Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for Pro-face Remote HMI by Schneider Electric

    CVE-2024-12399 (GCVE-0-2024-12399)

    Vulnerability from nvd – Published: 2025-01-17 09:37 – Updated: 2025-09-09 20:41
    VLAI
    Summary
    CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs man in the middle attack by intercepting the communication.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-924 - Improper Enforcement of Message Integrity During Transmission in a Communication Channel
    Assigner
    Impacted products
    Vendor Product Version
    Schneider Electric Pro-face GP-Pro EX Affected: all version , < v5.00.100 (version)
    Create a notification for this product.
    Schneider Electric Pro-face Remote HMI Affected: all versions , < v1.70.000 (version)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-12399",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-17T13:19:08.787250Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-12T16:55:25.689Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Pro-face GP-Pro EX",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "v5.00.100",
                  "status": "affected",
                  "version": "all version",
                  "versionType": "version"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Pro-face Remote HMI",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "v1.70.000",
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "version"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability\nexists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs\nman in the middle attack by intercepting the communication.\n\n\u003cbr\u003e"
                }
              ],
              "value": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability\nexists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs\nman in the middle attack by intercepting the communication."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-924",
                  "description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-09T20:41:23.793Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-02.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2024-12399",
        "datePublished": "2025-01-17T09:37:35.734Z",
        "dateReserved": "2024-12-10T09:21:04.278Z",
        "dateUpdated": "2025-09-09T20:41:23.793Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-12399 (GCVE-0-2024-12399)

    Vulnerability from cvelistv5 – Published: 2025-01-17 09:37 – Updated: 2025-09-09 20:41
    VLAI
    Summary
    CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs man in the middle attack by intercepting the communication.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-924 - Improper Enforcement of Message Integrity During Transmission in a Communication Channel
    Assigner
    Impacted products
    Vendor Product Version
    Schneider Electric Pro-face GP-Pro EX Affected: all version , < v5.00.100 (version)
    Create a notification for this product.
    Schneider Electric Pro-face Remote HMI Affected: all versions , < v1.70.000 (version)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-12399",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-17T13:19:08.787250Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-12T16:55:25.689Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Pro-face GP-Pro EX",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "v5.00.100",
                  "status": "affected",
                  "version": "all version",
                  "versionType": "version"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Pro-face Remote HMI",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "v1.70.000",
                  "status": "affected",
                  "version": "all versions",
                  "versionType": "version"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability\nexists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs\nman in the middle attack by intercepting the communication.\n\n\u003cbr\u003e"
                }
              ],
              "value": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability\nexists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs\nman in the middle attack by intercepting the communication."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-924",
                  "description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-09T20:41:23.793Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-02.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2024-12399",
        "datePublished": "2025-01-17T09:37:35.734Z",
        "dateReserved": "2024-12-10T09:21:04.278Z",
        "dateUpdated": "2025-09-09T20:41:23.793Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }