Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for PowerSYSTEM Center by SUBNET

    CVE-2024-28042 (GCVE-0-2024-28042)

    Vulnerability from nvd – Published: 2024-05-15 16:44 – Updated: 2024-08-02 00:48
    VLAI
    Title
    SUBNET PowerSYSTEM Center Reliance on Insufficiently Trustworthy Component
    Summary
    SUBNET Solutions Inc. has identified vulnerabilities in third-party components used in PowerSYSTEM Center.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    SUBNET PowerSYSTEM Center Affected: 0 , < 19 (custom)
    Create a notification for this product.
    subnet powersystem_center Affected: 0 , < 5.20.x.x (custom)
        cpe:2.3:a:subnet:powersystem_center:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    SUBNET Solutions reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:subnet:powersystem_center:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "powersystem_center",
                "vendor": "subnet",
                "versions": [
                  {
                    "lessThan": "5.20.x.x ",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-28042",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-16T18:29:11.493718Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T18:03:40.885Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T00:48:47.733Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerSYSTEM Center",
              "vendor": "SUBNET",
              "versions": [
                {
                  "lessThan": "19",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "SUBNET Solutions reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SUBNET Solutions Inc. has identified vulnerabilities in third-party components used in PowerSYSTEM Center."
                }
              ],
              "value": "SUBNET Solutions Inc. has identified vulnerabilities in third-party components used in PowerSYSTEM Center."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1357",
                  "description": "CWE-1357",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-28T16:28:31.073Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-02"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Subnet Solutions has fixed these issues by identifying and replacing out\n of date libraries used in previous versions of PowerSYSTEM Center. \nUsers are advised to update to version 5.20.x.x or newer. To obtain this\n software, contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://subnet.com/contact/\"\u003eSubnet Solution\u0027s Customer Service.\u003c/a\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Subnet Solutions has fixed these issues by identifying and replacing out\n of date libraries used in previous versions of PowerSYSTEM Center. \nUsers are advised to update to version 5.20.x.x or newer. To obtain this\n software, contact  Subnet Solution\u0027s Customer Service. https://subnet.com/contact/"
            }
          ],
          "source": {
            "advisory": "ICSA-24-135-02",
            "discovery": "INTERNAL"
          },
          "title": "SUBNET PowerSYSTEM Center Reliance on Insufficiently Trustworthy Component",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-28042",
        "datePublished": "2024-05-15T16:44:19.227Z",
        "dateReserved": "2024-04-12T20:44:48.685Z",
        "dateUpdated": "2024-08-02T00:48:47.733Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-28042 (GCVE-0-2024-28042)

    Vulnerability from cvelistv5 – Published: 2024-05-15 16:44 – Updated: 2024-08-02 00:48
    VLAI
    Title
    SUBNET PowerSYSTEM Center Reliance on Insufficiently Trustworthy Component
    Summary
    SUBNET Solutions Inc. has identified vulnerabilities in third-party components used in PowerSYSTEM Center.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    SUBNET PowerSYSTEM Center Affected: 0 , < 19 (custom)
    Create a notification for this product.
    subnet powersystem_center Affected: 0 , < 5.20.x.x (custom)
        cpe:2.3:a:subnet:powersystem_center:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    SUBNET Solutions reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:subnet:powersystem_center:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "powersystem_center",
                "vendor": "subnet",
                "versions": [
                  {
                    "lessThan": "5.20.x.x ",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-28042",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-16T18:29:11.493718Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T18:03:40.885Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T00:48:47.733Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerSYSTEM Center",
              "vendor": "SUBNET",
              "versions": [
                {
                  "lessThan": "19",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "SUBNET Solutions reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SUBNET Solutions Inc. has identified vulnerabilities in third-party components used in PowerSYSTEM Center."
                }
              ],
              "value": "SUBNET Solutions Inc. has identified vulnerabilities in third-party components used in PowerSYSTEM Center."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1357",
                  "description": "CWE-1357",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-28T16:28:31.073Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-02"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Subnet Solutions has fixed these issues by identifying and replacing out\n of date libraries used in previous versions of PowerSYSTEM Center. \nUsers are advised to update to version 5.20.x.x or newer. To obtain this\n software, contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://subnet.com/contact/\"\u003eSubnet Solution\u0027s Customer Service.\u003c/a\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Subnet Solutions has fixed these issues by identifying and replacing out\n of date libraries used in previous versions of PowerSYSTEM Center. \nUsers are advised to update to version 5.20.x.x or newer. To obtain this\n software, contact  Subnet Solution\u0027s Customer Service. https://subnet.com/contact/"
            }
          ],
          "source": {
            "advisory": "ICSA-24-135-02",
            "discovery": "INTERNAL"
          },
          "title": "SUBNET PowerSYSTEM Center Reliance on Insufficiently Trustworthy Component",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-28042",
        "datePublished": "2024-05-15T16:44:19.227Z",
        "dateReserved": "2024-04-12T20:44:48.685Z",
        "dateUpdated": "2024-08-02T00:48:47.733Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }