Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for SC9863A/T606/T612/T616/T750/T765/T760/T770/T820/S8000/T8300/T9300 by Unisoc (Shanghai) Technologies Co., Ltd.

    CVE-2025-31710 (GCVE-0-2025-31710)

    Vulnerability from nvd – Published: 2025-06-03 05:50 – Updated: 2025-06-03 15:19
    VLAI
    Summary
    In engineermode service, there is a possible command injection due to improper input validation. This could lead to local escalation of privilege with no additional execution privileges needed.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • cwe-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-31710",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-03T15:17:49.246871Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-77",
                    "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-03T15:19:39.406Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SC9863A/T606/T612/T616/T750/T765/T760/T770/T820/S8000/T8300/T9300",
              "vendor": "Unisoc (Shanghai) Technologies Co., Ltd.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Android13/Android14/Android15"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In engineermode service, there is a possible command injection due to improper input validation. This could lead to local escalation of privilege with no additional execution privileges needed."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "cwe-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-03T05:50:51.239Z",
            "orgId": "63f92e9c-2193-4c24-98a9-93640392c3d3",
            "shortName": "Unisoc"
          },
          "references": [
            {
              "url": "https://www.unisoc.com/en_us/secy/announcementDetail/1929773763314909186"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "63f92e9c-2193-4c24-98a9-93640392c3d3",
        "assignerShortName": "Unisoc",
        "cveId": "CVE-2025-31710",
        "datePublished": "2025-06-03T05:50:51.239Z",
        "dateReserved": "2025-04-01T08:28:54.048Z",
        "dateUpdated": "2025-06-03T15:19:39.406Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-31710 (GCVE-0-2025-31710)

    Vulnerability from cvelistv5 – Published: 2025-06-03 05:50 – Updated: 2025-06-03 15:19
    VLAI
    Summary
    In engineermode service, there is a possible command injection due to improper input validation. This could lead to local escalation of privilege with no additional execution privileges needed.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • cwe-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-31710",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-03T15:17:49.246871Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-77",
                    "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-03T15:19:39.406Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SC9863A/T606/T612/T616/T750/T765/T760/T770/T820/S8000/T8300/T9300",
              "vendor": "Unisoc (Shanghai) Technologies Co., Ltd.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Android13/Android14/Android15"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In engineermode service, there is a possible command injection due to improper input validation. This could lead to local escalation of privilege with no additional execution privileges needed."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "cwe-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-03T05:50:51.239Z",
            "orgId": "63f92e9c-2193-4c24-98a9-93640392c3d3",
            "shortName": "Unisoc"
          },
          "references": [
            {
              "url": "https://www.unisoc.com/en_us/secy/announcementDetail/1929773763314909186"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "63f92e9c-2193-4c24-98a9-93640392c3d3",
        "assignerShortName": "Unisoc",
        "cveId": "CVE-2025-31710",
        "datePublished": "2025-06-03T05:50:51.239Z",
        "dateReserved": "2025-04-01T08:28:54.048Z",
        "dateUpdated": "2025-06-03T15:19:39.406Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }