Find a vulnerability
Search criteria
7 vulnerabilities found for SmartFabric OS10 by Dell
CVE-2026-63694 (GCVE-0-2026-63694)
Vulnerability from nvd – Published: 2026-09-03 14:21 – Updated: 2026-09-04 03:56- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00050184… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | SmartFabric OS10 |
Affected:
0 , < 10.5.6.14
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-63694",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-03T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-04T03:56:02.784Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SmartFabric OS10",
"vendor": "Dell",
"versions": [
{
"lessThan": "10.5.6.14",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank kkking for reporting this issue."
}
],
"datePublic": "2026-08-20T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell SmartFabric OS10 Software, versions prior to 10.5.6.14, contains an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution."
}
],
"value": "Dell SmartFabric OS10 Software, versions prior to 10.5.6.14, contains an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-03T14:21:44.965Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000501840/dsa-2026-322-security-update-for-dell-networking-os10-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-63694",
"datePublished": "2026-09-03T14:21:44.965Z",
"dateReserved": "2026-07-17T17:05:09.170Z",
"dateUpdated": "2026-09-04T03:56:02.784Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-63694 (GCVE-0-2026-63694)
Vulnerability from cvelistv5 – Published: 2026-09-03 14:21 – Updated: 2026-09-04 03:56- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00050184… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | SmartFabric OS10 |
Affected:
0 , < 10.5.6.14
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-63694",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-03T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-04T03:56:02.784Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SmartFabric OS10",
"vendor": "Dell",
"versions": [
{
"lessThan": "10.5.6.14",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank kkking for reporting this issue."
}
],
"datePublic": "2026-08-20T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell SmartFabric OS10 Software, versions prior to 10.5.6.14, contains an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution."
}
],
"value": "Dell SmartFabric OS10 Software, versions prior to 10.5.6.14, contains an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-03T14:21:44.965Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000501840/dsa-2026-322-security-update-for-dell-networking-os10-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-63694",
"datePublished": "2026-09-03T14:21:44.965Z",
"dateReserved": "2026-07-17T17:05:09.170Z",
"dateUpdated": "2026-09-04T03:56:02.784Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
VAR-202402-1924
Vulnerability from variot - Updated: 2025-01-25 23:00Dell OS10 Networking Switches running 10.5.2.x and above contain an OS command injection vulnerability when using remote user authentication. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands and possible system takeover. This is a critical vulnerability as it allows an attacker to cause severe damage. Dell recommends customers to upgrade at the earliest opportunity. (DoS) It may be in a state. Dell OS10 Networking Switches is a switch made by the American company Dell
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202402-1924",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.5.1"
},
{
"model": "smartfabric os10",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.2.12"
},
{
"model": "smartfabric os10",
"scope": "gte",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.4.0"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.5.2"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.5.3"
},
{
"model": "smartfabric os10",
"scope": "gte",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.3.0"
},
{
"model": "smartfabric os10",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.4.8"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.5.0"
},
{
"model": "smartfabric os10",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.3.8"
},
{
"model": "smartfabric os10",
"scope": "gte",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.2.0"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.5.3"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.5.2"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.3.0 that\u0027s all 10.5.3.8"
},
{
"model": "smartfabric os10",
"scope": null,
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.5.0"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.5.1"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.2.0 that\u0027s all 10.5.2.12"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.4.0 that\u0027s all 10.5.4.8"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "os10 networking switches",
"scope": "gte",
"trust": 0.6,
"vendor": "dell",
"version": "10.5.2.*"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-11519"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-027961"
},
{
"db": "NVD",
"id": "CVE-2023-32462"
}
]
},
"cve": "CVE-2023-32462",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-11519",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "security_alert@emc.com",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-32462",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-32462",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "security_alert@emc.com",
"id": "CVE-2023-32462",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2023-32462",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-32462",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2024-11519",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-11519"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-027961"
},
{
"db": "NVD",
"id": "CVE-2023-32462"
},
{
"db": "NVD",
"id": "CVE-2023-32462"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "\nDell OS10 Networking Switches running 10.5.2.x and above contain an OS command injection vulnerability when using remote user authentication. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands and possible system takeover. This is a critical vulnerability as it allows an attacker to cause severe damage. Dell recommends customers to upgrade at the earliest opportunity. (DoS) It may be in a state. Dell OS10 Networking Switches is a switch made by the American company Dell",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-32462"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-027961"
},
{
"db": "CNVD",
"id": "CNVD-2024-11519"
},
{
"db": "VULMON",
"id": "CVE-2023-32462"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-32462",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-027961",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-11519",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-32462",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-11519"
},
{
"db": "VULMON",
"id": "CVE-2023-32462"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-027961"
},
{
"db": "NVD",
"id": "CVE-2023-32462"
}
]
},
"id": "VAR-202402-1924",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-11519"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-11519"
}
]
},
"last_update_date": "2025-01-25T23:00:26.379000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Dell OS10 Networking Switches command execution vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/530056"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-11519"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-20",
"trust": 1.0
},
{
"problemtype": "CWE-78",
"trust": 1.0
},
{
"problemtype": "Inappropriate input confirmation (CWE-20) [ others ]",
"trust": 0.8
},
{
"problemtype": "OS Command injection (CWE-78) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-027961"
},
{
"db": "NVD",
"id": "CVE-2023-32462"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.9,
"url": "https://www.dell.com/support/kbdoc/en-us/000216584/dsa-2023-124-security-update-for-dell-smartfabric-os10-multiple-vulnerabilities"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-32462"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-32462/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-11519"
},
{
"db": "VULMON",
"id": "CVE-2023-32462"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-027961"
},
{
"db": "NVD",
"id": "CVE-2023-32462"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-11519"
},
{
"db": "VULMON",
"id": "CVE-2023-32462"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-027961"
},
{
"db": "NVD",
"id": "CVE-2023-32462"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-11519"
},
{
"date": "2024-02-15T00:00:00",
"db": "VULMON",
"id": "CVE-2023-32462"
},
{
"date": "2025-01-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-027961"
},
{
"date": "2024-02-15T13:15:45.280000",
"db": "NVD",
"id": "CVE-2023-32462"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-11519"
},
{
"date": "2024-02-15T00:00:00",
"db": "VULMON",
"id": "CVE-2023-32462"
},
{
"date": "2025-01-24T05:04:00",
"db": "JVNDB",
"id": "JVNDB-2023-027961"
},
{
"date": "2025-01-23T17:02:15.480000",
"db": "NVD",
"id": "CVE-2023-32462"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell\u0027s \u00a0smartfabric\u00a0os10\u00a0 In \u00a0OS\u00a0 Command injection vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-027961"
}
],
"trust": 0.8
}
}
VAR-202402-1750
Vulnerability from variot - Updated: 2025-01-25 22:51Dell OS10 Networking Switches running 10.5.2.x and above contain a vulnerability with zeroMQ when VLT is configured. A remote unauthenticated attacker could potentially exploit this vulnerability leading to information disclosure and a possible Denial of Service when a huge number of requests are sent to the switch. This is a high severity vulnerability as it allows an attacker to view sensitive data. Dell recommends customers to upgrade at the earliest opportunity. Dell's smartfabric os10 Exists in unspecified vulnerabilities.Information is obtained and service operation is interrupted (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202402-1750",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.5.1"
},
{
"model": "smartfabric os10",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.2.12"
},
{
"model": "smartfabric os10",
"scope": "gte",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.4.0"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.5.2"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.5.3"
},
{
"model": "smartfabric os10",
"scope": "gte",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.3.0"
},
{
"model": "smartfabric os10",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.4.8"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.5.0"
},
{
"model": "smartfabric os10",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.3.8"
},
{
"model": "smartfabric os10",
"scope": "gte",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.2.0"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.5.3"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.5.2"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.3.0 that\u0027s all 10.5.3.8"
},
{
"model": "smartfabric os10",
"scope": null,
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.5.0"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.5.1"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.2.0 that\u0027s all 10.5.2.12"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.4.0 that\u0027s all 10.5.4.8"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "os10 networking switches",
"scope": "gte",
"trust": 0.6,
"vendor": "dell",
"version": "10.5.2.*"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-11520"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-027950"
},
{
"db": "NVD",
"id": "CVE-2023-28078"
}
]
},
"cve": "CVE-2023-28078",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.4,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-11520",
"impactScore": 9.2,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "security_alert@emc.com",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-28078",
"impactScore": 5.2,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.1,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-28078",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "security_alert@emc.com",
"id": "CVE-2023-28078",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2023-28078",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-28078",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2024-11520",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-11520"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-027950"
},
{
"db": "NVD",
"id": "CVE-2023-28078"
},
{
"db": "NVD",
"id": "CVE-2023-28078"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "\nDell OS10 Networking Switches running 10.5.2.x and above contain a vulnerability with zeroMQ when VLT is configured. A remote unauthenticated attacker could potentially exploit this vulnerability leading to information disclosure and a possible Denial of Service when a huge number of requests are sent to the switch. This is a high severity vulnerability as it allows an attacker to view sensitive data. Dell recommends customers to upgrade at the earliest opportunity. Dell\u0027s smartfabric os10 Exists in unspecified vulnerabilities.Information is obtained and service operation is interrupted (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-28078"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-027950"
},
{
"db": "CNVD",
"id": "CNVD-2024-11520"
},
{
"db": "VULMON",
"id": "CVE-2023-28078"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-28078",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-027950",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-11520",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-28078",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-11520"
},
{
"db": "VULMON",
"id": "CVE-2023-28078"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-027950"
},
{
"db": "NVD",
"id": "CVE-2023-28078"
}
]
},
"id": "VAR-202402-1750",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-11520"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-11520"
}
]
},
"last_update_date": "2025-01-25T22:51:41.774000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Dell OS10 Networking Switches information leakage vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/530051"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-11520"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-923",
"trust": 1.0
},
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "Improper restriction of communication channels with intended endpoints (CWE-923) [ others ]",
"trust": 0.8
},
{
"problemtype": " Lack of information (CWE-noinfo) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-027950"
},
{
"db": "NVD",
"id": "CVE-2023-28078"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.9,
"url": "https://www.dell.com/support/kbdoc/en-us/000216584/dsa-2023-124-security-update-for-dell-smartfabric-os10-multiple-vulnerabilities"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-28078"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-28078/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/923.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-11520"
},
{
"db": "VULMON",
"id": "CVE-2023-28078"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-027950"
},
{
"db": "NVD",
"id": "CVE-2023-28078"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-11520"
},
{
"db": "VULMON",
"id": "CVE-2023-28078"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-027950"
},
{
"db": "NVD",
"id": "CVE-2023-28078"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-11520"
},
{
"date": "2024-02-15T00:00:00",
"db": "VULMON",
"id": "CVE-2023-28078"
},
{
"date": "2025-01-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-027950"
},
{
"date": "2024-02-15T13:15:44.607000",
"db": "NVD",
"id": "CVE-2023-28078"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-11520"
},
{
"date": "2024-02-15T00:00:00",
"db": "VULMON",
"id": "CVE-2023-28078"
},
{
"date": "2025-01-24T01:44:00",
"db": "JVNDB",
"id": "JVNDB-2023-027950"
},
{
"date": "2025-01-23T17:03:49.193000",
"db": "NVD",
"id": "CVE-2023-28078"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell\u0027s \u00a0smartfabric\u00a0os10\u00a0 Vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-027950"
}
],
"trust": 0.8
}
}
VAR-202209-1911
Vulnerability from variot - Updated: 2024-08-14 15:32Dell OS10, version 10.5.3.4, contains an Improper Certificate Validation vulnerability in Support Assist. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to unauthorized access to limited switch configuration data. The vulnerability could be leveraged by attackers to conduct man-in-the-middle attacks to gain access to the Support Assist information. Dell's smartfabric os10 Exists in a certificate validation vulnerability.Information may be obtained. Dell SmartFabric OS10 is a Linux-based network switch operating system developed by Dell. Dell SmartFabric OS10 versions prior to 1010.5.1.11 have a security vulnerability
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202209-1911",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.3.4"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.3.4"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "smartfabric os10",
"scope": null,
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018119"
},
{
"db": "NVD",
"id": "CVE-2022-34394"
}
]
},
"cve": "CVE-2022-34394",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.2,
"id": "CVE-2022-34394",
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "High",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 3.7,
"baseSeverity": "Low",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "CVE-2022-34394",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-34394",
"trust": 1.0,
"value": "LOW"
},
{
"author": "security_alert@emc.com",
"id": "CVE-2022-34394",
"trust": 1.0,
"value": "LOW"
},
{
"author": "NVD",
"id": "CVE-2022-34394",
"trust": 0.8,
"value": "Low"
},
{
"author": "CNNVD",
"id": "CNNVD-202209-2908",
"trust": 0.6,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018119"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2908"
},
{
"db": "NVD",
"id": "CVE-2022-34394"
},
{
"db": "NVD",
"id": "CVE-2022-34394"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell OS10, version 10.5.3.4, contains an Improper Certificate Validation vulnerability in Support Assist. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to unauthorized access to limited switch configuration data. The vulnerability could be leveraged by attackers to conduct man-in-the-middle attacks to gain access to the Support Assist information. Dell\u0027s smartfabric os10 Exists in a certificate validation vulnerability.Information may be obtained. Dell SmartFabric OS10 is a Linux-based network switch operating system developed by Dell. Dell SmartFabric OS10 versions prior to 1010.5.1.11 have a security vulnerability",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-34394"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018119"
},
{
"db": "VULHUB",
"id": "VHN-426710"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-34394",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018119",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2908",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2022-69150",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-426710",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426710"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018119"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2908"
},
{
"db": "NVD",
"id": "CVE-2022-34394"
}
]
},
"id": "VAR-202209-1911",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-426710"
}
],
"trust": 0.01
},
"last_update_date": "2024-08-14T15:32:31.536000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Dell SmartFabric OS10 Repair measures for trust management problem vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=209701"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2908"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-295",
"trust": 1.1
},
{
"problemtype": "Illegal certificate verification (CWE-295) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426710"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018119"
},
{
"db": "NVD",
"id": "CVE-2022-34394"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://www.dell.com/support/kbdoc/en-us/000202974/dsa-2022-293-dell-networking-os10-security-update-for-a-support-assist-vulnerability"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-34394"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-34394/"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426710"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018119"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2908"
},
{
"db": "NVD",
"id": "CVE-2022-34394"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-426710"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018119"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2908"
},
{
"db": "NVD",
"id": "CVE-2022-34394"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-09-28T00:00:00",
"db": "VULHUB",
"id": "VHN-426710"
},
{
"date": "2023-10-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-018119"
},
{
"date": "2022-09-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2908"
},
{
"date": "2022-09-28T21:15:12.897000",
"db": "NVD",
"id": "CVE-2022-34394"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-09-30T00:00:00",
"db": "VULHUB",
"id": "VHN-426710"
},
{
"date": "2023-10-18T08:11:00",
"db": "JVNDB",
"id": "JVNDB-2022-018119"
},
{
"date": "2022-10-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2908"
},
{
"date": "2022-09-30T17:20:10.670000",
"db": "NVD",
"id": "CVE-2022-34394"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2908"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell\u0027s \u00a0smartfabric\u00a0os10\u00a0 Certificate validation vulnerabilities in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018119"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2908"
}
],
"trust": 0.6
}
}
VAR-202209-1935
Vulnerability from variot - Updated: 2024-08-14 15:11Dell Networking OS10, versions prior to October 2021 with Smart Fabric Services enabled, contains an information disclosure vulnerability. A remote, unauthenticated attacker could potentially exploit this vulnerability by reverse engineering to retrieve sensitive information and access the REST API with admin privileges. Dell's smartfabric os10 There are vulnerabilities in inadequate protection of credentials.Information may be obtained. Dell SmartFabric OS10 is a Linux-based network switch operating system developed by Dell
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202209-1935",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "smartfabric os10",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.2.11"
},
{
"model": "smartfabric os10",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.3.5"
},
{
"model": "smartfabric os10",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.1.11"
},
{
"model": "smartfabric os10",
"scope": "gte",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.3.0"
},
{
"model": "smartfabric os10",
"scope": "gte",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.1.0"
},
{
"model": "smartfabric os10",
"scope": "gte",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.2.0"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.3.0 that\u0027s all 10.5.3.5"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.1.0 that\u0027s all 10.5.1.11"
},
{
"model": "smartfabric os10",
"scope": null,
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.2.0 that\u0027s all 10.5.2.11"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018149"
},
{
"db": "NVD",
"id": "CVE-2022-29089"
}
]
},
"cve": "CVE-2022-29089",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.2,
"id": "CVE-2022-29089",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "HIGH",
"attackVector": "ADJACENT",
"author": "security_alert@emc.com",
"availabilityImpact": "HIGH",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 1.6,
"id": "CVE-2022-29089",
"impactScore": 4.7,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.9,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-29089",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-29089",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "security_alert@emc.com",
"id": "CVE-2022-29089",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2022-29089",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNNVD",
"id": "CNNVD-202209-2910",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018149"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2910"
},
{
"db": "NVD",
"id": "CVE-2022-29089"
},
{
"db": "NVD",
"id": "CVE-2022-29089"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell Networking OS10, versions prior to October 2021 with Smart Fabric Services enabled, contains an information disclosure vulnerability. A remote, unauthenticated attacker could potentially exploit this vulnerability by reverse engineering to retrieve sensitive information and access the REST API with admin privileges. Dell\u0027s smartfabric os10 There are vulnerabilities in inadequate protection of credentials.Information may be obtained. Dell SmartFabric OS10 is a Linux-based network switch operating system developed by Dell",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-29089"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018149"
},
{
"db": "VULHUB",
"id": "VHN-420623"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-29089",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018149",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2910",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-420623",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-420623"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018149"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2910"
},
{
"db": "NVD",
"id": "CVE-2022-29089"
}
]
},
"id": "VAR-202209-1935",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-420623"
}
],
"trust": 0.01
},
"last_update_date": "2024-08-14T15:11:15.385000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Dell SmartFabric OS10 Repair measures for information disclosure vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=209702"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2910"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-522",
"trust": 1.1
},
{
"problemtype": "Inadequate protection of credentials (CWE-522) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-420623"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018149"
},
{
"db": "NVD",
"id": "CVE-2022-29089"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://www.dell.com/support/kbdoc/en-us/000202971/dsa-2022-135-dell-emc-smartfabric-os10-security-update-for-multiple-security-vulnerabilities"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-29089"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-29089/"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-420623"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018149"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2910"
},
{
"db": "NVD",
"id": "CVE-2022-29089"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-420623"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018149"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2910"
},
{
"db": "NVD",
"id": "CVE-2022-29089"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-09-28T00:00:00",
"db": "VULHUB",
"id": "VHN-420623"
},
{
"date": "2023-10-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-018149"
},
{
"date": "2022-09-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2910"
},
{
"date": "2022-09-28T21:15:09.880000",
"db": "NVD",
"id": "CVE-2022-29089"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-09-30T00:00:00",
"db": "VULHUB",
"id": "VHN-420623"
},
{
"date": "2023-10-18T08:12:00",
"db": "JVNDB",
"id": "JVNDB-2022-018149"
},
{
"date": "2022-10-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2910"
},
{
"date": "2022-09-30T17:16:40.670000",
"db": "NVD",
"id": "CVE-2022-29089"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2910"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell\u0027s \u00a0smartfabric\u00a0os10\u00a0 Vulnerability regarding insufficient protection of authentication information in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018149"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2910"
}
],
"trust": 0.6
}
}
VAR-202209-2002
Vulnerability from variot - Updated: 2024-08-14 14:37Networking OS10, versions 10.5.1.x, 10.5.2.x, and 10.5.3.x contain a vulnerability that could allow an attacker to cause a system crash by running particular security scans. Dell's smartfabric os10 Exists in an out-of-bounds write vulnerability.Service operation interruption (DoS) It may be in a state. Dell SmartFabric OS10 is a Linux-based network switch operating system developed by Dell
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202209-2002",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "smartfabric os10",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.2.11"
},
{
"model": "smartfabric os10",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.3.5"
},
{
"model": "smartfabric os10",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.1.11"
},
{
"model": "smartfabric os10",
"scope": "gte",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.3.0"
},
{
"model": "smartfabric os10",
"scope": "gte",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.1.0"
},
{
"model": "smartfabric os10",
"scope": "gte",
"trust": 1.0,
"vendor": "dell",
"version": "10.5.2.0"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.3.0 that\u0027s all 10.5.3.5"
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.1.0 that\u0027s all 10.5.1.11"
},
{
"model": "smartfabric os10",
"scope": null,
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "smartfabric os10",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "10.5.2.0 that\u0027s all 10.5.2.11"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018118"
},
{
"db": "NVD",
"id": "CVE-2022-34424"
}
]
},
"cve": "CVE-2022-34424",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-34424",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-34424",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-34424",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "security_alert@emc.com",
"id": "CVE-2022-34424",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-34424",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-202209-2907",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018118"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2907"
},
{
"db": "NVD",
"id": "CVE-2022-34424"
},
{
"db": "NVD",
"id": "CVE-2022-34424"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Networking OS10, versions 10.5.1.x, 10.5.2.x, and 10.5.3.x contain a vulnerability that could allow an attacker to cause a system crash by running particular security scans. Dell\u0027s smartfabric os10 Exists in an out-of-bounds write vulnerability.Service operation interruption (DoS) It may be in a state. Dell SmartFabric OS10 is a Linux-based network switch operating system developed by Dell",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-34424"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018118"
},
{
"db": "VULHUB",
"id": "VHN-426740"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-34424",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018118",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2907",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-426740",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426740"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018118"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2907"
},
{
"db": "NVD",
"id": "CVE-2022-34424"
}
]
},
"id": "VAR-202209-2002",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-426740"
}
],
"trust": 0.01
},
"last_update_date": "2024-08-14T14:37:17.542000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Dell SmartFabric OS10 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=209700"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2907"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.1
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426740"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018118"
},
{
"db": "NVD",
"id": "CVE-2022-34424"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://www.dell.com/support/kbdoc/en-us/000202971/dsa-2022-135-dell-emc-smartfabric-os10-security-update-for-multiple-security-vulnerabilities"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-34424"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-34424/"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426740"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018118"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2907"
},
{
"db": "NVD",
"id": "CVE-2022-34424"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-426740"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018118"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2907"
},
{
"db": "NVD",
"id": "CVE-2022-34424"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-09-28T00:00:00",
"db": "VULHUB",
"id": "VHN-426740"
},
{
"date": "2023-10-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-018118"
},
{
"date": "2022-09-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2907"
},
{
"date": "2022-09-28T21:15:13.337000",
"db": "NVD",
"id": "CVE-2022-34424"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-09-30T00:00:00",
"db": "VULHUB",
"id": "VHN-426740"
},
{
"date": "2023-10-18T08:11:00",
"db": "JVNDB",
"id": "JVNDB-2022-018118"
},
{
"date": "2022-10-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2907"
},
{
"date": "2022-09-30T02:18:02.300000",
"db": "NVD",
"id": "CVE-2022-34424"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2907"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell\u0027s \u00a0smartfabric\u00a0os10\u00a0 Out-of-bounds write vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018118"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2907"
}
],
"trust": 0.6
}
}