Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for PcSuite by vivo

    CVE-2026-12058 (GCVE-0-2026-12058)

    Vulnerability from nvd – Published: 2026-06-12 08:02 – Updated: 2026-06-12 13:47
    VLAI
    Summary
    The connection confirmation pop-up of a specific feature in the PcSuite can be bypassed.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-807 - Reliance on untrusted inputs in a security decision
    Assigner
    Impacted products
    Vendor Product Version
    vivo PcSuite Affected: Versions below 6.2.0
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-12058",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-12T13:45:09.604595Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-12T13:47:01.315Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PcSuite",
              "vendor": "vivo",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions below 6.2.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The connection confirmation pop-up of a specific feature in the PcSuite can be bypassed."
                }
              ],
              "value": "The connection confirmation pop-up of a specific feature in the PcSuite can be bypassed."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-153",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-153 Input Data Manipulation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-807",
                  "description": "CWE-807 Reliance on untrusted inputs in a security decision",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-12T08:02:02.619Z",
            "orgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
            "shortName": "Vivo"
          },
          "references": [
            {
              "url": "https://www.vivo.com/en/support/security-advisory-detail?id=23"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
        "assignerShortName": "Vivo",
        "cveId": "CVE-2026-12058",
        "datePublished": "2026-06-12T08:02:02.619Z",
        "dateReserved": "2026-06-12T03:02:57.208Z",
        "dateUpdated": "2026-06-12T13:47:01.315Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11535 (GCVE-0-2026-11535)

    Vulnerability from nvd – Published: 2026-06-12 08:00 – Updated: 2026-06-12 13:52
    VLAI
    Summary
    An unauthorized access vulnerability exists in the PcSuite APP. The vulnerability can be exploited by attackers to Unauthorized access to the victim’s device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing authentication for critical function
    Assigner
    Impacted products
    Vendor Product Version
    vivo PcSuite Affected: Versions below 6.2.5
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11535",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-12T13:50:11.404961Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-12T13:52:08.489Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PcSuite",
              "vendor": "vivo",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions below 6.2.5"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthorized access vulnerability exists in the PcSuite APP. The vulnerability can be exploited by attackers to Unauthorized access to the victim\u2019s device."
                }
              ],
              "value": "An unauthorized access vulnerability exists in the PcSuite APP. The vulnerability can be exploited by attackers to Unauthorized access to the victim\u2019s device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-410",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-410 Information Elicitation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing authentication for critical function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-12T09:48:24.048Z",
            "orgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
            "shortName": "Vivo"
          },
          "references": [
            {
              "url": "https://www.vivo.com/en/support/security-advisory-detail?id=22"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
        "assignerShortName": "Vivo",
        "cveId": "CVE-2026-11535",
        "datePublished": "2026-06-12T08:00:50.162Z",
        "dateReserved": "2026-06-08T01:15:07.351Z",
        "dateUpdated": "2026-06-12T13:52:08.489Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-12058 (GCVE-0-2026-12058)

    Vulnerability from cvelistv5 – Published: 2026-06-12 08:02 – Updated: 2026-06-12 13:47
    VLAI
    Summary
    The connection confirmation pop-up of a specific feature in the PcSuite can be bypassed.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-807 - Reliance on untrusted inputs in a security decision
    Assigner
    Impacted products
    Vendor Product Version
    vivo PcSuite Affected: Versions below 6.2.0
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-12058",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-12T13:45:09.604595Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-12T13:47:01.315Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PcSuite",
              "vendor": "vivo",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions below 6.2.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The connection confirmation pop-up of a specific feature in the PcSuite can be bypassed."
                }
              ],
              "value": "The connection confirmation pop-up of a specific feature in the PcSuite can be bypassed."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-153",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-153 Input Data Manipulation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-807",
                  "description": "CWE-807 Reliance on untrusted inputs in a security decision",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-12T08:02:02.619Z",
            "orgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
            "shortName": "Vivo"
          },
          "references": [
            {
              "url": "https://www.vivo.com/en/support/security-advisory-detail?id=23"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
        "assignerShortName": "Vivo",
        "cveId": "CVE-2026-12058",
        "datePublished": "2026-06-12T08:02:02.619Z",
        "dateReserved": "2026-06-12T03:02:57.208Z",
        "dateUpdated": "2026-06-12T13:47:01.315Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11535 (GCVE-0-2026-11535)

    Vulnerability from cvelistv5 – Published: 2026-06-12 08:00 – Updated: 2026-06-12 13:52
    VLAI
    Summary
    An unauthorized access vulnerability exists in the PcSuite APP. The vulnerability can be exploited by attackers to Unauthorized access to the victim’s device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing authentication for critical function
    Assigner
    Impacted products
    Vendor Product Version
    vivo PcSuite Affected: Versions below 6.2.5
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11535",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-12T13:50:11.404961Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-12T13:52:08.489Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PcSuite",
              "vendor": "vivo",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions below 6.2.5"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthorized access vulnerability exists in the PcSuite APP. The vulnerability can be exploited by attackers to Unauthorized access to the victim\u2019s device."
                }
              ],
              "value": "An unauthorized access vulnerability exists in the PcSuite APP. The vulnerability can be exploited by attackers to Unauthorized access to the victim\u2019s device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-410",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-410 Information Elicitation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing authentication for critical function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-12T09:48:24.048Z",
            "orgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
            "shortName": "Vivo"
          },
          "references": [
            {
              "url": "https://www.vivo.com/en/support/security-advisory-detail?id=22"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
        "assignerShortName": "Vivo",
        "cveId": "CVE-2026-11535",
        "datePublished": "2026-06-12T08:00:50.162Z",
        "dateReserved": "2026-06-08T01:15:07.351Z",
        "dateUpdated": "2026-06-12T13:52:08.489Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }