Search
Find a vulnerability
Search criteria
10 vulnerabilities found for PLANET IGS-5225-8P2T4S V2 by PLANET Technology Corp.
CVE-2026-81946 (GCVE-0-2026-81946)
Vulnerability from nvd – Published: 2026-09-18 15:19 – Updated: 2026-09-22 14:41
VLAI
EPSS
VEX
Title
PLANET IGS-5225-8P2T4S V1/V2 Weak Password Hashing via MD5 Algorithm
Summary
PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 use MD5-based password hashing, a cryptographic algorithm with known weaknesses. An attacker who obtains the device configuration file can recover the privileged-mode access password.
Severity
4.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-22 14:40 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.planet.com.tw/en/support/security-adv… | patchvendor-advisory |
| https://www.vulncheck.com/advisories/planet-igs-5… | third-party-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V1 |
Affected:
0 , < 1.2412b260707
(custom)
|
|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V2 |
Affected:
0 , < 2.2412b260519
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-81946",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T14:40:58.701750Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T14:41:11.110Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PLANET IGS-5225-8P2T4S V1",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "1.2412b260707",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "PLANET IGS-5225-8P2T4S V2",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "2.2412b260519",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Ivan Kurnakov, Vladimir Nazarov, Ilya Bubliy, Iliya Rogachev, Arseny Grigorev, Ivan Tarakanov, Aleksey Karimov (Positive Technologies)"
},
{
"lang": "en",
"type": "finder",
"value": "Maksim Gruzin"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 use MD5-based password hashing, a cryptographic algorithm with known weaknesses. An attacker who obtains the device configuration file can recover the privileged-mode access password."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-18T15:19:56.570Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Vendor Advisory",
"tags": [
"patch",
"vendor-advisory"
],
"url": "https://www.planet.com.tw/en/support/security-advisory/11"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/planet-igs-5225-8p2t4s-v1-v2-weak-password-hashing-via-md5-algorithm"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "PLANET IGS-5225-8P2T4S V1/V2 Weak Password Hashing via MD5 Algorithm",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-81946",
"datePublished": "2026-09-18T15:19:56.570Z",
"dateReserved": "2026-08-27T20:41:13.616Z",
"dateUpdated": "2026-09-22T14:41:11.110Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-81945 (GCVE-0-2026-81945)
Vulnerability from nvd – Published: 2026-09-18 15:19 – Updated: 2026-09-26 13:29
VLAI
EPSS
VEX
Title
PLANET IGS-5225-8P2T4S V1/V2 Admin Stack-Based Buffer Overflow via Web Server
Summary
PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 contain a stack-based buffer overflow in the web server. Insufficient bounds checking on data copied into a stack buffer allows a remote administrator to cause a denial of service or potentially execute arbitrary code on the underlying operating system.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-22 14:40 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.planet.com.tw/en/support/security-adv… | vendor-advisorypatch |
| https://www.vulncheck.com/advisories/planet-igs-5… | third-party-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V1 |
Affected:
0 , < 1.2412b260707
(custom)
|
|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V2 |
Affected:
0 , < 2.2412b260519
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-81945",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T14:40:06.596848Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T14:40:21.937Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PLANET IGS-5225-8P2T4S V1",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "1.2412b260707",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "PLANET IGS-5225-8P2T4S V2",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "2.2412b260519",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Ivan Kurnakov, Vladimir Nazarov, Ilya Bubliy, Iliya Rogachev, Arseny Grigorev, Ivan Tarakanov, Aleksey Karimov (Positive Technologies)"
},
{
"lang": "en",
"type": "finder",
"value": "Maksim Gruzin"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 contain a stack-based buffer overflow in the web server. Insufficient bounds checking on data copied into a stack buffer allows a remote administrator to cause a denial of service or potentially execute arbitrary code on the underlying operating system."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-26T13:29:55.247Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Vendor Advisory",
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.planet.com.tw/en/support/security-advisory/11"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/planet-igs-5225-8p2t4s-v1-v2-admin-stack-based-buffer-overflow-via-web-server"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "PLANET IGS-5225-8P2T4S V1/V2 Admin Stack-Based Buffer Overflow via Web Server",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-81945",
"datePublished": "2026-09-18T15:19:13.844Z",
"dateReserved": "2026-08-27T20:41:13.616Z",
"dateUpdated": "2026-09-26T13:29:55.247Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-81944 (GCVE-0-2026-81944)
Vulnerability from nvd – Published: 2026-09-18 15:18 – Updated: 2026-09-18 17:53
VLAI
EPSS
VEX
Title
PLANET IGS-5225-8P2T4S V1/V2 Stack-Based Buffer Overflow via Web Server
Summary
PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 contain a stack-based buffer overflow in the web server. Insufficient bounds checking on data copied into a stack buffer allows a remote authenticated attacker to cause a denial of service or potentially execute arbitrary code on the underlying operating system.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-18 17:53 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.planet.com.tw/en/support/security-adv… | vendor-advisorypatch |
| https://www.vulncheck.com/advisories/planet-igs-5… | third-party-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V1 |
Affected:
0 , < 1.2412b260707
(custom)
|
|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V2 |
Affected:
0 , < 2.2412b260519
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-81944",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-18T17:53:28.057338Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-18T17:53:38.527Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PLANET IGS-5225-8P2T4S V1",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "1.2412b260707",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "PLANET IGS-5225-8P2T4S V2",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "2.2412b260519",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Ivan Kurnakov, Vladimir Nazarov, Ilya Bubliy, Iliya Rogachev, Arseny Grigorev, Ivan Tarakanov, Aleksey Karimov (Positive Technologies)"
},
{
"lang": "en",
"type": "finder",
"value": "Maksim Gruzin"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 contain a stack-based buffer overflow in the web server. Insufficient bounds checking on data copied into a stack buffer allows a remote authenticated attacker to cause a denial of service or potentially execute arbitrary code on the underlying operating system."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-18T15:18:22.640Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Vendor Advisory",
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.planet.com.tw/en/support/security-advisory/11"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/planet-igs-5225-8p2t4s-v1-v2-stack-based-buffer-overflow-via-web-server"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "PLANET IGS-5225-8P2T4S V1/V2 Stack-Based Buffer Overflow via Web Server",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-81944",
"datePublished": "2026-09-18T15:18:22.640Z",
"dateReserved": "2026-08-27T20:41:13.615Z",
"dateUpdated": "2026-09-18T17:53:38.527Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-81943 (GCVE-0-2026-81943)
Vulnerability from nvd – Published: 2026-09-18 15:17 – Updated: 2026-09-18 15:41
VLAI
EPSS
VEX
Title
PLANET IGS-5225-8P2T4S V1/V2 Debug Mode RCE
Summary
PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 contain active debug functionality in the embedded software. An attacker with privileged access to the device can enable this debug mode to execute arbitrary code on the underlying operating system and gain root-level access.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-18 15:40 UTC
CWE
- CWE-489 - Active Debug Code
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.planet.com.tw/en/support/security-adv… | vendor-advisorypatch |
| https://www.vulncheck.com/advisories/planet-igs-5… | third-party-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V1 |
Affected:
0 , < 1.2412b260707
(custom)
|
|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V2 |
Affected:
0 , < 2.2412b260519
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-81943",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-18T15:40:36.637527Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-18T15:41:08.524Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PLANET IGS-5225-8P2T4S V1",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "1.2412b260707",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "PLANET IGS-5225-8P2T4S V2",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "2.2412b260519",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Ivan Kurnakov, Vladimir Nazarov, Ilya Bubliy, Iliya Rogachev, Arseny Grigorev, Ivan Tarakanov, Aleksey Karimov (Positive Technologies)"
},
{
"lang": "en",
"type": "finder",
"value": "Maksim Gruzin"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 contain active debug functionality in the embedded software. An attacker with privileged access to the device can enable this debug mode to execute arbitrary code on the underlying operating system and gain root-level access."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-489",
"description": "Active Debug Code",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-18T15:17:26.368Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Vendor Advisory",
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.planet.com.tw/en/support/security-advisory/11"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/planet-igs-5225-8p2t4s-v1-v2-debug-mode-rce"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "PLANET IGS-5225-8P2T4S V1/V2 Debug Mode RCE",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-81943",
"datePublished": "2026-09-18T15:17:26.368Z",
"dateReserved": "2026-08-27T20:41:13.615Z",
"dateUpdated": "2026-09-18T15:41:08.524Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-81942 (GCVE-0-2026-81942)
Vulnerability from nvd – Published: 2026-09-18 15:13 – Updated: 2026-09-21 20:50
VLAI
EPSS
VEX
Title
PLANET IGS-5225-8P2T4S V1/V2 OS Command Injection via Web Server
Summary
PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 contain an OS command injection vulnerability in the web server. User-supplied input is passed to system() without sufficient filtering, allowing a remote authenticated attacker to execute arbitrary commands on the underlying operating system and escalate privileges to root.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-21 16:42 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.planet.com.tw/en/support/security-adv… | vendor-advisorypatch |
| https://www.vulncheck.com/advisories/planet-igs-5… | third-party-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V1 |
Affected:
0 , < 1.2412b260707
(custom)
|
|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V2 |
Affected:
0 , < 2.2412b260519
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-81942",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-21T16:42:39.725533Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-21T20:50:57.257Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PLANET IGS-5225-8P2T4S V1",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "1.2412b260707",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "PLANET IGS-5225-8P2T4S V2",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "2.2412b260519",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Ivan Kurnakov, Vladimir Nazarov, Ilya Bubliy, Iliya Rogachev, Arseny Grigorev, Ivan Tarakanov, Aleksey Karimov (Positive Technologies)"
},
{
"lang": "en",
"type": "finder",
"value": "Maksim Gruzin"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 contain an OS command injection vulnerability in the web server. User-supplied input is passed to system() without sufficient filtering, allowing a remote authenticated attacker to execute arbitrary commands on the underlying operating system and escalate privileges to root."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-18T15:13:21.358Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Vendor Advisory",
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.planet.com.tw/en/support/security-advisory/11"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/planet-igs-5225-8p2t4s-v1-v2-os-command-injection-via-web-server"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "PLANET IGS-5225-8P2T4S V1/V2 OS Command Injection via Web Server",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-81942",
"datePublished": "2026-09-18T15:13:21.358Z",
"dateReserved": "2026-08-27T20:41:13.615Z",
"dateUpdated": "2026-09-21T20:50:57.257Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-81946 (GCVE-0-2026-81946)
Vulnerability from cvelistv5 – Published: 2026-09-18 15:19 – Updated: 2026-09-22 14:41
VLAI
EPSS
VEX
Title
PLANET IGS-5225-8P2T4S V1/V2 Weak Password Hashing via MD5 Algorithm
Summary
PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 use MD5-based password hashing, a cryptographic algorithm with known weaknesses. An attacker who obtains the device configuration file can recover the privileged-mode access password.
Severity
4.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-22 14:40 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.planet.com.tw/en/support/security-adv… | patchvendor-advisory |
| https://www.vulncheck.com/advisories/planet-igs-5… | third-party-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V1 |
Affected:
0 , < 1.2412b260707
(custom)
|
|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V2 |
Affected:
0 , < 2.2412b260519
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-81946",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T14:40:58.701750Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T14:41:11.110Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PLANET IGS-5225-8P2T4S V1",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "1.2412b260707",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "PLANET IGS-5225-8P2T4S V2",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "2.2412b260519",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Ivan Kurnakov, Vladimir Nazarov, Ilya Bubliy, Iliya Rogachev, Arseny Grigorev, Ivan Tarakanov, Aleksey Karimov (Positive Technologies)"
},
{
"lang": "en",
"type": "finder",
"value": "Maksim Gruzin"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 use MD5-based password hashing, a cryptographic algorithm with known weaknesses. An attacker who obtains the device configuration file can recover the privileged-mode access password."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-18T15:19:56.570Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Vendor Advisory",
"tags": [
"patch",
"vendor-advisory"
],
"url": "https://www.planet.com.tw/en/support/security-advisory/11"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/planet-igs-5225-8p2t4s-v1-v2-weak-password-hashing-via-md5-algorithm"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "PLANET IGS-5225-8P2T4S V1/V2 Weak Password Hashing via MD5 Algorithm",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-81946",
"datePublished": "2026-09-18T15:19:56.570Z",
"dateReserved": "2026-08-27T20:41:13.616Z",
"dateUpdated": "2026-09-22T14:41:11.110Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-81945 (GCVE-0-2026-81945)
Vulnerability from cvelistv5 – Published: 2026-09-18 15:19 – Updated: 2026-09-26 13:29
VLAI
EPSS
VEX
Title
PLANET IGS-5225-8P2T4S V1/V2 Admin Stack-Based Buffer Overflow via Web Server
Summary
PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 contain a stack-based buffer overflow in the web server. Insufficient bounds checking on data copied into a stack buffer allows a remote administrator to cause a denial of service or potentially execute arbitrary code on the underlying operating system.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-22 14:40 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.planet.com.tw/en/support/security-adv… | vendor-advisorypatch |
| https://www.vulncheck.com/advisories/planet-igs-5… | third-party-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V1 |
Affected:
0 , < 1.2412b260707
(custom)
|
|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V2 |
Affected:
0 , < 2.2412b260519
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-81945",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T14:40:06.596848Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T14:40:21.937Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PLANET IGS-5225-8P2T4S V1",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "1.2412b260707",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "PLANET IGS-5225-8P2T4S V2",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "2.2412b260519",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Ivan Kurnakov, Vladimir Nazarov, Ilya Bubliy, Iliya Rogachev, Arseny Grigorev, Ivan Tarakanov, Aleksey Karimov (Positive Technologies)"
},
{
"lang": "en",
"type": "finder",
"value": "Maksim Gruzin"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 contain a stack-based buffer overflow in the web server. Insufficient bounds checking on data copied into a stack buffer allows a remote administrator to cause a denial of service or potentially execute arbitrary code on the underlying operating system."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-26T13:29:55.247Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Vendor Advisory",
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.planet.com.tw/en/support/security-advisory/11"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/planet-igs-5225-8p2t4s-v1-v2-admin-stack-based-buffer-overflow-via-web-server"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "PLANET IGS-5225-8P2T4S V1/V2 Admin Stack-Based Buffer Overflow via Web Server",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-81945",
"datePublished": "2026-09-18T15:19:13.844Z",
"dateReserved": "2026-08-27T20:41:13.616Z",
"dateUpdated": "2026-09-26T13:29:55.247Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-81944 (GCVE-0-2026-81944)
Vulnerability from cvelistv5 – Published: 2026-09-18 15:18 – Updated: 2026-09-18 17:53
VLAI
EPSS
VEX
Title
PLANET IGS-5225-8P2T4S V1/V2 Stack-Based Buffer Overflow via Web Server
Summary
PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 contain a stack-based buffer overflow in the web server. Insufficient bounds checking on data copied into a stack buffer allows a remote authenticated attacker to cause a denial of service or potentially execute arbitrary code on the underlying operating system.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-18 17:53 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.planet.com.tw/en/support/security-adv… | vendor-advisorypatch |
| https://www.vulncheck.com/advisories/planet-igs-5… | third-party-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V1 |
Affected:
0 , < 1.2412b260707
(custom)
|
|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V2 |
Affected:
0 , < 2.2412b260519
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-81944",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-18T17:53:28.057338Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-18T17:53:38.527Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PLANET IGS-5225-8P2T4S V1",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "1.2412b260707",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "PLANET IGS-5225-8P2T4S V2",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "2.2412b260519",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Ivan Kurnakov, Vladimir Nazarov, Ilya Bubliy, Iliya Rogachev, Arseny Grigorev, Ivan Tarakanov, Aleksey Karimov (Positive Technologies)"
},
{
"lang": "en",
"type": "finder",
"value": "Maksim Gruzin"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 contain a stack-based buffer overflow in the web server. Insufficient bounds checking on data copied into a stack buffer allows a remote authenticated attacker to cause a denial of service or potentially execute arbitrary code on the underlying operating system."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-18T15:18:22.640Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Vendor Advisory",
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.planet.com.tw/en/support/security-advisory/11"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/planet-igs-5225-8p2t4s-v1-v2-stack-based-buffer-overflow-via-web-server"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "PLANET IGS-5225-8P2T4S V1/V2 Stack-Based Buffer Overflow via Web Server",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-81944",
"datePublished": "2026-09-18T15:18:22.640Z",
"dateReserved": "2026-08-27T20:41:13.615Z",
"dateUpdated": "2026-09-18T17:53:38.527Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-81943 (GCVE-0-2026-81943)
Vulnerability from cvelistv5 – Published: 2026-09-18 15:17 – Updated: 2026-09-18 15:41
VLAI
EPSS
VEX
Title
PLANET IGS-5225-8P2T4S V1/V2 Debug Mode RCE
