GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration
Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for OC2000 v1 by TP-Link Systems Inc.

    CVE-2026-84941 (GCVE-0-2026-84941)

    Vulnerability from nvd – Published: 2026-09-10 23:35 – Updated: 2026-09-10 23:35
    VLAI
    Title
    Omada Controller XML External Entity (XXE) Injection in SAML IdP Metadata Parsing Leading to Arbitrary Local File Read
    Summary
    An information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information.
    CWE
    • CWE-611 - Improper restriction of XML external entity reference
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "Omada Software Controller (Windows)",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "6.2.14.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "Omada Software Controller (Linux)",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "6.2.14.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC2000 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.41.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC2000 v2",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "2.26.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC200 v3",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "3.3.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC220 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.6.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC220 v2",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "2.5.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC300 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.35.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC400 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.13.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "erikdejong"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "mattgsys"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "eslam moneer (tohtmosiii)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003eAn information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information.\u003c/div\u003e"
                }
              ],
              "value": "An information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-221",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-221 Data Serialization External Entities Blowup"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611 Improper restriction of XML external entity reference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-10T23:35:53.023Z",
            "orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
            "shortName": "TPLink"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://support.omadanetworks.com/en/download/software/omada-controller"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://support.omadanetworks.com/us/download/software/omada-controller"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://www.omadanetworks.com/en/support/download/"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://www.omadanetworks.com/us/support/download/"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://support.omadanetworks.com/en/document/133722/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Omada Controller XML External Entity (XXE) Injection in SAML IdP Metadata Parsing Leading to Arbitrary Local File Read",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
        "assignerShortName": "TPLink",
        "cveId": "CVE-2026-84941",
        "datePublished": "2026-09-10T23:35:53.023Z",
        "dateReserved": "2026-09-02T16:45:11.015Z",
        "dateUpdated": "2026-09-10T23:35:53.023Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-84941 (GCVE-0-2026-84941)

    Vulnerability from cvelistv5 – Published: 2026-09-10 23:35 – Updated: 2026-09-10 23:35
    VLAI
    Title
    Omada Controller XML External Entity (XXE) Injection in SAML IdP Metadata Parsing Leading to Arbitrary Local File Read
    Summary
    An information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information.
    CWE
    • CWE-611 - Improper restriction of XML external entity reference
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "Omada Software Controller (Windows)",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "6.2.14.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "Omada Software Controller (Linux)",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "6.2.14.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC2000 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.41.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC2000 v2",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "2.26.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC200 v3",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "3.3.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC220 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.6.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC220 v2",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "2.5.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC300 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.35.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC400 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.13.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "erikdejong"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "mattgsys"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "eslam moneer (tohtmosiii)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003eAn information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information.\u003c/div\u003e"
                }
              ],
              "value": "An information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-221",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-221 Data Serialization External Entities Blowup"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611 Improper restriction of XML external entity reference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-10T23:35:53.023Z",
            "orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
            "shortName": "TPLink"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://support.omadanetworks.com/en/download/software/omada-controller"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://support.omadanetworks.com/us/download/software/omada-controller"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://www.omadanetworks.com/en/support/download/"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://www.omadanetworks.com/us/support/download/"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://support.omadanetworks.com/en/document/133722/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Omada Controller XML External Entity (XXE) Injection in SAML IdP Metadata Parsing Leading to Arbitrary Local File Read",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
        "assignerShortName": "TPLink",
        "cveId": "CVE-2026-84941",
        "datePublished": "2026-09-10T23:35:53.023Z",
        "dateReserved": "2026-09-02T16:45:11.015Z",
        "dateUpdated": "2026-09-10T23:35:53.023Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }