Search

Find a vulnerability

Search criteria

    6 vulnerabilities found for PowerProtect Cyber Recovery by Dell

    CVE-2025-26335 (GCVE-0-2025-26335)

    Vulnerability from nvd – Published: 2025-04-11 01:20 – Updated: 2025-04-11 16:02
    VLAI
    Summary
    Dell PowerProtect Cyber Recovery, versions prior to 19.18.0.2, contains an Insertion of Sensitive Information Into Sent Data vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Information exposure.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-201 - Insertion of Sensitive Information Into Sent Data
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Cyber Recovery Affected: N/A , < 19.18.0.2 (semver)
    Create a notification for this product.
    Date Public
    2025-04-09 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-26335",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-11T15:59:53.926509Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-11T16:02:52.857Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Cyber Recovery",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.18.0.2",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-04-09T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Cyber Recovery, versions prior to 19.18.0.2, contains an Insertion of Sensitive Information Into Sent Data vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Information exposure.\u003cbr\u003e"
                }
              ],
              "value": "Dell PowerProtect Cyber Recovery, versions prior to 19.18.0.2, contains an Insertion of Sensitive Information Into Sent Data vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Information exposure."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-201",
                  "description": "CWE-201: Insertion of Sensitive Information Into Sent Data",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-11T01:20:28.507Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000306005/dsa-2025-113-security-update-for-dell-powerprotect-cyber-recovery"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-26335",
        "datePublished": "2025-04-11T01:20:28.507Z",
        "dateReserved": "2025-02-07T06:04:04.738Z",
        "dateUpdated": "2025-04-11T16:02:52.857Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-32465 (GCVE-0-2023-32465)

    Vulnerability from nvd – Published: 2023-06-14 13:41 – Updated: 2024-12-30 15:41
    VLAI
    Summary
    Dell Power Protect Cyber Recovery, contains an Authentication Bypass vulnerability. An attacker could potentially exploit this vulnerability, leading to unauthorized admin access to the Cyber Recovery application. Exploitation may lead to complete system takeover by an attacker.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-644 - Improper Neutralization of HTTP Headers for Scripting Syntax
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Cyber Recovery Affected: 19.4 through 19.13.0.2
    Create a notification for this product.
    Date Public
    2023-06-14 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T15:18:37.695Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000214943/dsa-2023-201-security-update-for-dell-powerprotect-cyber-recovery"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-32465",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-30T15:41:08.289349Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-30T15:41:20.511Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Cyber Recovery",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "19.4 through 19.13.0.2"
                }
              ]
            }
          ],
          "datePublic": "2023-06-14T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell Power Protect Cyber Recovery, contains an Authentication Bypass vulnerability. An attacker could potentially exploit this vulnerability, leading to unauthorized admin access to the Cyber Recovery application. Exploitation may lead to complete system takeover by an attacker.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nDell Power Protect Cyber Recovery, contains an Authentication Bypass vulnerability. An attacker could potentially exploit this vulnerability, leading to unauthorized admin access to the Cyber Recovery application. Exploitation may lead to complete system takeover by an attacker.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-644",
                  "description": "CWE-644: Improper Neutralization of HTTP Headers for Scripting Syntax",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-06-14T13:41:10.622Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000214943/dsa-2023-201-security-update-for-dell-powerprotect-cyber-recovery"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-32465",
        "datePublished": "2023-06-14T13:41:10.622Z",
        "dateReserved": "2023-05-09T06:05:24.994Z",
        "dateUpdated": "2024-12-30T15:41:20.511Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-26335 (GCVE-0-2025-26335)

    Vulnerability from cvelistv5 – Published: 2025-04-11 01:20 – Updated: 2025-04-11 16:02
    VLAI
    Summary
    Dell PowerProtect Cyber Recovery, versions prior to 19.18.0.2, contains an Insertion of Sensitive Information Into Sent Data vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Information exposure.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-201 - Insertion of Sensitive Information Into Sent Data
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Cyber Recovery Affected: N/A , < 19.18.0.2 (semver)
    Create a notification for this product.
    Date Public
    2025-04-09 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-26335",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-11T15:59:53.926509Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-11T16:02:52.857Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Cyber Recovery",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.18.0.2",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-04-09T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Cyber Recovery, versions prior to 19.18.0.2, contains an Insertion of Sensitive Information Into Sent Data vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Information exposure.\u003cbr\u003e"
                }
              ],
              "value": "Dell PowerProtect Cyber Recovery, versions prior to 19.18.0.2, contains an Insertion of Sensitive Information Into Sent Data vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Information exposure."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-201",
                  "description": "CWE-201: Insertion of Sensitive Information Into Sent Data",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-11T01:20:28.507Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000306005/dsa-2025-113-security-update-for-dell-powerprotect-cyber-recovery"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-26335",
        "datePublished": "2025-04-11T01:20:28.507Z",
        "dateReserved": "2025-02-07T06:04:04.738Z",
        "dateUpdated": "2025-04-11T16:02:52.857Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-32465 (GCVE-0-2023-32465)

