Search criteria

4 vulnerabilities found for SmartCare by Huawei Technologies Co., Ltd.

CVE-2017-15313 (GCVE-0-2017-15313)

Vulnerability from nvd – Published: 2017-12-22 17:00 – Updated: 2024-09-16 18:24
VLAI?
Summary
Huawei SmartCare V200R003C10 has a CSV injection vulnerability. An remote authenticated attacker could inject malicious CSV expression to the affected device.
Severity ?
No CVSS data available.
CWE
  • CSV Injection
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:50:16.457Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.huawei.com/en/psirt/security-notices/huawei-sn-20171201-01-smartcare-en"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SmartCare",
          "vendor": "Huawei Technologies Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "V200R003C10"
            }
          ]
        }
      ],
      "datePublic": "2017-12-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Huawei SmartCare V200R003C10 has a CSV injection vulnerability. An remote authenticated attacker could inject malicious CSV expression to the affected device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CSV Injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-22T16:57:01",
        "orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
        "shortName": "huawei"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.huawei.com/en/psirt/security-notices/huawei-sn-20171201-01-smartcare-en"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@huawei.com",
          "DATE_PUBLIC": "2017-12-01T00:00:00",
          "ID": "CVE-2017-15313",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SmartCare",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V200R003C10"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Huawei Technologies Co., Ltd."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Huawei SmartCare V200R003C10 has a CSV injection vulnerability. An remote authenticated attacker could inject malicious CSV expression to the affected device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CSV Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.huawei.com/en/psirt/security-notices/huawei-sn-20171201-01-smartcare-en",
              "refsource": "CONFIRM",
              "url": "http://www.huawei.com/en/psirt/security-notices/huawei-sn-20171201-01-smartcare-en"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
    "assignerShortName": "huawei",
    "cveId": "CVE-2017-15313",
    "datePublished": "2017-12-22T17:00:00Z",
    "dateReserved": "2017-10-14T00:00:00",
    "dateUpdated": "2024-09-16T18:24:49.452Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-15312 (GCVE-0-2017-15312)

Vulnerability from nvd – Published: 2017-12-22 17:00 – Updated: 2024-09-17 03:03
VLAI?
Summary
Huawei SmartCare V200R003C10 has a stored XSS (cross-site scripting) vulnerability in the dashboard module. A remote authenticated attacker could exploit this vulnerability to inject malicious scripts in the affected device.
Severity ?
No CVSS data available.
CWE
  • XSS
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:50:16.675Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.huawei.com/en/psirt/security-notices/huawei-sn-20171201-01-smartcare-en"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SmartCare",
          "vendor": "Huawei Technologies Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "V200R003C10"
            }
          ]
        }
      ],
      "datePublic": "2017-12-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Huawei SmartCare V200R003C10 has a stored XSS (cross-site scripting) vulnerability in the dashboard module. A remote authenticated attacker could exploit this vulnerability to inject malicious scripts in the affected device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "XSS",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-22T16:57:01",
        "orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
        "shortName": "huawei"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.huawei.com/en/psirt/security-notices/huawei-sn-20171201-01-smartcare-en"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@huawei.com",
          "DATE_PUBLIC": "2017-12-01T00:00:00",
          "ID": "CVE-2017-15312",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SmartCare",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V200R003C10"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Huawei Technologies Co., Ltd."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Huawei SmartCare V200R003C10 has a stored XSS (cross-site scripting) vulnerability in the dashboard module. A remote authenticated attacker could exploit this vulnerability to inject malicious scripts in the affected device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "XSS"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.huawei.com/en/psirt/security-notices/huawei-sn-20171201-01-smartcare-en",
              "refsource": "CONFIRM",
              "url": "http://www.huawei.com/en/psirt/security-notices/huawei-sn-20171201-01-smartcare-en"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
    "assignerShortName": "huawei",
    "cveId": "CVE-2017-15312",
    "datePublished": "2017-12-22T17:00:00Z",
    "dateReserved": "2017-10-14T00:00:00",
    "dateUpdated": "2024-09-17T03:03:13.691Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-15313 (GCVE-0-2017-15313)

Vulnerability from cvelistv5 – Published: 2017-12-22 17:00 – Updated: 2024-09-16 18:24
VLAI?
Summary
Huawei SmartCare V200R003C10 has a CSV injection vulnerability. An remote authenticated attacker could inject malicious CSV expression to the affected device.
Severity ?
No CVSS data available.
CWE
  • CSV Injection
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:50:16.457Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.huawei.com/en/psirt/security-notices/huawei-sn-20171201-01-smartcare-en"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SmartCare",
          "vendor": "Huawei Technologies Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "V200R003C10"
            }
          ]
        }
      ],
      "datePublic": "2017-12-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Huawei SmartCare V200R003C10 has a CSV injection vulnerability. An remote authenticated attacker could inject malicious CSV expression to the affected device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CSV Injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-22T16:57:01",
        "orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
        "shortName": "huawei"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.huawei.com/en/psirt/security-notices/huawei-sn-20171201-01-smartcare-en"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@huawei.com",
          "DATE_PUBLIC": "2017-12-01T00:00:00",
          "ID": "CVE-2017-15313",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SmartCare",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V200R003C10"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Huawei Technologies Co., Ltd."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Huawei SmartCare V200R003C10 has a CSV injection vulnerability. An remote authenticated attacker could inject malicious CSV expression to the affected device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CSV Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.huawei.com/en/psirt/security-notices/huawei-sn-20171201-01-smartcare-en",
              "refsource": "CONFIRM",
              "url": "http://www.huawei.com/en/psirt/security-notices/huawei-sn-20171201-01-smartcare-en"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
    "assignerShortName": "huawei",
    "cveId": "CVE-2017-15313",
    "datePublished": "2017-12-22T17:00:00Z",
    "dateReserved": "2017-10-14T00:00:00",
    "dateUpdated": "2024-09-16T18:24:49.452Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-15312 (GCVE-0-2017-15312)

Vulnerability from cvelistv5 – Published: 2017-12-22 17:00 – Updated: 2024-09-17 03:03
VLAI?
Summary
Huawei SmartCare V200R003C10 has a stored XSS (cross-site scripting) vulnerability in the dashboard module. A remote authenticated attacker could exploit this vulnerability to inject malicious scripts in the affected device.
Severity ?
No CVSS data available.
CWE
  • XSS
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:50:16.675Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.huawei.com/en/psirt/security-notices/huawei-sn-20171201-01-smartcare-en"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SmartCare",
          "vendor": "Huawei Technologies Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "V200R003C10"
            }
          ]
        }
      ],
      "datePublic": "2017-12-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Huawei SmartCare V200R003C10 has a stored XSS (cross-site scripting) vulnerability in the dashboard module. A remote authenticated attacker could exploit this vulnerability to inject malicious scripts in the affected device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "XSS",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-22T16:57:01",
        "orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
        "shortName": "huawei"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.huawei.com/en/psirt/security-notices/huawei-sn-20171201-01-smartcare-en"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@huawei.com",
          "DATE_PUBLIC": "2017-12-01T00:00:00",
          "ID": "CVE-2017-15312",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SmartCare",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V200R003C10"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Huawei Technologies Co., Ltd."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Huawei SmartCare V200R003C10 has a stored XSS (cross-site scripting) vulnerability in the dashboard module. A remote authenticated attacker could exploit this vulnerability to inject malicious scripts in the affected device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "XSS"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.huawei.com/en/psirt/security-notices/huawei-sn-20171201-01-smartcare-en",
              "refsource": "CONFIRM",
              "url": "http://www.huawei.com/en/psirt/security-notices/huawei-sn-20171201-01-smartcare-en"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
    "assignerShortName": "huawei",
    "cveId": "CVE-2017-15312",
    "datePublished": "2017-12-22T17:00:00Z",
    "dateReserved": "2017-10-14T00:00:00",
    "dateUpdated": "2024-09-17T03:03:13.691Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}