Search

Find a vulnerability

Search criteria

    10 vulnerabilities found for Smart / Premium charging stations by Mennekes

    CVE-2025-22370 (GCVE-0-2025-22370)

    Vulnerability from nvd – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, SQL Injection in web configuration interface
    Summary
    Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    • OWASP-A03
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22370",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T15:03:05.010221Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T15:03:11.787Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-66",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-66 SQL Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "description": "OWASP-A03",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:46.281Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22370"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, SQL Injection in web configuration interface",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22370",
        "datePublished": "2025-03-11T13:40:22.946Z",
        "dateReserved": "2025-01-03T14:56:05.686Z",
        "dateUpdated": "2025-04-01T04:47:46.281Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22369 (GCVE-0-2025-22369)

    Vulnerability from nvd – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, Arbitrary file download using ReadFile endpoint
    Summary
    The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-552 - Files or Directories Accessible to External Parties
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22369",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T14:52:14.627801Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T14:52:22.813Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-597",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-597 Absolute Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-552",
                  "description": "CWE-552 Files or Directories Accessible to External Parties",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:47.988Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22369"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, Arbitrary file download using ReadFile endpoint",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22369",
        "datePublished": "2025-03-11T13:40:24.403Z",
        "dateReserved": "2025-01-03T14:56:05.686Z",
        "dateUpdated": "2025-04-01T04:47:47.988Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22368 (GCVE-0-2025-22368)

    Vulnerability from nvd – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, Command injection in sCU firmware update
    Summary
    The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    • CWE-250
    • OWASP-A03
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22368",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T15:03:42.139099Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T15:03:48.901Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-248",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-248 Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-250",
                  "description": "CWE-250",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "description": "OWASP-A03",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:45.140Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22368"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, Command injection in sCU firmware update",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22368",
        "datePublished": "2025-03-11T13:40:22.216Z",
        "dateReserved": "2025-01-03T14:56:05.686Z",
        "dateUpdated": "2025-04-01T04:47:45.140Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22367 (GCVE-0-2025-22367)

    Vulnerability from nvd – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, Command injection in time setting
    Summary
    The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    • CWE-250
    • OWASP-A03
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22367",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T19:23:05.314995Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T19:23:24.531Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-248",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-248 Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-250",
                  "description": "CWE-250",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "description": "OWASP-A03",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:44.127Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22367"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, Command injection in time setting",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22367",
        "datePublished": "2025-03-11T13:40:21.388Z",
        "dateReserved": "2025-01-03T14:56:05.686Z",
        "dateUpdated": "2025-04-01T04:47:44.127Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22366 (GCVE-0-2025-22366)

    Vulnerability from nvd – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, Command injection in firmware upgrade
    Summary
    The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    • CWE-250
    • OWASP-A03
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22366",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T14:53:28.425309Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T14:53:56.159Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-248",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-248 Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-250",
                  "description": "CWE-250",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "description": "OWASP-A03",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:47.110Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22366"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, Command injection in firmware upgrade",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22366",
        "datePublished": "2025-03-11T13:40:23.659Z",
        "dateReserved": "2025-01-03T14:56:05.685Z",
        "dateUpdated": "2025-04-01T04:47:47.110Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22369 (GCVE-0-2025-22369)

    Vulnerability from cvelistv5 – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, Arbitrary file download using ReadFile endpoint
    Summary
    The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-552 - Files or Directories Accessible to External Parties
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22369",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T14:52:14.627801Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T14:52:22.813Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-597",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-597 Absolute Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-552",
                  "description": "CWE-552 Files or Directories Accessible to External Parties",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:47.988Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22369"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, Arbitrary file download using ReadFile endpoint",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22369",
        "datePublished": "2025-03-11T13:40:24.403Z",
        "dateReserved": "2025-01-03T14:56:05.686Z",
        "dateUpdated": "2025-04-01T04:47:47.988Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22366 (GCVE-0-2025-22366)

    Vulnerability from cvelistv5 – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, Command injection in firmware upgrade
    Summary
    The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    • CWE-250
    • OWASP-A03
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22366",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T14:53:28.425309Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T14:53:56.159Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-248",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-248 Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-250",
                  "description": "CWE-250",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "description": "OWASP-A03",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:47.110Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22366"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, Command injection in firmware upgrade",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22366",
        "datePublished": "2025-03-11T13:40:23.659Z",
        "dateReserved": "2025-01-03T14:56:05.685Z",
        "dateUpdated": "2025-04-01T04:47:47.110Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22370 (GCVE-0-2025-22370)

    Vulnerability from cvelistv5 – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, SQL Injection in web configuration interface
    Summary
    Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    • OWASP-A03
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22370",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T15:03:05.010221Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T15:03:11.787Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-66",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-66 SQL Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "description": "OWASP-A03",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:46.281Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22370"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, SQL Injection in web configuration interface",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22370",
        "datePublished": "2025-03-11T13:40:22.946Z",
        "dateReserved": "2025-01-03T14:56:05.686Z",
        "dateUpdated": "2025-04-01T04:47:46.281Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22368 (GCVE-0-2025-22368)

    Vulnerability from cvelistv5 – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, Command injection in sCU firmware update
    Summary
    The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    • CWE-250
    • OWASP-A03
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22368",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T15:03:42.139099Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T15:03:48.901Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-248",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-248 Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-250",
                  "description": "CWE-250",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "description": "OWASP-A03",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:45.140Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22368"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, Command injection in sCU firmware update",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22368",
        "datePublished": "2025-03-11T13:40:22.216Z",
        "dateReserved": "2025-01-03T14:56:05.686Z",
        "dateUpdated": "2025-04-01T04:47:45.140Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22367 (GCVE-0-2025-22367)

    Vulnerability from cvelistv5 – Published: 2025-03-11 13:40 – Updated: 2025-04-01 04:47
    VLAI
    Title
    Mennekes smart/premium charges systems, Command injection in time setting
    Summary
    The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    • CWE-250
    • OWASP-A03
    Assigner
    References
    Impacted products
    Vendor Product Version
    Mennekes Smart / Premium charging stations Affected: * , < 2.15 (semver)
    Create a notification for this product.
    Date Public
    2025-03-10 14:00
    Credits
    Wilco van Beijnum Harm van den Brink(DIVD) Frank Breedijk (DIVD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22367",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T19:23:05.314995Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T19:23:24.531Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smart / Premium charging stations",
              "vendor": "Mennekes",
              "versions": [
                {
                  "lessThan": "2.15",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wilco van Beijnum"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Harm van den Brink(DIVD)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "Frank Breedijk (DIVD)"
            }
          ],
          "datePublic": "2025-03-10T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-248",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-248 Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/S:N/AU:Y",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-250",
                  "description": "CWE-250",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "description": "OWASP-A03",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-01T04:47:44.127Z",
            "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
            "shortName": "DIVD"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://csirt.divd.nl/CVE-2025-22367"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://csirt.divd.nl/DIVD-2025-00003"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Mennekes smart/premium charges systems, Command injection in time setting",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "assignerShortName": "DIVD",
        "cveId": "CVE-2025-22367",
        "datePublished": "2025-03-11T13:40:21.388Z",
        "dateReserved": "2025-01-03T14:56:05.686Z",
        "dateUpdated": "2025-04-01T04:47:44.127Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }