Search
Find a vulnerability
Search criteria
4 vulnerabilities found for PT30X-NDI by PTZOptics
CVE-2024-8957 (GCVE-0-2024-8957)
Vulnerability from nvd – Published: 2024-09-17 20:08 – Updated: 2025-12-27 16:47 X_Known Exploited VulnerabilityTitle
PTZOptics NDI and SDI Cameras Command Injection via NTP Address Configuration
Summary
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.
Severity
7.2 (High)
SSVC
Exploitation: active
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://ptzoptics.com/firmware-changelog/ | vendor-advisory |
| https://vulncheck.com/advisories/ptzoptics-comman… | third-party-advisory |
| https://www.labs.greynoise.io/grimoire/2024-10-31… | exploittechnical-descriptionthird-party-advisory |
| https://www.greynoise.io/blog/greynoise-intellige… | |
| https://www.cisa.gov/known-exploited-vulnerabilit… | government-resource |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTZOptics | PT30X-SDI |
Affected:
0 , < 6.3.40
(semver)
|
|
| PTZOptics | PT30X-NDI |
Affected:
0 , < 6.3.40
(semver)
|
|
| ptzoptics | pt30x-sdi_firmware |
Affected:
0 , < 6.3.40
(semver)
cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:* |
|
| ptzoptics | pt30x-ndi_firmware |
Affected:
0 , < 6.3.40
(semver)
cpe:2.3:o:ptzoptics:pt30x-ndi_firmware:*:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "pt30x-sdi_firmware",
"vendor": "ptzoptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:ptzoptics:pt30x-ndi_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "pt30x-ndi_firmware",
"vendor": "ptzoptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8957",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-08T18:25:10.384044Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2024-11-04",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2024-8957"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T22:55:44.249Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit",
"technical-description",
"third-party-advisory"
],
"url": "https://www.labs.greynoise.io/grimoire/2024-10-31-sift-0-day-rce/"
},
{
"url": "https://www.greynoise.io/blog/greynoise-intelligence-discovers-zero-day-vulnerabilities-in-live-streaming-cameras-with-the-help-of-ai"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2024-8957"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-11-04T00:00:00.000Z",
"value": "CVE-2024-8957 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PT30X-SDI",
"vendor": "PTZOptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PT30X-NDI",
"vendor": "PTZOptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ptzoptics:pt30x-sdi:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.3.40",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ptzoptics:pt30x-ndi-xx-g2:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.3.40",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Konstantin Lazarev of GreyNoise"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.\u003cbr\u003e"
}
],
"value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-27T16:47:39.385Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://ptzoptics.com/firmware-changelog/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://vulncheck.com/advisories/ptzoptics-command-injection"
}
],
"source": {
"discovery": "UNKNOWN"
},
"tags": [
"x_known-exploited-vulnerability"
],
"title": "PTZOptics NDI and SDI Cameras Command Injection via NTP Address Configuration",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2024-8957",
"datePublished": "2024-09-17T20:08:25.588Z",
"dateReserved": "2024-09-17T19:08:48.129Z",
"dateUpdated": "2025-12-27T16:47:39.385Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-8956 (GCVE-0-2024-8956)
Vulnerability from nvd – Published: 2024-09-17 19:59 – Updated: 2025-11-22 12:09 X_Known Exploited VulnerabilityTitle
PTZOptics NDI and SDI Cameras /cgi-bin/param.cgi Insufficient Authentication
Summary
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.
Severity
9.1 (Critical)
SSVC
Exploitation: active
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://ptzoptics.com/firmware-changelog/ | vendor-advisory |
| https://vulncheck.com/advisories/ptzoptics-insuff… | third-party-advisory |
| https://www.labs.greynoise.io/grimoire/2024-10-31… | technical-descriptionthird-party-advisoryexploit |
| https://www.greynoise.io/blog/greynoise-intellige… | third-party-advisory |
| https://www.cisa.gov/known-exploited-vulnerabilit… | government-resource |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTZOptics | PT30X-SDI |
Affected:
0 , < 6.3.40
(semver)
|
|
| PTZOptics | PT30X-NDI |
Affected:
0 , < 6.3.40
(semver)
|
|
| ptzoptics | pt30x-sdi_firmware |
Affected:
0 , < 6.3.40
(custom)
cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:* |
|
| ptzoptics | pt30x-ndi-xx-g2_firmware |
Affected:
0 , < 6.3.40
(custom)
cpe:2.3:o:ptzoptics:pt30x-ndi-xx-g2_firmware:*:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "pt30x-sdi_firmware",
"vendor": "ptzoptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:ptzoptics:pt30x-ndi-xx-g2_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "pt30x-ndi-xx-g2_firmware",
"vendor": "ptzoptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8956",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-08T15:54:06.883084Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2024-11-04",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2024-8956"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T22:55:44.402Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"technical-description",
"third-party-advisory",
"exploit"
],
"url": "https://www.labs.greynoise.io/grimoire/2024-10-31-sift-0-day-rce/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.greynoise.io/blog/greynoise-intelligence-discovers-zero-day-vulnerabilities-in-live-streaming-cameras-with-the-help-of-ai"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2024-8956"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-11-04T00:00:00.000Z",
"value": "CVE-2024-8956 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PT30X-SDI",
"vendor": "PTZOptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PT30X-NDI",
"vendor": "PTZOptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ptzoptics:pt30x-sdi:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.3.40",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ptzoptics:pt30x-ndi-xx-g2:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.3.40",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Konstantin Lazarev of GreyNoise"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.\u003cbr\u003e"
}
],
"value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file."
}
],
"impacts": [
{
"capecId": "CAPEC-114",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-114 Authentication Abuse"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-22T12:09:58.681Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://ptzoptics.com/firmware-changelog/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://vulncheck.com/advisories/ptzoptics-insufficient-auth"
}
],
"source": {
"discovery": "UNKNOWN"
},
"tags": [
"x_known-exploited-vulnerability"
],
"title": "PTZOptics NDI and SDI Cameras /cgi-bin/param.cgi Insufficient Authentication",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2024-8956",
"datePublished": "2024-09-17T19:59:27.205Z",
"dateReserved": "2024-09-17T19:08:47.005Z",
"dateUpdated": "2025-11-22T12:09:58.681Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-8957 (GCVE-0-2024-8957)
Vulnerability from cvelistv5 – Published: 2024-09-17 20:08 – Updated: 2025-12-27 16:47 X_Known Exploited VulnerabilityTitle
PTZOptics NDI and SDI Cameras Command Injection via NTP Address Configuration
Summary
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.
Severity
7.2 (High)
SSVC
Exploitation: active
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://ptzoptics.com/firmware-changelog/ | vendor-advisory |
| https://vulncheck.com/advisories/ptzoptics-comman… | third-party-advisory |
| https://www.labs.greynoise.io/grimoire/2024-10-31… | exploittechnical-descriptionthird-party-advisory |
| https://www.greynoise.io/blog/greynoise-intellige… | |
| https://www.cisa.gov/known-exploited-vulnerabilit… | government-resource |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTZOptics | PT30X-SDI |
Affected:
0 , < 6.3.40
(semver)
|
|
| PTZOptics | PT30X-NDI |
Affected:
0 , < 6.3.40
(semver)
|
|
| ptzoptics | pt30x-sdi_firmware |
Affected:
0 , < 6.3.40
(semver)
cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:* |
|
| ptzoptics | pt30x-ndi_firmware |
Affected:
0 , < 6.3.40
(semver)
cpe:2.3:o:ptzoptics:pt30x-ndi_firmware:*:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "pt30x-sdi_firmware",
"vendor": "ptzoptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:ptzoptics:pt30x-ndi_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "pt30x-ndi_firmware",
"vendor": "ptzoptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8957",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-08T18:25:10.384044Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2024-11-04",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2024-8957"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T22:55:44.249Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit",
"technical-description",
"third-party-advisory"
],
"url": "https://www.labs.greynoise.io/grimoire/2024-10-31-sift-0-day-rce/"
},
{
"url": "https://www.greynoise.io/blog/greynoise-intelligence-discovers-zero-day-vulnerabilities-in-live-streaming-cameras-with-the-help-of-ai"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2024-8957"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-11-04T00:00:00.000Z",
"value": "CVE-2024-8957 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PT30X-SDI",
"vendor": "PTZOptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PT30X-NDI",
"vendor": "PTZOptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ptzoptics:pt30x-sdi:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.3.40",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ptzoptics:pt30x-ndi-xx-g2:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.3.40",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Konstantin Lazarev of GreyNoise"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.\u003cbr\u003e"
}
],
"value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-27T16:47:39.385Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://ptzoptics.com/firmware-changelog/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://vulncheck.com/advisories/ptzoptics-command-injection"
}
],
"source": {
"discovery": "UNKNOWN"
},
"tags": [
"x_known-exploited-vulnerability"
],
"title": "PTZOptics NDI and SDI Cameras Command Injection via NTP Address Configuration",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2024-8957",
"datePublished": "2024-09-17T20:08:25.588Z",
"dateReserved": "2024-09-17T19:08:48.129Z",
"dateUpdated": "2025-12-27T16:47:39.385Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-8956 (GCVE-0-2024-8956)
Vulnerability from cvelistv5 – Published: 2024-09-17 19:59 – Updated: 2025-11-22 12:09 X_Known Exploited VulnerabilityTitle
PTZOptics NDI and SDI Cameras /cgi-bin/param.cgi Insufficient Authentication
Summary
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.
Severity
9.1 (Critical)
SSVC
Exploitation: active
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://ptzoptics.com/firmware-changelog/ | vendor-advisory |
| https://vulncheck.com/advisories/ptzoptics-insuff… | third-party-advisory |
| https://www.labs.greynoise.io/grimoire/2024-10-31… | technical-descriptionthird-party-advisoryexploit |
| https://www.greynoise.io/blog/greynoise-intellige… | third-party-advisory |
| https://www.cisa.gov/known-exploited-vulnerabilit… | government-resource |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTZOptics | PT30X-SDI |
Affected:
0 , < 6.3.40
(semver)
|
|
| PTZOptics | PT30X-NDI |
Affected:
0 , < 6.3.40
(semver)
|
|
| ptzoptics | pt30x-sdi_firmware |
Affected:
0 , < 6.3.40
(custom)
cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:* |
|
| ptzoptics | pt30x-ndi-xx-g2_firmware |
Affected:
0 , < 6.3.40
(custom)
cpe:2.3:o:ptzoptics:pt30x-ndi-xx-g2_firmware:*:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "pt30x-sdi_firmware",
"vendor": "ptzoptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:ptzoptics:pt30x-ndi-xx-g2_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "pt30x-ndi-xx-g2_firmware",
"vendor": "ptzoptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8956",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-08T15:54:06.883084Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2024-11-04",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2024-8956"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T22:55:44.402Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"technical-description",
"third-party-advisory",
"exploit"
],
"url": "https://www.labs.greynoise.io/grimoire/2024-10-31-sift-0-day-rce/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.greynoise.io/blog/greynoise-intelligence-discovers-zero-day-vulnerabilities-in-live-streaming-cameras-with-the-help-of-ai"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2024-8956"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-11-04T00:00:00.000Z",
"value": "CVE-2024-8956 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PT30X-SDI",
"vendor": "PTZOptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PT30X-NDI",
"vendor": "PTZOptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ptzoptics:pt30x-sdi:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.3.40",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ptzoptics:pt30x-ndi-xx-g2:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.3.40",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Konstantin Lazarev of GreyNoise"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.\u003cbr\u003e"
}
],
"value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file."
}
],
"impacts": [
{
"capecId": "CAPEC-114",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-114 Authentication Abuse"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-22T12:09:58.681Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://ptzoptics.com/firmware-changelog/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://vulncheck.com/advisories/ptzoptics-insufficient-auth"
}
],
"source": {
"discovery": "UNKNOWN"
},
"tags": [
"x_known-exploited-vulnerability"
],
"title": "PTZOptics NDI and SDI Cameras /cgi-bin/param.cgi Insufficient Authentication",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2024-8956",
"datePublished": "2024-09-17T19:59:27.205Z",
"dateReserved": "2024-09-17T19:08:47.005Z",
"dateUpdated": "2025-11-22T12:09:58.681Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}