Search
Find a vulnerability
Search criteria
2 vulnerabilities found for SENTRON 3NA COM Fuse by Siemens
CVE-2024-7322 (GCVE-0-2024-7322)
Vulnerability from nvd – Published: 2025-01-15 07:59 – Updated: 2026-10-15 00:33
VLAI
EPSS
VEX
Title
Dos in ZigBee device due to unsolicited encrypted rejoin response
Summary
A ZigBee coordinator, router, or end device may change their node ID when an unsolicited encrypted rejoin response is received, this change in node ID causes Denial of Service (DoS). To recover from this DoS, the network must be re-established
Severity
5.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-15 14:46 UTC
CWE
- CWE-940 - Improper Verification of Source of a Communication Channel
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://community.silabs.com/068Vm00000I7ri2 | vendor-advisorypermissions-required |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| silabs.com | EmberZNet |
Affected:
0 , < 7.3.3
(semver)
Affected: 7.4.0 , < 7.4.4 (semver) |
|
| silabs.com | EmberZNet |
Affected:
0 , < 8.1.0
(semver)
|
|
| Siemens | SENTRON 3NA COM Fuse |
Affected:
0 , < V5.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7322",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-15T14:46:49.430161Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-15T14:46:57.645Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "SENTRON 3NA COM Fuse",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-15T00:33:46.461Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-099819.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"packageName": "GSDK",
"product": "EmberZNet",
"vendor": "silabs.com",
"versions": [
{
"lessThan": "7.3.3",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.4.4",
"status": "affected",
"version": "7.4.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"packageName": "SiSDK",
"product": "EmberZNet",
"vendor": "silabs.com",
"versions": [
{
"lessThan": "8.1.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A ZigBee coordinator, router, or end device may change their node ID when an unsolicited encrypted rejoin response is received, this change\u0026nbsp;in node ID causes Denial of Service (DoS). To recover from this DoS, the network must be re-established"
}
],
"value": "A ZigBee coordinator, router, or end device may change their node ID when an unsolicited encrypted rejoin response is received, this change\u00a0in node ID causes Denial of Service (DoS). To recover from this DoS, the network must be re-established"
}
],
"impacts": [
{
"capecId": "CAPEC-176",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-176 Configuration/Environment Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-940",
"description": "CWE-940 Improper Verification of Source of a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-20T15:10:01.669Z",
"orgId": "030b2754-1501-44a4-bef8-48be86a33bf4",
"shortName": "Silabs"
},
"references": [
{
"tags": [
"vendor-advisory",
"permissions-required"
],
"url": "https://community.silabs.com/068Vm00000I7ri2"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Dos in ZigBee device due to unsolicited encrypted rejoin response",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "030b2754-1501-44a4-bef8-48be86a33bf4",
"assignerShortName": "Silabs",
"cveId": "CVE-2024-7322",
"datePublished": "2025-01-15T07:59:55.430Z",
"dateReserved": "2024-07-31T09:01:54.841Z",
"dateUpdated": "2026-10-15T00:33:46.461Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-7322 (GCVE-0-2024-7322)
Vulnerability from cvelistv5 – Published: 2025-01-15 07:59 – Updated: 2026-10-15 00:33
VLAI
EPSS
VEX
Title
Dos in ZigBee device due to unsolicited encrypted rejoin response
Summary
A ZigBee coordinator, router, or end device may change their node ID when an unsolicited encrypted rejoin response is received, this change in node ID causes Denial of Service (DoS). To recover from this DoS, the network must be re-established
Severity
5.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-15 14:46 UTC
CWE
- CWE-940 - Improper Verification of Source of a Communication Channel
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://community.silabs.com/068Vm00000I7ri2 | vendor-advisorypermissions-required |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| silabs.com | EmberZNet |
Affected:
0 , < 7.3.3
(semver)
Affected: 7.4.0 , < 7.4.4 (semver) |
|
| silabs.com | EmberZNet |
Affected:
0 , < 8.1.0
(semver)
|
|
| Siemens | SENTRON 3NA COM Fuse |
Affected:
0 , < V5.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7322",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-15T14:46:49.430161Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-15T14:46:57.645Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "SENTRON 3NA COM Fuse",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-15T00:33:46.461Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-099819.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"packageName": "GSDK",
"product": "EmberZNet",
"vendor": "silabs.com",
"versions": [
{
"lessThan": "7.3.3",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.4.4",
"status": "affected",
"version": "7.4.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"packageName": "SiSDK",
"product": "EmberZNet",
"vendor": "silabs.com",
"versions": [
{
"lessThan": "8.1.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A ZigBee coordinator, router, or end device may change their node ID when an unsolicited encrypted rejoin response is received, this change\u0026nbsp;in node ID causes Denial of Service (DoS). To recover from this DoS, the network must be re-established"
}
],
"value": "A ZigBee coordinator, router, or end device may change their node ID when an unsolicited encrypted rejoin response is received, this change\u00a0in node ID causes Denial of Service (DoS). To recover from this DoS, the network must be re-established"
}
],
"impacts": [
{
"capecId": "CAPEC-176",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-176 Configuration/Environment Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-940",
"description": "CWE-940 Improper Verification of Source of a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-20T15:10:01.669Z",
"orgId": "030b2754-1501-44a4-bef8-48be86a33bf4",
"shortName": "Silabs"
},
"references": [
{
"tags": [
"vendor-advisory",
"permissions-required"
],
"url": "https://community.silabs.com/068Vm00000I7ri2"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Dos in ZigBee device due to unsolicited encrypted rejoin response",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "030b2754-1501-44a4-bef8-48be86a33bf4",
"assignerShortName": "Silabs",
"cveId": "CVE-2024-7322",
"datePublished": "2025-01-15T07:59:55.430Z",
"dateReserved": "2024-07-31T09:01:54.841Z",
"dateUpdated": "2026-10-15T00:33:46.461Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}