Summary
PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 contain active debug functionality in the embedded software. An attacker with privileged access to the device can enable this debug mode to execute arbitrary code on the underlying operating system and gain root-level access.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-18 15:40 UTC
CWE
- CWE-489 - Active Debug Code
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.planet.com.tw/en/support/security-adv… | vendor-advisorypatch |
| https://www.vulncheck.com/advisories/planet-igs-5… | third-party-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V1 |
Affected:
0 , < 1.2412b260707
(custom)
|
|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V2 |
Affected:
0 , < 2.2412b260519
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-81943",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-18T15:40:36.637527Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-18T15:41:08.524Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PLANET IGS-5225-8P2T4S V1",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "1.2412b260707",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "PLANET IGS-5225-8P2T4S V2",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "2.2412b260519",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Ivan Kurnakov, Vladimir Nazarov, Ilya Bubliy, Iliya Rogachev, Arseny Grigorev, Ivan Tarakanov, Aleksey Karimov (Positive Technologies)"
},
{
"lang": "en",
"type": "finder",
"value": "Maksim Gruzin"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 contain active debug functionality in the embedded software. An attacker with privileged access to the device can enable this debug mode to execute arbitrary code on the underlying operating system and gain root-level access."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-489",
"description": "Active Debug Code",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-18T15:17:26.368Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Vendor Advisory",
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.planet.com.tw/en/support/security-advisory/11"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/planet-igs-5225-8p2t4s-v1-v2-debug-mode-rce"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "PLANET IGS-5225-8P2T4S V1/V2 Debug Mode RCE",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-81943",
"datePublished": "2026-09-18T15:17:26.368Z",
"dateReserved": "2026-08-27T20:41:13.615Z",
"dateUpdated": "2026-09-18T15:41:08.524Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-81942 (GCVE-0-2026-81942)
Vulnerability from cvelistv5 – Published: 2026-09-18 15:13 – Updated: 2026-09-21 20:50
VLAI
EPSS
VEX
Title
PLANET IGS-5225-8P2T4S V1/V2 OS Command Injection via Web Server
Summary
PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 contain an OS command injection vulnerability in the web server. User-supplied input is passed to system() without sufficient filtering, allowing a remote authenticated attacker to execute arbitrary commands on the underlying operating system and escalate privileges to root.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-21 16:42 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.planet.com.tw/en/support/security-adv… | vendor-advisorypatch |
| https://www.vulncheck.com/advisories/planet-igs-5… | third-party-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V1 |
Affected:
0 , < 1.2412b260707
(custom)
|
|
| PLANET Technology Corp. | PLANET IGS-5225-8P2T4S V2 |
Affected:
0 , < 2.2412b260519
(custom)
|
Date Public
2026-09-18 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-81942",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-21T16:42:39.725533Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-21T20:50:57.257Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PLANET IGS-5225-8P2T4S V1",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "1.2412b260707",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "PLANET IGS-5225-8P2T4S V2",
"vendor": "PLANET Technology Corp.",
"versions": [
{
"lessThan": "2.2412b260519",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Ivan Kurnakov, Vladimir Nazarov, Ilya Bubliy, Iliya Rogachev, Arseny Grigorev, Ivan Tarakanov, Aleksey Karimov (Positive Technologies)"
},
{
"lang": "en",
"type": "finder",
"value": "Maksim Gruzin"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "PLANET IGS-5225-8P2T4S industrial managed switch V1 and V2 firmware versions before 1.2412b260707 and 2.2412b260519 contain an OS command injection vulnerability in the web server. User-supplied input is passed to system() without sufficient filtering, allowing a remote authenticated attacker to execute arbitrary commands on the underlying operating system and escalate privileges to root."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-18T15:13:21.358Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Vendor Advisory",
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.planet.com.tw/en/support/security-advisory/11"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/planet-igs-5225-8p2t4s-v1-v2-os-command-injection-via-web-server"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "PLANET IGS-5225-8P2T4S V1/V2 OS Command Injection via Web Server",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-81942",
"datePublished": "2026-09-18T15:13:21.358Z",
"dateReserved": "2026-08-27T20:41:13.615Z",
"dateUpdated": "2026-09-21T20:50:57.257Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}