Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for Pal Gate by Pal Electronics Systems

    CVE-2022-36782 (GCVE-0-2022-36782)

    Vulnerability from nvd – Published: 2022-09-13 14:58 – Updated: 2024-09-16 18:54
    VLAI
    Title
    Pal Electronics Systems - Pal Gate Authorization Errors
    Summary
    Pal Electronics Systems - Pal Gate Authorization Errors. The vulnerability is an authorization problem in PalGate device management android client app. Gates of bulidings and parking lots with a simple button in any smartphone. The API was found after a decompiling and static research using Jadx, and a dynamic analasys using Frida. The attacker can iterate over all the IOT devices to see every entry and exit, on every gate and device all over the world, he can also scrape the server and create a user's DB with full names and phone number of over 2.8 million users, and to see all of the users' movement in and out of gates, even in real time.
    CWE
    • Authorization Errors
    Assigner
    References
    Impacted products
    Vendor Product Version
    Pal Electronics Systems Pal Gate Affected: Update to the latest version , < unspecified (custom)
    Create a notification for this product.
    Date Public
    2022-09-11 00:00
    Credits
    Tal Saadi
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T10:14:28.471Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.gov.il/en/Departments/faq/cve_advisories"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Pal Gate",
              "vendor": "Pal Electronics Systems",
              "versions": [
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "Update to the latest version",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Tal Saadi"
            }
          ],
          "datePublic": "2022-09-11T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Pal Electronics Systems - Pal Gate Authorization Errors. The vulnerability is an authorization problem in PalGate device management android client app. Gates of bulidings and parking lots with a simple button in any smartphone. The API was found after a decompiling and static research using Jadx, and a dynamic analasys using Frida. The attacker can iterate over all the IOT devices to see every entry and exit, on every gate and device all over the world, he can also scrape the server and create a user\u0027s DB with full names and phone number of over 2.8 million users, and to see all of the users\u0027 movement in and out of gates, even in real time."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Authorization Errors",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-09-13T14:58:04.000Z",
            "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
            "shortName": "INCD"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.gov.il/en/Departments/faq/cve_advisories"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update to the latest version"
            }
          ],
          "source": {
            "defect": [
              "ILVN-2022-0053"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "Pal Electronics Systems - Pal Gate Authorization Errors",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cna@cyber.gov.il",
              "DATE_PUBLIC": "2022-09-11T05:45:00.000Z",
              "ID": "CVE-2022-36782",
              "STATE": "PUBLIC",
              "TITLE": "Pal Electronics Systems - Pal Gate Authorization Errors"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Pal Gate",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003e=",
                                "version_value": "Update to the latest version"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Pal Electronics Systems"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Tal Saadi"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Pal Electronics Systems - Pal Gate Authorization Errors. The vulnerability is an authorization problem in PalGate device management android client app. Gates of bulidings and parking lots with a simple button in any smartphone. The API was found after a decompiling and static research using Jadx, and a dynamic analasys using Frida. The attacker can iterate over all the IOT devices to see every entry and exit, on every gate and device all over the world, he can also scrape the server and create a user\u0027s DB with full names and phone number of over 2.8 million users, and to see all of the users\u0027 movement in and out of gates, even in real time."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Authorization Errors"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.gov.il/en/Departments/faq/cve_advisories",
                  "refsource": "MISC",
                  "url": "https://www.gov.il/en/Departments/faq/cve_advisories"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update to the latest version"
              }
            ],
            "source": {
              "defect": [
                "ILVN-2022-0053"
              ],
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "assignerShortName": "INCD",
        "cveId": "CVE-2022-36782",
        "datePublished": "2022-09-13T14:58:04.852Z",
        "dateReserved": "2022-07-26T00:00:00.000Z",
        "dateUpdated": "2024-09-16T18:54:37.400Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-36782 (GCVE-0-2022-36782)

    Vulnerability from cvelistv5 – Published: 2022-09-13 14:58 – Updated: 2024-09-16 18:54
    VLAI
    Title
    Pal Electronics Systems - Pal Gate Authorization Errors
    Summary
    Pal Electronics Systems - Pal Gate Authorization Errors. The vulnerability is an authorization problem in PalGate device management android client app. Gates of bulidings and parking lots with a simple button in any smartphone. The API was found after a decompiling and static research using Jadx, and a dynamic analasys using Frida. The attacker can iterate over all the IOT devices to see every entry and exit, on every gate and device all over the world, he can also scrape the server and create a user's DB with full names and phone number of over 2.8 million users, and to see all of the users' movement in and out of gates, even in real time.
    CWE
    • Authorization Errors
    Assigner
    References
    Impacted products
    Vendor Product Version
    Pal Electronics Systems Pal Gate Affected: Update to the latest version , < unspecified (custom)
    Create a notification for this product.
    Date Public
    2022-09-11 00:00
    Credits
    Tal Saadi
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T10:14:28.471Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.gov.il/en/Departments/faq/cve_advisories"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Pal Gate",
              "vendor": "Pal Electronics Systems",
              "versions": [
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "Update to the latest version",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Tal Saadi"
            }
          ],
          "datePublic": "2022-09-11T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Pal Electronics Systems - Pal Gate Authorization Errors. The vulnerability is an authorization problem in PalGate device management android client app. Gates of bulidings and parking lots with a simple button in any smartphone. The API was found after a decompiling and static research using Jadx, and a dynamic analasys using Frida. The attacker can iterate over all the IOT devices to see every entry and exit, on every gate and device all over the world, he can also scrape the server and create a user\u0027s DB with full names and phone number of over 2.8 million users, and to see all of the users\u0027 movement in and out of gates, even in real time."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Authorization Errors",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-09-13T14:58:04.000Z",
            "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
            "shortName": "INCD"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.gov.il/en/Departments/faq/cve_advisories"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update to the latest version"
            }
          ],
          "source": {
            "defect": [
              "ILVN-2022-0053"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "Pal Electronics Systems - Pal Gate Authorization Errors",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cna@cyber.gov.il",
              "DATE_PUBLIC": "2022-09-11T05:45:00.000Z",
              "ID": "CVE-2022-36782",
              "STATE": "PUBLIC",
              "TITLE": "Pal Electronics Systems - Pal Gate Authorization Errors"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Pal Gate",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003e=",
                                "version_value": "Update to the latest version"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Pal Electronics Systems"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Tal Saadi"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Pal Electronics Systems - Pal Gate Authorization Errors. The vulnerability is an authorization problem in PalGate device management android client app. Gates of bulidings and parking lots with a simple button in any smartphone. The API was found after a decompiling and static research using Jadx, and a dynamic analasys using Frida. The attacker can iterate over all the IOT devices to see every entry and exit, on every gate and device all over the world, he can also scrape the server and create a user\u0027s DB with full names and phone number of over 2.8 million users, and to see all of the users\u0027 movement in and out of gates, even in real time."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Authorization Errors"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.gov.il/en/Departments/faq/cve_advisories",
                  "refsource": "MISC",
                  "url": "https://www.gov.il/en/Departments/faq/cve_advisories"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update to the latest version"
              }
            ],
            "source": {
              "defect": [
                "ILVN-2022-0053"
              ],
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "assignerShortName": "INCD",
        "cveId": "CVE-2022-36782",
        "datePublished": "2022-09-13T14:58:04.852Z",
        "dateReserved": "2022-07-26T00:00:00.000Z",
        "dateUpdated": "2024-09-16T18:54:37.400Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }