Search
Find a vulnerability
Search criteria
2 vulnerabilities found for RE210 AC750 by TP-Link Systems Inc.
CVE-2026-85384 (GCVE-0-2026-85384)
Vulnerability from nvd – Published: 2026-09-08 18:43 – Updated: 2026-09-10 03:57 Unsupported When Assigned
VLAI
EPSS
VEX
Title
Authenticated Stack-Based Buffer Overflow in RE210 AC750 Configuration Import
Summary
A stack-based buffer overflow vulnerability exists in the httpd component of RE210 AC750 due to improper bounds checking in the splitString function when processing an uploaded configuration file. An authenticated attacker on the local network can upload a crafted configuration file to trigger the overflow, leading to remote code execution.
Successful exploitation may allow unauthorized access to sensitive information, modification of device configuration and network behavior, or disruption of device availability.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-09 00:00 UTC
CWE
- CWE-121 - Stack-based buffer overflow
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | RE210 AC750 |
Affected:
0 , ≤ 3.14.2 Build 141218 Rel.36430n (EU)
(custom)
Affected: 0 , ≤ 3.14.2 Build 171205 Rel.71984n (US) (custom) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-85384",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-09T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T03:57:38.353Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"/usr/bin/httpd"
],
"product": "RE210 AC750",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThanOrEqual": "3.14.2 Build 141218 Rel.36430n (EU)",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThanOrEqual": "3.14.2 Build 171205 Rel.71984n (US)",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Michael Ace Bengil (Archan6el)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003c/div\u003e\u003cdiv\u003e\u003ci\u003e\u003c/i\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cspan\u003eA stack-based buffer overflow vulnerability exists in the httpd component of RE210 AC750 due to improper bounds checking in the \u003c/span\u003e\u003ccode\u003esplitString\u003c/code\u003e\u003cspan\u003e function when processing an uploaded configuration file. An authenticated attacker on the local network can upload a crafted configuration file to trigger the overflow, leading to remote code execution.\u003c/span\u003e\u003c/div\u003e\u003c/div\u003e\u003c/div\u003e\u003cdiv\u003e\u003cdiv\u003eSuccessful exploitation may allow unauthorized access to sensitive information, modification of device configuration and network behavior, or disruption of device availability.\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "A stack-based buffer overflow vulnerability exists in the httpd component of RE210 AC750 due to improper bounds checking in the splitString function when processing an uploaded configuration file. An authenticated attacker on the local network can upload a crafted configuration file to trigger the overflow, leading to remote code execution.\n\n\n\n\n\nSuccessful exploitation may allow unauthorized access to sensitive information, modification of device configuration and network behavior, or disruption of device availability."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based buffer overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T18:43:58.166Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"url": "https://www.tp-link.com/en/support/faq/3562/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"tags": [
"unsupported-when-assigned"
],
"title": "Authenticated Stack-Based Buffer Overflow in RE210 AC750 Configuration Import",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2026-85384",
"datePublished": "2026-09-08T18:43:58.166Z",
"dateReserved": "2026-09-03T18:02:10.505Z",
"dateUpdated": "2026-09-10T03:57:38.353Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-85384 (GCVE-0-2026-85384)
Vulnerability from cvelistv5 – Published: 2026-09-08 18:43 – Updated: 2026-09-10 03:57 Unsupported When Assigned
VLAI
EPSS
VEX
Title
Authenticated Stack-Based Buffer Overflow in RE210 AC750 Configuration Import
Summary
A stack-based buffer overflow vulnerability exists in the httpd component of RE210 AC750 due to improper bounds checking in the splitString function when processing an uploaded configuration file. An authenticated attacker on the local network can upload a crafted configuration file to trigger the overflow, leading to remote code execution.
Successful exploitation may allow unauthorized access to sensitive information, modification of device configuration and network behavior, or disruption of device availability.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-09 00:00 UTC
CWE
- CWE-121 - Stack-based buffer overflow
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | RE210 AC750 |
Affected:
0 , ≤ 3.14.2 Build 141218 Rel.36430n (EU)
(custom)
Affected: 0 , ≤ 3.14.2 Build 171205 Rel.71984n (US) (custom) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-85384",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-09T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T03:57:38.353Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"/usr/bin/httpd"
],
"product": "RE210 AC750",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThanOrEqual": "3.14.2 Build 141218 Rel.36430n (EU)",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThanOrEqual": "3.14.2 Build 171205 Rel.71984n (US)",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Michael Ace Bengil (Archan6el)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003c/div\u003e\u003cdiv\u003e\u003ci\u003e\u003c/i\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cspan\u003eA stack-based buffer overflow vulnerability exists in the httpd component of RE210 AC750 due to improper bounds checking in the \u003c/span\u003e\u003ccode\u003esplitString\u003c/code\u003e\u003cspan\u003e function when processing an uploaded configuration file. An authenticated attacker on the local network can upload a crafted configuration file to trigger the overflow, leading to remote code execution.\u003c/span\u003e\u003c/div\u003e\u003c/div\u003e\u003c/div\u003e\u003cdiv\u003e\u003cdiv\u003eSuccessful exploitation may allow unauthorized access to sensitive information, modification of device configuration and network behavior, or disruption of device availability.\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "A stack-based buffer overflow vulnerability exists in the httpd component of RE210 AC750 due to improper bounds checking in the splitString function when processing an uploaded configuration file. An authenticated attacker on the local network can upload a crafted configuration file to trigger the overflow, leading to remote code execution.\n\n\n\n\n\nSuccessful exploitation may allow unauthorized access to sensitive information, modification of device configuration and network behavior, or disruption of device availability."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based buffer overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T18:43:58.166Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"url": "https://www.tp-link.com/en/support/faq/3562/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"tags": [
"unsupported-when-assigned"
],
"title": "Authenticated Stack-Based Buffer Overflow in RE210 AC750 Configuration Import",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2026-85384",
"datePublished": "2026-09-08T18:43:58.166Z",
"dateReserved": "2026-09-03T18:02:10.505Z",
"dateUpdated": "2026-09-10T03:57:38.353Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}