Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for RFID 181EIP by Siemens

    CVE-2018-4833 (GCVE-0-2018-4833)

    Vulnerability from nvd – Published: 2018-06-14 16:00 – Updated: 2024-08-05 05:18
    VLAI
    Summary
    A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.6), SCALANCE X-300 switch family (incl. SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X408 (All versions < V4.1.3), SCALANCE X414 (All versions), SIMATIC RF182C (All versions). Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client's DHCP request.
    Severity
    No CVSS data available.
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    References
    Date Public
    2018-06-12 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T05:18:26.432Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-181018.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "RFID 181EIP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "RUGGEDCOM Win",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "V4.4, V4.5, V5.0, and V5.1"
                }
              ]
            },
            {
              "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V5.2.3"
                }
              ]
            },
            {
              "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V5.4.1"
                }
              ]
            },
            {
              "product": "SCALANCE X-200RNA switch family",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.6"
                }
              ]
            },
            {
              "product": "SCALANCE X-300 switch family (incl. SIPLUS NET variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1.3"
                }
              ]
            },
            {
              "product": "SCALANCE X408",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1.3"
                }
              ]
            },
            {
              "product": "SCALANCE X414",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SIMATIC RF182C",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "datePublic": "2018-06-12T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.4.1), SCALANCE X-200RNA switch family (All versions \u003c V3.2.6), SCALANCE X-300 switch family (incl. SIPLUS NET variants) (All versions \u003c V4.1.3), SCALANCE X408 (All versions \u003c V4.1.3), SCALANCE X414 (All versions), SIMATIC RF182C (All versions). Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client\u0027s DHCP request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122: Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-14T21:05:17.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-181018.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2018-4833",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "RFID 181EIP",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "RUGGEDCOM Win",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "V4.4, V4.5, V5.0, and V5.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V5.2.3"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V5.4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE X-200RNA switch family",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V3.2.6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE X-300 switch family (incl. SIPLUS NET variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V4.1.3"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE X408",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V4.1.3"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE X414",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC RF182C",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.4.1), SCALANCE X-200RNA switch family (All versions \u003c V3.2.6), SCALANCE X-300 switch family (incl. SIPLUS NET variants) (All versions \u003c V4.1.3), SCALANCE X408 (All versions \u003c V4.1.3), SCALANCE X414 (All versions), SIMATIC RF182C (All versions). Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client\u0027s DHCP request."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-122: Heap-based Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-181018.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-181018.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2018-4833",
        "datePublished": "2018-06-14T16:00:00.000Z",
        "dateReserved": "2018-01-02T00:00:00.000Z",
        "dateUpdated": "2024-08-05T05:18:26.432Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-4833 (GCVE-0-2018-4833)

    Vulnerability from cvelistv5 – Published: 2018-06-14 16:00 – Updated: 2024-08-05 05:18
    VLAI
    Summary
    A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.6), SCALANCE X-300 switch family (incl. SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X408 (All versions < V4.1.3), SCALANCE X414 (All versions), SIMATIC RF182C (All versions). Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client's DHCP request.
    Severity
    No CVSS data available.
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    References
    Date Public
    2018-06-12 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T05:18:26.432Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-181018.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "RFID 181EIP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "RUGGEDCOM Win",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "V4.4, V4.5, V5.0, and V5.1"
                }
              ]
            },
            {
              "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V5.2.3"
                }
              ]
            },
            {
              "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V5.4.1"
                }
              ]
            },
            {
              "product": "SCALANCE X-200RNA switch family",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.6"
                }
              ]
            },
            {
              "product": "SCALANCE X-300 switch family (incl. SIPLUS NET variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1.3"
                }
              ]
            },
            {
              "product": "SCALANCE X408",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1.3"
                }
              ]
            },
            {
              "product": "SCALANCE X414",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SIMATIC RF182C",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "datePublic": "2018-06-12T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.4.1), SCALANCE X-200RNA switch family (All versions \u003c V3.2.6), SCALANCE X-300 switch family (incl. SIPLUS NET variants) (All versions \u003c V4.1.3), SCALANCE X408 (All versions \u003c V4.1.3), SCALANCE X414 (All versions), SIMATIC RF182C (All versions). Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client\u0027s DHCP request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122: Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-14T21:05:17.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-181018.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2018-4833",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "RFID 181EIP",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "RUGGEDCOM Win",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "V4.4, V4.5, V5.0, and V5.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V5.2.3"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V5.4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE X-200RNA switch family",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V3.2.6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE X-300 switch family (incl. SIPLUS NET variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V4.1.3"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE X408",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V4.1.3"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE X414",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC RF182C",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.4.1), SCALANCE X-200RNA switch family (All versions \u003c V3.2.6), SCALANCE X-300 switch family (incl. SIPLUS NET variants) (All versions \u003c V4.1.3), SCALANCE X408 (All versions \u003c V4.1.3), SCALANCE X414 (All versions), SIMATIC RF182C (All versions). Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client\u0027s DHCP request."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-122: Heap-based Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-181018.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-181018.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2018-4833",
        "datePublished": "2018-06-14T16:00:00.000Z",
        "dateReserved": "2018-01-02T00:00:00.000Z",
        "dateUpdated": "2024-08-05T05:18:26.432Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }