Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for SkyBridge MB-A100/MB-A110 by Seiko Solutions Inc.

    CVE-2026-50043 (GCVE-0-2026-50043)

    Vulnerability from nvd – Published: 2026-07-01 06:53 – Updated: 2026-07-01 12:24 Unsupported When Assigned
    VLAI
    Summary
    Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in SkyBridge MB-A100/MB-A110. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product with an administrative privilege.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper neutralization of special elements used in an OS command ('OS Command Injection')
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50043",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-01T12:24:19.749563Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-01T12:24:26.718Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A100/MB-A110",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027) issue exists in SkyBridge MB-A100/MB-A110. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product with an administrative privilege."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027)",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-01T06:53:32.950Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/94618/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN20721579/"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-50043",
        "datePublished": "2026-07-01T06:53:32.950Z",
        "dateReserved": "2026-06-08T06:52:54.348Z",
        "dateUpdated": "2026-07-01T12:24:26.718Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-32850 (GCVE-0-2024-32850)

    Vulnerability from nvd – Published: 2024-05-31 01:33 – Updated: 2024-08-02 02:20
    VLAI
    Summary
    Improper neutralization of special elements used in a command ('Command Injection') exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • Improper Neutralization of Special Elements used in a Command ('Command Injection')
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A100/MB-A110 Affected: firmware Ver. 4.2.2 and earlier
    Create a notification for this product.
    Seiko Solutions Inc. SkyBridge BASIC MB-A130 Affected: firmware Ver. 1.5.5 and earlier
    Create a notification for this product.
    seiko-sol skybridge_basic_mb-a130_firmware Affected: 0 , ≤ 1.5.5 (custom)
        cpe:2.3:o:seiko-sol:skybridge_basic_mb-a130_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    seiko-sol skybridge_mb-a110_firmware Affected: 0 , ≤ 4.2.2 (custom)
        cpe:2.3:o:seiko-sol:skybridge_mb-a110_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:seiko-sol:skybridge_basic_mb-a130_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "skybridge_basic_mb-a130_firmware",
                "vendor": "seiko-sol",
                "versions": [
                  {
                    "lessThanOrEqual": "1.5.5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:seiko-sol:skybridge_mb-a110_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "skybridge_mb-a110_firmware",
                "vendor": "seiko-sol",
                "versions": [
                  {
                    "lessThanOrEqual": "4.2.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-32850",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-31T16:32:25.573045Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-05T20:01:12.070Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:20:35.662Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/82992/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/vu/JVNVU94872523/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A100/MB-A110",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 4.2.2 and earlier"
                }
              ]
            },
            {
              "product": "SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 1.5.5 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper neutralization of special elements used in a command (\u0027Command Injection\u0027) exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-31T01:33:32.849Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/82992/"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94872523/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2024-32850",
        "datePublished": "2024-05-31T01:33:32.849Z",
        "dateReserved": "2024-04-19T05:24:47.944Z",
        "dateUpdated": "2024-08-02T02:20:35.662Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2026-50043 (GCVE-0-2026-50043)

    Vulnerability from cvelistv5 – Published: 2026-07-01 06:53 – Updated: 2026-07-01 12:24 Unsupported When Assigned
    VLAI
    Summary
    Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in SkyBridge MB-A100/MB-A110. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product with an administrative privilege.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper neutralization of special elements used in an OS command ('OS Command Injection')
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50043",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-01T12:24:19.749563Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-01T12:24:26.718Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A100/MB-A110",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027) issue exists in SkyBridge MB-A100/MB-A110. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product with an administrative privilege."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027)",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-01T06:53:32.950Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/94618/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN20721579/"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-50043",
        "datePublished": "2026-07-01T06:53:32.950Z",
        "dateReserved": "2026-06-08T06:52:54.348Z",
        "dateUpdated": "2026-07-01T12:24:26.718Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-32850 (GCVE-0-2024-32850)

    Vulnerability from cvelistv5 – Published: 2024-05-31 01:33 – Updated: 2024-08-02 02:20
    VLAI
    Summary
    Improper neutralization of special elements used in a command ('Command Injection') exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • Improper Neutralization of Special Elements used in a Command ('Command Injection')
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A100/MB-A110 Affected: firmware Ver. 4.2.2 and earlier
    Create a notification for this product.
    Seiko Solutions Inc. SkyBridge BASIC MB-A130 Affected: firmware Ver. 1.5.5 and earlier
    Create a notification for this product.
    seiko-sol skybridge_basic_mb-a130_firmware Affected: 0 , ≤ 1.5.5 (custom)
        cpe:2.3:o:seiko-sol:skybridge_basic_mb-a130_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    seiko-sol skybridge_mb-a110_firmware Affected: 0 , ≤ 4.2.2 (custom)
        cpe:2.3:o:seiko-sol:skybridge_mb-a110_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:seiko-sol:skybridge_basic_mb-a130_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "skybridge_basic_mb-a130_firmware",
                "vendor": "seiko-sol",
                "versions": [
                  {
                    "lessThanOrEqual": "1.5.5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:seiko-sol:skybridge_mb-a110_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "skybridge_mb-a110_firmware",
                "vendor": "seiko-sol",
                "versions": [
                  {
                    "lessThanOrEqual": "4.2.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-32850",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-31T16:32:25.573045Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-05T20:01:12.070Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:20:35.662Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/82992/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/vu/JVNVU94872523/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A100/MB-A110",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 4.2.2 and earlier"
                }
              ]
            },
            {
              "product": "SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 1.5.5 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper neutralization of special elements used in a command (\u0027Command Injection\u0027) exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-31T01:33:32.849Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/82992/"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94872523/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2024-32850",
        "datePublished": "2024-05-31T01:33:32.849Z",
        "dateReserved": "2024-04-19T05:24:47.944Z",
        "dateUpdated": "2024-08-02T02:20:35.662Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }