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018149"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2910"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-29089"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-29089"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Dell Networking OS10, versions prior to October 2021 with Smart Fabric Services enabled, contains an information disclosure vulnerability. A remote, unauthenticated attacker could potentially exploit this vulnerability by reverse engineering to retrieve sensitive information and access the REST API with admin privileges. Dell\u0027s smartfabric os10 There are vulnerabilities in inadequate protection of credentials.Information may be obtained. Dell SmartFabric OS10 is a Linux-based network switch operating system developed by Dell",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-29089"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018149"
          },
          {
            "db": "VULHUB",
            "id": "VHN-420623"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-29089",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018149",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2910",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-420623",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-420623"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018149"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2910"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-29089"
          }
        ]
      },
      "id": "VAR-202209-1935",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-420623"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2024-08-14T15:11:15.385000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Dell SmartFabric OS10 Repair measures for information disclosure vulnerabilities",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=209702"
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2910"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-522",
            "trust": 1.1
          },
          {
            "problemtype": "Inadequate protection of credentials (CWE-522) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-420623"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018149"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-29089"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.5,
            "url": "https://www.dell.com/support/kbdoc/en-us/000202971/dsa-2022-135-dell-emc-smartfabric-os10-security-update-for-multiple-security-vulnerabilities"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-29089"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-29089/"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-420623"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018149"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2910"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-29089"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-420623"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018149"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2910"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-29089"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-09-28T00:00:00",
            "db": "VULHUB",
            "id": "VHN-420623"
          },
          {
            "date": "2023-10-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-018149"
          },
          {
            "date": "2022-09-28T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202209-2910"
          },
          {
            "date": "2022-09-28T21:15:09.880000",
            "db": "NVD",
            "id": "CVE-2022-29089"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-09-30T00:00:00",
            "db": "VULHUB",
            "id": "VHN-420623"
          },
          {
            "date": "2023-10-18T08:12:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-018149"
          },
          {
            "date": "2022-10-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202209-2910"
          },
          {
            "date": "2022-09-30T17:16:40.670000",
            "db": "NVD",
            "id": "CVE-2022-29089"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2910"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Dell\u0027s \u00a0smartfabric\u00a0os10\u00a0 Vulnerability regarding insufficient protection of authentication information in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018149"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "information disclosure",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2910"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202209-2002

    Vulnerability from variot - Updated: 2024-08-14 14:37

    Networking OS10, versions 10.5.1.x, 10.5.2.x, and 10.5.3.x contain a vulnerability that could allow an attacker to cause a system crash by running particular security scans. Dell's smartfabric os10 Exists in an out-of-bounds write vulnerability.Service operation interruption (DoS) It may be in a state. Dell SmartFabric OS10 is a Linux-based network switch operating system developed by Dell

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202209-2002",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "smartfabric os10",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.2.11"
          },
          {
            "model": "smartfabric os10",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.3.5"
          },
          {
            "model": "smartfabric os10",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.1.11"
          },
          {
            "model": "smartfabric os10",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.3.0"
          },
          {
            "model": "smartfabric os10",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.1.0"
          },
          {
            "model": "smartfabric os10",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "dell",
            "version": "10.5.2.0"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.3.0  that\u0027s all  10.5.3.5"
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.1.0  that\u0027s all  10.5.1.11"
          },
          {
            "model": "smartfabric os10",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          },
          {
            "model": "smartfabric os10",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "10.5.2.0  that\u0027s all  10.5.2.11"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018118"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34424"
          }
        ]
      },
      "cve": "CVE-2022-34424",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-34424",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2022-34424",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-34424",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "security_alert@emc.com",
                "id": "CVE-2022-34424",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-34424",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202209-2907",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018118"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2907"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34424"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34424"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Networking OS10, versions 10.5.1.x, 10.5.2.x, and 10.5.3.x contain a vulnerability that could allow an attacker to cause a system crash by running particular security scans. Dell\u0027s smartfabric os10 Exists in an out-of-bounds write vulnerability.Service operation interruption (DoS) It may be in a state. Dell SmartFabric OS10 is a Linux-based network switch operating system developed by Dell",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-34424"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018118"
          },
          {
            "db": "VULHUB",
            "id": "VHN-426740"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-34424",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018118",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2907",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-426740",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426740"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018118"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2907"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34424"
          }
        ]
      },
      "id": "VAR-202209-2002",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426740"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2024-08-14T14:37:17.542000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Dell SmartFabric OS10 Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=209700"
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2907"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.1
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426740"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018118"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34424"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.5,
            "url": "https://www.dell.com/support/kbdoc/en-us/000202971/dsa-2022-135-dell-emc-smartfabric-os10-security-update-for-multiple-security-vulnerabilities"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-34424"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-34424/"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426740"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018118"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2907"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34424"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-426740"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018118"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2907"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34424"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-09-28T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426740"
          },
          {
            "date": "2023-10-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-018118"
          },
          {
            "date": "2022-09-28T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202209-2907"
          },
          {
            "date": "2022-09-28T21:15:13.337000",
            "db": "NVD",
            "id": "CVE-2022-34424"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-09-30T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426740"
          },
          {
            "date": "2023-10-18T08:11:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-018118"
          },
          {
            "date": "2022-10-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202209-2907"
          },
          {
            "date": "2022-09-30T02:18:02.300000",
            "db": "NVD",
            "id": "CVE-2022-34424"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2907"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Dell\u0027s \u00a0smartfabric\u00a0os10\u00a0 Out-of-bounds write vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-018118"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-2907"
          }
        ],
        "trust": 0.6
      }
    }