    Vulnerability from cvelistv5 – Published: 2023-06-14 13:41 – Updated: 2024-12-30 15:41
    VLAI
    Summary
    Dell Power Protect Cyber Recovery, contains an Authentication Bypass vulnerability. An attacker could potentially exploit this vulnerability, leading to unauthorized admin access to the Cyber Recovery application. Exploitation may lead to complete system takeover by an attacker.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-644 - Improper Neutralization of HTTP Headers for Scripting Syntax
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Cyber Recovery Affected: 19.4 through 19.13.0.2
    Create a notification for this product.
    Date Public
    2023-06-14 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T15:18:37.695Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000214943/dsa-2023-201-security-update-for-dell-powerprotect-cyber-recovery"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-32465",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-30T15:41:08.289349Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-30T15:41:20.511Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Cyber Recovery",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "19.4 through 19.13.0.2"
                }
              ]
            }
          ],
          "datePublic": "2023-06-14T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell Power Protect Cyber Recovery, contains an Authentication Bypass vulnerability. An attacker could potentially exploit this vulnerability, leading to unauthorized admin access to the Cyber Recovery application. Exploitation may lead to complete system takeover by an attacker.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nDell Power Protect Cyber Recovery, contains an Authentication Bypass vulnerability. An attacker could potentially exploit this vulnerability, leading to unauthorized admin access to the Cyber Recovery application. Exploitation may lead to complete system takeover by an attacker.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-644",
                  "description": "CWE-644: Improper Neutralization of HTTP Headers for Scripting Syntax",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-06-14T13:41:10.622Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000214943/dsa-2023-201-security-update-for-dell-powerprotect-cyber-recovery"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-32465",
        "datePublished": "2023-06-14T13:41:10.622Z",
        "dateReserved": "2023-05-09T06:05:24.994Z",
        "dateUpdated": "2024-12-30T15:41:20.511Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    VAR-202209-0060

    Vulnerability from variot - Updated: 2024-08-14 14:31

    Dell PowerProtect Cyber Recovery versions before 19.11.0.2 contain an authentication bypass vulnerability. A remote unauthenticated attacker may potentially access and interact with the docker registry API leading to an authentication bypass. The attacker may potentially alter the docker images leading to a loss of integrity and confidentiality

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202209-0060",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "powerprotect cyber recovery",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "dell",
            "version": "19.11.0.2"
          },
          {
            "model": "powerprotect cyber recovery",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          },
          {
            "model": "powerprotect cyber recovery",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          },
          {
            "model": "powerprotect cyber recovery",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "19.11.0.2"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-016140"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34372"
          }
        ]
      },
      "cve": "CVE-2022-34372",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-34372",
                "impactScore": 5.2,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "security_alert@emc.com",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-34372",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 9.1,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2022-34372",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-34372",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "security_alert@emc.com",
                "id": "CVE-2022-34372",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-34372",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202209-027",
                "trust": 0.6,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-016140"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-027"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34372"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34372"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Dell PowerProtect Cyber Recovery versions before 19.11.0.2 contain an authentication bypass vulnerability. A remote unauthenticated attacker may potentially access and interact with the docker registry API leading to an authentication bypass. The attacker may potentially alter the docker images leading to a loss of integrity and confidentiality",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-34372"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-016140"
          },
          {
            "db": "VULHUB",
            "id": "VHN-426688"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34372"
          }
        ],
        "trust": 1.8
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-34372",
            "trust": 3.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-016140",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-027",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-426688",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34372",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426688"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34372"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-016140"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-027"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34372"
          }
        ]
      },
      "id": "VAR-202209-0060",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426688"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2024-08-14T14:31:00.310000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Dell PowerProtect Cyber Recovery Remediation measures for authorization problem vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=206829"
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-027"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-287",
            "trust": 1.1
          },
          {
            "problemtype": "CWE-288",
            "trust": 1.0
          },
          {
            "problemtype": "Inappropriate authentication (CWE-287) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426688"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-016140"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34372"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.6,
            "url": "https://www.dell.com/support/kbdoc/en-us/000201970/dsa-2022-196-dell-emc-cyber-recovery-security-update-for-multiple-vulnerabilities"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-34372"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-34372/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426688"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34372"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-016140"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-027"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34372"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-426688"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34372"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-016140"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-027"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34372"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-09-01T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426688"
          },
          {
            "date": "2022-09-01T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-34372"
          },
          {
            "date": "2023-10-02T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-016140"
          },
          {
            "date": "2022-09-01T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202209-027"
          },
          {
            "date": "2022-09-01T19:15:12.357000",
            "db": "NVD",
            "id": "CVE-2022-34372"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-09-07T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426688"
          },
          {
            "date": "2022-09-01T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-34372"
          },
          {
            "date": "2023-10-02T08:10:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-016140"
          },
          {
            "date": "2022-09-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202209-027"
          },
          {
            "date": "2022-09-07T14:59:19.157000",
            "db": "NVD",
            "id": "CVE-2022-34372"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-027"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Dell\u0027s \u00a0powerprotect\u00a0cyber\u00a0recovery\u00a0 Authentication vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-016140"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "authorization issue",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202209-027"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202207-0231

    Vulnerability from variot - Updated: 2024-08-14 14:24

    Dell PowerProtect Cyber Recovery, versions prior to 19.11, contain a privilege escalation vulnerability on virtual appliance deployments. A lower-privileged authenticated user can chain docker commands to escalate privileges to root leading to complete system takeover. Dell EMC PowerProtect is an application software of Dell (Dell). Provides companies with the ability to protect, manage and recover their most critical application data. Attackers can use this vulnerability to obtain root privileges

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202207-0231",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "powerprotect cyber recovery",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "dell",
            "version": "19.11"
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-32481"
          }
        ]
      },
      "cve": "CVE-2022-32481",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-32481",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.1,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "VHN-424522",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:L/AC:L/AU:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2022-32481",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-32481",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "security_alert@emc.com",
                "id": "CVE-2022-32481",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202207-615",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-424522",
                "trust": 0.1,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2022-32481",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-424522"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-32481"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202207-615"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-32481"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-32481"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Dell PowerProtect Cyber Recovery, versions prior to 19.11, contain a privilege escalation vulnerability on virtual appliance deployments. A lower-privileged authenticated user can chain docker commands to escalate privileges to root leading to complete system takeover. Dell EMC PowerProtect is an application software of Dell (Dell). Provides companies with the ability to protect, manage and recover their most critical application data. Attackers can use this vulnerability to obtain root privileges",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-32481"
          },
          {
            "db": "VULHUB",
            "id": "VHN-424522"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-32481"
          }
        ],
        "trust": 1.08
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-32481",
            "trust": 1.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202207-615",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-424522",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-32481",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-424522"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-32481"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202207-615"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-32481"
          }
        ]
      },
      "id": "VAR-202207-0231",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-424522"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2024-08-14T14:24:41.094000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Dell EMC PowerProtect Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=200226"
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202207-615"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-269",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-424522"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-32481"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://support.emc.com/kb/000201213"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-32481/"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/269.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-424522"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-32481"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202207-615"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-32481"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-424522"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-32481"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202207-615"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-32481"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-07-07T00:00:00",
            "db": "VULHUB",
            "id": "VHN-424522"
          },
          {
            "date": "2022-07-07T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-32481"
          },
          {
            "date": "2022-07-07T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202207-615"
          },
          {
            "date": "2022-07-07T22:15:08.737000",
            "db": "NVD",
            "id": "CVE-2022-32481"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-07-15T00:00:00",
            "db": "VULHUB",
            "id": "VHN-424522"
          },
          {
            "date": "2022-07-15T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-32481"
          },
          {
            "date": "2022-07-18T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202207-615"
          },
          {
            "date": "2023-08-08T14:22:24.967000",
            "db": "NVD",
            "id": "CVE-2022-32481"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202207-615"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Dell EMC PowerProtect Security hole",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202207-615"
          }
        ],
        "trust": 0.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202207-615"
          }
        ],
        "trust": 0.6
      }
    }