GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration
Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for OC400 v1 by TP-Link Systems Inc.

    CVE-2026-84941 (GCVE-0-2026-84941)

    Vulnerability from nvd – Published: 2026-09-10 23:35 – Updated: 2026-09-10 23:35
    VLAI
    Title
    Omada Controller XML External Entity (XXE) Injection in SAML IdP Metadata Parsing Leading to Arbitrary Local File Read
    Summary
    An information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information.
    CWE
    • CWE-611 - Improper restriction of XML external entity reference
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "Omada Software Controller (Windows)",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "6.2.14.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "Omada Software Controller (Linux)",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "6.2.14.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC2000 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.41.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC2000 v2",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "2.26.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC200 v3",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "3.3.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC220 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.6.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC220 v2",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "2.5.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC300 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.35.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC400 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.13.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "erikdejong"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "mattgsys"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "eslam moneer (tohtmosiii)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003eAn information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information.\u003c/div\u003e"
                }
              ],
              "value": "An information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-221",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-221 Data Serialization External Entities Blowup"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611 Improper restriction of XML external entity reference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-10T23:35:53.023Z",
            "orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
            "shortName": "TPLink"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://support.omadanetworks.com/en/download/software/omada-controller"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://support.omadanetworks.com/us/download/software/omada-controller"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://www.omadanetworks.com/en/support/download/"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://www.omadanetworks.com/us/support/download/"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://support.omadanetworks.com/en/document/133722/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Omada Controller XML External Entity (XXE) Injection in SAML IdP Metadata Parsing Leading to Arbitrary Local File Read",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
        "assignerShortName": "TPLink",
        "cveId": "CVE-2026-84941",
        "datePublished": "2026-09-10T23:35:53.023Z",
        "dateReserved": "2026-09-02T16:45:11.015Z",
        "dateUpdated": "2026-09-10T23:35:53.023Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-81531 (GCVE-0-2026-81531)

    Vulnerability from nvd – Published: 2026-09-08 16:53 – Updated: 2026-09-08 17:21
    VLAI
    Title
    Unauthenticated Account Information Disclosure in Multiple Omada Controllers
    Summary
    An information disclosure vulnerability has been identified in Omada Controller.  An API endpoint intended for Controller initialization remains accessible after completion and may disclose account-related information to unauthenticated remote users.  Successful exploitation may allow an attacker to remote query the affected endpoint that may facilitate user enumeration and subsequent attacks targeting administrative accounts.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-08 17:21 UTC
    CWE
    • CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
    Impacted products
    Vendor Product Version
    TP-Link System Inc. Omada Software Controller Affected: 0 , < 6.3.0.44 (custom)
    Create a notification for this product.
    TP-Link Systems Inc. OC200 V1 Affected: 0 , < (UN)_V1_1.42.10 Build 20260825 (custom)
    Create a notification for this product.
    TP Link Systems Inc. OC200 v2 Affected: 0 , < (UN)_V2_2.27.10 Build 20260825 (custom)
    Create a notification for this product.
    TP-Link Systems Inc OC200 v3 Affected: 0 , < (UN)_V3_3.4.10 Build 20260825 (custom)
    Create a notification for this product.
    TP-Link Systems Inc. OC220 v1 Affected: 0 , < (UN)_V1_1.7.10 Build 20260825 (custom)
    Create a notification for this product.
    TP-Link Systems Inc OC220 v2 Affected: 0 , < (UN)_V2_2.6.10 Build 20260825 (custom)
    Create a notification for this product.
    TP-Link Systems Inc. OC300 v1 Affected: 0 , < (UN)_V1_1.36.10 Build 20260825 (custom)
    Create a notification for this product.
    TP-Link Systems Inc. OC400 v1 Affected: 0 , < (UN)_V1_1.14.10 Build 20260825 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-81531",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-08T17:21:39.911958Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-08T17:21:54.913Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Omada Software Controller",
              "vendor": "TP-Link System Inc.",
              "versions": [
                {
                  "lessThan": "6.3.0.44",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "OC200 V1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "(UN)_V1_1.42.10 Build 20260825",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "OC200 v2",
              "vendor": "TP Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "(UN)_V2_2.27.10 Build 20260825",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "OC200 v3",
              "vendor": "TP-Link Systems Inc",
              "versions": [
                {
                  "lessThan": "(UN)_V3_3.4.10 Build 20260825",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "OC220 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "(UN)_V1_1.7.10 Build 20260825",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "OC220 v2",
              "vendor": "TP-Link Systems Inc",
              "versions": [
                {
                  "lessThan": "(UN)_V2_2.6.10 Build 20260825",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "OC300 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "(UN)_V1_1.36.10 Build 20260825",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "OC400 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "(UN)_V1_1.14.10 Build 20260825",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Joshua Chan, GitHub: https://github.com/popcorn94, Twitter: popc0rn94"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eAn information\ndisclosure vulnerability has been identified in Omada Controller.\u0026nbsp; An API endpoint intended for Controller initialization\nremains accessible after completion and may disclose account-related\ninformation to unauthenticated remote users.\u0026nbsp;\n\u003c/p\u003e\n\n\u003cp\u003eSuccessful\nexploitation may allow an attacker to remote query the affected endpoint that\nmay facilitate user enumeration and subsequent attacks targeting administrative\naccounts.\u003c/p\u003e"
                }
              ],
              "value": "An information\ndisclosure vulnerability has been identified in Omada Controller.\u00a0 An API endpoint intended for Controller initialization\nremains accessible after completion and may disclose account-related\ninformation to unauthenticated remote users.\u00a0\n\n\n\n\n\n\nSuccessful\nexploitation may allow an attacker to remote query the affected endpoint that\nmay facilitate user enumeration and subsequent attacks targeting administrative\naccounts."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-118",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-118 Collect \u0026 Analyze Information"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-08T16:53:18.786Z",
            "orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
            "shortName": "TPLink"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://support.omadanetworks.com/us/download/software/omada-controller/"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://support.omadanetworks.com/us/document/133567/"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://support.omadanetworks.com/en/download/software/omada-controller/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Unauthenticated Account Information Disclosure in Multiple Omada Controllers",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
        "assignerShortName": "TPLink",
        "cveId": "CVE-2026-81531",
        "datePublished": "2026-09-08T16:53:18.786Z",
        "dateReserved": "2026-08-26T22:31:50.287Z",
        "dateUpdated": "2026-09-08T17:21:54.913Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-84941 (GCVE-0-2026-84941)

    Vulnerability from cvelistv5 – Published: 2026-09-10 23:35 – Updated: 2026-09-10 23:35
    VLAI
    Title
    Omada Controller XML External Entity (XXE) Injection in SAML IdP Metadata Parsing Leading to Arbitrary Local File Read
    Summary
    An information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information.
    CWE
    • CWE-611 - Improper restriction of XML external entity reference
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "Omada Software Controller (Windows)",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "6.2.14.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "Omada Software Controller (Linux)",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "6.2.14.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC2000 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.41.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC2000 v2",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "2.26.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC200 v3",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "3.3.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC220 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.6.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC220 v2",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "2.5.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC300 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.35.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC400 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.13.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "erikdejong"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "mattgsys"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "eslam moneer (tohtmosiii)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003eAn information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information.\u003c/div\u003e"
                }
              ],
              "value": "An information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-221",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-221 Data Serialization External Entities Blowup"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611 Improper restriction of XML external entity reference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-10T23:35:53.023Z",
            "orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
            "shortName": "TPLink"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://support.omadanetworks.com/en/download/software/omada-controller"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://support.omadanetworks.com/us/download/software/omada-controller"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://www.omadanetworks.com/en/support/download/"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://www.omadanetworks.com/us/support/download/"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://support.omadanetworks.com/en/document/133722/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Omada Controller XML External Entity (XXE) Injection in SAML IdP Metadata Parsing Leading to Arbitrary Local File Read",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
        "assignerShortName": "TPLink",
        "cveId": "CVE-2026-84941",
        "datePublished": "2026-09-10T23:35:53.023Z",
        "dateReserved": "2026-09-02T16:45:11.015Z",
        "dateUpdated": "2026-09-10T23:35:53.023Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-81531 (GCVE-0-2026-81531)

    Vulnerability from cvelistv5 – Published: 2026-09-08 16:53 – Updated: 2026-09-08 17:21
    VLAI
    Title
    Unauthenticated Account Information Disclosure in Multiple Omada Controllers
    Summary
    An information disclosure vulnerability has been identified in Omada Controller.  An API endpoint intended for Controller initialization remains accessible after completion and may disclose account-related information to unauthenticated remote users.  Successful exploitation may allow an attacker to remote query the affected endpoint that may facilitate user enumeration and subsequent attacks targeting administrative accounts.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-08 17:21 UTC
    CWE
    • CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
    Impacted products
    Vendor Product Version
    TP-Link System Inc. Omada Software Controller Affected: 0 , < 6.3.0.44 (custom)
    Create a notification for this product.
    TP-Link Systems Inc. OC200 V1 Affected: 0 , < (UN)_V1_1.42.10 Build 20260825 (custom)
    Create a notification for this product.
    TP Link Systems Inc. OC200 v2 Affected: 0 , < (UN)_V2_2.27.10 Build 20260825 (custom)
    Create a notification for this product.
    TP-Link Systems Inc OC200 v3 Affected: 0 , < (UN)_V3_3.4.10 Build 20260825 (custom)
    Create a notification for this product.
    TP-Link Systems Inc. OC220 v1 Affected: 0 , < (UN)_V1_1.7.10 Build 20260825 (custom)
    Create a notification for this product.
    TP-Link Systems Inc OC220 v2 Affected: 0 , < (UN)_V2_2.6.10 Build 20260825 (custom)
    Create a notification for this product.
    TP-Link Systems Inc. OC300 v1 Affected: 0 , < (UN)_V1_1.36.10 Build 20260825 (custom)
    Create a notification for this product.
    TP-Link Systems Inc. OC400 v1 Affected: 0 , < (UN)_V1_1.14.10 Build 20260825 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-81531",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-08T17:21:39.911958Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-08T17:21:54.913Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Omada Software Controller",
              "vendor": "TP-Link System Inc.",
              "versions": [
                {
                  "lessThan": "6.3.0.44",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "OC200 V1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "(UN)_V1_1.42.10 Build 20260825",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "OC200 v2",
              "vendor": "TP Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "(UN)_V2_2.27.10 Build 20260825",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "OC200 v3",
              "vendor": "TP-Link Systems Inc",
              "versions": [
                {
                  "lessThan": "(UN)_V3_3.4.10 Build 20260825",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "OC220 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "(UN)_V1_1.7.10 Build 20260825",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "OC220 v2",
              "vendor": "TP-Link Systems Inc",
              "versions": [
                {
                  "lessThan": "(UN)_V2_2.6.10 Build 20260825",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "OC300 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "(UN)_V1_1.36.10 Build 20260825",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "OC400 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "(UN)_V1_1.14.10 Build 20260825",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Joshua Chan, GitHub: https://github.com/popcorn94, Twitter: popc0rn94"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eAn information\ndisclosure vulnerability has been identified in Omada Controller.\u0026nbsp; An API endpoint intended for Controller initialization\nremains accessible after completion and may disclose account-related\ninformation to unauthenticated remote users.\u0026nbsp;\n\u003c/p\u003e\n\n\u003cp\u003eSuccessful\nexploitation may allow an attacker to remote query the affected endpoint that\nmay facilitate user enumeration and subsequent attacks targeting administrative\naccounts.\u003c/p\u003e"
                }
              ],
              "value": "An information\ndisclosure vulnerability has been identified in Omada Controller.\u00a0 An API endpoint intended for Controller initialization\nremains accessible after completion and may disclose account-related\ninformation to unauthenticated remote users.\u00a0\n\n\n\n\n\n\nSuccessful\nexploitation may allow an attacker to remote query the affected endpoint that\nmay facilitate user enumeration and subsequent attacks targeting administrative\naccounts."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-118",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-118 Collect \u0026 Analyze Information"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-08T16:53:18.786Z",
            "orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
            "shortName": "TPLink"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://support.omadanetworks.com/us/download/software/omada-controller/"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://support.omadanetworks.com/us/document/133567/"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://support.omadanetworks.com/en/download/software/omada-controller/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Unauthenticated Account Information Disclosure in Multiple Omada Controllers",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
        "assignerShortName": "TPLink",
        "cveId": "CVE-2026-81531",
        "datePublished": "2026-09-08T16:53:18.786Z",
        "dateReserved": "2026-08-26T22:31:50.287Z",
        "dateUpdated": "2026-09-08T17:21:54.913Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }