CVE-2026-50043 (GCVE-0-2026-50043)
Vulnerability from nvd – Published: 2026-07-01 06:53 – Updated: 2026-07-01 12:24 Unsupported When Assigned
VLAI
Summary
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in SkyBridge MB-A100/MB-A110. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product with an administrative privilege.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-78 - Improper neutralization of special elements used in an OS command ('OS Command Injection')
Assigner
References
2 references
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Seiko Solutions Inc. | SkyBridge MB-A100/MB-A110 |
Affected:
all versions
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50043",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-01T12:24:19.749563Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-01T12:24:26.718Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SkyBridge MB-A100/MB-A110",
"vendor": "Seiko Solutions Inc.",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027) issue exists in SkyBridge MB-A100/MB-A110. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product with an administrative privilege."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 8.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027)",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-01T06:53:32.950Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.seiko-sol.co.jp/archives/94618/"
},
{
"url": "https://jvn.jp/en/jp/JVN20721579/"
}
],
"tags": [
"unsupported-when-assigned"
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2026-50043",
"datePublished": "2026-07-01T06:53:32.950Z",
"dateReserved": "2026-06-08T06:52:54.348Z",
"dateUpdated": "2026-07-01T12:24:26.718Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-32850 (GCVE-0-2024-32850)
Vulnerability from nvd – Published: 2024-05-31 01:33 – Updated: 2024-08-02 02:20
VLAI
Summary
Improper neutralization of special elements used in a command ('Command Injection') exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- Improper Neutralization of Special Elements used in a Command ('Command Injection')
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
2 references
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Seiko Solutions Inc. | SkyBridge MB-A100/MB-A110 |
Affected:
firmware Ver. 4.2.2 and earlier
|
|
| Seiko Solutions Inc. | SkyBridge BASIC MB-A130 |
Affected:
firmware Ver. 1.5.5 and earlier
|
|
| seiko-sol | skybridge_basic_mb-a130_firmware |
Affected:
0 , ≤ 1.5.5
(custom)
cpe:2.3:o:seiko-sol:skybridge_basic_mb-a130_firmware:-:*:*:*:*:*:*:* |
|
| seiko-sol | skybridge_mb-a110_firmware |
Affected:
0 , ≤ 4.2.2
(custom)
cpe:2.3:o:seiko-sol:skybridge_mb-a110_firmware:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:seiko-sol:skybridge_basic_mb-a130_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "skybridge_basic_mb-a130_firmware",
"vendor": "seiko-sol",
"versions": [
{
"lessThanOrEqual": "1.5.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:seiko-sol:skybridge_mb-a110_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "skybridge_mb-a110_firmware",
"vendor": "seiko-sol",
"versions": [
{
"lessThanOrEqual": "4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-32850",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-31T16:32:25.573045Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-05T20:01:12.070Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:20:35.662Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.seiko-sol.co.jp/archives/82992/"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU94872523/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SkyBridge MB-A100/MB-A110",
"vendor": "Seiko Solutions Inc.",
"versions": [
{
"status": "affected",
"version": "firmware Ver. 4.2.2 and earlier"
}
]
},
{
"product": "SkyBridge BASIC MB-A130",
"vendor": "Seiko Solutions Inc.",
"versions": [
{
"status": "affected",
"version": "firmware Ver. 1.5.5 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper neutralization of special elements used in a command (\u0027Command Injection\u0027) exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-31T01:33:32.849Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.seiko-sol.co.jp/archives/82992/"
},
{
"url": "https://jvn.jp/en/vu/JVNVU94872523/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2024-32850",
"datePublished": "2024-05-31T01:33:32.849Z",
"dateReserved": "2024-04-19T05:24:47.944Z",
"dateUpdated": "2024-08-02T02:20:35.662Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2026-50043 (GCVE-0-2026-50043)
Vulnerability from cvelistv5 – Published: 2026-07-01 06:53 – Updated: 2026-07-01 12:24 Unsupported When Assigned
VLAI
Summary
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in SkyBridge MB-A100/MB-A110. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product with an administrative privilege.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-78 - Improper neutralization of special elements used in an OS command ('OS Command Injection')
Assigner
References
2 references
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Seiko Solutions Inc. | SkyBridge MB-A100/MB-A110 |
Affected:
all versions
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50043",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-01T12:24:19.749563Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-01T12:24:26.718Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SkyBridge MB-A100/MB-A110",
"vendor": "Seiko Solutions Inc.",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027) issue exists in SkyBridge MB-A100/MB-A110. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product with an administrative privilege."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 8.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027)",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-01T06:53:32.950Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.seiko-sol.co.jp/archives/94618/"
},
{
"url": "https://jvn.jp/en/jp/JVN20721579/"
}
],
"tags": [
"unsupported-when-assigned"
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2026-50043",
"datePublished": "2026-07-01T06:53:32.950Z",
"dateReserved": "2026-06-08T06:52:54.348Z",
"dateUpdated": "2026-07-01T12:24:26.718Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-32850 (GCVE-0-2024-32850)
Vulnerability from cvelistv5 – Published: 2024-05-31 01:33 – Updated: 2024-08-02 02:20
VLAI
Summary
Improper neutralization of special elements used in a command ('Command Injection') exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- Improper Neutralization of Special Elements used in a Command ('Command Injection')
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
2 references
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Seiko Solutions Inc. | SkyBridge MB-A100/MB-A110 |
Affected:
firmware Ver. 4.2.2 and earlier
|
|
| Seiko Solutions Inc. | SkyBridge BASIC MB-A130 |
Affected:
firmware Ver. 1.5.5 and earlier
|
|
| seiko-sol | skybridge_basic_mb-a130_firmware |
Affected:
0 , ≤ 1.5.5
(custom)
cpe:2.3:o:seiko-sol:skybridge_basic_mb-a130_firmware:-:*:*:*:*:*:*:* |
|
| seiko-sol | skybridge_mb-a110_firmware |
Affected:
0 , ≤ 4.2.2
(custom)
cpe:2.3:o:seiko-sol:skybridge_mb-a110_firmware:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:seiko-sol:skybridge_basic_mb-a130_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "skybridge_basic_mb-a130_firmware",
"vendor": "seiko-sol",
"versions": [
{
"lessThanOrEqual": "1.5.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:seiko-sol:skybridge_mb-a110_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "skybridge_mb-a110_firmware",
"vendor": "seiko-sol",
"versions": [
{
"lessThanOrEqual": "4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-32850",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-31T16:32:25.573045Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-05T20:01:12.070Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:20:35.662Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.seiko-sol.co.jp/archives/82992/"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU94872523/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SkyBridge MB-A100/MB-A110",
"vendor": "Seiko Solutions Inc.",
"versions": [
{
"status": "affected",
"version": "firmware Ver. 4.2.2 and earlier"
}
]
},
{
"product": "SkyBridge BASIC MB-A130",
"vendor": "Seiko Solutions Inc.",
"versions": [
{
"status": "affected",
"version": "firmware Ver. 1.5.5 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper neutralization of special elements used in a command (\u0027Command Injection\u0027) exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-31T01:33:32.849Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.seiko-sol.co.jp/archives/82992/"
},
{
"url": "https://jvn.jp/en/vu/JVNVU94872523/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2024-32850",
"datePublished": "2024-05-31T01:33:32.849Z",
"dateReserved": "2024-04-19T05:24:47.944Z",
"dateUpdated": "2024-08-02T02:20:35.662Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}