Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for Nova 430H eNodeB (model pBS3101SH) by Baicells

    CVE-2026-96274 (GCVE-0-2026-96274)

    Vulnerability from nvd – Published: 2026-09-29 19:29 – Updated: 2026-09-29 21:01
    VLAI
    Title
    Uncaught exception in Baicells Nova 430H
    Summary
    In Baicells Nova 430H, an unauthenticated device within radio range can send a malformed uplink message during connection setup that contains an invalid NAS payload. Because the eNodeB does not properly validate this payload, it forwards the message to the core network, which can trigger a shutdown of the signaling association for the cell. This results in a temporary service disruption until the eNodeB and core network re-establish connectivity.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-29 20:57 UTC
    CWE
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Baicells Nova 430H eNodeB (model pBS3101SH) Affected: 0 , ≤ BaiBLQ_3.0.12 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-96274",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-29T20:57:13.860311Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-29T21:01:58.604Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Nova 430H eNodeB  (model pBS3101SH)",
              "vendor": "Baicells",
              "versions": [
                {
                  "lessThanOrEqual": "BaiBLQ_3.0.12",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Qiqing Huang reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "In Baicells Nova 430H, an unauthenticated device within radio range can send a malformed uplink message during connection setup that contains an invalid NAS payload. Because the eNodeB does not properly validate this payload, it forwards the message to the core network, which can trigger a shutdown of the signaling association for the cell. This results in a temporary service disruption until the eNodeB and core network re-establish connectivity.\u0026nbsp;\u003cbr\u003e"
                }
              ],
              "value": "In Baicells Nova 430H, an unauthenticated device within radio range can send a malformed uplink message during connection setup that contains an invalid NAS payload. Because the eNodeB does not properly validate this payload, it forwards the message to the core network, which can trigger a shutdown of the signaling association for the cell. This results in a temporary service disruption until the eNodeB and core network re-establish connectivity."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-248",
                  "description": "CWE-248 Uncaught exception",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-29T19:29:13.172Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Uncaught exception in Baicells Nova 430H",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-96274",
        "datePublished": "2026-09-29T19:29:13.172Z",
        "dateReserved": "2026-09-22T20:38:24.656Z",
        "dateUpdated": "2026-09-29T21:01:58.604Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-96274 (GCVE-0-2026-96274)

    Vulnerability from cvelistv5 – Published: 2026-09-29 19:29 – Updated: 2026-09-29 21:01
    VLAI
    Title
    Uncaught exception in Baicells Nova 430H
    Summary
    In Baicells Nova 430H, an unauthenticated device within radio range can send a malformed uplink message during connection setup that contains an invalid NAS payload. Because the eNodeB does not properly validate this payload, it forwards the message to the core network, which can trigger a shutdown of the signaling association for the cell. This results in a temporary service disruption until the eNodeB and core network re-establish connectivity.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-29 20:57 UTC
    CWE
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Baicells Nova 430H eNodeB (model pBS3101SH) Affected: 0 , ≤ BaiBLQ_3.0.12 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-96274",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-29T20:57:13.860311Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-29T21:01:58.604Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Nova 430H eNodeB  (model pBS3101SH)",
              "vendor": "Baicells",
              "versions": [
                {
                  "lessThanOrEqual": "BaiBLQ_3.0.12",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Qiqing Huang reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "In Baicells Nova 430H, an unauthenticated device within radio range can send a malformed uplink message during connection setup that contains an invalid NAS payload. Because the eNodeB does not properly validate this payload, it forwards the message to the core network, which can trigger a shutdown of the signaling association for the cell. This results in a temporary service disruption until the eNodeB and core network re-establish connectivity.\u0026nbsp;\u003cbr\u003e"
                }
              ],
              "value": "In Baicells Nova 430H, an unauthenticated device within radio range can send a malformed uplink message during connection setup that contains an invalid NAS payload. Because the eNodeB does not properly validate this payload, it forwards the message to the core network, which can trigger a shutdown of the signaling association for the cell. This results in a temporary service disruption until the eNodeB and core network re-establish connectivity."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-248",
                  "description": "CWE-248 Uncaught exception",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-29T19:29:13.172Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-04"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Uncaught exception in Baicells Nova 430H",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-96274",
        "datePublished": "2026-09-29T19:29:13.172Z",
        "dateReserved": "2026-09-22T20:38:24.656Z",
        "dateUpdated": "2026-09-29T21:01:58.604Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }